One solution, many application Integrated Electronic Solution PowerSupply Flex.

Slides:



Advertisements
Similar presentations
Magnetek Material Handling AC Controls
Advertisements

~ Mini Programmable DC Power Supply ~. mPP Series :
Control Circuit Protection Supplementary Protectors vs
Variable Frequency Drives Bypass Options
CB Series: Smart Battery Charger
Technology The All In One range “dc UPS Power Supply” is based on two strategic know-how elements Switching technology Adel system has a 20 year experience.
Delta Confidential Apr GAIA-series 5-11KVA Introduction.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
LP33 Series UPS kVA 400Vac/CE
1 Presentation Protect ph ~ / 3 ph ~ transformerless 3 ph ~ / 1 ph ~ 3 ph ~ / 3 ph ~ PROTECT PROTECT PROTECT PROTECT
Elec467 Power Machines & Transformers
Circuit Protection  Protective Devices – terminate current flow in a circuit.  Located in series within a circuit  Excessive current flow results from.
Introduction To Programmable Logic Controllers
October, 2009 VM1: innovation in power technology Vacuum circuit-breaker with magnetic actuator Product presentation 1VCP – Rev. C, en – Presentation.
Delta Confidential DES UPS introduction UPS training June 2006 Markus Schwab.
Electrical Fundamentals
Welcome DIN Rail product training ISOLATOR/MCB/RCD/RCBO
Chapter 8 Output Modules.
Digital I/O Connecting to the Outside World
PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
Module 2: Hardware and Terminology
Pump Application Interface. 30 October 2006 Overview Increases the functionality of the soft starter for pumping applications - four additional trip inputs.
PROGRAMMABLE LOGIC CONTROLLER (PLC) AND AUTOMATION
Rocker Switches  Available in illuminated, Non-illuminated and Central illuminated version  Suitable for switching resistive and inductive load  Wide.
Troubleshooting Electric Control Devices
MICE Decay Solenoid Quench Detector Trevor Hartnett Daresbury Laboratory.
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
Electrical Distribution Training
MonoDrive & XT Constant Pressure Controller
LP Series U Technical presentation ISO 9001 UL CUL FCC Class A CE.
NSTX Centerstack Upgrade: initial discussions of the Machine Protection System (MPS) Robert Woolley 4 November 2009.
THE PERFECT LIFTGATE BATTERY CHARGING SYSTEM FOR RYDER
Serial Transmission System Series EX510 BackgroundFeaturesTechnical detailsApplications.
FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design.
Why HIPPS ?? We have 600# (high pressure bearing) pipeline from well pads till production header. After that, we have 150# (low pressure bearing) pipeline.
RL BLU BUrners TRAining CEntre. RL BLU BUrners TRAining CEntre CONTROL BOX LOA B27 FEATURES: #Electrical protection IP 40 #Electrical.
SmartMQn Motor Protective Functions Ken Jannotta Jr. Horner APG, LLC.
Esbe Rotary Motorized valves The ESBE Rotary Motorized valves (mixing valves and actuators) are used to control heating and cooling in buildings. We offer.
Opto Couplers Types And Its Applications. Opto Couplers Types And Its Applications Introduction:  A lot of electronic equipment.
MCB Connor, Sunny, Kia. What does it do? A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from.
DC/DC Converter. Innovative products for industrial automation Stabilize control voltages in 24 V DC systems Compact and powerful DC/DC converters for.
PRO-H Power Supplies. PRO-H Series  P owerful R eliable O ptimized - H azardous Areas  Complete family of Power Supplies 1-phase 3.8A up to 25A  Output.
ESX10-T Electronic Circuit Protectors with Hazardous Area approvals.
SOLID STATE RELAYS are used to produce reliable signal and to avoid expensive relay replacement.
Technical Panel Session. Sunday January 11, DC System Failure Modes IEEE PES SBC Winter Meeting. January 11 – 15, New Orleans, LA Part 3.
DC Machine & Transformer
 The figure below shows a protection system for a transmission line, consisting of a CT, PT, a relay and its associated circuit breaker.
Electromechanical Relays Mechatronics ECE 5320 Assignment #1 Paul Smart.
VMCL ELECTRONIC DIVISION.
SPD II 1 for LV Power (AC/DC)
v1/2011 Strikesorb Protection Solutions
Avaya VA Line-interactive UPS
E2 Motors and Motor Starting
Technology The All In One range “dc UPS Power Supply” is based on two strategic know-how elements Switching technology Adel system has a 20 year experience.
Introduction; iMCB a safety monitoring and energy management system, with smart disconnect features. It has a short circuit protection, leakage protection,
IF13 series: Power cord with Input EMC Filter
EET 323 – Electrical System Design Lecture 9: Grounding
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
ACOE347 – Data Acquisition and Automation Systems
PSS0 Design & Concept of Operations
PowerLogic™ offer for the basic metering market
Author Team Supervisor A. Toral M. Mansouri S.L. Birch Y.K. Sin
Electrical components and systems
Technology The All In One range “dc UPS Power Supply” is based on two strategic know-how elements Switching technology Adel system has a 20 year experience.
Fluid Power System Electrical Control
Presentation transcript:

one solution, many application Integrated Electronic Solution PowerSupply Flex

ONE SOLUTION, MANY APPLICATION Flex Power Supply Based on Semi-resonant Switching Technology: high performance till 93% and highly dynamic output power. Very compact in size and cost-effective, they are the perfect choice when power supply is needed for electronic loads, PLCs, sensors, resistive, inductive and capacitive loads. One single article in your stock suits all input voltage options. High reliability and durability: MTBF values up to hours. 3 years Warranty.

ONE SOLUTION, MANY APPLICATION Products Range Out: 24 Vdc Model Output Current A 40°C Input Voltage Vac Output voltage Vdc FLEX6024A FLEX9024A FLEX17024A FLEX28024A FLEX50024A FLEX9024B FLEX17024B FLEX28024B FLEX50024B ph24

ONE SOLUTION, MANY APPLICATION Products Range Out: 5, 12, 48 Vdc Model Output Current A 40°C Input Voltage Vac Output voltage Vdc FLEX6005A5115 – 2305 FLEX6012A6115 – FLEX17012A12115 – FLEX28012A17115 – FLEX17048A3,75115 – FLEX28048B7115 – FLEX50048B12115 – 23048

ONE SOLUTION, MANY APPLICATION Main Flexibility input voltage FLEX Products 90, 170 and 280 B, can be used with the most common mains voltage input It simplifies stock management.

ONE SOLUTION, MANY APPLICATION More Power: “Power Boost” As an example, Flex17024A is a 24Vdc power supply that features a continuous duty current of 5A at 60°C and a Power Boost of 150%, equivalent to 7,5A, for at least 3 min. This features allows the use of a smaller size unit to power demanding loads such as motors solenoid valves, lamps and other loads with transient overload behavior which would otherwise require an oversize power supply.

ONE SOLUTION, MANY APPLICATION More Power at varying rated temperature Do you need more current? Do you need a wider operating temperature range? FLEX fits all applications ! As an example, Flex17024A can be the right solution for two design cases in very different temperature conditions 7.5A, 24Vdc in continuous duty at 40°C 5A, 24Vdc in continuous duty at 60°C + Power Boost 7,5 for at least 3 min.

ONE SOLUTION, MANY APPLICATION Hiccup Mode: Automatic Restart This is the default factory setting of all FLEX units. In case of short-circuit or overloading, the output current is interrupted. The device tries again to re-establish output voltage and normal condition about every 2 second till the problem is cleared. Jumper settings

ONE SOLUTION, MANY APPLICATION Manual Reset: restart by operator In case of short-circuit or overloading, the output current is interrupted. In order to restart the output it is necessary to switch-off the input circuit for about 1 minute. This protection mode is particularly suggested in applications where safety procedures require that reset be carried out only by an authorized person. Jumper settings

ONE SOLUTION, MANY APPLICATION Continuous Output Mode In case of short-circuit or overload, the output current is kept at high values with near zero voltage. In case of short circuit the current can reach up to 3 times the rated current at 60°C This protection mode is used to meet the requirements of demanding loads such as motors, solenoid valves, lamps, PLC with highly capacitive input circuits and other loads with marked transient overload behavior. Jumper settings

ONE SOLUTION, MANY APPLICATION “Power Good” relay Monitoring the Output Voltage Level Output voltage is continuously monitored. The units FLEX90, 170, 280, 500 are equipped with Power Good relay. The NO contact triggers any time the output voltage level goes below 20 Vdc. This feature is particularly useful in redundant applications.

ONE SOLUTION, MANY APPLICATION Output circuits protected by Magneto-thermal circuit breakers Standard output circuit breakers can be triggered quickly and reliably with FLEX technology, which allows three times the nominal current at 60°C. Defective current paths are selectively disconnected, the defect is limited and the important parts of the system remain in operation. This together with the 50% overload capacity in compliance with EN allows to safely manage any overload and short circuit condition.

ONE SOLUTION, MANY APPLICATION FLEX Meets EN Regulation FLEX units comply with the norm requirement that an overload of 50% over the nominal current be withstand by the power supply for at least 1 hour to allow the tripping of magnetothermic switches on the output. These features allows the implementation of “Control of commands and Emergency stops” by means of industrial PCs, PLC, remote I/O, etc. required by norm. Adelsystem supplies a table for the sizing and lenght of connecting cables and the choice of proper magneto- thermic switches.

ONE SOLUTION, MANY APPLICATION Easy parallel connection Whit FLEX technology it is easier to double capacity. The units FLEX280 and FLEX500 can be easily connected in parallel without needing high precision instruments, but a normal tester. Just remove the jumper and trick is done!

ONE SOLUTION, MANY APPLICATION Very small dimensions The higher performances obtained with the FLEX line, allow almost half dimensions as conventional technology and higher performances. An example is Flex6024A 60W with maximum current till 6A. In permanent duty at 40°C it can deliver 3A at 24Vdc. Actually Power supply in the market Flex 6024A

ONE SOLUTION, MANY APPLICATION Norms & Certifications The FLEX series complies with the most demanding current norms and standards. FLEX devices are conforming with: cULus listed 508 approved: all range 24 Vdc output UL 508 conform: for range 5, 12, 48 Vdc output 89/336/EEC EMC Directive 2006/95/EC (Low Voltage) Emission: IEC Immunity: IEC

ONE SOLUTION, MANY APPLICATION