EL SCADA Components Rad Tests EL SCADA components Radiation Resistance Tests Typical US/RE system components.

Slides:



Advertisements
Similar presentations
Modems Telemetry Products Intelligent Modems. Modems  1. What is an intelligent Modem?  2. Where can they be applied?  3. Are they easy to install?
Advertisements

Wireless Controllers. Building block for remote control & alarming Functions Local control Measurement SMS alarming Remote control via SMS Data transmission.
Supervisory Control & Data Acquisition DAQ Networking.
ModCon® 75 Controller.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Poseidon 4002 Rack monitoring 1. Poseidon: Monitor & Control 2.
Modular Capacity - Test - System CS
BPS12 Battery Power Supply. December 2003 Page 2 Better Than Standard UPS systems Longer battery life –unique charging scheme DC power output –instead.
GS3055-I GSM Universal Wireless Alarm Communicator
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
E VERY L IFE H AS A P URPOSE… Flame Detection Theory.
PICNIC Demo Module 2 IP-based utility outlets 陳育瑋、方煒 台大生機系.
Part 1: Introduction FRC Introduction  FRC 2907 since 2008  Each area of the robot has a team assigned  The Electronics team is headed this year.
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
ATM FALCON Product Presentation ATecoM GmbH Pascalstr. 67 D Aachen Germany.
File/ 1 Primary colours Secondary colours Remember to change file name 28pt Ariel bold 18pt Ariel bold l Distributed PID Control and I/O What is.
Contents 1 Seismic, Earthquake and Structural Monitoring System (CR-5P), 25/05/ CR-5P Seismic, Earthquake and Structural Monitoring.
DP Cabinet.
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
G GE Power Management MMII Intelligent MCC Controller.
 A system consisting of a number of remote terminal units (or RTUs) collecting field data connected back to a master station via a communications system.
Programmable Logic Controller
EL SCADA Components Rad Tests Radiation Resistance Tests of EL SCADA components typically installed in US/UJ/RE G. Burdet, EN/EL/CO, 24 August 2010.
Phaseo Power Supplies ACE Expert Training Presentation 2009.
The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels.
PM-RS / March Industrial CMC. PM-RS / March Industrial CMC III Where did it start? Where is it headed? Rittal supplies infrastructure for.
Team Members Jordan Bennett Kyle Schultz Min Jae Lee Kevin Yeh.
1 Modular DC/DC Converter. 2 PSC W Standard 19“ rack 4U – 6 prewired slots (single DC input/output connection for each unit)
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
Gas Monitor Management 氣體監測管理 GAS MONITORING SYSTEM DESIGN HARDWARE SOFTWARE SYSTEM COMMUNICATION.
June 2008 R&D Center / BCS HW Team Introduction to iPECS P5 Hardware.
1 Industrial Systems A dvanced L ine P rotection S ystem.
Overview of the 1.
2500 Series ® Compact I/O System. Where does Compact I/O fit? – When 2500 Series ® “Classic” system is too large to fit the application – When fewer I/O.
SCADA and Telemetry Presented By:.
Mini8 Multi-loop Controller. 2 Eurotherm Business Group Mini 8 – What is it? Multi-loop(4,8,16) PID controller 8-32 Channel data acquisition Design targeted.
TF Joint Voltage Drop Instrumentation Robert Marsala (609) Hans Schneider (609) Engineering Operations August 7, 2003 TF_JOINT_Final_Design_Review.ppt.
A* candidate for the power supply Wiener MPOD-LV crate w/ remote control only (except for local on/off switch) Type “EC LV” Front or rear connections (reverse.
Arctic Control Introduction V 1.0. Arctic Control The Arctic Control is a device with integrated wireless communications for controlling medium-voltage.
IRRInet & ICC System Concept
SCADA FOR WATER DISTRIBUTION IC DEPT. GECGn SEC28.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
E1 / T1 Series Product Introduction.
Modular Inverter.
TYPICAL SCADA SYSTEM FIELD UNIT SCADA H/W & S/W C TX O RX M E M Q N P
Unit 5 CONTROL CENTERS AND POWER SYSTEM SECURITY.
Safe-Room Status Intermediate ‘Conclusions’ M. Brugger (based on HSE discussion)
Hardware Training Product: ITMS2.
Programmable Logic Controller (PLC)
Interactive Control in Engineering Projects Electronics and Control.
The D50 Is a state of the art environmental monitor using only the best quality components available. It offers multiple sensors in a single unit with.
NERC Lessons Learned Summary LLs Published in September 2015.
J. MEKKI (1/8) 06/03/12 – RadWG meeting CNRAD plan Beam schedule – 1 st Slot Overall beam schedule for 2012 Equipments to be installed o Higher flux locations.
18240 Element two - Components INPUTS OUTPUTS PURPOSE TYPICAL USE.
PRESENTATION. Parts of the PCOS (3) Operator LCD Screen with Counter (4) Printer Compartment (5) Transmission Port (9) “RETURN” Button (8) “CAST” Button.
FLATPACK Rev.5 September 2002 Updated versions may be available.
COMPUTER COMPONENTS Ms Jennifer Computer Components.
1 Data Acquisition, Monitoring & Management Solutions Supplied by DCM Transcal Phone or
DIGITAL MULTIMETER DMG
2500 Series® Compact System Components
Lindab UltraLink The only thing you cannot measure is its potential
FEEDER PROTECTION UNIT
2500 Series® Compact System Components
2500 Series® Compact System Components
Module 1 – Power Supply AMC APS-PBC-60
ACOE347 – Data Acquisition and Automation Systems
GasGard 100 Control System
Presentation transcript:

EL SCADA Components Rad Tests EL SCADA components Radiation Resistance Tests Typical US/RE system components

Typical US/RE installation: –RTU: CLP500E EFACEC Advantech Diskless board Power Supply module, 48VDC Supply –DAU, 48VDC Supply CPU/Communication: MAP3200 Prometheus Input MAP3020, Output MAP3050 Analogues MAP3080 –IED, DIRIS Ap, 48VDC Supply (Low Voltage Switchboards) –Adapters, 24VDC Supply ADAM 4520: RS232/RS485 Switch MOXA EDS308 ELECDAN Power Converter 48/24VDC ELECDAN Pt100/10V Converter ELECDAN Counter/10V Converter (Ackerman Battery Measurement) Acquisition of Voltage Relay EL SCADA Components Rad Tests

Monitoring: –Remote Desktop Connection to connect to RTU CLP500 Version managing the system Daily Control execution in List Mode –Automatism (Fung function) Return on Input board makes events & Alarm Reaction in case of failure (SEE) –Remote Reboot RTU level (if RDC & ping failure) DAU level (if IEC-Down & Win 3200 failure) 24VDC convertor (Switch, ADAM4520, ELECDAN convertors) DIRIS module (if Communication or measurements lost) EL SCADA Components Rad Tests

Power Supply 230/48VDC 6Amp Power Supply 230/48VDC 6Amp Ethernet GPN Ethernet GPN Remote Reboot Remote Reboot RT RR 230VAC 48VDC Jbus/RS485 Win3200/RS /TCP/IP Remote Desktop Connexion RR 24VDC RTU CLP500E DAU MAP3200 MAP3020/50/80 DAU MAP3200 MAP3020/50/80 ADAM 4520 RS232/RS485 ADAM 4520 RS232/RS485 DIRIS Ap ELECDAN Counters ELECDAN Counters ELECDAN Pt100 ELECDAN Pt100 ELECDAN Converter 48/24VDC ELECDAN Converter 48/24VDC Switch SPHINX EDS308 Switch SPHINX EDS308

RTU CLP500E DIRIS Ap RTU CLP500E Switch SPHINX EDS308 Switch SPHINX EDS308 Power Supply 230/48VDC 6Amp Power Supply 230/48VDC 6Amp Converter 48/24VDC Converter 48/24VDC Switch SPHINX EDS308 Switch SPHINX EDS308 Switch SPHINX EDS308 Switch SPHINX EDS308 ADAM 4520 ADAM 4520 ADAM 4520 ADAM 4520 DIRIS Ap Converter 48/24VDC Converter 48/24VDC Converter 48/24VDC Converter 48/24VDC Ethernet GPN Ethernet GPN Remote Reboot Remote Reboot DIRIS Ap RT RR 230VAC 48VDC ADAM 4520 ADAM 4520 ADAM408 0 & Pt100 ADAM408 0 & Pt100 ADAM408 0 & Pt100 ADAM408 0 & Pt100 ADAM408 0 & Pt100 ADAM408 0 & Pt100 DAU MAP3200 MAP3020/50/80 DAU MAP3200 MAP3020/50/80 DAU MAP3200 MAP3020/50/80 DAU MAP3200 MAP3020/50/80 DAU MAP3200 MAP3020/50/80 DAU MAP3200 MAP3020/50/80 Jbus/RS485 Win3200/RS /TCP/IP Remote Desktop Connexion RR ELECDAN Counters ELECDAN Counters ELECDAN Counters ELECDAN Counters ELECDAN Counters ELECDAN Counters

EL SCADA Components Rad Tests Mechanical design –No extra shielding, Light rack mounting Statistics –3 systems in // –Permanent monitoring –Human daily check Costs –Components: 20kCHF –Work: 10kCHF Conditions –Activated material –Not repairable –Not re-usable Schedule –CNGS TSG46 –Time slot to be defined Rack Front viewRack Back view

EL SCADA Components Rad Tests