C ompensating H adron C alorimetry C ompensating H adron C alorimetry Why do we need it? How it may work? Does it really work? If not, can we survive?

Slides:



Advertisements
Similar presentations
Experimental Particle Physics
Advertisements

Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
DREAM Collaboration: Recent Results on Dual Readout Calorimetry. F.Lacava for the DREAM Collaboration Cagliari – Cosenza – Iowa State – Pavia – Pisa –
Particle interactions and detectors
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
Testbeam Requirements for LC Calorimetry S. R. Magill for the Calorimetry Working Group Physics/Detector Goals for LC Calorimetry E-flow implications for.
Calorimetry and Showers Learning Objectives Understand the basic operation of a calorimeter (Measure the energy of a particle, and in the process, destroy.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Directional Detectors and Digital Calorimeters Ed Norbeck and Yasar Onel University of Iowa For the 25 th Winter Workshop on Nuclear Dynamics Big Sky,
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
New Calorimeter Technologies for NLC (a) Secondary Emission Calorimeter Sensors (b) Cerenkov Compensated Precision Calorimetry Y.Onel, University of Iowa.
Calorimetry: Energy Measurements
Application of Neural Networks for Energy Reconstruction J. Damgov and L. Litov University of Sofia.
Calorimeters A User’s Guide Elizabeth Dusinberre, Matthew Norman, Sean Simon October 28, 2006.
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
Mauricio Barbi University of Regina TRIUMF Summer Institute July 2007
Status of EIC Calorimeter R&D at BNL EIC Detector R&D Committee Meeting January 13, 2014 S.Boose, J.Haggerty, E.Kistenev, E,Mannel, S.Stoll, C.Woody PHENIX.
Status of Atlas Tile Calorimeter and Study of Muon Interactions L. Price for TileCal community Short Overview of the TileCal Project mechanics instrumentation.
KamLAND Experiment Kamioka Liquid scintillator Anti-Neutrino Detector - Largest low-energy anti-neutrino detector built so far - Located at the site of.
Lecture 1.3: Interaction of Radiation with Matter
LHC Detectors 101 Vivek Sharma (with slides stolen from talks of several people ) 1 Good review article: ARNPS 2006, “General purpose detectors for large.
R&D on W-SciFi Calorimeters for EIC at Brookhaven E.Kistenev, S.Stoll, A.Sukhanov, C.Woody PHENIX Group E.Aschenauer and S.Fazio Spin and EIC Group Physics.
Particle Detectors for Colliders Calorimeters Robert S. Orr University of Toronto.
The Tungsten-Scintillating Fiber Accordion Electromagnetic Calorimeter for the sPHENIX Detector Craig Woody, for the PHENIX Collaboration Physics Department,
CMS Calorimeter HB- HB+ HE- HE+ HF- HF+ HO-2 HO-1 HO0 HO+1 HO+2
Calorimeters Chapter 4 Chapter 4 Electromagnetic Showers.
Experimental Particle Physics PHYS6011 Joel Goldstein, RAL 1.Introduction & Accelerators 2.Particle Interactions and Detectors (2/2) 3.Collider Experiments.
NESTOR SIMULATION TOOLS AND METHODS Antonis Leisos Hellenic Open University Vlvnt Workhop.
STUDY OF ULTRAREAR DECAYS K 0 → π 0 νν(bar) (Search of K 0 → π 0 νν(bar) decay at IHEP, project KLOD ) V.N. Bolotov on behalf of the collaboration JINR,
ECAL PID1 Particle identification in ECAL Yuri Kharlov, Alexander Artamonov IHEP, Protvino CBM collaboration meeting
Results from particle beam tests of the ATLAS liquid argon endcap calorimeters Beam test setup Signal reconstruction Response to electrons  Electromagnetic.
1 Methods of Experimental Particle Physics Alexei Safonov Lecture #15.
Particle Detectors for Colliders Robert S. Orr University of Toronto.
Interactions of Hadrons and Hadronic Showers
DESY Beam Test of a EM Calorimeter Prototype with Extruded Scintillator Strips DongHee Kim Kyungpook National University Daegu, South Korea.
ILC Calorimetry Test Beam Status Lei Xia ANL HEP.
18-23 July 2006J. Hauptman Vancouver LCW06 4th Calorimeter Plans (or dual readout is wonderful, but what are its problems) 1. Electrons and photons limited.
4th Concept Pixel Vertex (PX) 20-micron pixels (like Fermilab/SiD thin pixel) TPC (like GLD or LDC) with “gaseous club sandwich” Triple-readout fiber calorimeter:
R.S. Orr 2009 TRIUMF Summer Institute
Rare decay Opportunities at U-70 Accelerator (IHEP, Protvino) Experiment KLOD Joint Project : IHEP,Protvino JINR,Dubna INR, Moscow, RAS.
CaTS and Dual Readout. CaTS – Calorimeter and Tracker Simulation Describe detector in gdml file (xml like) Define.
A Fourth Detector Concept (no name, yet) Silicon Vertex: 3-4 layers, conventional Tracking TPC: 1 atm, moderate B field Calorimeter: measure all main fluctuations,
DESY Beam Test of a EM Calorimeter Prototype with Extruded Strip Scintillator DongHee Kim Kyungpook National University Daegu, South Korea.
APS April2000 Meeting Ahmet Sedat Ayan Dept. of Physics & Astronomy University of Iowa.
SPHENIX EMCAL R&D Craig Woody BNL sPHENIX Design Study Meeting September 7, 2011.
Geant4 Tutorial, Oct28 th 2003V. Daniel Elvira Geant4 Simulation of the CMS 2002 Hcal Test Beam V. Daniel Elvira Geant4 Tutorial.
Adam Para, Fermilab, February 16, Who Cares? What is the Problem? 2 Dual Readout Total Absorption calorimeter has very good energy resolution.
Imaging Hadron Calorimeters for Future Lepton Colliders José Repond Argonne National Laboratory 13 th Vienna Conference on Instrumentation Vienna University.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
Simulation studies of total absorption calorimeter Development of heavy crystals for scintillation and cherenkov readout Dual readout in the 4 th concept.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
DE/dx in ATLAS TILECAL Els Koffeman Atlas/Nikhef Sources: PDG DRDC (1995) report RD34 collaboration CERN-PPE
Simulation and reconstruction of CLAS12 Electromagnetic Calorimeter in GSIM12 S. Stepanyan (JLAB), N. Dashyan (YerPhI) CLAS12 Detector workshop, February.
Part II: Calorimeter Technologies
Calorimeters at CBM A. Ivashkin INR, Moscow.
Where are we? What do we want to do next? Some thoughts
Calorimetry and Cherenkov Radiation
PHYS 3446 – Lecture #14 Energy Deposition in Media Particle Detection
State-of-the-art in Hadronic Calorimetry for the Lepton Collider
Dual-Readout Calorimeter: DREAM
Alternative CEPC Calorimeter
Experimental Particle Physics
Separation of Scintillation and Cerenkov Light
Reports for highly granular hadron calorimeter using software compensation techniques Bing Liu SJTU February 25, 2019.
Dual readout calorimeter for CepC
Experimental Particle Physics
PHYS 3446 – Lecture #17 Particle Detection Particle Accelerators
PHYS 3446 – Lecture #18 Monday ,April 9, 2012 Dr. Brandt Calorimeter
PHYS 3446 – Lecture #14 Energy Deposition in Media Particle Detection
Presentation transcript:

C ompensating H adron C alorimetry C ompensating H adron C alorimetry Why do we need it? How it may work? Does it really work? If not, can we survive? Aldo Penzo, INFN-Trieste FERMILAB - Research Techniques Seminar – Aug. 9, 2007

What kind of talk? Not a general “review”… Rather an account of – “episodes” in Calorimetry R&D – examples of “compensation” methods Therefore… – only partial coverage of the topic – (necessarily) subjective – (hopefully) not too biased Purpose: outline the changing scope of what is called “compensation”

Joule's apparatus for measuring the mechanical equivalent of heat in which the "work" of a falling weight is converted into the "heat" of agitation in the water. No need of high-tech for a good result...

... just go for it! Take the best data you can Reconfigurable-stack calorimeter “Hanging File”: Scintillator-Absorber plates

Shower development and energy measurement

What’s going on in a developing shower? Everything that can be found in standard textbooks on Radiation Interactions in Matter (f.i. Landau-Lifschitz, Bruno Rossi, etc.) Photons/electrons undergo EM interactions and produce EM showers

Hadrons interact strongly and produce hadronic cascades copiously produced  o generate  pairs, originating EM showers inside hadronic cascades 2 scales for hadronic cascade development: –  abs for strongly interacting part – Xo for the EM part hadron  

2 scales of shower development X0X0 I X 0, λ I [cm] Z

Development of hadron cascade Large fluctuations due to  o production

Dominance of low energy particles

Lateral cascade distribution Lead- scintillating fibre calorimeter The EM Component more concentrated on the central part of the shower: EM core

Hadronic vs EM response For instance in lead (Pb): Nuclear break-up (invisible) energy: 42% Ionization energy: 43% Slow neutrons (E ~ 1 MeV): 12% Low energy  ’s (E γ ~ 1 MeV): 3% Not all hadronic energy is “visible”:  Lost nuclear binding energy  neutrino energy  Slow neutrons, …

Hadronic shower reduced vs EM (and much broader) e/h = 1/

Interim outline High precision hadron calorimeters should have equal response to electromagnetic and strongly interacting particles (compensation condition e/h =1) in showers generated by incoming hadrons, in order to achieve: linear response in energy to hadrons, gaussian energy distribution for mono-energetic hadrons, electron-to-pion ratio close to unity, constant with energy, relative energy resolution (dE/E), improving as sqrt(1/E). This is of prime relevance for the measurement of jets, involving various particles of different energies, with a substantial fraction of neutral pions..

In practice… Significant episodes of the straggle for compensation in hadron calorimetry will be summarized and different methods will be compared. Recent progress aiming to differentiate and separately measure the shower products (interacting electromagnetically or strongly) will be discussed and technological solutions outlined

Compensation methods (mainly sampling calorimeters) Intrinsic compensation: Recover part of the “invisible energy” Decrease the electromagnetic contribution (often using composite passive materials) Off-line compensation: Weighting methods Multiple shower measurements (with 2 or more active media, selective to EM,etc)

High Z material as absorber Full compensation can be achieved with high Z material; large part of EM components will be deposited in absorber decreasing the EM energy deposition in active medium Tuning the thickness of the absorber and active layer High - absorber that can partially recover the invisible hadronic energy via nuclear and collisions processes.

238U as passive, scintillator as active media. 238U: Absorber with high Z decreases EM response; Slow neutrons induce fission in the 238U, that compensates losses due to “invisible” energy Slow neutrons can be captured in the nucleus of 238U which emits a low energy γ’s and can further recover the “invisible” energy Scintillator: Slow neutrons loose their kinetic energy via elastic collisions with hydrogen in the scintillator (LAr - Fabjan, Willis, 1977)

Zeus U-scintillator Calorimeter Had EM

Response for e/h = 1 If e/h = 1 than: Hadron response linear Energy distribution “Poisson” Statistical fluctuations Constant term (calibration, non-linearity, etc Noise, etc

Tuning Pb thickness for e/  =1

So much about scintillator calorimeters: I will revisit later on… Now let’s turn to Si detectors in calorimetry: it so happened that such systems gave precise and interesting data on very detailed compensation effects…

1983: Si-W EM prototype 24 Xo’s tungsten; 12 Si detectors (5x5cm) EM

SICAPO: Silicon Calorimeter Another hanging file reconfigurable calorimeter prototype

Large scale SICAPO test calorimeter The calorimeter vessel could accommodate: the Si mosaic detector planes and a number of absorbers between the detector planes The passive plates were W, Pb (High Z) as well as Fe, …,G10 (Low Z) (arranged in any desired configuration) The readout of this calorimeter consisted of 30 mosaic planes (of about 1600 cm 2 active area) each made of 400 silicon detectors. A detector had an area of about 4 cm 2, is 400  m thick, and operated at full depletion.

Support plate for Si detectors

Assembling the Si detectors

Tuning of absorbers for SICAPO The passive plates’ configuration could be arranged in order to achieve: local hardening effect (introducing thin low Z sheets near the detector’s planes) filtering effect (by using combinations of High and Low Z absorbers)

Hardening G10 plates inserted close to the detector planes….

Filtering PbFe–Si–PbFe configuration as a function of the thickness of Pb in the absorber (the overall absorber thickness, including the Fe plates is 23 mm).

Resolution for U-scint. Cal.

Evidence for Compensation in a Si Hadron Calorimeter E. Borchi, M. Bosetti, C. Leroy, S. Pensotti, A. Penzo, P.G. Rancoita, M. Rattagi, G. Terzi IEEE TRANS. ON NUCLEAR SCIENCE, 40 (1993)

Resolution vs sampling step

Linearity for Scintillator Cal.

Energy Resolution (for Scint. Cal.)

Offspring: PAMELA

Another example: in this case highly non-compensating In a quest for rad-hard materials as active parts for calorimetry, quartz fibers Only Cerenkov light, only (low energy) e+/-

The HF calorimeter Steel absorber with embedded fused-silica-core optical fibers where Cherenkov radiation forms the basis of signal generation. Thus, the detector is essentially sensitive only to the electromagnetic shower core and is highly non-compensating (e/h 5). Above Cherenkov threshold (E = 190 keV for electrons) they generate Cherenkov light, thereby rendering the calorimeter mostly sensitive to the electromagnetic component of showers.

CMS – HF: A full-scale technological benchmark Quartz Fiber Calorimeter ~ 1000 km quartz fibers 1 HF weights ~ 250 tons PMT readout (magn. field ~ 0 ) Co 60 source calibration ≤ 5%

 /e values for SPACAL and HF

Resolution of HF The electromagnetic energy resolution is dominated by photoelectron statistics and can be expressed in the customary form. The stochastic term a = 198% and the constant term b = 9%. The hadronic energy resolution is largely determined by the fluctuations in the neutral pion production in showers, and when it is expressed as in the electromagnetic case, a = 280% and b = 11%.

- Beam test results from a fine-sampling quartz fiber calorimeter for electron, photon and hadron detection - N. Akchurin et al.- Nucl.Instrum.Meth.A399: , Test beam results of CMS quartz fibre calorimeter prototype and simulation of response to high-energy hadron jets - N. Akchurin et al. - Nucl.Instrum.Meth.A409: ,1998 -On the differences between high-energy proton and pion showers and their signals in a non-compensating calorimeter - N. Akchurin et al. - Nucl.Instrum.Meth.A408: ,1998 CMS NOTE 2006/044 - Design, Performance, and Calibration of CMS Forward Calorimeter Wedges, G. Baiatian et al.

The challenge…. Mockett 1983 SLAC Summer Institute A technique is needed that is sensitive to the relative fraction of electromagnetic energy and hadronic energy deposited by the shower. This could be done hypothetically if the energy were sampled by two media: one which was sensitive to the beta equals one electrons and another which was sensitive to both the electrons and other charged particles. For example one sampler could be lucite which is sensitive only to the fast particles, while the other sampler could be scintillator. See also Erik Ramberg et al., Dave Winn et al., … ….and the DREAM…

Main theme: multiple measurements of every shower to suppress fluctuations Spatial changes in density of local energy deposit Fluctuations in EM fraction of total shower energy Binding energy losses from nuclear break-up fine spatial sampling with SciFi every 2mm clear fibers measuring only EM component of shower via Cherenkov light from electrons (E th = 0.25 MeV) measure MeV neutron component of shower. Like SPACAL Like HF Triple Readout DREAM = SPACAL + HF

1)Muon detection with a dual-readout calorimeter. N. Akchurin, K. Carrell, J. Hauptman, H. Kim, H.P. Paar, A. Penzo, R. Thomas, R. Wigmans - Nucl.Instrum.Meth.A533: ,2004 2) Electron detection with a dual-readout calorimeter. N. Akchurin, K. Carrell, H. Kim, R. Thomas, R. Wigmans, J. Hauptman, H.P. Paar, A. Penzo - Nucl.Instrum.Meth.A536:29-51,2005 3) Hadron and jet detection with a dual-readout calorimeter. N. Akchurin, K. Carrell, J. Hauptman, H. Kim, H.P. Paar, A. Penzo, R. Thomas, R. Wigmans - Nucl.Instrum.Meth.A537: ,2005 4) Separation of scintillation and Cherenkov light in an optical calorimeter. N. Akchurin, O. Atramentov, K. Carrell, K.Z. Gumus, J. Hauptman, H. Kim, H.P. Paar, A. Penzo, R. Wigmans - Nucl.Instrum.Meth.A550: ,2005 5) Comparison of High-Energy Electromagnetic Shower Profiles Measured with Scintillation and Cherenkov Light. N. Akchurin, K. Carrell, J. Hauptman, H. Kim, A. Penzo, R. Thomas and R. Wigmans - Nucl.Instrum.Meth.A548: ,2005 DREAM Published Results (

DREAM [Dual REAdout Module] prototype is 1.5 ton heavy Cell [basic element of detector] 2m long extruded copper rod, [4 mm x 4 mm]; 2.5mm hole contains 7 fibers:3 scintillator & 4 quartz(or acrylic plastic). In total, 5580 copper rods (1130Kg) and 90 km optical fibers. Composition (volume) Cu: S : Q : air = 69.3 : 9.4 :12.6 : 8.7 (%) Effective Rad. length (X 0 )=20.1mm;Moliere radius(r M )=20.35mm Nuclear Inter. length ( int )=200mm;10 int depth Cu. Filling fraction = 31.7%; Sampling fraction = 2.1% (S, Q fibers 0.8 mm  )

Fig. a : fiber bundles for read-out PMT; 38 bundles of fibers Fig b : front face of detector with rear end illuminated: shows 3 rings of honey-comb hexagonal structure..  Tower : readout unit Hexagonal shape with 270 cells (Fig. b); Readout 2 types of fibers to PMTs (PMT: Hamamatsu R580) (Fig. a)  Detector : 3 groups of towers (Fig. b) center(1), inner(6) & outer(12) rings; Signals of 19 towers routed to 38 PMT Effective radius 162 mm (0.8 int, 8 r M )

Test Beam Results c) d) a), b) energy distributions from scintillating and Cerenkov fibers for 100GeV single  - asymmetric, broad, smaller signal than e - typical features of non-comp. calorimeter. c) energy resolution (%) vs beam energy d) Scintillation signal response vs energy

After (Q+S)/E correction, the signal distributions are described well by gaussian distribution and energy resolution was dramatically improved. ( 12.3% resolution became 2.6% for 100GeV  beam). ( Fig. a & b) Energy resolution as a function of beam energy(Fig. c) are well described by E    a b E 1/2 ( b is related to sampling non-uniformity depending on impact point of the beam. ) c)

DREAM calibrated with 40 GeV e - into center of each tower, recover linear hadronic response up to 300 GeV for  - and “jets”

b. Method using the directionality of Cerenkov light Measure the light from both ends of fibers (F and B). B/F = ratio of light emitted in the backward and forward. Clear difference was found in B/F ratio between Cerenkov and scintillation light. Scintillation light is generated isotropically and only 20% difference in backward and forward signals. Cerenkov light in forward direction is ~6 times larger than in backward direction. B/F ratio for scintillator (a) and Cerenkov (b) signals generated by 80GeV electrons.

New issues and options (Light-Emitting) Active Media Study Xstals, Cerenkov radiators, neutron sensitive scintillators (Photon-Sensing) Detectors Develop SiPM (popular objective… … need good technology partners) (Time-Domain) Signal Processing Fast Pulse Shape digitizer

Compensating Calorimetry might be the art of compromise and balance… …and elegance instead of brute force, like…

Appareil à deux globes de verre inventorié dans les archives de l'Ecole polytechnique comme " appareil de Gay-Lussac " dans la catégorie des " appareils ayant trait à la chaleur "......it was never used for a real measurement....

Maybe go back to really old stuff? Provando e riprovando….