Control Damper Products Manual Balancing Dampers

Slides:



Advertisements
Similar presentations
Pneumatic Valves Lesson 4.
Advertisements

Steel Outlet Boxes Crouse-Hinds Training Module. Outline z Applications z Types of Steel Boxes y Options z Uni-Mount TM Cover z Pre-Fabricated Boxes z.
AIR DISTRIBUTION (Additional information. Also see Chapter 18) General The proper delivery of air for heating, cooling, or ventilation is a crucial part.
Chapter 12 HVAC Controls Pneumatic Control Systems • Air Compressor Stations • Transmitters and Controllers • Pneumatic Thermostats • Auxiliary Components.
Construction Methods and Materials HVACR HVACR. Construction Methods and Materials HVACR Comfort Equipment required to control: Temperature Moisture Air.
Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
Fan Coil Unit Product Line-up. FCU Home Application Show.
Chapter 8: Duct Design and Sealing To be used with the Guide to Building Energy Efficient Homes in Kentucky.
ADX 150 – Engine Repair ADX 170 – Climate Controls
HVAC CONTROLS (See section 18.9)
AIR CONDITIONING ACCESSORIES
Basic Refrigeration Cycle
HVAC Air Flow Measurement The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Unit Eight Check Valves, Cylinders, and Motors
Hydraulic Power Assist
HYDRAULICS & PNEUMATICS
SUPPLY DUCT SYSTEMS (Additional information. Read sections 18.4, 18.5, & 18.6) General –The supply duct system conveys conditioned air from an AHU to the.
1 HVAC SHEET METAL SHEET METAL THEORY. 2 THE AIR DISTRIBUTION SYSTEM SHEET METAL IS USED FOR: – PLENUM’S (RETURN & SUPPLY) –TRUNK LINES –RETURN AIR GRILLS.
Basic Fire and Smoke Training Basic Fire and Smoke Actuators & Dampers.
The Swagelok® SK series and AFS Multipurpose Ball Valves
Air Flow Bench Presented By: Saket Karajgikar & Nikhil Lakhkar Advisor: Prof. Dereje Agonafer.
Backdraft Dampers. Backdraft Damper Training Application Backdraft dampers allow air to flow in one direction only and prevent unwanted (hot/cold outside.
 A 'heat exchanger' may be defined as an equipment which transfers the energy from a hot fluid to a cold fluid. Here, the process of heating or cooling.
MAGSEAL 101. Rotary face seal that utilizes magnetic attraction force to positively mate the optically flat seal faces. Magnetic attraction force variation.
HVACR416 - Design Humidification. Relative Humidity 1.Air in the home is artificially dried out when it is heated. 2.Because warm air expands, this expansion.
GAUGES Gauges perform an essential services in any scheme of quantity production on an interchangeable basis A gauge (or Limit Gauge) is a tool or instrument.
Actuators.
VARIABLE GEOMETRY VAV SYSTEMS: SYSTEM AND DUCT DESIGN CONSIDERATIONS.
AccuMax Multi-Point Injection Mechanics
Hydronic Mechanical Controls
COOLING TOWER Prof. Osama El Masry.
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
HVAC523 Circulator Pumps.
HVACR416 - Design Grills, Registers, and Diffusers.
Chapter 12: Fans and Building Air Distribution
Air Handler Terminology
Single-Point Zoning Damper Choices
INSTALLATION & COMMISSIONING. 5WSS Installation Hanging the Unit Hanging the Unit Location Considerations Location Considerations Refrigerant Piping Refrigerant.
Air Handler Terminology
Improved Precision Leading to Improved Energy Efficiency Edward Decker AE 790 – Intelligent Buildings June 6, 2006.
VAV Box Control Loop The purpose of the VAV Box control loop is to adjust airflow through the box to maintain a space temperature. The difference between.
Motorized Dampers.
HVACR416 - Design Pressure Measurement Part 1. Why Measure? Need to Make Sure: All combustion appliances vent properly All HVAC systems are installed.
Introduction to Energy Management. Week/Lesson 10 Air Moving Equipment: Fans and Ducts.
3.4 Equal friction method This method of sizing is used for supply, exhaust and return air duct system and employs the same friction lose per foot of length.
Esbe Rotary Motorized valves The ESBE Rotary Motorized valves (mixing valves and actuators) are used to control heating and cooling in buildings. We offer.
Valves In Industry (Part 1)
Butterfly Control Valves
AIR CONDITIONING (COOLING) UNIT 37 AIR DISTRIBUTION AND BALANCE
Resolving Common Problems with Developing Louver Catalogs.
Government Engineering College Bharuch(014). Sub: Instrumentation And Process Control. Topic: Displacement float,Pneumatic balance and Magnetic level.
Part 15 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
FRP Industrial Dampers
WE WORK TOGETHER WE WIN TOGETHER
Introduction to hydraulics
Steering Systems Topics covered in this presentation:
HYDRAULICS & PNEUMATICS
Air Distribution Control
Transmission system of Automobile
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
Working Under Pressure
Resolving Common Problems with Developing Louver Catalogs
Fluid Power System Electrical Control
Presentation transcript:

Control Damper Products Manual Balancing Dampers Commercial Control Dampers Industrial Control Dampers

Control Damper Training Application Control Dampers are an integral part of every HVAC system. They are positioned manually or automatically to control air volume and temperature throughout the air handling system. Basic Functions • Volume Control - Regulates airflow. • Temperature Control - Maintains desired temperature. • Pressure Control - Maintains desired pressure. (uncommon)

Volume Control • Branch Dampers Regulates airflow and branches. Control Damper Training Volume Control • Branch Dampers Regulates airflow and branches. • Balancing Dampers Limit flow down the duct or through a device by holding damper blades at a specific position (typically via a manual locking quadrant). • Fan Inlet/Outlet Dampers Used to control flow rate to or from the fan.

Basic Mixing Application Control Damper Training Temperature Control Mixing Dampers • Operate as a pair to maintain temperature. • Simultaneously regulates two different air streams - each with different incoming air temperature. • Able to control air temperature and volume. Basic Mixing Application Basic System Design

Typical Side-by-Side Face & Bypass Application Control Damper Training Temperature Control Face & Bypass/Multi-Zone Dampers • Regulates face air (hot or cold) with bypass/return air to maintain temperature. • Arranged side-by-side, top-bottom, or at right angles. Typical Side-by-Side Face & Bypass Application

Standard Construction Control Damper Training Standard Construction Flat Hat Channel ‘U’ Channel Flanged Control Dampers have different designs and are constructed from a variety of frames, blades, axles, bearings, blade linkage and other parts to suit the particular application for that damper. Frames Flat Hat Channel ‘U’ Channel Flanged

Control Damper Training Blades 3-V Blade • Flat, typically for single-blades dampers, low pressure applications. • Triple-V, economical. Low to medium pressure applications. • Airfoil, lower pressure drop, medium to high pressure applications. Airfoil Blade

Control Damper Training Blade Action Parallel • All blades rotate together in the same direction. • Typically two-position control. Opposed • Adjacent blades rotate in opposite directions. • Balancing and modulating control. Parallel Opposed

Control Damper Training Axles Attached to the damper blade and extend through the damper frame to permit the blades to rotate. • Various sizes, lengths, materials depending upon the application. Bearings Pressed into the damper frame to permit easy rotating Of the damper blade & shaft. • Various types and materials depending upon the application.

Control Damper Training Blade Linkage Mechanism that connects the blades together. • Concealed - hidden within the frame on one side or the other or in rare cases, both sides of the damper. • Exposed - attached to the blade face. Concealed Linkage Exposed Linkage

Damper Drive Mechanism Control Damper Training Damper Drive Mechanism Mechanism that drives (operates) - all the blades together. Typically connected to one blade - Drive Blade. • Direct Drive - typically a shaft extending from one side of the damper adjacent to the damper frame. • Jack Shaft - typically a shaft, offset but connected to the drive blade, extending past the side of the damper- used mostly when connecting multiple single-sectioned dampers together. Direct Drive Jack Shaft

Optional Low Leakage Seals Control Damper Training Optional Low Leakage Seals • Stainless Steel Jamb Seals - positioned between the end of the blades and the inside of the damper frame and blade edge seals attached to the damper blades. Optional Stainless Steel Construction • Typically standard construction material is galvanized steel. Most models have type 304 stainless steel (only), and a few offer 316.

Control Damper Training Design Basics Manual Balancing • Commonly found at duct branches and used to restrict airflow in the branch to the desired level. Commercial Control • Most common type and widely used for volume and temperature control. Industrial • Employed when the temperature, pressure, or velocity exceed standard commercial damper limits. Units are typically flange mounted directly to the duct or fan housing.

Manual Balancing Dampers Control Damper Training Manual Balancing Dampers RCS-10R RCS-10 Concealed Operator Used to control the flow of air to meet a required volume, temperature and/or pressure. Cable Control • Enables remote damper positioning from within the occupied space. • Available for round and square duct. Quadrant Control • Quieter than diffuser mounted OBD. • With or without integral sleeve. • Requires access to set quadrant. CD-10IS CD-10 Hand Quadrant Integral Sleeve CD-10R

Commercial Control Dampers Control Damper Training Commercial Control Dampers Blade Type • 3-V Economical - Galvanized Steel • Airfoil Lower Pressure Drop Galvanized Steel or Aluminum • True-Round Blade Action • Parallel - Blades move together in the same direction - 2-position control • Opposed - Adjacent blades turn in opposite directions - Balancing dampers and modulating control 3-V Blade Airfoil Blade Concealed Linkage Exposed Linkage True Round CD-22R Multi-Blade True Round CD-25R Single Blade Integral Sleeve Drive Shaft

Commercial Control Dampers Control Damper Training Commercial Control Dampers Multiple Sections • Jackshaft • Bracing - As required • Face & Bypass Vertical Blades • Actuator/Quadrant Access • Thrust Washers Jackshaft Drive Shaft Hat Channel Frame Face & Bypass Dampers Note H = Blade Length H

Industrial Control Dampers Control Damper Training Industrial Control Dampers • Employed when temperature pressure or velocity exceeds commercial damper limitations. • Typically are flanged frame construction and mounted directly to the duct or fan housing. Supplied approx. net I.D. • Are controlled by a manual locking quadrant or by an electric or pneumatic actuator. Actuators are external mount only. • Actuators are normally, but not always larger in size (more powerful - larger torque) than those used for Commercial Control Dampers/ Actuators Electric Pneumatic CD-81R CD-82

Industrial Control Dampers Control Damper Training Industrial Control Dampers Blade Type • 3-V • Airfoil (n/a for Pottorff) • True Round Frame Type • Channel Concealed Linkage Channel Frame Continuous Blade Axle CD-81R

No-Sleeve vs. Sleeve No-Sleeve Dampers • 1/4” under nominal size Control Damper Training No-Sleeve vs. Sleeve Side Plate Damper with Side Plate No-Sleeve Dampers • 1/4” under nominal size Side Plate • 12” wide x 16 gauge Sleeved Dampers • 20 gauge sleeve = 1/8” under nominal size, the thicker the sleeve the closer the OD is to nominal size • Optional Transitions: AR (round), AO (oval), AF (Flange) • Labor Saver - Ready to install from factory Damper with Sleeve

Control Damper Training Actuators Actuators control the position of the damper based on signals from the: Building Automation System (BAS), Thermostats & Controllers, Pressure Switches and Relays. NF-120 (Belimo) Electric Actuators LMB24-SR (Belimo) Location • External or Internal Electric • 2-Position Spring Return • Modulating • 24, 120, 230 VAC Pneumatic • 25 psi control signal 331-4826 (Siemens) 331-2998 (Siemens) Pneumatic Actuators

Control Damper Training Actuators Actuator selection is based upon the ability of the actuator to adequately open and close the damper and the amount of torque the actuator can supply. This typically depends upon the following: • Overall damper size. • Velocity of air through the damper. • Static pressure against the damper. • Damper blade type - parallel or opposed: -Normally parallel bladed dampers require more torque to open than opposed but require less torque to close than opposed. • Whether the damper has jamb seals or not. Our dampers are typically rated at 2000fpm and 1” wg.

Actuators Depending upon the damper design, Control Damper Training External Mount Actuators Depending upon the damper design, most actuators can be mounted either internally or externally. External mount actuators typically require a side plate or a sleeve to mount the actuator. Internal mounts actuators normally require that the damper has offset jack shafting. Internal Mount

To determine the proper actuator for a damper. Control Damper Training To determine the proper actuator for a damper. Refer to our catalog sheet entitled Louver and Air Control Dampers, in the Actuators and Accessories section. 1. Calculate the square footage of the damper; example, 48” w x 36” h = 12 square feet. 2. Choose type of actuator - example, 2-position, spring return, 120 volt, no internal switch package. 3. Top left section of our catalog sheet see section 2-Position Spring Return, and then see list of actuators under column entitled 120 VAC Model. 4. Determine if the damper has seals or not: • If yes, use the last column and any actuator rated 12 square feet or above (under 120 VAC) is acceptable i.e. FSNF-120 NF-120 AF-120

6. If the damper has no seals, use the 2nd last column and follow the Control Damper Training 5. From the list you would typically choose the most economical actuator. 6. If the damper has no seals, use the 2nd last column and follow the same steps to determine the list of actuators. Note: If the job site conditions are greater than 2,000 fpm and/or 1” wg, contact the factory so we can calculate the requirements and quote the proper actuator.

Other Options & Accessories Control Damper Training Other Options & Accessories Low Leakage Seals • Stainless steel jamb seal and PVC blade edge seal. Locking Quadrants • Allow the damper blade to be manually positioned and locked in place to supply the desired air volume. Flange Frame • For flush mounting to equipment/wall. 304 Stainless Steel Construction PI-50 Dual Position Indicator Switch • Provides damper “open” or “closed” signal for fan interlock. SQ-315 LQ-560

Control Damper Training Testing Commercial Control Dampers must function in the HVAC System so as to not adversely affect it. Dampers are tested in accordance with AMCA 500-D. Dampers are certified and labeled In accordance with AMCA 511.

AMCA 5.3 – Ducted Inlet & Outlet Control Damper Training Test Samples • Leakage: Max-Max, Min-Max, Max-Min. • Pressure Drop: 12x12, 12x48, 48x12, 24x24, 36x36. Leakage Rating Pressure Drop • Ducted Inlet & Outlet - AMCA 5.3 Lowest Pressure Drop • Ducted Inlet Only - AMCA 5.2 • Plenum Mount - AMCA 5.5 Highest Pressure Drop Maximum Allowed Leakage (cfm/ft2) Class @ 1 in.wg. @ 4 in.wg. 1A 3 8 1 4 8 2 10 20 3 40 80 AMCA 5.3 – Ducted Inlet & Outlet AMCA 5.2 Ducted Inlet AMCA 5.5 – Plenum Mount

Control Damper Training THANK YOU!