1 Steps to Healthier Homes n Start with People n House as a System n Keep It: DryClean Pest-Free Ventilated SafeContaminant-Free Maintained n Making it.

Slides:



Advertisements
Similar presentations
The Pollution Within: Sick Building Syndrome (SDS)
Advertisements

Air pollution and health
Heating, Ventilation, and Air-Conditioning (HVAC) Systems
PowerPoint ® Presentation Chapter 3 Contaminants Poor Indoor Air Quality Effects of Poor Indoor Air Quality Particles Asbestos Lead Gases Carbon Dioxide.
Carbon Monoxide in Your Home. What is Carbon Monoxide? CO Deadly gas Cant see, taste, feel or smell.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – July 2012eere.energy.gov Building Science Basics WEATHERIZATION INSTALLER/TECHNICAN FUNDAMENTALS.
Heating, Ventilating, and Air-Conditioning
Heating, Ventilating, and Air-Conditioning (HVAC)
ENERGY STAR Qualified Homes
Change in the way we build -Tighter -More chemicals -Air conditioning IAQ…Why is it a bigger issue than ever? Change in the way we live -90% of time indoors.
Mechanical Plan Review. Review Plan Package Use Group/Occupancy Correct Code Reference/Conformance Revisions Mechanical Plans/Spec Books Structural Plans.
INTD 51 human environments building systems. heating/ventilation/air-conditioning (HVAC) maintain a comfortable indoor climate control temperature and.
Environmental Health Issue- Carbon Monoxide Presented by QBE Loss Control Services.
Indoor Air Pollution.
DZAC January 2012 Opening Remarks Ken Fletcher. Items of Interest $25 Safety Spot Award Program to start this month Interpretation of safety signs 2.
Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.
Protecting Against Carbon Monoxide in Your Home
By Williston Fire Department. Importance Of Fire Safety Fire kills more Americans than all natural disasters combined. Annually 4,000 people will lose.
Healthy Homes Carbon Monoxide: The Silent Killer and other Combustion Gases 1 April 2014.
Station 3 ?? Air Meters Combustion Analyzer Carbon Monoxide Carbon Dioxide Particles Air Flow Vane Anemometer Exhaust Flow Box Pressures CAZ Test.
Air Quality Testing By: The Mean Green Team. Indoor Air Quality  A new science to measure pollutants  Houses  Schools  Buildings  Symptoms for poor.
Lesson 3 How does radon enter a home?. Slide 4-1 Predicted average indoor radon levels (U.S.) This map cannot be used to determine the radon level of.
Placing Vapor Distribution Systems and Appliances into Operation MODULE 5 Validating Combustion Air.
Energy Efficient Building Design & Indoor Air Quality.
HVACR416 - Design Pressure Measurement Part 2. Pressure Measurement Several pressure measurements exist. They all measure the same things, the force of.
I NDOOR A IR Q UALITY Presented by Team Winaught.
1 Steps to Healthier Homes n Keep It: Dry Clean Pest-Free Ventilated SafeContaminant-Free Maintained.
APES INDOOR AIR POLLUTION NOTES. INDOOR AIR POLLUTION The quality of indoor air can be two to five times (and even up to 100 times) more polluted.
INDOOR AIR POLLUTION Just because you can’t see it, doesn’t mean it isn’t there. When was the last time you dusted your house. What are its components?
Dry and Well Ventilated Housing Green and Healthy Strategies for Multi Family Properties Prepared with Assistance from: Tohn Environmental Strategies &
Keep it Dry and Ventilated 1. Steps to Healthier Homes 2 n Keep It: Dry Clean Pest-Free Ventilated SafeContaminant-Free Maintained.
Ontario Building Code Revision effective Jan 1, 2015
MORE THAN JUST STAYING WARM… BRANDY TOFT AIR QUALITY SPECIALIST LEECH LAKE BAND OF OJIBWE Home Heating.
HVACR311 – Electrical for Refrigeration International Mechanical Code Relating to Refrigeration.
Healthy Homes Overview Ventilation. Learning Outcomes Upon completion of this module you will be able to:  Identify the basic operating principle of.
Part 2: Buildings as a System Lee F. Ball Jr., PhD
Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ.
Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study In.
Building Codes and Interior Design
ASHRAE A Ventilation Standard for Residential Structures Ventilation and Acceptable Indoor Air Quality in Low- Rise Residential Buildings.
HAZARDS IN THE HOME. Environmental Hazard Radon Asbestos Lead Hazardous Waste Carbon Monoxide.
City of Marshalltown 2012 Employee Training - Safety.
Updated Space Heater Policy For Weatherization -- Draft National Weatherization Training Conference Orlando, FL December 10, 2007.
Air Conditioning International Mechanical Code
CHAPTER 17 Section 17-5; Indoor Air Pollution. OBJECTIVE:  Evaluate the types and effects of indoor air pollution.
Placing Vapor Distribution Systems and Appliances into Operation MODULE 10 Spillage Test.
Furnace Safety. AS WEATHER TURNS COLDER, BE AWARE OF AN INVISIBLE KILLER THAT CAN SEEP THROUGH THE HOME, CAUSING SERIOUS INJURY OR DEATH.
By the Indoor Air Pollution Awareness Team (IAPAT)
1 Mansel Nelson, ITEP–EEOP. 2 3 Safety Perform regular maintenance Avoid installing unvented (or "vent-free”) heating appliances Consider using only.
Section 3 Using Heat.
Healthy Homes Home Energy & Weatherization. Energy Management for Home goals … save energy provide comfort assure safety and health.
Air Pollution Pollution.  Pollutants entering the home  What we do in our homes and the products we use  How the home is built and maintained Factors.
Radon in the home For most Americans, greatest exposure to radon is in home, especially in rooms that are Below grade (such as basements) In contact with.
Integrated Science 11 CMH Ventilation CREATED BY: Reynaldo Thomas.
1 1 Weatherization & Indoor Air Quality Impacts of Weatherization on Air Quality and Comfort Inside Your Home Prepared with the assistance of Jed Harrison,
AP Environmental Science Indoor Air Pollution (Chapter 24)
3.0 Comprehensive Performance Audit Fossil Fuel Appliances Health & Safety 3.2.
Day 1 Part 4 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
SECTION 6 AIR CONDITIONING (HEATING AND HUMIDIFICATION) UNIT 34 INDOOR AIR QUALITY.
Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
1 College of agriculture BY : HONAR S. MAHDI DEPT. OF RECREATION AND ECOTOURISM.
Indoor Air Pollution.
Part 12 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Keep it ventilated Steps to Healthier Homes
Electrical Gas Plumbing Heating & Cooling
AP Environmental Science
______________ Combustion Engine
Building standards Mr. Da Silva.
Presentation transcript:

1 Steps to Healthier Homes n Start with People n House as a System n Keep It: DryClean Pest-Free Ventilated SafeContaminant-Free Maintained n Making it Work

Version Why Well Ventilated?  Pollutants can be found in concentrations 2-5 times higher indoors than outdoors.  Proper ventilation can reduce hazards of: — Volatile organic compounds — Moisture — Environmental tobacco smoke — Particulate matter — Allergens — Mold — Carbon monoxide — Formaldehyde

Version Type of Heating Fuel n Water Heater — 51% have piped gas — 40% have electricity n Clothes Dryer — 21% have piped gas — 77% have electricity From American Housing Survey – 2007

Version Primary Heating Equipment n 63% have warm air furnace n 12% have steam or hot water system n 12% have electric heat pump But... n 1.3 million homes (1.2%) have room heaters without flue n 900,000 homes (0.8%) rely on stoves n 120,000 homes (0.1%) rely on cooking stove For their Primary Source of Heat!

Version Heating Problems n 7% were uncomfortably cold for more than 24 hours — 11% for renters n 1% had inadequate heating capacity — 2% for renters and residents below poverty level n 0.8% had inadequate insulation — 1.6% for renters — 1.4% for residents below poverty level

Version Sources of Combustion Contaminants n Oven as heater n Spillage from furnace, water heater, fireplace n Ventless heater or fireplace n Car exhaust from attached garage

Version Combustion Contaminants? Health Effects  Carbon Monoxide — Fatigue, headaches, dizziness, confusion — The “Silent Killer”  Nitrogen Dioxide — Eye, nose, and throat irritation — Shortness of breath

Version Carbon Monoxide Limits AgencySituationMaximum CO Level Duration Environmental Protection Agency (EPA) Outdoor / Ambient Air 9 ppm8 hours 35 ppm1 hour Consumer Products Safety Commission / Underwriter Laboratories (UL) Alarms for Immediate Life Threats in Residential Air 70 ppm1 - 4 hrs 150 ppm min 400 ppm min Canadian Department of National Health and Welfare Air in Residences11 ppm8 hours 25 ppm1 hour World Health OrganizationIndoor Air32 ppmMax.

Version Carbon Monoxide Alarms  Consumer Product Safety Commission (CPSC) recommends: — Place near sleeping area — Put on every level of a home to provide extra protection — Do not install directly above or beside fuel-burning appliances

Version Smoke alarm, CO alarm, fire extinguishers?

Version Why Ventilated: Health Effects Approximately 500 carbon monoxide deaths plus more than 15,000 non-fire related healthcare visits per year.

Version Why Ventilated: Health Effects  Higher rates of respiratory irritation and illness in housing with poor ventilation — Common colds — Influenza — Pneumonia — Bronchitis … and increased rates of absence from school or work

Version Well-ventilated

Version A Well-Ventilated Building?

Version A Well-Ventilated Building Provides:  Local Exhaust Ventilation to remove moisture, odors, and other pollutants at the source  Whole House Ventilation for supplying fresh air to reduce contaminants by dilution  Control of airflow through building so crazy airflows can’t carry contaminants into and around the house

Version Key Concepts If any portion of air leaves a house the same amount must enter Air like water seeks the path of least resistance When heated air rises When cooled air falls Air can be hot, cold, wet, dry, or polluted when it enters or exits a house

Version What powers air flow? Wind Fans Temperature Differences

Version Air Flow in Homes  Typical homes do not have a planned supply of fresh air.  We depend on leakage such as windows, doors, and cracks.  This is usually not adequate.

Version Air Flow Needs Designed Holes Fresh air inlet/outlet Ventilation intake and exhaust Bath and kitchen exhaust vents Combustion vents Dryers Central vacuum outlet Chimneys

Version Multi-family dwellings should have planned fresh air supply because: –Neighbors are closer together –Stack effect- this dominates in cold weather

Version What are we looking for?  Bath, dryer, and range exhaust fans?  Gas stove used as heater?  Windows work?  Smoke alarm goes off?  Unvented gas or kerosene heaters?  Vented hot water heater?  Furnaces, boilers, fireplaces vented?  Rooms without windows?  Lingering odors?  Stale air?  Windows fog?

Version Things that need exhaust ventilation  Bathrooms  Clothes dryers  Kitchen ranges  Boilers, furnaces, hot water heaters  Fireplaces, wood burning stoves

Version Is there an exhaust in the bathroom? Does it work?

Version Testing Exhaust Fan: The Charmin Method

Version Ducted ok? Damper work?

Version

Version Local Ventilation: Kitchen  Remove moisture, odors, grease  If gas oven or range, remove products of combustion: moisture, CO, NO 2  Must be vented to the outside  If it is not reasonably quiet, many people will not use it.

Version

Version Multi-family exhaust only – new construction

Version

Version

Version Leaks in ducts:  Cause pressure imbalance  “Mine” contaminated air from garages, crawlspaces  Increase energy costs bad

Version Poorly sealed filter access panel

Version MERV Minimum Efficiency Rating Value (MERV) ASHRAE Standard 52.2 – Efficiency in collecting very small particles

Version MERVPARTICLE TYPICAL CONTROLLED SIZE (  m) CONTAMINANT 1 – 4 >10.0Pollen, sanding dust, textile and carpet fibers 5 – – 10.0Mold, spores, hair spray,cement dust 9 – – 3.0Legionella, lead dust, welding fumes 13 – – 1.0Bacteria, most tobacco smoke, insecticide dust, copier toner  0.3Virus, combustion particles, radon progeny MERV Ratings

Version MERV 8 v. 10

Version Other Rating Systems

Version And...

Version Code Requirements Related to Ventilation n Habitable spaces. — Every habitable space shall have at least one openable window. — The total openable area of the window in every room shall be equal to at least 45 percent of the minimum glazed area required in Section n Bathrooms and toilet rooms. — Every bathroom and toilet room shall comply with the ventilation requirements for habitable spaces as required by Section 403.1, except that a window shall not be required in such spaces equipped with a mechanical ventilation system. — Air exhausted by a mechanical ventilation system from a bathroom or toilet room shall discharge to the outdoors and shall not be recirculated.

Version Code Requirements Related to Ventilation n Exhaust vents. Pipes, ducts, conductors, fans or blowers shall not discharge gases, steam, vapor, hot air, grease, smoke, odors or other gaseous or particulate wastes directly upon abutting or adjacent public or private property or that of another tenant. n Process ventilation. Where injurious, toxic, irritating or noxious fumes, gases, dusts or mists are generated, a local exhaust ventilation system shall be provided to remove the contaminating agent at the source. Air shall be exhausted to the exterior and not be recirculated to any space. n Clothes dryer exhaust. Clothes dryer exhaust systems shall be independent of all other systems and shall be exhausted in accordance with the manufacturer’s instructions. n Removal of combustion products. All fuel-burning equipment and appliances shall be connected to an approved chimney or vent. — Exception: Fuel-burning equipment and appliances which are labeled for unvented operation.

Version Code Requirements Related to Ventilation n General. Duct systems shall be maintained free of obstructions and shall be capable of performing the required function. n Water heating facilities. — Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a temperature of not less than 110ºF (43ºC). — A gas-burning water heater shall not be located in any bathroom, toilet room, bedroom or other occupied room normally kept closed, unless adequate combustion air is provided. — An approved combination temperature and pressure-relief valve and relief valve discharge pipe shall be properly installed and maintained on water heaters. n Combustion air. A supply of air for complete combustion of the fuel and for ventilation of the space containing the fuel-burning equipment shall be provided for the fuel-burning equipment.

Version Key Messages  Ventilation plays an important role in maintaining health.  Ventilation is necessary to remove humidity and dilute or remove contaminants.  Local exhaust ventilation removes contaminants from a point source, while whole house ventilation uses fresh air to dilute contaminants.

Version Learning Objectives  Name five unhealthful conditions associated with poor ventilation.  List five things ( e.g. a room, appliance, mechanical system) in a household that need ventilation.  Name three things that power airflow in a building.  List three household contaminants that can be removed by ventilation.  Describe two ways ventilation reduces air contaminant levels.