CHE 185 – PROCESS CONTROL AND DYNAMICS CONTROL LOOP ANALYSIS.

Slides:



Advertisements
Similar presentations
CHE 185 – PROCESS CONTROL AND DYNAMICS
Advertisements

Model-based PID tuning methods Two degree of freedom controllers
Chapter 9 PID Tuning Methods.
13. Controller Tuning and Troubleshooting
Optimization-based PI/PID control for SOPDT process
CHE 185 – PROCESS CONTROL AND DYNAMICS
PID Controllers and PID tuning
Modern Control Systems (MCS)
1 ChE / MET Apr 12. Feedback Controller Tuning: (General Approaches) 1)Simple criteria; i.e QAD via ZN I, t r, etc easy, simple, do on existing.
Chapter 10 Stability Analysis and Controller Tuning
Chapter 4: Basic Properties of Feedback
Controller Design, Tuning. Must be stable. Provide good disturbance rejection---minimizing the effects of disturbance. Have good set-point tracking---Rapid,
Ratio Control Chapter 15.
Chapter 10 Control Loop Troubleshooting. Overall Course Objectives Develop the skills necessary to function as an industrial process control engineer.
A UTOMATING PID C ONTROLS IN M ATHCAD Neil Kuyvenhoven Engr 315 December 11,2002.
ChE / MET Mar Mar 07 2 Apr Mar 09.
CHE 185 – PROCESS CONTROL AND DYNAMICS
CHE 185 – PROCESS CONTROL AND DYNAMICS
Electric Drives FEEDBACK LINEARIZED CONTROL Vector control was invented to produce separate flux and torque control as it is implicitely possible.
CHE 185 – PROCESS CONTROL AND DYNAMICS
CHE 185 – PROCESS CONTROL AND DYNAMICS
CHE 185 – PROCESS CONTROL AND DYNAMICS PID CONTROL APPLIED TO MIMO PROCESSES.
CHE 185 – PROCESS CONTROL AND DYNAMICS
Controllers With Two Degrees of Freedom
Controller Tuning: A Motivational Example
Process Control Instrumentation II
LECTURE#11 PID CONTROL AUTOMATION & ROBOTICS
Lecture 7: PID Tuning.
بسم الله الرحمن الرحيم PID Controllers
Chapter 8 Performance of P-only, PI and PID Controllers.
Chapter 7 PID Control.
Cascade, Ratio, and Feedforward Control
PID Feedback Controllers PID 反馈控制器
Proportional/Integral/Derivative Control
Cascade and Ratio Control
DYNAMIC BEHAVIOR AND STABILITY OF CLOSED-LOOP CONTROL SYSTEMS
Simple rules for PID tuning Sigurd Skogestad NTNU, Trondheim, Norway.
CS 478: Microcontroller Systems University of Wisconsin-Eau Claire Dan Ernst Feedback Control.
Controller Design (to determine controller settings for P, PI or PID controllers) Based on Transient Response Criteria Chapter 12.
Model Reference Adaptive Control (MRAC). MRAS The Model-Reference Adaptive system (MRAS) was originally proposed to solve a problem in which the performance.
PID Controller Design and
Low Level Control. Control System Components The main components of a control system are The plant, or the process that is being controlled The controller,
Feedback Control system
Lecture 5: Basic Dynamical Systems CS 344R: Robotics Benjamin Kuipers.
بسم الله الرحمن الرحيم Advanced Control Lecture three Mohammad Ali Fanaei Dept. of Chemical Engineering Ferdowsi University of Mashhad Reference: C. C.
Chapter 7 Adjusting Controller Parameters Professor Shi-Shang Jang Chemical Engineering Department National Tsing-Hua University Hsin Chu, Taiwan.
PID CONTROLLERS By Harshal Inamdar.
SELF TUNING OF CONTROLLERS What is a Controller Controller is an active element or device that receives the information from the measurements and takes.
ERT 210/4 Process Control Hairul Nazirah bt Abdul Halim Office: CHAPTER 8 Feedback.
Lecture 25: Implementation Complicating factors Control design without a model Implementation of control algorithms ME 431, Lecture 25.
PID Feedback Controllers Lei XIE Department of Control, Zhejiang University, Hangzhou, China 2013/3/20.
Chapter 4 A First Analysis of Feedback Feedback Control A Feedback Control seeks to bring the measured quantity to its desired value or set-point (also.
ChE 182 Chemical Process Dynamics and Control
Process Control Methods 1. Open-Loop Control 2 Process control operations are performed automatically by either open-loop or closed-loop systems Processes.
Control Loops Tune a Fish. Control Loops Tuning of a control loop involves selecting loop parameters to ensure stable control under all operating conditions.
1 CBE 491 / Oct 12 Deadtime in a Process. 2 Dead Time in a Process Show how dead time might show up How it affects block diagrams How it affects.
1 PID Feedback Controllers PID 反馈控制器 Dai Lian-kui Shen Guo-jiang Institute of Industrial Control, Zhejiang University.
ABE425 Engineering Measurement Systems ABE425 Engineering Measurement Systems PID Control Dr. Tony E. Grift Dept. of Agricultural & Biological Engineering.
Process Control. Feedback control y sp = set point (target value) y = measured value The process information (y) is fed back to the controller The objective.
Chemical and Bio-Process Control
EEN-E1040 Measurement and Control of Energy Systems Control I: Control, processes, PID controllers and PID tuning Nov 3rd 2016 If not marked otherwise,
Table of Contents PART I: INTRODUCTION Chapter1: Introduction
Intrnal guide Asst. Prof. J.G.bhatt
Introduction to PID control
Tuning of PID controllers
Tuning of PID controllers
Process Control Engineering
بسم الله الرحمن الرحيم PID Controllers
PID Controller Design and
A Tutorial Overview Proportional Integral Derivative.
Presentation transcript:

CHE 185 – PROCESS CONTROL AND DYNAMICS CONTROL LOOP ANALYSIS

METHODS TO FIELD TUNE FAST-RESPONSE CONTROL LOOPS THESE SYSTEMS CAN BE TUNED TO PROPORTIONAL ONLY TO OBTAIN DATA TO OPTIMIZE THE VALUE FOR K c AT QAD (QUARTER AMPLITUDE DAMPING). THE INTEGRAL SETTINGS CAN THEN BE TUNED TO OPTIMIZE THE RESET CAPABILITY THERE WILL BE A BALANCE BETWEEN THE SPEED OF RESPONSE AND THE SPEED FOR RESET

METHODS TO FIELD TUNE SLOW-RESPONSE CONTROL LOOPS THE APPROACH IS TO MAKE SMALL CYCLICAL STEP CHANGES AND USE THE RESPONSES TO CHARACTERIZE THE PROCESS PARAMETERS –SEE AUTOTUNE VARIATION (ATV) METHOD RESULTS IN FIGURE –CHARACTERIZATION IS BASED ON THE RATIO OF MEASURED AND SETPOINT AMPLITUDES, THE ULTIMATE GAIN AND THE ULTIMATE PERIOD ASSOCIATED WITH THIS TEST IS THE TIME BETWEEN CYCLE PEAKS FOR PROPORTIONAL ONLY CONTROL

METHODS TO FIELD TUNE THE VALUES FROM THE TESTS ARE THEN USED WITH RECOMMENDED TUNING SCHEMES: –ZIEGLER-NICHOLS –TYREUS AND LUYBEN –FINE TUNING FROM THESE INITIAL VALUES MUST HAVE SIMULTANEOUS ADJUSTMENTS IN K c AND τ I, TYPICALLY USING A TUNING FACTOR F:

FIELD TUNING APPROACH TURN OFF INTEGRAL AND DERIVATIVE ACTION. MAKE INITIAL ESTIMATE OF K C BASED ON PROCESS KNOWLEDGE. USING SETPOINT CHANGES, INCREASE K C UNTIL TUNING CRITERION IS MET

FIELD TUNING APPROACH DECREASE K c BY 10%. MAKE INITIAL ESTIMATE OF τ I (I.E.,  τ I =5τ p ). REDUCE τ I UNTIL OFFSET IS ELIMINATED CHECK THAT PROPER AMOUNT Of K c AND τ I ARE USED.

EXAMPLE OF INADEQUATE INTEGRAL ACTION OSCILLATIONS NOT CENTERED ABOUT SETPOINT AND SLOW OFFSET REMOVAL INDICATE INADEQUATE INTEGRAL ACTION.

AUTOTUNE VARIATION ATV IDENTIFICATION AND ONLINE TUNING PERFORM ATV TEST AND DETERMINE ULTIMATE GAIN AND ULTIMATE PERIOD. SELECT TUNING METHOD (I.E., ZN OR TL SETTINGS). ADJUST TUNING FACTOR, F T, TO MEET TUNING CRITERION ONLINE USING SETPOINT CHANGES OR OBSERVING PROCESS PERFORMANCE: K C =K C ZN /F T τ I =τ  ZN ×F T

ATV TEST SELECT h SO THAT PROCESS IS NOT UNDULY UPSET BUT AN ACCURATE A RESULTS. CONTROLLER OUTPUT IS SWITCHED WHEN y s CROSSES y 0 IT USUALLY TAKE 3-4 CYCLES BEFORE STANDING IS ESTABLISHED AND a AND P u CAN BE MEASURED.

APPLYING THE ATV RESULTS CALCULATE K u FROM ATV RESULTS. ZN SETTINGS TL SETTINGS

COMPARISON OF ZN AND TL SETTINGS ZN SETTINGS ARE TOO AGGRESSIVE IN MANY CASES WHILE TL SETTINGS TEND TO BE TOO CONSERVATIVE. TL SETTINGS USE MUCH LESS INTEGRAL ACTION COMPARED TO THE PROPORTIONAL ACTION THAN ZN SETTINGS. AS A RESULT, IN CERTAIN CASES WHEN USING TL SETTINGS, ADDITIONAL INTEGRAL ACTION IS REQUIRED TO REMOVE OFFSET IN A TIMELY FASHION.

ADVANTAGES OF ATV IDENTIFICATION MUCH FASTER THAN OPEN LOOP TEST. AS A RESULT, IT IS LESS SUSCEPTIBLE TO DISTURBANCES DOES NOT UNDULY UPSET THE PROCESS.

ONLINE ATV TUNING EXAMPLE PROVIDES SIMPLE ONE-DIMENSIONAL TUNING WHICH CAN BE APPLIED USING SETPOINT CHANGES OR OBSERVING CONTROLLER PERFORMANCE OVER A PERIOD OF TIME.

ATV TEST APPLIED TO COMPOSITION MIXER

METHODS TO FIELD TUNE SOME TUNING METHODS HAVE BEEN DEVELOPED FOR SPECIFIC PROCESSES –LEVEL CONTROL - MARLIN RELATIONSHIPS FOR CRITICALLY DAMPED SYSTEMS - SEE EQUATIONS AND INTERFACE WITH DISTRIBUTED CONTROL SYSTEMS CONTROL INTERVAL IS THE SAMPLING TIME FOR A DCS – EQN NEEDS TO BE A FUNCTION OF THE PROCESS DEADTIME AND TIME CONSTANT

CONTROLLER RELIABILITY THE ABILITY OF A CONTROLLER TO REMAIN IN STABLE OPERATION WITH ACCEPTABLE PERFORMANCE IN THE FACE OF THE WORST DISTURBANCES THAT THE CONTROLLER IS EXPECTED TO HANDLE.

CONTROLLER RELIABILITY ANALYSIS OF THE CLOSED LOOP TRANSFER FUNCTION FOR A DISTURBANCE SHOWS THAT THE TYPE OF DYNAMIC RESPONSE (I.E., DECAY RATIO) IS UNAFFECTED BY THE MAGNITUDE TO THE DISTURBANCE.

CONTROLLER RELIABILITY NON-LINEAR EFFECTS – FIGURE FROM INDUSTRIAL EXPERIENCE WE KNOW THAT CERTAIN LARGE MAGNITUDE DISTURBANCE CAN CAUSE CONTROL LOOPS TO BECOME UNSTABLE. THE EXPLANATION OF THIS APPARENT CONTRADICTION IS THAT DISTURBANCES CAN CAUSE SIGNIFICANT CHANGES IN K p, τ p, AND θ p WHICH A LINEAR ANALYSIS DOES NOT CONSIDER.

CONTROLLER RELIABILITY EXAMPLE: CSTR WITH ΔC A0 UPSETS

CONTROLLER RELIABILITY IS DETERMINED BY THE COMBINATION OF THE FOLLOWING FACTORS –PROCESS NONLINEARITY –DISTURBANCE TYPE –DISTURBANCE MAGNITUDE AND DURATION IF PROCESS NONLINEARITY IS HIGH BUT DISTURBANCE MAGNITUDE IS LOW, RELIABILITY IS GOOD. IF DISTURBANCE MAGNITUDE IS HIGH BUT PROCESS NONLINEARITY IS LOW, RELIABILITY IS GOOD.

TUNING CRITERION SELECTION EXAMPLE WITH CHOICE BETWEEN FEED RATE OR RECEIVER LEVEL CONSIDER REACTOR RESIDENCE TIME

TUNING CRITERION SELECTION EXAMPLE WITH CHOICE BETWEEN FEED RATE OR RECEIVER LEVEL CONSIDER REACTOR RESIDENCE TIME

TUNING CRITERION SELECTION EXAMPLE WITH CHOICE BETWEEN REACTOR COMPOSITION AND SEPARATION

TUNING CRITERION SELECTION PROCEDURE FIRST, BASED ON OVERALL PROCESS OBJECTIVES, EVALUATE CONTROLLER PERFORMANCE FOR THE LOOP IN QUESTION. IF THE CONTROL LOOP SHOULD BE DETUNED BASED ON THE OVERALL PROCESS OBJECTIVES, THE TUNING CRITERION IS SET. IF THE CONTROL LOOP SHOULD BE TUNED AGGRESSIVELY BASED ON THE OVERALL PROCESS OBJECTIVES, THE TUNING CRITERION IS SELECTED BASED ON A COMPROMISE BETWEEN PERFORMANCE AND RELIABILITY.

TUNING SELECTION CRITERION IS A COMPROMISE BETWEEN PERFORMANCE AND RELIABILITY SELECT THE TUNING CRITERION (TYPICALLY FROM CRITICALLY DAMPED TO 1/6 DECAY RATIO) BASED ON THE PROCESS CHARACTERISTICS: –PROCESS NONLINEARITY –DISTURBANCE TYPES AND MAGNITUDES

Effect of Tuning Criterion on Control Performance THE MORE AGGRESSIVE THE CONTROL CRITERION, THE BETTER THE CONTROL PERFORMANCE, BUT THE MORE LIKELY THE CONTROLLER CAN GO UNSTABLE.

FILTERING THE SENSOR READING FOR MOST SENSOR READINGS, A FILTER TIME CONSTANT OF 3 TO 5 S IS MORE THAN ADEQUATE AND DOES NOT SLOW DOWN THE CLOSED-LOOP DYNAMICS. FOR A NOISY SENSOR, SENSOR FILTERING USUALLY SLOWS THE CLOSED-LOOP DYNAMICS. TO EVALUATE COMPARE THE FILTER TIME CONSTANT WITH THE TIME CONSTANTS FOR THE ACUTATOR, PROCESS AND SENSOR.

RECOMMENDED TUNING APPROACH SELECT THE TUNING CRITERION FOR THE CONTROL LOOP. APPLY FILTERING TO THE SENSOR READING DETERMINE IF THE CONTROL SYSTEM IS FAST OR SLOW RESPONDING. –FOR FAST RESPONDING, FIELD TUNE (TRAIL- AND-ERROR) –FOR SLOW RESPONDING, APPLY ATV-BASED TUNING