Transmission Electron Microscopy

Slides:



Advertisements
Similar presentations
Basic Electron Microscopy
Advertisements

P3 Revision. How do forces have a turning effect? The turning effect of a force is called the moment. Distance from force to pivot – perpendicular to.
Electron Optics Basic Introduction Bob Ashley
Introduction to Electron Microscopy
Lecture 11. Microscopy. Optical or light microscopy involves passing visible light transmitted through or reflected from the sample through a single or.
Electron Optics.
Do it with electrons ! II.
Scanning Electron Microscope (SEM)
Fire Protection Laboratory Methods Day
Groups: WA 2,4,5,7. History  The electron microscope was first invented by a team of German engineers headed by Max Knoll and physicist Ernst Ruska in.
Introduction Secondary electron secondary electron detector The electron beam interaction with near surface specimen atoms will make a signal which results.
Components of Initial Eprobe Startup Electron Gun –turning on beam, setting beam current, acceleration, saturation level Focusing lenses –Permit focussed.
X-radiation. X-rays are part of the electromagnetic spectrum. X-radiation (composed of X-rays) is a form of electromagnetic radiation. X- rays have a.
Electron Optics Two essential components: 1)Electron source (gun) 2)Focusing system (lenses) Add scanning apparatus for imaging Electron gun Cathode Anode.
How to explore a system? Photons Electrons Atoms Electrons Photons Atoms.
Electron Microscope. Light Resolution  The resolution of a microscope is limited by the diffraction of light. Single diffractionSingle diffraction 
CHAPTER 8 (Chapter 11 in text) Characterization of Nanomaterials.
Scanning Electron Microscope Jamie Goings. Theory Conventional microscopes use light and glass lenses SEM uses electrons and magnetic lenses to create.
The TEM system and components:
Instrumental Chemistry Chapter 12 Atomic X-Ray Spectroscopic.
Transmission Electron Microscopy (TEM) By Austin Avery.
Introduction to scanning electron microscopy
BY SANTANU PRAMANIK(09369) HITESH KUMAR GUPTA(09320) CHANDAN SINGH(09260) SCANNING ELECTRON MICROSCOPE MATERIAL SCIENCE ASSIGNMENT.
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
Electron Microscopy.
Electron Microscopy Jim Atherton. Development of Light Microscope 1590 Hans Zacharias Janssen 1660 Robert Hook o Onserved cells (cork) 1 Klein, Aaron.
Scanning Electron Microscopy
III. Analytical Aspects Summary Cheetham & Day, Chapters 2, 3 Chemical Characterization of Solid-State Materials Chemical Composition: Bulk, Surface, …
AP Physics Monday Homework W#3 Warm Up If a double slit experiment was done using a 450 nm laser, while shining through two slits of 1cm and projected.
Introduction to transmission electron microscopy
B. Spatial coherancy & source size Spetial coherancy is related to the size of the source. Source size governs spatial coherancy and maller source sizes.
Electron Microscopes Used to count individual atoms What can electron microscopes tell us? Morphology – Size and shape Topography – Surface features (roughness,
Scanning Electron Microscope (SEM)
X-Ray Diffraction Dr. T. Ramlochan March 2010.
Other modes associated with SEM: EBIC
Scanning Electron Microscope (SEM)
NANO 225 Micro/NanoFabrication Electron Microscopes 1.
Transmission Electron Microscope Basic premise of a TEM is to project a magnified image of the specimen onto a fluorescent screen where it can be viewed.
Reminders for this week Homework #4 Due Wednesday (5/20) Lithography Lab Due Thursday (5/21) Quiz #3 on Thursday (5/21) – In Classroom –Covers Lithography,
Medical Imaging Radiation I. Naked to the Bone: Medical Imaging in the Twentieth Century (Paperback)by Bettyann Kevles Bettyann Kevles E=mc2: A Biography.
Crystallography and Diffraction. Theory and Modern Methods of Analysis Lectures Electron Diffraction Dr. I. Abrahams Queen Mary University of London.
Nano-technology and Nano-electronics Department of Electrical and Computer Engineering, University of Tehran University of Tehran.
NANO 230 Micro/Nano Characterization
Characterization of Nanomaterials…
08/03/09 SEM signal generation
SEM Scanning Electron Microscope
Imaging Technology and Staining Techniques CHAPTER 1.3.
Transmission Electron Microscope
A.E. GunnæsMENA3100 V08 Electron Diffraction (ED) in the transmissions electron microscope.
Scanning Transmission Electron Microscope
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
Microscopy.
METHODOLOGY Nanotechnology Prof. Dr. Abdul Majid Department of Physics
Presentation on.  There are many methods for measuring of fiber structure. Such as:  The absorption of infrared radiation  Raman scattering of light.
SEM Imaging - Magnification and Deflection System
Scanning Electron Microscope Eee-Jay Rodriguez. The Structure of the Microscope Inside Outside.
Electron sources and guns
Introduction to scanning electron microscopy
Presentation on SEM (Scanning of Electron Microscope) Represented by:-Ravi Kumar Roll:- (BT/ME/1601/006)
Introduction to scanning electron microscopy
Laboratory equipment Lecture (3).
Introduction to Scanning Electron Microscope by Sameer S
METALLURGICAL MICROSCOPE
3.3 Other types of microscopy
NANO 230 Micro/NanoFabrication
TEM (Transition Electron Microscope)
Do it with electrons !.
SEM Imaging - Magnification and Deflection System
Chapter 16: Electron Diffraction
Presentation transcript:

Transmission Electron Microscopy David Stokes 2DX Workshop University of Washington 8/15-8/19/2011

Kinds of Electron Microscopes TEM transmissive resolution determined by optics analogous to bright field light microscope detector is film or CCD SEM reflective, surface imaging resolution determined by spot size x-ray microanalysis or EELS possible STEM transmissive, small spot with scan coils analogous to confocal detector is PMT  

SEM vs. TEM

TEM sectioned cell

TEM metal shadowed molecules 250 nm

TEM of frozen, isolated macromolecules Number of particles per micrograph and resolution needed determines magnification.

TEM of 2D membrane protein crystal

TEM images are 2D projections 3D Particle projected on 2D detector in TEM. Film, Phosphor screen or CCD.

Source of electrons Tungsten: - outer electrons of W are made free by heating the metal. - W has excellent yield when heated just below its melting temp of 3653K. - Heat to 2600K for good yield without melting and evaporating tip (saturation point) - 100 hrs with W wire. - Make filament (cathode) at neg potential (e.g. -100 kV). - As electrons boil off the W, they are repelled by the cathode. - Potential difference relative to the anode provides the accelerating voltage - Make Weihnolt several hundred volts more negative electrons pass through the aperture in the Weihnolt cap. bias controls output of electrons and shapes field - Anode is grounded so electrons are accelerated towards it. - Electrostatic field causes crossover at the anode - this is effective source size LaB6 - has lower work function: amount of energy necessary to free electrons. - 1000K with higher electron yield and longer life. - get small beam crossover size with high flux (10x emission of W) Field emission - single crystal of W oriented relative its xtal lattice - no heating - series of high voltage anodes draw electrons out of lattice - electrostatic lens of anodes -> 10 nm source size - need very high vacuum -> contamination - Zirconium to reduce work function, heating to reduce contamination

from Reimer

Properties of Electrons Energy of electrons is work W required to move electron from anode to cathode against force F=-eE: U=accelerating voltage charge on electron is -1.602x10-19 Coulombs, when accelerated through 1V potential difference has kinetic energy of 1.602x10-19 Nm (joule) define this kinetic energy as 1 eV. With accelerating voltage of 200kV – electrons have energy of 200keV (= 3.2x10-14 joules) compare to C-C bond of 5.8x10-19 joules (3.6 eV) or lattice binding energy of 1-2 eV Speed of electrons at 100kV: v=1.64x108m/sec  more than 1/2 speed of light Have to consider relativity 1MeV = 2Eo  m=3m0 Wavelengths of electrons () 0.0349 Å at 120kV, 0.025 Å at 200 kV, 0.01969 Å at 300 kV compare with wavelength of light: 2000 Å or X-rays: 1.5 Å for Cu K 1 Å synchrotron radiation diffraction limit for resolution of any optical system: D = /2

Force on an electron electrostatic: electromagnetic:

Typical electron lenses single lens (e.g. condensor) split lens (e.g. objective)

Magnetic lenses like Glass lenses are governed by Newton’s lens equation http://members.shaw.ca/quadibloc/science/opt05.htm and

Focal length of Electromagnetic lens f = focal length K = lens const, U = voltage, i = current electromagnetic lens: can change focal length by changing current glass lens: change focus by moving specimen up and down change magnification by switching lenses

Lens Strength affects focal length f = focal length K = lens const, U = voltage, i = current A stronger lens demagnifies the image!!!

Trajectory of electrons through a homogeneous B field where  is angle between v and B Energy of electron conserved – no change in |v| If force is  to v: electron moves in a circle If force is || to v, path unchanged. Generally, path is spiral, with v|| and v components So electrons passing through given point P will intersect again at point P' PP' = v||Tc = vTccos, where Tc is time to complete circle, which is independent of  P' P If many angles focused in same plane, get image formed For small angles of , cos ~1 and get image formed at P'. Larger angles of  reduces the distance to P' (cos = (1 - 2/2 + . . .) and thus gives rise to spherical aberration

Real lens is non-homogeneous field - so-called bell-shaped field Aberrations: astigmatism, coma, spherical, field curvature, distortion (pincushion/barrel) chromatic and Contrast Transfer Function

TEM lens configuration Condenser Lenses: Demagnifies source Define “spot size” Objective lens: Defines image focus Has fixed magnification (20-50x) Intermediate lens: Controls whether Image or diffraction pattern Is recorded Projector lenses: Controls image magnification or Diffraction “camera length”

Condenser lenses C1 lens produces image of source C2 lens demagnifies onto sample C2 aperture reduces beam current and makes beam more parallel

C1 lens controls spot size Strong C1 lens produces small probe size and weak beam Weak C1 lens produces larger probe size and bright beam This is known as “spot size” C1 crossover produces image of source and Mag = u/v for C2 lens

Beam convergence Increasing strength of C2 lens ~parallel convergent Upper Objective lens ~parallel convergent divergent parallel

magnification of objective: 20-50x angle for 2.5 Å resolution at 200kv:  = /d = 0.025/2.5 = 10 mrad = 0.5° most of mag range achieved with projection lenses Much smaller angles and aberrations therefore less important

Diffraction vs. Imaging controlled by Intermediate lens Back focal plane of objective lens corresponds to diff pattern Selected area aperture is at first image plane Intermediate lens selects either BFP or 1st image plane as its object Diff pattern or 2nd image serves as object for projector lens

Coma For high resolution images, you want the apparent source aligned with the real source on the optical axis and the beam to run parallel to this axis. This is coma-free alignment.

Deflectors electrostatic electromagnetic Deflectors produced by transverse fields: E field (parallel plate capacitor) B field (electromagnetic lens) electrostatic electromagnetic

deflector coils generally come in pairs gun tilt coils pivot points aligned pivot points misaligned

Apertures source condensor lens condensor aperture specimen

A typical scattering event Proportionality constant for scattering: is scattering cross-section for one atom (cm2/atom) elastic, inelastic, absorption, fission

Electron Scattering Elastic Scattering: Rutherford scattering + + + + +   R z b F F electrostatic force: Z = atomic number, but, actually need to consider screening of electrons on nuclear charge Solving Scrodinger’s equation for the potential and making approximations for screening of nuclear charge by electron cloud: N.B. Elastically scattered electrons have same wavelength as incident beam and are most effective for generating phase contrast image because they interfere with the unscattered beam

Inelastic Scattering Energy transferred from incident electrons to the specimen Oscillations of molecular bonds and phonon excitations: 20 meV – 1 eV too small to generally observe given ~1 eV spread of beam energy Excitation of outer electrons and valence/conduction band electrons (metals): 1-50 eV 3. Ionization of inner electrons (K,L,M shells) to unoccupied shells: 10 – 100s eV

Why do we hate inelastic collisions? Inelastic electrons are focused at “undesirable” places And therefore produce a blurred image due to Chromatic aberration Inelastic scattering produces chemical changes radiation damage

differential cross-section total scattering cross-section scattered outside 2.4 A aperture unscattered inelastics within aperture differential scattering vs.  25 keV electrons with Ar gas elastics within aperture

The inelastic scattering “blurs” the low spatial frequencies electrons X-rays

But they can be filtered out (after they damaged the specimen)