5 Small Saver Cooking Measures Fryers, Holding Cabinets, Convection Ovens, Combination Ovens, Steamers Regional Technical Forum July 16, 2013.

Slides:



Advertisements
Similar presentations
T12 Replacements with HPT8s in Kitchens and Garages Regional Technical Forum October 15, 2013.
Advertisements

Estimating Key Parameters for the Retail Plug-Load Portfolio (RPP) Program: Recommended Methodological Approaches EM&V, Residential Programs, Products.
Planning for Updates and Linkages to EM&V CALMAC February 17, 2004.
Residential Refrigerators and Freezers UES Measure Update Regional Technical Forum October 14, 2014.
Residential Single Family Clothes Washer UES Measure Update Christian Douglass Regional Technical Forum February 18, 2015.
Commercial Clothes Washer UES Measure Update Regional Technical Forum February 19, 2014.
Transformer De-Energizing & Dairy Plate Heat Exchanger Standard Protocol Proposal Presentation to the RTF February 20, 2013.
Residential LED UES Measure Update Regional Technical Forum August 20, 2013.
Residential Refrigerators and Freezers UES Measure Update Regional Technical Forum October 14, 2014.
The Saga Continues: Measure Interactions for Residential HVAC and Wx measures Regional Technical Forum April 23, 2014.
Oregon Energy Star Homes Measure Update New Measure Proposal April 22nd,
Variable Frequency Drives (VFDs) for Potato/Onion Shed Fans UES Measure Update Regional Technical Forum April 23, 2014.
Residential Clothes Washers and Dryers Technical Subcommittee Ryan Firestone & Christian Douglass Regional Technical Forum March 10, PM.
Commercial Tank Water Heaters Out-of-Compliance (OOC) UES Measure Recommendation Regional Technical Forum November 19, 2013.
Grocery Measure: LEDs for Reach-In Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
Dairy Milking Machine Vacuum Pump VFD Savings Calculator Follow-up from the last RTF meeting with more field data Regional Technical Forum December 7,
Commercial Showerhead UES Measure Update Regional Technical Forum Staff Update June 18, 2013.
Night Covers on Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
Advanced Power Strips (APS) Planning UES Measure Proposal Regional Technical Forum August 20, 2013.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Commercial Kitchen Cooking Measures Convection Ovens, Combination Ovens, Dishwashers.
Pump VFD Provisional Standard Protocol Regional Technical Forum June 18, 2013.
Plans to bring Out-of-Compliance UES Measures back into Compliance: 1. Agricultural Irrigation Hardware UES 2. Agricultural Motors UES Regional Technical.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential Appliance Measure Updates Danielle Gidding Bonneville Power Administration.
Non-Residential Network Computer Power Management UES Measure Update Regional Technical Forum July 16, 2013.
Pre-Rinse Spray Valve Small Saver UES Measures Regional Technical Forum September 17, 2013.
Northwest Power and Conservation Council Slide 1 Direct Use of Natural Gas Economic Fuel Choices from the Regional Power System and Consumer’s Perspective.
Out-Of-Compliance Grocery UES Measure Recommendations Regional Technical Forum March 18, 2014.
Commercial Showerhead UES Measure Update Regional Technical Forum Staff Update June 18, 2013.
Delivery Verification Jennifer Anziano Regional Technical Forum March 17, 2015.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum June 16 th, 2015 Mohit Singh-Chhabra.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential Appliance Measure Updates Danielle Gidding Bonneville Power Administration.
Heat Pump Water Heater Request for Feedback on a proposal to add UES measures with a “Retail – any installation location” delivery mechanism Regional Technical.
Refrigerator Decommissioning: Measure Status Update Regional Technical Forum October 16, 2013.
SEEM Calibration: Phase-2 Adjustments for Failed VBDD Fits Regional Technical Forum August 12, 2014.
Anti-Sweat Heater Control Small Saver UES Measure Regional Technical Forum September 17, 2013.
Deemed Savings Update: ECMs in Display Cases Ben Cartwright PECI January 5, 2009.
Update: Grocery Refrigeration Provisional Standard Protocol for Site Specific Savings RTF Meeting June 28,
N ETWORK PC P OWER M ANAGEMENT June 28, 2011 Regional Technical Forum Presented by: Bob Tingleff SBW Consulting, Inc.
Hot Food Holding Cabinets, Steamers, and Fryers RTF Meeting 5/5/2009.
EER Analysis Results Regional Technical Forum March 18, 2014.
Commercial Showerhead UES Measure Update Regional Technical Forum April 16, 2013.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Energy Savings from Electric Water Heaters in Commercial Applications Danielle Gidding.
Integration Issues for RTF Guidelines: Savings, Lifetimes and Cost/Benefit October 24, 2012 Regional Technical Forum Presented by: Michael Baker, SBW.
Staff Updates Regional Technical Forum March 20, 2013.
Variable Speed Heat Pumps Provisional UES Proposal Presentation to the Regional Technical Forum September 18, 2012 Presentation by Kacie Bedney, Bonneville.
Beyond NEMA Premium Using CEE Motors List 1. Savings Summary Worksheet 2.
Commercial Ice-Makers May 27, 2008 RTF Meeting Calculator Update.
Residential New SF Energy Star Homes UES Measure Update December 17th, 2013.
T12 to HPT8 Change-outs Small/Rural request for development May 15, 2012.
PTCS Commissioning, Controls & Sizing Update of UES Measure Category and/or Status Regional Technical Forum July 15, 2014.
Out-Of-Compliance Grocery UES Measure Recommendations Regional Technical Forum July 15, 2014.
Hot Food Holding Cabinets, Steamers, and Fryers RTF Meeting 2/3/2009.
Display Case Motion Sensors Small Saver Measure Update July 16th, 2013.
Commercial Clothes Washer UES Measure Update Regional Technical Forum April 16, 2013.
Residential Showerheads UES Update Ryan Firestone Regional Technical Forum October 20, 2015.
RTF Delivery Verification Guidance Batch 2 Jennifer Anziano Regional Technical Forum September 22, 2015.
Residential Refrigerator UES Measure Update Regional Technical Forum April 16, 2013.
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
How The Regional Technical Forum Supports PNW Energy Efficiency Programs January 5, 2010.
ENERGY STAR Commercial Refrigerators and Freezers Regional Technical Forum January 21 st, 2016 Mohit Singh-Chhabra.
Non-Residential Network Computer Power Management Christian Douglass Regional Technical Forum January 21, 2016.
Agriculture Irrigation Hardware UES Measure Update Regional Technical Forum April 16, 2013.
Residential Single Family Clothes Washer UES Measure Update Regional Technical Forum September 16, 2014.
Exterior LED Area Lights
Commercial Efficient Tank Water Heater UES Measure Update Regional Technical Forum December 17, 2013.
Commercial Refrigerators and Freezers Cost & Cost-Effectiveness RTF Meeting March 2nd, 2010 (continued from Feb 2 nd, 2010 meeting, with more Cost discussion.
Residential Behavior-based Programs Measure Development Update Ryan Firestone Regional Technical Forum March 15, 2016.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum June 17, 2014.
Single Family New Construction Measure: Slab Insulation Mohit Singh-Chhabra Regional Technical Forum April 19 th, 2016.
Presentation transcript:

5 Small Saver Cooking Measures Fryers, Holding Cabinets, Convection Ovens, Combination Ovens, Steamers Regional Technical Forum July 16, 2013

Cooking Measure Overview Current Category: Small Saver Current Status: Under Review Current Sunset Date: July, 2013 Reason for Update/Review: Follow-up to recommendation memo Subcommittee Review: Yes (volunteer panel) 2

Foodservice measure history 5 cooking measures recommended to Small Saver category during 2012/2013 review Many common parameters among measures – Recommendation memos suggest convening expert panel to discuss several parameters Met with foodservice volunteers on 7/1/13 Arrived at agreement among many common parameters and measure savings approach – Several decisions suggested for full RTF discussion

Subcommittee Volunteer List Rick Knori (Lower Valley Energy) Jeff Mitchell (PECI) Tianna Byrtus (PSE) - Provided program data Nick O’Neil (NPCC) Received program info from Ted Light (ETO) Talked with David Zabrowski at FSTC after subcommittee meeting

Parameters common to all measures Efficient Case Market Penetration Rate Annual Hours of Operation Baseline and Efficient Case Sources Preheat Energy Lbs of Food cooked per day Lbs/day Utilization Factor

Efficient Case Market Penetration Rate Agreed to use ENERGY STAR shipment data to establish penetration rates – Published in 2011, and refreshed annually – Use unless spec has recently taken place, skewing shipments In those cases, use CEC database (if available) or entire market as proxy for market penetration rate This occurs with HFHC where new spec has taken place and CEC database data provides a proxy for market

Annual Hours of Operation FSTC & DEER say 15 hours/day, 365 days/year – Likely to be different for each building type 2009 CBSA shows varying hours by building type – Restaurant: 93 hours/week – Hotel/Motel: 160 hours /week – School: 52 hours/week – Dry Goods Retail: 73 hours/week Agreed store HOU ≠ equipment HOU – i.e. We need a utilization factor FSTC uses a set lbs food cooked /day to arrive at utilization average across building use types Previous method used max cooking rate and developed “part-load” usage of equipment per day

HOU Reports & Methodology 1993 Arthur D. Little (ADL) report provides estimates of cooking equipment distribution by building type (referenced by FSTC 2002 tech assessment) 2009 CBSA provides a representative sample of PNW building operating hours FSTC methodology incorporates a “utilization factor” by determining average lbs/day of food cooked on equipment compared to theoretical maximum – Doing so allows for separation of idle and cooking energy – Still uses average of 15hrs/day and 365 days/yr for calculations

HOU Reports & Methodology Agreed that approach would be: – Use ADL distribution of equipment locations* Ex. % split of equipment found in schools vs. restaurants – Use CBSA data to obtain daily HOU Ex. Average HOU/week for grocery vs. hospital – Use professional judgment to estimate annual days of operation for each business type Ex. Schools days/yr; Hospitals days/yr – Weight annual HOU estimates by equipment distribution to find overall average HOU for each piece of equipment *No ADL data available for HFHCs. Used PSE program data as proxy for likely install locations

2009 CBSA Data Distribution from ADLPSEAnalysis Facility Type HOU/Weekn% of totalFryersOvensSteamersHFHC* Days/Week HOU/Day Days/Year** HOU/Year Office %3%6%5%2% Dry Goods Retail %20%12%17%0% Restaurants931279%50%30%43%24% Grocery %6%7%0%2% Schools %9%21%15%72% Hotel/Motel160665%10%18% 0% Hospital122584%2%6%3%0% Weighted average *Not in ADL report so used weighted average of PSE install locations with ADL hours of use estimates **Offices: 249 workdays are used per year. Assume 52 weeks/yr x 5 days/week minus 12 holidays. Schools: 180 days per year typical for schools HOU Results HOU using CBSA Hours and ADL distribution Cooking Equipment Average HOU/Year HOU/WeekWeeks/YearDays/WeekHOU/DayDays/Year Fryers4, Ovens4, Steamer4, HFHC*2, *No data for HFHC in ADL study so PSE program data used to determine install location mix

Baseline and Efficient Case Sources Most parameters rely on testing done by FSTC – FSTC uses “representative sample” of economy grade and efficient grade units tested in the lab Not comprehensive but end-use monitoring confirms energy use – Some measures have different sources available CEC Database, FSTC dataset, ENERGY STAR QPL FSTC also tests and develops measures outside ENERGY STAR spec – Ex. 2/3 size combi-oven analyzed by FSTC however excluded by ENERGY STAR Agreed to use FSTC dataset for baseline case, and ENERGY STAR and CEE tiers (if developed) for efficient case

Preheat Energy Used in all measures FSTC provides estimate of energy, time and number per day Makes up less than 15% of overall unit energy consumption for an 8-hour/day operation – Savings impact is even less between baseline and efficient case: ~1-3% Agreed to adopt FSTC estimates of preheat energy, time and number per day

Lbs of Food Cooked Per Day Most FSTC measures use this parameter as a proxy for utilization – Given as lbs of food cooked per day compared to full load lbs/hr capability of equipment Typically equivalent to around a 15% utilization rate FSTC estimates values based on average makeup of building types* – Previously thought this was based on full-service restaurants only Agreed to use FSTC estimated values of lbs/day *Conversation with Dave Zabrowski at FSTC on 7/10/13

Remaining Issues for RTF Discussion EUL is not currently supported by data – DEER and FSTC assume 12 years Consistent with previous RTF analysis (likely citing DEER as a reference) – 2004 SERA retention study* (cited in DEER) indicates high removal/failure rate Likelihood analysis showed an EUL estimate of 5.6 years for ovens and 6.9 years for fryers. – 5.6 years for both if you include failed businesses – Other equipment studied had low sample sizes *ftp://ftp.cpuc.ca.gov/PUC/energy/electric/energy+efficiency/Rulemaking/cpucretentionrptsera102004_v20.pdf

SERA Retention Study

Retention Study Drawbacks Study doesn’t specify location in samples – Equipment more likely to fail in high use areas Unsure of what was replaced – Doesn’t mention if replaced efficiency was same or better, just that equipment did not match rebate Potential unknown equipment issues in 2004 – Was ENERGY STAR performance in 2004 as reliable as the market baseline equipment?

Potential EUL Path Assume restaurant kitchens have shortest life – Used 5.6 years in analysis, yielding 27,175 total equipment hours (cooking and idle) Ratio EUL of other business sectors to restaurant equipment hours Weight EUL for each sector by ADL distribution, consistent with savings methodology *EUL Limited to maximum of 25 years Analysis Facility Type Days/Week HOU/Day Days/Year** HOU/Year Equip Hours EUL Office ,93744,90115 Dry Goods Retail ,80934,6209 Restaurants ,85327,1756 Grocery ,89622,3654 Schools ,87270,44225* Hotel/Motel ,34915,7952 Hospital ,36620,7153 Weighted average ,91539,57612 Cooking Equipment Average HOU/Year HOU/DayDays/YearEUL Fryers Ovens Steamer HFHC*

Savings Comparison *Current proposal removes ¾ size HFHC and adds 4-pan & 10-pan steamer, and large-size Combi oven

Cost Comparison

TRC Comparison *High TRC capped at 11.0 to maintain chart scale

Decision “I _______ move to approve the updates to the 5 UES Cooking measures (HFHC, Steamers, Fryers, Combination Ovens & Convection Ovens); set the measure status to “Active”; and change the sunset date to July 2018 or until ENERGY STAR specifications are updated, whichever is sooner.”

BACK-UP SLIDES Subcommittee Decisions for Reference

Summary of UES Specific Issues HFHC – No market penetration data available Use splits in CEC database as market proxy Convection Oven – Two specs available to use for efficient case – Develop savings for ENERGY STAR v2.0 spec only which goes into effect 1/1/14 Difference between current v1.1 and proposed v2.0 is minimal (71% efficiency requirement compared to 70%) Only 1 model drops out of FSTC savings analysis

Summary of UES Specific Issues Combination Ovens – No data on combination mode use in field – FSTC assumes 50% in steam mode, 50% in oven mode – Recommend using FSTC assumptions since no field data exists Consistent with our “we know it’s something, but we don’t know exactly what it is” methodology – FSTC test data do not align with ENERGY STAR criteria Ex. FSTC tests efficient units and finds 73% average efficiency; ENERGY STAR requires minimum 75% efficiency Reason is because ENERGY STAR developed after FSTC workpapers Use ENERGY STAR data in FSTC savings methodology where lacking – No ENERGY STAR shipment data available since spec is new Program history implies very little uptake of measure Agreed to set market penetration rate at zero

Summary of UES Specific Issues Steamers – ENERGY STAR allows boilerless and boiler based systems to qualify; large difference in water consumption 92% are boilerless on current QPL Agreed to keep applicability open and not weighting for presence of boiler-based systems – Current approach is to use average savings regardless of pan count Clear cost difference between pan capacity Agreed to split up by pan capacity using incremental cost of each pan – Percentage of time in constant steam mode has little supporting field data information 90% for baseline, 0% for efficient case Recommend keeping estimate based on conversations with FSTC over baseline equipment operating in nearly constant steam mode