Radionuclide Generators

Slides:



Advertisements
Similar presentations
Nuclear Medicine Department Loyola University Medical Center
Advertisements

BACK TITRATION NUR SYAKINA BINTI ISHAK NUR RAIHAN BINTI MOHD AZMI
Instruments & Radiopharmaceutical Production
Isotopes. APPLICATIONS of nuclear processes Military Power Radiation Many important economic and social benefits are derived from the use of isotopes.
Hot Lab 2 Problem Solving
Ophthalmic products definition requirements types of additives
Equilibrium and Generators
Technetium-99m generator
Flame photometry.
Radiation Physics PHY471 A.M. El-Khayatt A. M. El-Khayatt, PHY464 Autumn 2014 Radiological physics is the science of ionizing radiation and its interaction.
Paper and Thin layer Chromatography
NUCLEAR CHEMISTRY DO NOW: Answer the following questions
Chromatography.
Radionuclide generators for Nuclear Medicine
Radiopharmaceutics.
Artificial WHY?? Revision What’s a radionuclide?
Lesson 14 Radiotracers. Introduction Basic principle: All isotopes of a given element will behave identically in most physical, environmental and biological.
Radiopharmaceutics.
Titremetric analysis Dr. Mohammad Khanfar. Concept of Titremetric analysis In general, we utilize certain property of a substance to be analyzed in order.
Radionuclide Generators
Rapid Separation Methods for Bioassay Samples S. L. Maxwell, III and D. J. Fauth Westinghouse Savannah River Site.
Quality Control of Radiopharmaceuticals
Radionuclide Production
Generators Dr. Dalia Ahmed MD Asst. Prof. Of Nuclear Medicine NMT 474.
Technetium-99m generator
Determination of bicarbonate in blood
Quality Control of Radiopharmaceuticals
Instruments for Radiation Detection and Measurement Lab # 3 (1)
(Enzyme Linked Immunosorbent Assay)
DNA Extraction And Purification BY Dr. Naglaa Fathy Lecturer of Biochemistry and Molecular Biology, faculty of medicine, Benha university Benha university2008.
Introduction to Nuclear Medicine
9. DIAGNOSTIC NUCLEAR MEDICINE
Copyright All images in this presentation are the property of Jane Hanrahan unless otherwise referenced.
RADIONUCLIDE GENERATORS
4. Electron capture:  This is an alternative to β + decay, when the nucleus has a smaller N/Z ratio compared to the stable nucleus (neutron deficient.
Tiahja Coston.  Atoms are a major part in any object that exists in our world. Seeing as atoms make up that important thing we call matter, we would.
L Molecular imaging is a new discipline that helps understanding complex pathological processes by visualizing unique molecular signatures at the cellular,
Introduction to Analytical Chemistry
QUALITY ASSURANCE Quality Assurance of Reagents, Supplies, And Laboratory Water.
Hot Lab 11. dose calibrator, an ionization chamber used in nuclear medicine to measure the amount of radioactivity of a radionuclide before injection.
Chapter 32 Radiochemical Methods. Introduction… Radiochemical methods tend to be labor intensive and generate liquid waste due to the chemical separations.
Section 8.4 – pg  Experimental designs discussed so far have been QUALitative (flame test, solution colour, litmus test, conductivity, solubility)
Nuclear Medicine 4103 Section I Basic Chemistry. Structure of The Atom Nucleus: contains Protons (+) and Neutrons (0) Electron (-) orbiting the nucleus.
1 Steps in a Gravimetric Analysis After appropriate dissolution of the sample, the following steps should be followed for a successful gravimetric procedure:
Day SOLVE: 1.5e24 molecules of SO 2 = ____ grams of SO 2 ? S 2 + 2O 2  2SO 2 And how many moles of S 2 ?
Radioactivity Manos Papadopoulos Nuclear Medicine Department
Radiopharmaceuticals and Kit preparation
2 Word Equations. Phase Symbols Are subscripts that indicate the phase of the chemical.
Radionuclides production cont. Generators. ● Where clinical tests require that a radioisotope be administered internally, it is advantageous to use an.
RADIOISOTOPE PRODUCTION NANIK DWI NURHAYATI,S.SI,M.SI.
Mrs: Aya Ahmed Abd alrahium saeed MSC &BSC Nuclear medicine
1 Chapter 2 Steps in a chemical analysis Plan of analysis Before doing any quantitative analysis, the following questions should be answered: 1-
Nuclear medicine Basic principles.
Activity 38 Follow-up: Based on your observation in Activities 37 & 38, what do you think determines how much of a substance dissolves? The identity of.
2/17/2016 L3-L4 1 PRINCE SATTAM BIN ABDUL AZIZ UNIVERSITY COLLEGE OF PHARMACY Nuclear Pharmacy (PHT 433 ) Dr. Shahid Jamil.
PRODUCTION OF RADIONUCLIDE PRODUCTION OF RADIONUCLIDE 2/27/2016 L5,L6 and L7 1 PRINCE SATTAM BIN ABDUL AZIZ UNIVERSITY COLLEGE OF PHARMACY Nuclear Pharmacy.
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
Technetium-99m By Emily Vella Science Assessment Task 3.
Chapter 1: The Nature of Analytical Chemistry
Recent Trends in Radioisotope Production by Using Cyclotron
Water.  Naturally occurring water exerts its solvent effect on most substances it contacts. So its impure, containing varying amounts of dissolved inorganic.
Analytical biochemistry laboratory (BIOC 343) L. Nouf Aalshareef KAU- Biochemistry department Second semester 2013.
Fundamentals of Analytical Chemistry Eighth Edition.
Experiment two The identification and the assay of Ammonium Chloride
Radionuclide Generators
Nuclear Medicine Physics
Radionuclides production cont.
Medical Dosage Calculations A Dimensional Analysis Approach
9. DIAGNOSTIC NUCLEAR MEDICINE
9. DIAGNOSTIC NUCLEAR MEDICINE
Presentation transcript:

Radionuclide Generators Lab 8

Generators Properties: A radionuclide generator must be sterile and pyrogen-free. The generator system may be sterilized either by autoclaving the entire column Or by preparing it from sterile materials under aseptic conditions. To maintain sterility Bacteriostatic agents are added to the generator column. Or a membrane filter unit is attached to the end of the column.

An ideal radionuclide generator should be: Simple Convenient Rapid to use Give a high yield of the daughter nuclide repeatedly and reproducibly Properly shielded to minimize radiation exposure Eluate should be free from the parent radionuclide and the adsorbent material Other extraneous radioactive contaminants should be absent in the eluate.Convenient The daughter nuclide should decay to a stable or very long-lived nuclide so that the radiation dose to the patient is minimal

Important Radionuclide Generators 99Mo–99mTc Generator 99Mo radionuclide B‾emission 87% metastable state 99mTc 13% ground state 99Tc 99mTc has a half-life of 6 hr and decays to 99Tc by isomeric transition Ground state 99Tc has a half-life of 2.1X105 years and decays to stable 99Ru by B‾ emission

Construction Liquid Column Generator Solid Column Generator

Construction Liquid Column Generator 20% NaOH solution of 99Mo in a glass column 99mTc radioactivity extraction with methyl ethyl ketone (MEK) Organic phase will be evaporated and the 99mTcO4‾ dissolved in isotonic saline for clinical use.

Construction Liquid Column Generator Advantage The cost of 99mTc is low. Disadvantage Needs a lot of manipulation in the overall method. It is rarely used in nuclear medicine.

Construction Solid Column Generator The 99Mo–99mTc or ‘‘Moly’’ generator is constructed with alumina (Al2O3) loaded in a plastic or glass column. The 99Mo radioactivity is adsorbed on alumina in the chemical form MoO24‾ (molybdate). The 99mTc radionuclide is eluted as sodium pertechnetate (Na99mTcO4) with a 0.9% NaCl solution.

Construction Solid Column Generator Shielding The generator columns are shielded with lead for radiation protection. Some commercial firms use depleted uranium in lieu of lead for shielding high 99Mo activity because 238U has higher Z and therefore attenuates g rays more efficiently Depleted uranium is natural uranium from which 235U has been removed, leaving only 238U).

Construction Solid Column Generator Yield of 99mTc One can calculate the theoretical yield of 99mTc from a Moly generator at a given time by using this Eq. For practical reasons, it is not possible to obtain a complete yield of 99mTc from a generator as predicted by this Eq.

Construction Solid Column Generator Yield of 99mTc One can calculate the theoretical yield of 99mTc from a Moly generator at a given time by using this Eq. For practical reasons, it is not possible to obtain a complete yield of 99mTc from a generator as predicted by this Eq.

Construction Solid Column Generator Why? The yield may be reduced by Yield of 99mTc For practical reasons, it is not possible to obtain a complete yield of 99mTc from a generator as predicted by this Eq. Why? The yield may be reduced by Column defect such as channeling in the adsorbent bed or by autoradiolysis due to high radioactivity whereby the chemical form of 99mTc changes.

Construction Solid Column Generator Problem Yield of 99mTc Problem A 2.6-Ci (96.2-GBq) Moly generator calibrated for Wednesday noon was received on Tuesday before. What would be the total 99mTc activity eluted at 8:00 a.m. on Friday?

Quality Control of 99mTc-Eluate Since 99mTc activity is used for humans, several quality control tests of the 99mTc-eluate are mandatory. 99Mo Breakthrough Aluminum Breakthrough pH Radiochemical Purity

99Mo Breakthrough Originates from the small quantity of 99Mo that may be eluted with 99mTc. The US Pharmacopeia limit is 0.15 mCi 99Mo/mCi 99mTc per administered dosage at the time of administration. The 99Mo contamination is measured by detecting 740-keV and 780-keV photons of 99Mo in a dose calibrator or a NaI(Tl) detector coupled to a pulse height analyzer.

Aluminum Breakthrough Originates from the alumina bed of the generator. The presence of aluminum in the 99mTc-eluate interferes with the preparation of 99mTc-sulfur colloid; particularly phosphate buffer in colloid preparations tends to precipitate with excessive aluminum. The USP limit is 10 µg Al/ml 99mTc for fission-produced 99Mo. Detected by the colorimetric method using aurin tricarboxylic acid or methyl orange, and can be quantitated by comparison with a standard solution of aluminum. Excessive amounts of aluminum in the eluate indicate lack of stability of the column.

pH The pH of the eluate should be between 4.5 and 7.5. Can be checked quantitatively with a pH meter or qualitatively with pH paper.

Radiochemical Purity The impurities of the 99mTc eluate are different chemical forms of radioactivity other than 99mTcO-4 These impurities should be checked by suitable analytical methods.

Thank You