Pre-alignment solutions applied to girders 1/19 Sylvain GRIFFET, 06/07/2010.

Slides:



Advertisements
Similar presentations
3. Surface levelling Use of a surface levelling: a)addition of altimetry to a planimetric map b)determination of volume using a net of squares 1.
Advertisements

Frequency Scanning Interferometry (FSI) measurements
Solomon William KAMUGASA
Micro-triangulation for high accuracy short range measurements of dynamic objects Vasileios Vlachakis 1 st PACMAN Workshop February 2015 CERN, Geneva,
Metrology and pre-alignment of the components of CLIC in the PACMAN project S. W. Kamugasa, V. Vlachakis CLIC Workshop January 2015 CERN, Geneva,
Alignment of DB and MB quadrupoles Hélène MAINAUD DURAND 17/11/2011 With a lot of input from Sylvain GRIFFET.
Instrument Tests with the new Leica AT401 Georg Gassner September 16 th 2010.
Optical Alignment with Computer Generated Holograms
Use of a commercial laser tracker for optical alignment James H. Burge, Peng Su, Chunyu Zhao, Tom Zobrist College of Optical Sciences Steward Observatory.
Workshop TS May 2008 GENERAL CLIC ALIGNMENT Progresses and strategy. Hélène MAINAUD DURAND, TS/SU/MTI.
Robert Ruland Intra Girder Assembly and Alignment - October 20, 2005 Internal LCLS Undulator Alignment and Motion Review 1 Intra.
A Laser Based Alignment System for the CLIC project
1 Institute of High Energy Physics 13/09/2010 Comparison and Study in Measurement Accuracy of Height Difference between Laser Tracker and Level Men LingLing.
MICE Alignment and Support Structure Tony Jones and Yury Ivanyushenkov Engineering Department RAL.
© NMISA 2010 Multilateration Laser Tracker Systems Speaker : Pieter Greeff
Dimensional Metrology Dimensional Metrology Program Steve Phillips Program Manager MEL Metrology Support for Laser Trackers and Scanners Supports Industrial.
Metrology for NCSX Steve Raftopoulos and the NCSX Metrology Team.
H. MAINAUD DURAND on behalf of the CLIC active pre-alignement team with 3D views and data from Hubert Gerwig, Richard Rosing and Juha Kemppinen Pre-alignment.
PACMAN Workshop OUTLINE Introduction ESR 3.1 Challenges - Stability budget and Precision Mechanical Design - Precision Assembly of MBQ and BPM - System.
1/9 Hélène Mainaud Durand Sylvain GRIFFET, 28/11/2011 BE/ABP-SU/ Adjustment of 4 Drive Beam Quads positions on TM0 CLIC girders EDMS Document No
Measurement report of Boostec girders Control after receipt Sylvain GRIFFET, 13/12/2010 Measurements performed on the 1 st and 2 nd of December 2010 with.
H. SCHMICKLER Alignment challenges for a future linear collider.
Measurement report of Boostec girders 1/13 Sylvain GRIFFET, 15/11/2010 Measurements performed on the 28th of October 2010 with the Laser Tracker LTD500.
H. MAINAUD DURAND, on behalf of the CLIC active pre-alignment team CLIC ACTIVE PRE-ALIGNMENT STUDIES: STATUS FOR CDR AND PROSPECTS FOR TDR PHASE.
Accuracy and Precision
LASER AND ADVANCES IN METROLOGY
Tilt meter fiducial Guide rail Abstract This poster covers the survey and alignment techniques selected for installation of the SPIRAL2 accelerator devices.
H. MAINAUD DURAND PACMAN WP1 OUTLINE Tasks & role of associated partner Plans for training.
Dmitry Gudkov BE/RF/PM CLIC Module Working Group PROTOTYPE TWO-BEAM MODULES (CLEX) Supporting and positioning system for CLEX modules main conclusions.
1/12 Sylvain GRIFFET, 17/10/2011 BE/ABP-SU/ Simulations of laser tracker AT401 measurements on TM0 CLIC girders EDMS Document No
STATUS of the final PACMAN bench integration PACMAN meeting 11/06/2015 Hélène Mainaud Durand.
BEPCII Prealignment Installation Survey and Alignment Accelerator Center of IHEP Xiaolong Wang
1962 First CMM DEA (Italy) Ahmed CHERIF CERN Metrology lab. CLIC TECHNICAL COMMITTEE – EDMS : EDMS :
ABSTRACT The Compact Linear Collider (CLIC) is currently under development at CERN as a potential multi-TeV e + e – collider. The manufacturing and assembly.
Dmitry Gudkov BE-RF-PM CLIC Module Working Group Engineering design of the adjustable supporting system for DBQ.
Validation of the Measurement Performance of a 3-D Vision Sensor by means of a Coordinate Measuring Machine Giovanna Sansoni1, Simone Carmignato2, Enrico.
CALIBRATION Erwin Pilch Prevessin Site, F CERN CEDEX, FrancUniversity of Technology Graz, Austria 9 th August
CLIC Module meeting, 22/08/2011 N. Chritin (EN/MME) Cradles design for CLIC module supporting system (EDMS )  General principle  Main inputs an.
Short range alignment strategy in CLEX and first results CLIC Workshop January 2015 on behalf of : Hélène Mainaud-Durand, Mateusz Sosin Mathieu.
CLIC Module WG 20/07/2009 H. MAINAUD DURAND, BE-ABP/SU Pre-alignment system and impact on module design.
Instrument Calibration.  As previously discussed the principle of measurement is comparing a component against a known standard therefore any equipment.
Survey, Alignment and Metrology Fiducials Requirements Fabien Rey ESS Survey, Alignment and Metrology Group ACCELERATOR TECHNICAL BOARD 23/09/2015.
Survey, Alignment and Metrology Fabien Rey Pawel Garsztka ESS Survey, Alignment and Metrology Group.
Survey, Alignment and Metrology Fabien Rey Pawel Garsztka ESS Survey, Alignment and Metrology Group Interface Workshops for ESS Warm-Linac: ISrc - LEBT.
cern.ch 1 A. Samoshkin 28-Feb-2011 Progress on CDR module design.
CLIC Beam Physics Working Group CLIC pre-alignment simulations Thomas Touzé BE/ABP-SU Update on the simulations of the CLIC pre-alignment.
1 Thermal tests planning for mock-up TM0 Thermal tests planning for CLIC prototype module type 0 July 17,
Fiducialisation and initial alignment of components for CLIC Mateusz Sosin on behalf of the CLIC active pre-alignment team CLIC Workshop 2015.
Pre-alignment of quadrupoles 1 CLIC stabilization day, STARTSLIDE PRE-ALIGNMENT OF THE MAIN BEAM QUADRUPOLES Hélène MAINAUD DURAND.
1) News on the long scale length calibration 2) Results of the two surveys performed on plane 7 Set 1: morning of 12/11/2004 Set 2: morning of 19/11/2004.
Measurements of DB supporting systems Fiducialisation Sylvain GRIFFET, 21/03/2011 Measurements performed in February and early March /13 EDMS n°
Company LOGO Technology and Application of Laser Tracker in Large Space Measurement Yang Fan, Li Guangyun, Fan Baixing IWAA2014 in Beijing, China Zhengzhou.
CLIC08 Workshop, CERN October 2008 PRE-ALIGNMENT STUDY STATUS AND MODEL FOR THE BEAM DYNAMICS SIMULATIONS TS/SU/MTI Thomas TOUZE Hélène MAINAUD DURAND.
PACMAN : technical objectives Hélène Mainaud Durand.
BRAINSTORMING ON LASER BASED SOLUTIONS FOR CLIC PRE-ALIGNMENT INTRODUCTION Hélène MAINAUD DURAND, BE/ABP/SU, 09/02/2010 Status of the study CLIC pre-alignment.
H. MAINAUD DURAND on behalf of the CLIC active pre-alignment team Status on CLIC pre-alignment studies.
Survey for SPL Dominique Missiaen BE-ABP/SU. Outline 12/11/2008 Dominique Missiaen BE-ABP-SU, Survey for SPL 2  Scope & Main Parameters  Technical Description.
Laser beam trajectory measurement with a CCD camera Georg Gassner.
Last results from tests
on behalf of the CLIC active pre-alignment team
Alignment methods developed for the validation of the thermal and mechanical behavior of the Two Beam Test Modules for the CLIC project Hélène MAINAUD.
Recent developments on micro-triangulation
Workshop on Tau-Charm at High Luminosity
List of changes and improvements for the next generation CLIC module
Background With new accelerators delivering beams always smaller and more energetic, requirements for very precise beam alignment become more and more.
Towards a common mechanical interface
Alignment challenges for a future linear collider
Contacts for underside connectors
MEASUREMENT AND INSPECTION
Alignment of the first two magnet system modules of Wendelstein 7-X
Presentation transcript:

Pre-alignment solutions applied to girders 1/19 Sylvain GRIFFET, 06/07/2010

2/19 Sylvain GRIFFET, 06/07/2010 Plan Our measurement systems (and associated uncertainties) The measurement systems that we would like to test in the Lab Loss of accuracy because of interfaces or holders The different methods depending on what to measure What we would like to add on the girders for the Lab CONCLUSION Pre-alignment solutions applied to girders

3/19 Sylvain GRIFFET, 06/07/2010 Our measurement systems (and associated uncertainties) This instrument follows a target type spherical prism (0.5''or 1.5'‘ usually) thanks to a tool of target recognition and engines. Uncertainty around of 30μm in the case of a network of points put on a 2m long object. Pre-alignment solutions applied to girders Laser Tracker The Laser Tracker is an opto-electronic instrument equipped with an interferometer, a high accuracy distance-meter and angular encoders (this is where the Laser Tracker is not so good).

4/19 Sylvain GRIFFET, 06/07/2010 Our measurement systems (and associated uncertainties) Photogrammetry The principle of photogrammetry is the analysis of photographic pictures taken from different points of view. For example of the measurement of a 1.6m long accelerating structure. Pre-alignment solutions applied to girders

5/19 Sylvain GRIFFET, 06/07/2010 Our measurement systems (and associated uncertainties) photogrammetry Targets, recognized by the software, are put on the object to be measured. The scaling of the points network is done by measuring 6 points on 3 carbon rods (distance between two targets known with an accuracy better than 10µm). Sixty shots were needed to measure the 48 targets. The uncertainty that can be expected on the determination of these 48 points around f 15μm. Pre-alignment solutions applied to girders

6/19 Sylvain GRIFFET, 06/07/2010 Our measurement systems (and associated uncertainties) Micro-Triangulation The principle of the Micro- Triangulation is to use the full potential of a theodolite by substituting a CCD camera instead of the eye of an operator. With a target recognition software, a ball or photogrammetric target for example, the angular precision sights on this target is of the order of 2.5μm per meter. Pre-alignment solutions applied to girders

7/19 Sylvain GRIFFET, 06/07/2010 Our measurement systems (and associated uncertainties) Micro-Triangulation The system doesn’t provide distance measurement, so it is necessary to make a scaling of the network using interferometric measurements. The expected accuracy for the measurement of a network of the module CLIC size is the order of 5 to 10µm. Pre-alignment solutions applied to girders The accuracy of the determination of a distance by the interferometer is better than one micrometer.

8/19 Sylvain GRIFFET, 06/07/2010 The measurement systems that we would like to test in the Lab New Laser Tracker Leica AT401 The measurement principle and the distance-meter are the same as our Laser Tracker but this one uses the angular encoders of the most accurate Leica tacheometer. The intrinsic accuracy of this system is ±15µm + 6µm per meter at 3σ. Pre-alignment solutions applied to girders

9/19 Sylvain GRIFFET, 06/07/2010 The measurement systems that we would like to test in the Lab HAMAR alignment system The measurement principle is based on the emission of a rotating laser beam, which produces one or more reference laser plans (up to 3 plans according to the device model), This system is used in the industry to align machines on an assembly line for example. Microplan data : Measurement range : 25mm. Announced accuracy of 2.5µm/m. Pre-alignment solutions applied to girders

10/19 Sylvain GRIFFET, 06/07/2010 The measurement systems that we would like to test in the Lab Measuring arm This tool is a kind of portable CMM, measuring with a sensor; for example, the measuring arm Faro Quantum 1.2m: "Measurement volume” of 2.4m, equipped with a sensor, 7 axes of rotation, carbon fiber skeleton, a temperature sensor at each joint, internal battery or mains connection, the model Quantum is the most accurate of the 3 Faro arm range. Manufacturer's data: Repeatability tests on cone: 18μm Accuracy on length, maximum deviation: 25μm Pre-alignment solutions applied to girders

11/19 Sylvain GRIFFET, 06/07/2010 Loss of accuracy because of interfaces or holders Spherical prism holder As there is no clearance between the shank holder and its bore (link embedding), there is no loss of accuracy due to this element. The center of the sphere determined by the CMM is the same (excluding errors due to the sphere) as measured by our instruments. Pre-alignment solutions applied to girders

12/19 Sylvain GRIFFET, 06/07/2010 Loss of accuracy because of interfaces or holders Spherical prism 1.5’’ The error of sphericity and mirrors centering in a spherical prism (0.5''or 1.5'') are the order of 6μm. It is recommended to use the same prism to measure all the points. Pre-alignment solutions applied to girders

13/19 Sylvain GRIFFET, 06/07/2010 Loss of accuracy because of interfaces or holders Ceramic or plastic balls The error of sphericity of this type of ball is less than the micrometer. Pre-alignment solutions applied to girders

References surfaces The reference surfaces that we will measure on the girder are those on V- supports, the surfaces upon which the DBQ holders will be fixed and surfaces necessary for assembly girders with cradles. 14/19 Sylvain GRIFFET, 06/07/2010 The different methods depending on what to measure All presented methods are able to measure these surfaces, however, there will be an interface design work to do for photogrammetry, Micro-Triangulation and Hamar system. Pre-alignment solutions applied to girders

Sphere 1.5’’ holder The holders on the cradles are provided to receive the spherical prisms 1.5’’. These prisms are measurable by the Laser Trackers, Micro- Triangulation and the measuring arm. 15/19 Sylvain GRIFFET, 06/07/2010 The different methods depending on what to measure Pre-alignment solutions applied to girders

Balls of sensor interfaces The ball center is determinable by Micro-Triangulation, the measuring arm and the Laser Trackers. 16/19 Sylvain GRIFFET, 06/07/2010 The different methods depending on what to measure Pre-alignment solutions applied to girders

These points will be necessary to check the V- supports alignment when the girder will be loaded by its components, so when the references surfaces will be not accessible. 17/19 Sylvain GRIFFET, 06/07/2010 What we would like to add on the girders for the Lab Some points on both sides of the V-supports Pre-alignment solutions applied to girders

In a first time, this network will be necessary to follow the girder deformations due to the load. Secondly, the network will be useful to determine the alignment defects of the components on the girder. 18/19 Sylvain GRIFFET, 06/07/2010 What we would like to add on the girders for the Lab A points network on the girder Pre-alignment solutions applied to girders

19/19 Sylvain GRIFFET, 06/07/2010 CONCLUSION We dispose of several tools, relatively accurate, useful without particular development. During the Lab test, we would like to test and validates alternative methods. The procedures for connecting the different coordinate systems remain to be defined (to move from beam system to the V-supports system, to move from the V-supports system to the girder system….). It is necessary to collaborate with Ahmed CHERIF to define some points accurately measurable by the CMM and by our methods. Pre-alignment solutions applied to girders