CHAPTER 10 Time Control Control With Timers Prepared by Adam Keeth for EE483 4-29-03.

Slides:



Advertisements
Similar presentations
Sequential Process Control
Advertisements

KEB COMBIVERT F5-M Exercises.
Programming with Ladder Logic
Contactors & Relays.
Programming Logic Controllers
HYDRAULICS & PNEUMATICS
Discrete Control Logic 1. Pneumatic circuits - Low forces - Discrete, fixed travel distances - Rotational or reciprocating motion Main components: compressor,
©2011, The McGraw-Hill Companies, Inc. Chapter 4.
Programmable Logic Controller PLC
4/24/05 BAE Motor Control PLCs and Ladder Logic An Introduction.
Ladder Logic PLC Programs are made up of combinations of AND; OR; NAND; NOR; and other gates, along with timers, inputs, outputs, counters, comparators,
FUNCTION OF OUTPUT CONTROLLER AND APPLICATION
DC Motors, Stepper Motors, H-bridges DC Motors Stepper Motors Motor Control Circuits – Relays – H-bridges.
Lesson 15: Dc Motor Control Components and Diagrams
Programmable Logic Controller Internal Operations
Programmable Logic Controllers
Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams
Pump Application Interface. 30 October 2006 Overview Increases the functionality of the soft starter for pumping applications - four additional trip inputs.
Industrial Controls. Industrial control devices range from simple knife switches to more complex solid state sensors. The type of control device selected.
SECTION 4 ELECTRIC MOTORS UNIT 19 MOTOR CONTROLS.
Logic Functions OR Operation
Section 4: Electric Motors
Timers.
BEX100 – Basic Electricity
Electro-Pneumatics Module 1
Troubleshooting Electric Control Devices
Chapter 6 Control_relays.
Industrial Machine Control
Programmable Logic Controllers
HYDRONIC HEATING AQUASTATS
Continue The information provided in this training module covers the schematic flow charts for all ovens and ranges that utilized a preheat board, Self.
Ladder Diagram Symbols. Study the various symbols identified in this presentation. Once you have memorized the different symbols and can name them, take.
Operation Sabbath Mode - SELECT PROGRAM - Lights, alarms and fans Normal Sabbath Overview.
Chapter 8.
PROGRAMMABLE LOGIC CONTROLLER DNT 353/3
Control Technology and Automation
Pneumatics.
Chapter 4 Overload Relays.
PROGRAMMABLE LOGIC CONTROLLER (PLC) AND AUTOMATION
TRISHUL Winding Solutions Pvt Ltd. RELAY COIL A relay is an electrical switch that uses an electromagnet for automatically off/on the switch instead of.
Unit 4 Symbols.
Industrial Electronic Department Copyright of German Malaysian Institute. All rights reserved.
CHAPTER 1 ELECTRICAL CONTROLLER EQUIPMENT
Logic Functions and Symbols
Electrical Switches 1 st SEM Information Technology UNIVERSAL COLLEGE OF ENGINEERING & TECHNOLOGY SUBJECT: ELEMENTS OF ELECTRICAL ENGINEERING( )
Interfacing to External Devices  Explore Digital Interfaces techniques  Introduce some complex optical devices and how to interface them  Describe methods.
PRESENTATION ON THE TOPIC By: Rahul agarwal. INTRODUCTION  Overload protection circuit are required in inverters and uninterrupted power supplies to.
Ladder Concept.
TIMERS Used to carry out tasks which involve time delay and time counting. A timer circuit is specified by stating the interval to be timed and the conditions.
Symbols and Schematic Diagrams
We apply 120 VAC to the HM Unit (Remember to check polarity!) Our primary step down T/X provides power to terminal “X” and “COM” on the ignition control.
Actuators and Control, Part 4 Grant Agreement No LLP UK-LEONARDO-LMP Project acronym: CLEM Project title: Cloud services for E-Learning.
Best Battery Monitor. Primary Current Injection Source APCI- 600:- The APCI-600 is a programmable AC high-current source designed specifically for utility-substation.
Fluid Power Control.
1 Introduction to PLCs: Programming Counters ELMT Basic Programmable Logic Controllers Chapter 0x_W Source: www Based on Ch 8 of Frank D. Petruzella.
Chapter 7.
Programming Timers.
Input-Output-Process Demo
Input-Output-Process Demo
Retentive On Delay Timers
Presentation transcript:

CHAPTER 10 Time Control Control With Timers Prepared by Adam Keeth for EE

When Should One Use a Timer? Major function is to place information about elapsed time into a control circuit. Major function is to place information about elapsed time into a control circuit. Timers are not always the best way to control a circuit Timers are not always the best way to control a circuit Overshoot/Undershoot example Overshoot/Undershoot example Critical criteria (time, pressure, temperature, or position) Critical criteria (time, pressure, temperature, or position)

Timers and Time-Delay Relays Time Delay Relays Time Delay Relays Devices having a timing function after a timer coil has been energized. Then either NO or NC contacts activate. The only time function is the preset time. Devices having a timing function after a timer coil has been energized. Then either NO or NC contacts activate. The only time function is the preset time. Timers ( Much more versatile) Timers ( Much more versatile) The time function may start on one or many contacts at energizing, or at a preset time after energizing. The time function may start on one or many contacts at energizing, or at a preset time after energizing.

The Timer (continued) The timer opens or closes electrical circuits to selected operations according to a timed program. The timer opens or closes electrical circuits to selected operations according to a timed program. Timing function begins when the timer receives an electrical signal initiated through a manual switch or automatic sensor. Timing function begins when the timer receives an electrical signal initiated through a manual switch or automatic sensor. Preset time is user-defined. Preset time is user-defined.

Types of Timers 2 Primary Types: 2 Primary Types: Synchronous Motor Driven Synchronous Motor Driven Solid-State Type Solid-State Type Other Types: Other Types: Dashpot Dashpot Mechanical Mechanical Electrochemical Electrochemical Thermal Thermal Timing Functions: Timing Functions: ON delay Timing function after energizing. OFF delay Timing function after deenergizing.

Synchronous Motor Driven Timer Very Common in Industrial Applications: Very Common in Industrial Applications: Available in three types: Available in three types: Reset type Reset type Repeat-cycle type Repeat-cycle type Manual-set type Manual-set type Symbols Symbols

Reset Timers Use a clutch and a synchronous motor. Most reset timers have 3 contacts to provide output to the electrical circuit. Each contact has three conditions: Use a clutch and a synchronous motor. Most reset timers have 3 contacts to provide output to the electrical circuit. Each contact has three conditions: Reset – clutch and motor deenergized. Reset – clutch and motor deenergized. Timing – clutch energized. Timing – clutch energized. Timed Out – motor deenergized. Timed Out – motor deenergized. Sequence Chart – Figure 10-5

Repeat –Cycle Timers This type of timer is used to control several electrical circuits in a predetermined sequence. This type of timer is used to control several electrical circuits in a predetermined sequence. Adjustable cams on the motor shaft determine the point of closing and opening a switch during a revolution. In many cases, these cams are screwdriver-adjustable. Adjustable cams on the motor shaft determine the point of closing and opening a switch during a revolution. In many cases, these cams are screwdriver-adjustable. Activation time and duration time are adjustable. Activation time and duration time are adjustable. Most include external calibrated discs to observe the progress of the timer (Figure 10-9). Most include external calibrated discs to observe the progress of the timer (Figure 10-9).

Manual-Set Timers This type requires manual operation to activate the timer. This type requires manual operation to activate the timer. Timer runs and stops after a selected time. Timer runs and stops after a selected time. Figure 10-10A&B

Solid State Timers Microprocessor-type timers are the most versatile timers available. Microprocessor-type timers are the most versatile timers available. Many incorporate keypad input and digital/LCD readout. Many incorporate keypad input and digital/LCD readout. Very accurate Very accurate 100% accurate for count operations. 100% accurate for count operations. Within 50 ms (or 0.5%) accurate for timing operations. Within 50 ms (or 0.5%) accurate for timing operations. Can retain data for many years. Can retain data for many years. Most are repeat-cycle capable. Most are repeat-cycle capable.