Correlation between Preoperative cataract grading by Scheimpflug imaging and phaco time and power US in phacoemulsification. Bruno Valbon; Ana Canedo;

Slides:



Advertisements
Similar presentations
TESTUPLOAD. TORSIONAL PHACOEMULSIFICATION In January 2006 Alcon Surgical incorporated Ozil torsional into the Infiniti Vision System. Unlike the conventional.
Advertisements

OHM Comparative quantification of ingress of trypan blue into anterior chamber following microcoaxial phacoemulsification with torsional or longitudinal.
Comparison of Endothelial Cell Count by Manual and Automated Methods in Normal Corneas and in Fuchs' Endothelial Dystrophy Somasheila I Murthy, Debarun.
Comparison between phaco-chop, divide-conquer and stop & chop phaco-technique according to the cataract density Hae ri Yum, M.D., Man Soo Kim, M.D. Eun.
Katsuya Yamazoe, MD, Takefumi Yamaguchi, MD, Kazuki Hotta, MD, Yoshiyuki Satake, MD, Kenji Konomi, MD, Seika Den, MD, Jun Shimazaki, MD Presented by: Abdulrahman.
Long-Term Follow-Up of Toric Intraocular Lens Implantation for Keratoconus Alejandro Navas, MD, MSc, Martha Jaimes, MD, Jesús Cabral, MD, Arturo Ramirez.
Corneal Biomechanics, Pachymetric Progression Profile and Corneal Volume: Indices for Detecting Ectasia and Screening Refractive Candidates Renato Ambrósio.
E-Poster ALC Canedo, MD 2010 Rio de Janeiro CornealTomograhyandBiomechanics Study Group Study Group Comparative Study of Corneal Biomechanical Properties.
Purpose We studied the interdevice agreement of three systems in the different measurements of the corneal and anterior segment biometric parameters. The.
Protecting the Corneal Endothelium
Astigmatism Following 2 IOL Injection Techniques: Wound Assisted Versus Wound Directed Jay J. Meyer, MD Hart B. Moss, MD Kenneth L. Cohen, MD University.
A Prospective, Randomized, Comparative Evaluation of Patients with Contralateral Implantation of Two Aspheric Acrylic Intraocular Lenses R. Cionni, MD.
INTRAOPERATIVE FLAP COMPLICATIONS IN LASIK SURGERY PERFORMED BY OPHTHALMOLOGY RESIDENTS IN TRAINING Arturo Gómez-Bastar MD Arturo Ramirez-MirandaMD Lorena.
Clinical evaluation of foldable acrylic phakic IOL (fP) implantation ASCRS, San Diego, 2011 A.John Kanellopoulos, MD Professor NYU Medical School, NY Director,
Anterior Chamber Depth, Iridocorneal Angle Width, and Intraocular Pressure Changes After Phacoemulsification: Narrow vs Open Iridocorneal Angles Huang.
Placement of Toric Intraocular Lens and the Long-term Change in the Axis of Corneal Astigmatism after Sutureless Cataract Extraction by Phacoemulsification.
Capsular Tension Rings: Current Indications and Outcomes Maryam Mokhtarzadeh, MD Jayne S. Weiss, MD John M. Ramocki, MD No financial conflicts to disclose.
E-Poster ALC Canedo, MD 2010 Rio de Janeiro CornealTomograhyandBiomechanics Study Group Study Group The impact of reference body selection for calculating.
So-Hyang Chung, MD, PhD, Choun-Ki Joo, MD, PhD Department of Ophthalmology and Visual Science, College of Medicine, The Catholic University of Korea, Seoul,
Hyun Seung Kim, M.D. Department of Ophthalmology, St. Mary’s hospital, The Catholic University of Korea Changes in Astigmatism After Clear Corneal Temporal.
Transparency of Transition from 2.75 mm to 1.8 mm Microincision Surgery Jay McDonald II, MD Adjunct Clinical Professor University of Arkansas School of.
Title slide Surgical Peculiarities in Cases of Irido- fundal Coloboma Having Cataract Extraction Prof Sudarshan K. Khokhar, MD Dr Sanjay K. Mishra, MS.
Dept. of Ophthalmology, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany. Outcome after big-bubble deep anterior lamellar keratoplasty.
Evaluation of Corneal Parameters and Spherical Aberration After DSAEK Measured with Pentacam System Orkun Muftuoglu, Pawan Prasher, R. Wayne Bowman, Steven.
Phacoemulsification in eyes with previous anterior chamber phakic IOL surgery Walton Nosé, MD, PhD 1,2 Adriana dos Santos Forseto, MD 1 Mariana Ávila,
1.8 mm Cataract Surgery: Clinical Results 6 Months after Coaxial and Biaxial MICS and Implantation of a New Micro- incision IOL Rosa Braga-Mele, M. Ed,
Hong Kong Eye Hospital Ms Frenchy Chiu Dr Victoria Wong IOL master
Hong Kong Eye Hospital Biometry Audit 2011 SN60WF IOL Dr. Rose Chan Resident, Hong Kong Eye Hospital.
Spending 40 cc in an entire Cataract Surgery. Comparative study. Arturo Pèrez-Arteaga M.D. Medical Director & Founder Centro Oftalmològico Tlalnepantla,
Occurrence of Retinal Detachment After Cataract Surgery Peter Jeppesen MD, PhD and Thomas K. Olsen, MD, DMSc Department of Ophthalmology Århus University.
DSAEK Outcomes in Normal and Abnormal, High-Risk Eyes at an University Practice Hugo Y. Hsu and Sean L. Edelstein The authors have no financial interest.
INTRAOCULAR LENS POWER CALCULATION BY IMMERSION A-SCAN BIOMETRY VERSUS CONTACT A-SCAN BIOMETRY MEASUREMENTS BEFORE CATARACT SURGERY Burak Bilgin**, M.D.,
Khairidzan Mohd Kamal MD
Jorge L. Alio MD PhD Ma. Cecilia C. Agdeppa MD VISSUM-Instituto Oftalmologico de Alicante ASCRS Convention 2010 Boston Efficiency of MicroIncision Cataract.
Rio de Janeiro Corneal Tomography and Biomechanics Study Group Dr. Ambrósio is consultant for Oculus Optikgeräte GmbH (Wetzlar, Germany) Agreement of Artificial.
Jamie Ng, Marcus Tan, Lennard Thean National University Health System
E-Poster Price Vision Group & Cornea Research Foundation of America Descemet - Stripping Endothelial Keratoplasty :Survival Outcomes in Eyes with Pre-
Surgeon Generated Tip Travel Comparing Longitudinal vs. Torsional Ultrasound with Interjected Longitudinal Segments James A. Davison, MD FACS Wolfe Eye.
The Effect of Corneal Anterior Surface Eccentricity on Astigmatism after Cataract Surgery Choul Yong Park MD 1 Sung Jun Lee MD 1 Prabjot Channa MD 2 Roy.
Adriana S. Forseto1, MD Walton Nosé1,2, MD
E-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group The study of the correlations of the optic disc size with Cornal Geometry and Biomechanical.
Rio de Janeiro Corneal Tomography and Biomechanics Study Group CORNEAL TOMOGRAPHY AND BIOMECHANICAL FINDINGS OF CONCOMITANT KERATOCONUS AND CORNEAL GUTTATA.
E-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group e-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group Clinical.
Wound Architecture and Wound Healing after Torsional and Longitudinal Phaco in a Rabbit Model Carolina Eyecare Physicians, LLC Research Assistant Professor.
No author has any financial or proprietary interest in any materials or methods mentioned Seung Hyun Kim M.D. ; Tae Hoon Oh M.D. Department of Ophthalmology.
Johns Hopkins Hospital
Anesthetic Effect of Topical Agents in Cataract Surgery Ross B. L. MacIntyre, MD Paul S. Koch, MD Dr. Ross MacIntyre has no financial interests to disclose.
Comparison of Central Corneal Thickness, Anterior Chamber Depth, and Central Corneal Power Measurements between Two Scheimpflug Imaging Systems Yuichi.
Investigation of Multifocal Toric IOLs to Compensate for Corneal Astigmatism and to Provide Near, Intermediate, and Distance Vision José L. Rincón, MD.
Rio de Janeiro Corneal Tomography and Biomechanics Study Group CONCOMITANT KERATOCONUS AND FUCHS DYSTROPHY: TWO DISEASES IS BETTER THAN JUST ONE? Dr. Ambrósio.
Minimizing Risk in Visian ICL Implantation.
Corneal shape and corneal aberrations after MicroIncision Cataract Surgery (MICS) NOCHEZ Y, BUREL B, MAJZOUB S, PISELLA PJ C.H.U.
Endothelial cell loss after cataract surgery P.Bruttini MD,G.Acerbi MD,L.Vitale MD, M.Sironi. CLINICA S.CARLO PADERNO DUGNANO THE AUTHORS REPORT NO CONFLICT.
Corneal Endothelial Cell Loss Results in a Comparison of Longitudinal vs. Torsional with Vacuum Demand Interjected Longitudinal (IP) Phacoemulsification.
Liquifaction Method and Extent of Posterior Capsule Opacification: Two-Year Follow-up Marie Kalfertova, Mariya Burova, Pavel Rozsival, Nada Jiraskova Nada.
Assessment of Anterior Segment Measurements with Swept Source Anterior Segment OCT Before and After Trabectome Surgery Handan Akil, Mayss Al-Sheikh, SriniVas.
CORNEAL ENDOTHELIAL PROFILE AFTER FERRARA RING IMPLANTATION Leonardo Torquetti, MD, PhD Paulo Ferrara, MD, PhD Paulo Ferrara Eye Clinic Belo Horizonte.
Comparison of two differents ultrasound mode in BMICS technique : Pulse and Continuous US Danielle DEIDIER M.D. Clinique Saint Vincent Toulon - France.
Comparison of Endothelial Cell Loss After Phacoemulsification Performed by Third Year Residents and Anterior Segment Surgeons Alexandra Braunstein, MD.
Clinical applications of Scheimpflug imaging in cataract surgery
Prospective Study Comparing Outcomes of Torsional versus Traditional Phacoemulsification Systems on Dense Cataracts Bonnie An Henderson MD, Kelly J Grimes.
Comparison in Reduction of Preoperative Astigmatism after Cataract Surgery with Toric IOLs versus Limbal Relaxing Incisions Alexander Chop PhD MD (no.
Effects of the “Pop & Prechop” Supracapsular Phacoemulsification Technique on Endothelial Cell Counts and Corneal Clarity Brandon Rodriguez, MD Michael.
Bruno Valbon, Ana Caiado, Ricardo Louzada, Renato Ambrosio Jr *.
Sherleen Chen, M.D. and Roberto Pineda II, M.D.
Corneal Biomechanical Assessment using Dynamic Ultra High-Speed (UHS)
New 3-Dimensional Scheimpflug Analysis of Cataract Density
Continuous vs Pulsed Oscillatory Ultrasound in cataract phacoemulsification The authors have not financial interest in the subject matter of this poster.
Ecological cataract surgery
Young Jeung Park, M.D. Ph.D. Won Suk Choi, M.D.
Presentation transcript:

Correlation between Preoperative cataract grading by Scheimpflug imaging and phaco time and power US in phacoemulsification. Bruno Valbon; Ana Canedo; Leonardo Pimentel; Isaac Ramos; Ricardo Louzada; Renato Ambrósio Jr. * Dr. Ambrosio is a consultant to Oculus and in the speaker bureau for Reichert, Alcon and Allergan

Purpose : To analyze the correlation between patient nuclear score (PNS) by Scheimplufg imaging and phaco time and power US in patients who had uneventful clear cornea phacoemulsification Valbon B; Canedo A; Pimentel L; Ramos Isaac, Louzada R. Ambrosio Jr R

INTRODUCTION The current standard for grading cataracts is the Lens Opacification Classification System III (LOCS III). This system is, however, potentially subjective and the results are open to interpretation. An objective and reproducible method of cataract evaluation is not yet available. Furthermore, there is no universal means by which to correlate the objective cataract evaluation with the amount of energy needed to remove a cataract during phacoemulsification. The efficiency of ultrasound (US) energy use in phacoemulsification systems is critical. Lower levels of US power can limit endothelial cell damage; therefore, it makes sense to plan phaco surgery with the lowest levels of US power needed based on cataract density. Is common for surgeons to alter phaco settings intraoperatively according to the den- sity of the cataract. It would be more efficient to set phaco variables preoperatively based on objective and reproducible cataract density results. Valbon B; Canedo A; Pimentel L; Ramos Isaac, Louzada R. Ambrosio Jr R

METHODS Patients scheduled to have cataract surgery by the same surgeon (RA) had similar preoperative evaluations, including Pentacam Scheimpflug assessment using the PNS. Patients were excluded if preoperative examinations indicated a need for complex cataract surgery that could lead to complications. 22 eyes from 22 patients who had uneventful clear cornea phacoemulsification and foldable IOL implantation were included. Phaco time and power US were performed after surgery each patient. The Test Kolmorogov-Smirnov was used to evaluate normal distribuition. The correlations were evaluated with Pearson rank correlation. A P value lower than 0,05 was considered statistically significant. PNS x Phaco Time and PNS x US power were correlations realized. Valbon B; Canedo A; Pimentel L; Ramos Isaac, Louzada R. Ambrosio Jr R

METHODS (PNS – pentacam nucleus staging) Valbon B; Canedo A; Pimentel L; Ramos Isaac, Louzada R. Ambrosio Jr R

METHODS PNS 1 PNS 3 (PNS – pentacam nucleus staging) X LOCS III Valbon B; Canedo A; Pimentel L; Ramos Isaac, Louzada R. Ambrosio Jr R

Results : 22 eyes of 22 patients were studied. Correlation between PNS x Phaco Time was p < 0,0050 and RP (Rank - Pearson) 0,5757 (Graphic 1). Correlation between PNS x Power US was p < 0,0029 e RP( Rank - Pearson) de 0,6034 (Graphic 2). Valbon B; Canedo A; Pimentel L; Ramos Isaac, Louzada R. Ambrosio Jr R

DISCUSSION The ability to objectively and reproducibly assess pre-operative characteristics of the nuclear component of a cataract to determine its grade would have value in preoperative surgical planning. The most widely used cataract grading system, the LOCS III, is open to interpretation because of its subjective nature; thus, surgeons have no analytical tool to link cataract grade and surgical settings. In this study, a Scheimplug imaging system was used to determine objective cataract grades, with the phaco parameters adjusted preoperatively and to realize correlations between phaco time, power US and PNS. This present study found a statistically significant between PNS, phaco time and power US. In conclusion, customizing phaco parameters based on an objective cataract grading may be a means to improve phaco efficiency. Valbon B; Canedo A; Pimentel L; Ramos Isaac, Louzada R. Ambrosio Jr R

Correlation between Preoperative cataract grading by Scheimpflug imaging and phaco time and power US in phacoemulsification Bruno Valbon; Ana Canedo; Leonardo Pimentel; Isaac Ramos; Ricardo Louzada; Renato Ambrósio Jr. valbonbruno@ig.com.br Thank you !! Valbon B; Canedo A; Pimentel L; Ramos Isaac, Louzada R. Ambrosio Jr R