Residential Fire Sprinkler symposium Ontario Convention Center.

Slides:



Advertisements
Similar presentations
State Fire Marshal Question and Answer Session with the Louisiana Automatic Fire Alarm Association March 19, 1999.
Advertisements

Policy and Social Change for Healthier Designs in Building Sustainable Fire Safe Homes Princella Lee-Bridges, MSN, RN Bridges From Augusta, Inc. Tim Travers.
“TI” Ohhhh….. (TIO) (No TIO is not a person!) What is it all about?
Chapter 20 Plumbing Plans.
SPRING CONVENTION MARCH 2006 Requirements for “On-Line” Power Generation in Accordance with the International Building Code Presented by Richard C. Berger.
BS9990 : 2015 Updates and/or Changes
Nathan Saunders, P.E. Maine Drinking Water Program Public Water System Owner & Operator Responsibility.
N.F.P.A. 13R Justin Bohlmann FIR-204.
13D Systems What, Why and How Oregon Fire Sprinkler Coalition.
North Carolina Chief 101 Firefighter Safety, OSHA and NFPA.
Residential Fire Sprinklers A Little Bit of History and The What, Where, Who, When and How Questions Richard J. Prospal – American Society of Sanitary.
Residential Fire Sprinklers in the 2010 CA Codes
RESIDENTIAL FIRE SPRINKLER SYSTEMS
Backflow Preventor. (4) The Contractor V may install the cross-connection backflow prevention device as defined in this chapter on new installations.
Chapter 11 Fire-Related Codes and Ordinances. Introduction Codes and ordinances fall under the broad description of laws Laws are written and adopted.
Should the Commissioners Adopt A Code Enforcement Program for Missoula County?
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
Residential Fire Sprinklers Building Codes Plan PreparationPlan Preparation The sprinkler contractor should be required to submit a set of complete, detailed.
Building Codes Violation of building codes and regulations can cause injury to building users and expose architects to legal liability and the possible.
Presentation on City of Westminster Water System Pressures May 1, 2013.
LAUSD INJURY AND ILLNESS PREVENTION PROGRAM FOR SUPERVISORS AND EMPLOYEES As required by California Code of Regulations, Title 8, Section 3203.
Massachusetts Department of Public Health Bureau of Environmental Health Heating Systems and Enforcement of the Housing Code (In conjunction with the Department.
1 Preparing for the California Residential Code! Residential Fire Sprinkler Criteria for One and Two-family Dwellings and Townhouses 2010 California Residential.
Residential Fire Sprinkler Systems. Goal Provide entry level firefighters with an understanding of residential fire sprinkler system Provide entry level.
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
Real Estate Principles and Practices Chapter 15 Property Management © 2014 OnCourse Learning.
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Water Supply.
Fresno County Fire Protection District. Fire Sprinklers Systems Residential – 13D October 30, 2007.
Technical Review Needed Fire Flow Analysis Developer Services Summit November 16, 2010 Engineering - Asset Planning Joe Dugandzic, PE.
Road Map to a Green Tag Paperwork=Time=Money. Questionnaire If you could change any one major thing inside the Fire Community Services process what would.
Implementing Rain Water Harvesting into Building Construction in VA Presented by: Guy Tomberlin, CBO Code Specialist III Fairfax County DPWES, Land Development.
NARUC Energy Regulatory Partnership Program The Georgian National Energy Regulatory Commission and The Vermont Public Service Board by Geoff Commons Vermont.

Commissioning of Fire Protection and Life Safety Systems Presented by: Charles Kilfoil Bechtel National Waste Treatment Plant Richland WA.
ESA Program Lead and Asbestos Safety Practices Presentation to the Low Income Oversight Board February 26, 2014 San Francisco, CA.
Chapter 10 Fire Prevention. Introduction One of the most important and least recognized jobs that the fire department performs is fire prevention Prevention.
Residential Fire Sprinkler Concerns. Water Supplier Reliability Issues Water Supply Water Facilities Water Quality Cost.
IRSDA Conference What Do the Amendments to Indiana Code Section Mean to You? Kristina Kern Wheeler, General Counsel Ja-Deen L. Johnson, Consumer.
15 Water Supply. 2 Objectives Describe the sources of water for a municipal water supply system. Explain the purpose of a water treatment facility. Describe.
Mayor’s Task Force On Adoption of 2006 I-Codes.  The following issues were discussed by Mayor DiTullio and Ken Johnstone on November 20, 2009 with Steve.
Workshop 2 – Administrative Structure Recycled Water Feasibility Study Rancho Murieta Community Services District January 8, 2008.
Building Permits for Solar Domestic Hot Water Systems Ted Van Vliet Toronto Building October 1 st, 2008 Presented at Solar Neighbourhoods Contractor Workshop.
Drinking Water + Compressed Air = Dangerous Mixture Spokane Regional Cross Connection Control Chapter Requirements for Winterizing Irrigation Systems with.
Code Officials and the Code Process.  To design the interior of the building in conjunction with codes, standards and federal regulations required in.
Advocating Residential Fire Sprinklers
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
Elementary School Administration and Management GADS 671 Section 55 and 56.
Real Estate Principles and Practices Chapter 15 Property Management © 2010 by South-Western, Cengage Learning.
C U S T O M E R D R I V E N. B U S I N E S S M I N D E D. Department of Licensing & Regulatory Affairs Bureau of Construction Codes Keith E. Lambert, P.S.,
Code Officials and the Code Process.  Concentrates on the code process as a whole.  Different type of code officials  Various steps that are taken.
NIOSH AND OSHA REGULATIONS AND CONTACT LENS USE BY: DR. MARK W. BURCHAM.
Sprinkler Loads on Trusses
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
Sprinkler Loads on Trusses Educational Presentation.
Chapter 3 Facility Design and Construction. Chapter Objectives 1.Describe the process of facility design and construction 2.Demonstrate proficiency in.
Inspection and Quality Assurance Requirements for Metal Plate Connected Wood Trusses Educational Overview.
Fundamental Concepts for Design of Special Hazard and Fire Alarm Systems Chapter 1.
Washington Surveying & Rating Bureau  Who Are We?  What Do We Do?  How Does Insurance Rating Promote Sprinkler System Installations and What Obstacles.
Process Safety Management Soft Skills Programme Nexus Alliance Ltd.
CITY OF HARARE EMERGENCY SERVICES
Cross Connection Survey Training
Your Public Water System’s Cross-Connection Control Program
City of Healdsburg Construction Codes Amendments & Adoption: 2016 Building Standard Codes Title 24 Parts 1 Thru International Property Maintenance.
Zurn Fire Valves - Overview 101
Land Use and Zoning Committee Special Workshop
Michigan Dept. of Environmental Quality Water Resources Division
Mayor’s Task Force On Adoption of 2006 I-Codes
County Wide Safety Program
DEVELOPMENT IMPACT FEES AB 1600 UPDATE
Presentation transcript:

Residential Fire Sprinkler symposium Ontario Convention Center

California Residential Code! 2 Residential Fire Sprinkler Criteria for One and Two-family Dwellings and Townhouses 2010 California Residential Code (Title 24, Part 2.5)

Identifying Common Issues and Solutions for Construction of Residential Fire Sprinklers A Best Practice Approach!!! 3 Identifying Common Issues and Solutions for Construction of Residential Fire Sprinklers

Symposium Outline Review the 2010 California Residential Code and the 2010 NFPA 13D (1 and 2 Family Dwellings and Manufactured Homes) and the amendments and/or modifications Develop an awareness of NFPA 13d Fire Sprinkler Systems, construction, components and function Identify laws and regulations concerning the use of water in California Develop an awareness of the CSFM Residential Fire Sprinkler Task Force Phase I Recommendations. Identify concerns for stakeholders of the new IRC fire sprinkler mandate Identify solutions and Best Practices that have alleviated the concerns of stakeholders of the new IRC fire sprinkler mandate 4

Classes Taught in California Prior to and after the adoption of 2010 California Residential Code (Title 24, Part 2.5) including CFPI and OSFM Enforcing Agencies (Fire) 216-Fire Agencies 3-UC Campus Agencies 16-CAL-FIRE - OSFM DSFM‘s 16-CAL-FIRE Contract Agencies 210-Agencies Total Enforcing Agencies (Building) 85-Building Agencies Enforcing Agencies (Water ) 31-Water Agencies/Purveyors Fire Protection Contractors 63-Fire Protection Contractors (C-16's) 12- Plumbing Contractors (C-36's) 3-Association Representatives 18-Supply & Manufacturers 66-Contractor/Suppliers Home Builders 21-Home Building Contractor (B) 3-Manufactured Home Contractor (C-47) 2-Home Builder Association 26- Home Building Contractors/Association Miscellaneous 52-Architects, Inspection Services, Engineers, Designers, Consultants, etc. Additional Presentations Sacramento AWWA Chapter San Diego Fire Protection Association Los Angeles SFPE Office of the State Fire Marshal California Fire Prevention Training and Education Institute

California Residential Code (Title 24, Part 2.5) California Building Standards Codes – 2007 CBC (based on 2006 IBC), CFC (based on 2006 IFC) – 2010 CBC (based on 2009 IBC) CFC (based on 2009 IFC) 6

California Residential Code (Title 24, Part 2.5) California Residential Code (CRC) – ICC-IRC, 2000 ed, 2003 ed, 2006 ed, & 2009 ed – 2010 CRC based on 2009 IRC – State Housing Law (Title 25) California Residential Code, Section R313 – 2009 ed. IRC Section P Table P (9) – 2010 ed. CRC Section R – NFPA 13D 2010 ed 7

California Residential Code (Title 24, Part 2.5) Defining New Buildings and Dwellings, Remodel, Renovations, Alterations (pg.24) Attached garages/carports (pg.22-23) – (NFPA 13D, Section 8.6.4) (pg.39) Property Setbacks (pg.21) Opening Protection (pg.22) Residential Care Facilities (pg.37) – R

California Residential Code (Title 24, Part 2.5) Matrix Adoption Table – Handout (Pg.41-45) NFPA 13D amendments – Handout (Pg.39 and 40) 9

Roles of the Stakeholders Why we needed to “Circle the Wagons?” Who we involved? What where the stakeholder roles as pertaining to the CRC? When we need to involve them? How we managed need and concerns? 10

Roles of the Stakeholders  Phase I Task Force Recommendation  Use the Best Practices Philosophy when applicable for making recommendations and suggestions for specific applications that are appropriate for the conditions within a specific region of California.  Defining Best Management Practices (BMP)  Refers to those practices that have produced outstanding results in another situation and that could be adapted for our situation. 11

Roles of the Stakeholders – BMP based on discipline Building Department Fire Department Water Purveyor Public Health Department Fire Protection Contractor Developer Homebuilder 12

13 STEEP Decision Model How will the issue stand in the current political climate How will the issue react to the environment? Affect on the stakeholder budgets? Technological Social How is the issue impacted by current technology? How does the issue impact Society? Economical Environmental Political No Improvement Improves life and safety Yes No Technology unavailable or not feasible Current technology available Yes No No funds available, issue too costly to consumer Funds available Yes No Issue has severe adverse impact No impact to environment Yes No Issue is a "NO WIN" Politically The issues has a positive political potential Yes No Decrease s life-safety Saves lives Yes No Out of reach, too much impact Costs in line with solution Yes No Adversely affects economy, project. Little impact to economy Yes No Issue adversely impacts the environment LEED Credits, Reduction to Carbon Imprint, Reduction in Landfill use Yes No No impact positively or negatively Issue is positive to local, private and business Yes No Residential Fire Sprinkler Water Task Force Issues (Fees, Process Efficiencies and Cost Impacts, Laws and Regulations, Connection Configurations) For each issue: Isolate your decision to “create the issue” Investigate the issue from all sides Refine the question regarding the issue What do we need to solve Positive or Negative Impacts Look at “key factors” STEEP Analysis Rehearse the Implications!

Terminology Communication is the number one cause of miscommunication – Identified as a Potential Recommendation for study in the Phase III IRC Task Force “Identify common terminology used by stakeholders in the water purveyor and fire industry for use in all aspects of NFPA 13D Residential Fire Sprinkler System construction and design. Phase III Final Report; Appendix E, Terminology (pg.48-51) 14

Residential 13-D Installations Statistics, Components, Construction, Results!

Residential Fire Statistics A home catches fire in the United States every 79 seconds. Tragically, on average, 82% of all fire deaths occur where most people feel the safest – in their home. In 2006 Alone: More than 396,000 home fires claimed the lives of more than 3,000 men, women and children An additional 13,825 were injured Property damage totaled more than $6,875,000,000

Smoke Alarms vs.. Sprinkler Protection Smoke Alarms Aren't Enough Smoke alarms are excellent at detecting smoke and alerting homeowners of a fire, and they should be installed in every home. However, only a fire sprinkler can control or even extinguish a fire. A recent study found that only 72-76%* of people wake up when a smoke alarm (60dBA) is sounded. The combination of working smoke alarms and home fire sprinklers, however, reduced the likelihood of death from a fire by more than 80%. One in four U.S. home fire fatalities occurred in homes with working smoke alarms. ** *US Fire Administration (National Fire Data Center Topical Fire Research Series, Volume 5- Issue 1, March 2005) **NFPA Fire Loss Data

Installing the Residential Fire Sprinkler System The system may be installed by a licensed contractor or an owner- builder per the CA. State Contractor License Board.

Tools to do the job! Cutting and Deburring Tools BlazeMaster® Calk & Walk™ Firestop One-step CPVC Cement and Daubers

System Components Riser – Flow Switch – Gauge – Test Valve

System Components CPVC Pipe or other approved material * copper * steel Hangers and Braces

Alternate Pipe Pipe may be copper, steel or other approved type.

System Components Exterior Bell – Alert occupants and neighbors when the water flow switch is activated

System Components Sprinkler Heads * Pendant * Side wall * Dome * Flat Plate

System Components Spare Head Box – usually near the riser when required

System Components Residential Domestic Shut-off valve. Makes water available on demand to the domestic system, and acts as a check valve for the fire protection system. When the sprinkler system operates in the home, the supply to the domestic system is automatically shut off and makes the maximum use of the available water supply to control the fire. 1" domestic shut-off valves are used in piping systems that supply water to both the domestic service and the fire sprinkler designed per NFPA 13D in one and two family dwellings or mobile homes.

Multi-purpose Systems

NFPA 13-D Construction Riser Installation – Connects the domestic water supply to the Fire Sprinkler System Brass or Steel pipe, CPVC Pipe and fittings, Flow Switch, Gauge

Riser Concealed in Wall Similar Components – Note the pressure reduction valve

Typical Gauge installation Gauge notes the static and residual pressure of the system. Allows the occupant to note that the system is pressurized

Installation of the Fire Sprinkler System Typical attic installation CPVC Pipe is the typical pipe used in most installations – tee at the top of the riser

Typical End of Line Location for future sprinkler head – elbow – Cap to protect the fitting and threads

In-line and End of Line Construction Note the Tees in line with the pipe Also note the end of line

Ceiling Joist Installation Capped for future addition Note the Brace

Rough In Inspection Rough in Inspection – Visual inspection system installed per approved plan – Pressure Test insure that fittings are glued properly

Finished Product Note the flat plates

Final Inspection of the Finished Product Walk the system to make sure it is installed correctly, aesthetically Operate Flow Switch to test the bell and make sure the system is pressurized.

How do Residential Sprinklers Work? * A single residential sprinkler can protect a room area up to 20’ X 20’ – with an average house requiring only sprinklers *Each sprinkler protects the area below it. Only a threatening fire can generate enough heat to activate a a sprinkler – typically at 155°F. *Only the sprinkler closest to the fire will activate, spraying water directly on the fire and the area that the sprinkler has been designed to protect. *Sprinklers can control or even extinguish the fire before it can build deadly heat and smoke so you and your family can escape safely, and limit damage to your home. *Your sprinkler system can be linked to the local fire company or home alarm system so that they are immediately notified when a sprinkler activates.

The Results of a Residential Fire Sprinkler System In less time than it would take a fire department to arrive on the scene, a single sprinkler can control or even extinguish the fire.

Final Inspection and Acceptance Testing Rough Overhead Water flow and Pressure Final Inspection

Maintenance The responsibility for maintenance of the system lies with the owner Recommendations for monthly maintenance are contained in the standard (inspections of system components, testing of alarms, pumps & other system components, etc.) Available Resources (

Summary Statistics Show that Sprinklers save lives Systems are economical and easily installed Systems are easily inspected and maintained

Statutory Authority (Statutes and Regulations) Health and Safety Code Government Code Business and Professions Code Contractors State License Board State Water Board State Housing Laws Title 25 California Public Utilities Commission State Public Safety Title 19 43

Statutory Authority (Statutes and Regulations) General Questions and Answers: (pg.52-56) 1. Where is it written that public commissions, boards and councils and other public agencies must conduct their business/actions in an open forum/hearing? – Answer: Ralph M. Brown Act – (Government Code Section ) 2. Where does it require that a state body (Agency, Board, Advisory Committee, etc.) must provide notice at least 10- days prior to a public meetings in which action shall be taken? Answer: Bagley-Keene Open Meeting Act – (Government Code Section ) 44

Statutory Authority (Statutes and Regulations) 3. Are there any regulations which define criteria by which a water purveyor can discontinue the water service to a customer for non-payment? (Note: This regulation only applies to water purveyors who fall under the authority and jurisdiction of the CA Public Utilities Commission – PUC.) – Answer: General Order No. 103: – (CA Public Utility Commission – Water Branch, Section I-6.a thru f) 4. Where can I find the statutory authority for the California Safe Drinking Water Act, and what does it say? – Answer: California Safe Drinking Water Act: (Health and Safety Code, Section ) 45

Statutory Authority (Statutes and Regulations) 5.Where does it define the requirements for Backflow/Cross-Connection devices on a water service?  Answer: Backflow/Cross-Connection  (Health and Safety Code, Section ) 6.Is there any state law which governs the implementation of backflow/cross-connection equipment and/or device(s) when connecting a residential fire sprinkler system to the domestic water supply service?  Answer: Backflow Prevention and Cross- Connection Control  (Health and Safety Code, Section and ) 46

Statutory Authority (Statutes and Regulations) 7. What is the statutory authority for a local agency to impose fees and charges for a water service connection? – Answer: Service Connection Fees/Charges: – (Government Code Section 66013) 8. Where is the statutory criteria found for a local agency (Planning, Building and/or Fire) for establishing fees and charges associated with processing and inspecting projects? – Answer: Building/Fire Agencies: – (Government Code Section 66014) 47

Statutory Authority (Statutes and Regulations) 9. If the Building Department wanted to do the review and inspections of residential fire sprinkler systems and the Fire Department objected; “Do we, the Fire Department have the authority to keep this task?” – Answer: The city, county, or city and county shall delegate. – (Health & Safety Code, Section ) 48

Statutory Authority (Statutes and Regulations) 10. By code we cannot require five year services on residential fire sprinkler systems. Can this be accomplished by local ordinance? – Answer: NO – (CA SFM Website: Question taken from Frequently Asked Questions Concerning NFPA-25, 2006 California Edition [Page #7]: Can local fire authorities adopt testing and maintenance requirements that are more restrictive than the service requirements in the California Code of Regulations, Title-19? Answer: No. ) – (Health & Safety Code, Section , , ) 49

Statutory Authority (Statutes and Regulations) 11. Can a Fire Protection Contractor (C-16) design the system that he or she is to install? – Answer: YES – (B&P Code – Contractors License Law ) 12. What does Section R313 of the 2010 California Residential Code say as relates to the design and installation of a residential fire sprinkler systems? Answer: See Section R – (R Design and installation. Automatic residential fire sprinkler systems for townhouses shall be designed and installed in accordance with R313.3 or NFPA 13D.) 50

Statutory Authority (Statutes and Regulations) 13. Is it the intent of Section R313 to allow residential fire protection systems to be installed by a Fire Protection Contractor (C-16) and/or a Plumbing Contractor (C-36)? – Note: Section R General states “Where installed, residential fire sprinkler systems, or portions thereof, shall be in accordance with NFPA-13D or Section R313, which shall be considered equivalent to NFPA-13D.” So, does all of this mean if you are a C-16 you design and install in accordance with NFPA-13D and if you are a C-36 you design and install in accordance with R313? – Answer: Only Fire Protection Contractors (C-16’s, General Manufactured Housing Contractors (C-47’s) and Owner-Occupied Owner-Builders may install a fire protection system. – (B&P Code – Contractors License Law, Sections (a), , , ) (B&P Code 7008, 7058, and 7059) ( Class C-47 – General Manufactured Housing Contractor) 51

Statutory Authority (Statutes and Regulations) 14. Why doesn’t the State of California do like many other states and mandate that all fire sprinkler designs will be done by or supervised and certified by a minimum NICET – Level III Automatic Sprinkler Layout Technician? – Answer: In California, the State of California licenses Professional Engineers (BPE&LS) for design of systems and Contractors (CSLB) for design and installation of fire protection systems. A quick check of the licensing requirements and/or application forms for both the Board of Professional Engineers & Land Surveyors (BPE&LS) and the Contractors State License Board (CSLB) are silent when it comes to NICET criteria necessary to be licensed as an engineer and/or contractor. – Note: Many states have this requirement in order to even get a Fire Protection Contractor license. 52

Statutory Authority (Statutes and Regulations) 15. How does the State handle training and education for contractors, installers, plan checkers, inspectors, and the consumer? – a) Contractor/Installers: Answer: Necessary degree of knowledge (B&P Code – Contractors License Law Section 7065, 7068) – b) Plans Examiner/Inspectors (Fire): Answer: SFM shall establish fire prevention training for delivery on a regional basis. (Health & Safety Code, Section ) – c) Plans Examiner/Inspectors (Building): CA. Building Standards Law Health and Safety Code – d) Consumer: Answers:(Health & Safety Code, Section 13144) 53

Statutory Authority (Statutes and Regulations) 16. In a multi-purpose system, will the traces of lead in the sprinkler heads be a problem with the domestic water? – Answers: Sprinklers and other components must be “lead free” (meaning not more than 0.2 percent and not more than a weighted average of 0.25 percent when used with respect to the wetted surfaces of pipes and pipe fittings, plumbing fittings and fixtures. Manufacturer’s Data Sheets (Cut- sheets) now list compliance for California and Vermont. – (Health & Safety Code, Section ) – (Health & Safety Code, Section ) 17. What are the requirements for protecting attached garages in accordance with the 2010 California Residential Code? – Answer R302.6, R302.5, R

Statutory Authority (Statutes and Regulations) 18. What is the criteria which defines an “Underground Regulation” and is used for the premise by which State Agencies are required to follow strict criteria for the adoption of Building Standards? – Answer: Regulations SHALL be adopted by the Building Standards Commission or Office of Administrative Law. (Government Code, Section ) (Government Code, Section ) (Government Code, Section 1135) 19. Do Building Departments (and Fire Departments) need to maintain an official copy of the construction plans (including fire sprinkler drawings and calculations) for a single- or multiple dwelling for the life of the building? – Answer: No. (Health & Safety Code, Section 19850) 55

Training Resources  American Fire Sprinkler Association  National Fire Sprinkler Association  National Fire Protection Association  Sprinkler Fitters of California  Society of Fire Protection Engineers  International Code Council  California Building Officials (CALBO)  California Fire Prevention Officers Association  League of California Cities American  Water Works Association  Building Industry Association (BIA)  Home Builder Association (HBA) 56

Training Venues/Hosts (Stakeholders) Homeowners/Real Estate Agencies/Insurance Agencies – Homeowners Maintenance Awareness – Real Estate Agencies Life Safety (Built-in Fire Protection) – Insurance Agencies Insurance Credits (5-15%) 57

Office of the State fire Marshal Phase I Task Force Recommendations Best Practice Recommendations Final Report

Best Management Practices FEE SUB-GROUP PHASE I Use the Best Practices Philosophy when applicable for making recommendations and suggestions for specific applications that are appropriate for the conditions within a specific region of California.

Best Management Practices FEE SUB-GROUP PHASE I Eliminate as a best practice and in accordance with NFPA 13-D, the combination of the domestic and fire sprinkler flows when calculating flows for service sizes. NFPA’s intent is to reduce the flow requirement and allows meter service sizing accordingly. Statistically, sprinklers and largest demand will not activate at the same time.

Best Management Practices FEE SUB-GROUP PHASE I Develop a Best Practice Philosophy/Program for the State of California for determining fees for technology, maintenance, inspection, service and monthly standby or utility fees for use in billing consumers with residences that are constructed with NFPA 13-D Residential Fire Sprinkler Systems.

Best Management Practices FEE SUB-GROUP PHASE I Encourage the use of flow-through designs as a best practice, to minimize the need for backflow prevention. Support a detailed and thorough study of the risk and benefit of backflow prevention through an industry study.

Best Management Practices FEE SUB-GROUP PHASE I Recommend a statewide best practice for calculating fees for plan review by enforcing agencies of NFPA 13-D Residential Fire Sprinkler systems. Moved to the Phase II Task force as a item for additional study.

Best Management Practices Connection Configuration Sub-group Recommends a configuration with the following characteristics: – Single lateral feed from main; branching from the domestic supply to the meter. Least cost, simplest design, provides greatest flexibility. – Service sized based upon sprinkler demand and/or domestic (including irrigation) demand – worst case, without concern for simultaneous demand. Issues of designing to minimize simultaneous demand by requiring private domestic shutoff valve complicates household design but it is an option open to the individual agency. 1 ‑ inch meters are generally acceptable if based on these criteria.

Best Management Practices Connection Configuration Sub-group Service lockout as per agency policy. Shutoff ability is required by the water purveyors for a variety of reasons. Agencies should use best practice to word shutoff notices to include potential loss of fire sprinkler protection and take appropriate measures to limit potential liability associated with discontinuing fire protection service. (Consider alternate design and possible hold harmless clause as part of Phase II discussion.) Metering per purveyor/agency policy (and commonly by guiding practices or statutes) with exemption from fire rating for residential application. Include maximum flexibility in the service configuration, which allows agencies to use existing policies, procedures and time-tested material resulting in appropriate cost for long-term reliability.

Best Management Practices Connection Configuration Sub-group Continue the water industry standard that facility costs are 100 percent captured in the fees directly associated with installation, maintenance, reading, and replacement of the meters. Monthly billing prices should have clear nexus to both the fixed and variable cost of service provided and should remain a local purveyor policy issue. Include a design that allows for connection of the fire protection system to remote fixtures to insure flushing of the system as a result of typical and frequent use. This will allow consideration of elimination of a backflow device by insuring water remains flushed.

Best Management Practices Connection Configuration Sub-group Recommendations for type/listing of meter; meter size/arrangement; meter versus no meter. Selection of particular meter and configuration to be in keeping with agency’s policies and engineering requirements based on demand flows.

Best Management Practices Phase I General Recommendations Recommendations for rural versus municipal supply. Current technology is available though water supply capability may be quite different. Municipal is likely more reliable in terms of supply owing to larger base of resources to operate and maintain the system. No difference in configuration, but supply facilities may be affected, e.g., onsite storage tank or large well flowing to the sprinkler flow if additive. Flexibility of configuration supports minimizing use of materials in construction.

Best Management Practices General Recommendations Recommendations for backflow protection. Optional backflow does not provide 100 percent guarantee of backflow protection, however, protection is in keeping with current level of overall protection. By providing both Best Management Practices and local flexibility, political support is maintained.

Best Management Practices General Recommendations Recommendations for water supply criteria – pressure/flow/duration. Ensuring a coordinated approach to purveyor supply, configuration, and cost with other regulatory agencies (State and fire agencies) for an adequate water supply is in the best interest of the citizens.

Best Management Practices CONNECTION CONFIGURATION SUB-GROUP Recommendations for consistency Although configurations may not be consistent from jurisdiction-to-jurisdiction, configurations would be flexible to situations and circumstances throughout the State of California.

AFTERNOON SESSION Connection Configurations and Best Practice Solutions

Residential Fire Sprinkler Concerns A Water Purveyors Perspective Presented to NCBPA Bill Kirkpatrick, Engineering Manager

Water Supplier Reliability Issues Water Supply Water Facilities Water Quality Cost

Exchange oF Ideas Demonstrations, sharing of Best Practices