Dry type transformers Zaragoza Drives application

Slides:



Advertisements
Similar presentations
“Power Factor” In Transmission System
Advertisements

POWER FACTOR IN ELECTRICAL ENERGY MANAGEMENT
Copyright© Voltimum Experts – not to be reproduced without prior consent of Voltimum UK Voltimum Expert Topic – Power Harmonics.
1 POWER QUALITY -- Bhanu Bhushan -- June, How close is the supply voltage waveform to sinusoidal, and how close are the supply voltage and frequency.
Chapter 12 Transformers. Chapter 12 Transformers.
QUALITY AND TECHNOLOGY
Siemens Building Technologies Building Technologies Variable Frequency Drives Harmonics Overview.
ENERGY CONVERSION ONE (Course 25741)
EMC in Electrical Power Systems Frithiof Jensen Power System Engineer November 12, 2013.
Lesson 38 Shipboard Power
2010 ASHRAE Rocky Mountain Chapter VFD Fundamentals April 16, 2010 Jeff Miller - ABB © ABB Month DD, YYYY | Slide 1 1.
VARIABLE SPEED DRIVES AND FILTERS CLASSIFICATION AND APPLICATION.
EXPERIMENTAL STUDY AND COMPARATIVE ANALYSIS OF TRANSFORMER HARMONIC BEHAVIOUR UNDER LINEAR AND NONLINEAR LOAD CONDITIONS.
ISSBN, Electronic faculty of Niš, November Use of distortion power for side identification of the harmonic polution Dejan Stevanović, Electronic.
Alternating Current Circuits
Dry type transformers Zaragoza Traction application
Today’s Topics 1- The per unit system 2-Transformer Voltage Regulation
Power Engineering Society Chicago Chapter Reactive Power: Sources and Solutions 12 February 2003 David E. Mertz, PE Burns & McDonnell Engineers, Inc.
Transformers and Coupled Circuits
electronics fundamentals
Power Factor and Power Factor Correction
Dry type transformers Zaragoza Accessories and options
PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
Dry type transformers Zaragoza hi-T Plus
Unit 29 Three-Phase Transformers. Objectives: Discuss the construction of three-phase transformers. Discuss the formation of a three-phase transformer.
Introduction to Electrical Machines
Main article: Leakage inductance
CHAPTER 6: TRANSFORMER BAKISS HIYANA ABU BAKAR
Chapter 2 Transformers.
Transformers Mechanical and Electrical Systems SKAA 2032
ET3380 Principles and Methods of Electric Power Conversion David Morrisson MS,MBA Week 1.
POWER FACTOR CORRECTION
Transient Overvoltages
PQSynergy TM 2011 Harmonic Assessment of PEA North1, Chiangmai’s Customers in North Industrial Estate Chotepong Pongsriwat. M.Eng(EE) Chief of Power.
7154 VFD Presentation #2 May 2002 Paul Weingartner.
Motors Product Line NEMA Premium® is a trademark of NEMA.
1.6 Real Single-Phase Transformer.
POWER QUALITY.
Voltimum Expert Topic – Power Harmonics. What are Harmonics? They are waveforms with frequencies that are multiples of the fundamental frequency (Typically.
1 POWER QUALITY -- Bhanu Bhushan -- April, Simple examples around us : Ceiling fan regulators Tube lights Lap-tops & peripherals Domestic inverters.
A Presentation On Construction Of Turbo Generator
1 ELECTRICAL TECHNOLOGY EET 103/4 Define and analyze the principle of transformer, its parameters and structure. Describe and analyze Ideal transformer,
A Presentation on construction of Turbo Generator.
1 ELECTRICAL TECHNOLOGY EET 103/4 Define and analyze the principle of transformer, its parameters and structure. Describe and analyze Ideal transformer,
UNIT – II ELECTRICAL MACHINES.
Transformers and Impedance. Review Two types of current: –ac –dc Two fundamental principles: –Moving electrons create magnetic fields –Moving or changing.
CLOSED LOOP SPEED CONTROL OF DC MOTOR WITH PWM TECHNIQUE
DC Machine & Transformer
1 ELECTRICAL TECHNOLOGY ERT 105/3 Define and analyze the principle of transformer, its parameters and structure. Describe and analyze Ideal transformer,
Review of ABB Drives. 1.Direct torque control explains what DTC is; why and how it has evolved; the basic theory behind its success; and the features.
HNC/D Engineering Science
Equations, Performance, Electrical Equivalent Circuits
From Lecture1 vi , ii vo , io Power Processor Controller Source Load
CHAPTER 4 SINGLE-PHASE TRANSFORMER
Effects of Harmonics on Capacitors Electrical System
Sensor presentation.
A Project Review On POWER QUALITY IMPROVEMENT IN GRID USING STATECOM
CHAPTER 6 SPECIAL TRANSFORMERS Electrical Machines.
HARMONIC MITIGATION USING PASSIVE FILTERS
Yaskawa Electric America on Variable Torque Loads
Power System Harmonics
Electrical Machine-I EE 2107 Dr. Md. Sherajul Islam
Electromechanical Systems
Energy Conversion and Transport George G. Karady & Keith Holbert
ECE 333 Green Energy Systems
מנועים חשמליים המרת אנרגיה והינע TO THE TRAINER
SHUNT ACTIVE FILTER It is a voltage-source converter connected in shunt with the same ac line and acts as a current source to cancel current distortions,
Equations, Performance, Electrical Equivalent Circuits
INVERTERS. What is an Inverter? A static device that converts DC power into AC power at desired output voltage and frequency is called an Inverter. Applications.
Presentation transcript:

Dry type transformers Zaragoza Drives application © ABB Group 2009 | Slide 1

Index Variable speed drives Specialized transformer Effects of harmonics in transformers Special design Examples © ABB Group 2009 | Slide 2

Variable speed drives I ABB is the world’s leading supplier of AC drive products and systems for industrial use, commercial and residential applications, improving manageability, efficiency and energy economical processes. © ABB Group 2009 | Slide 3

Variable speed drives II Drives applications Cement Mining and Minerals Power Generation Petrochemical Metals Pulp and Paper Water Plants Marine Oil and Gas And many more… © ABB Group 2009 | Slide 4

Variable speed drives III ABB standard solutions ABB AC Drives know-how, experience of industrial and utility applications and flexibility to build complete packages according to customer needs. Deep cooperation between ABB divisions by achieving standard added value solutions: Simplifies equipment supply process, installation and commission. Shorter delivery time. Benefits to end users. Assures successful function of whole package. Customer feels safe in ABB hands © ABB Group 2009 | Slide 5

Variable speed drives IV ABB variable speed drives Devices used to vary the speed of AC Motors ABB has the most comprehensive drive family in the market with the most advanced and proven technology available. AC drives can be connected to most rotating machines, which in turn, improve process control flexibility, accuracy, productivity, reliability and energy efficiency. AC Drives is a product family with a wide selection of products and high technology, suited for several application areas: pumps, fans, compressors, conveyors, mills, thrusters, drilling packages, gas turbines, extruders, mixers, propulsion, hoist. © ABB Group 2009 | Slide 6

Variable speed drives V ACS 800 (high and low harmonic content) Vacuum cast coil transformer characteristics: Manufactured according to IEC 60076-11, IEC 60146-1-3, IEC 61378-1 Two and three winding transformers. 30º shift for 12-pulse operation (three-winding transformers). Maximum symmetry must be guaranteed between the secondary windings. Electrostatic screen between primary and secondary windings. Transformers designed to withstand the harmonic content of the network. © ABB Group 2009 | Slide 7

Variable speed drives VI ACS 1000 Vacuum cast coil transformer characteristics: Manufactured according to IEC 60076-11, IEC 60146-1-3, IEC 61378-1 Three-winding, dry type transformer. Electrostatic screen between primary and secondary windings. Secondary windings designed and tested with a superior insulation level. Maximum symmetry guaranteed between secondary windings. Cross divisional cooperation within ABB in order to design the optimum transformers for the ACS1000 application. Example of common mode voltage wave form, measured on the secondary side phase to ground. © ABB Group 2009 | Slide 8

Variable speed drives VII ACS 1000i Electrostatic screen between primary and secondary windings. Secondary windings designed and tested with a superior insulation level. Maximum symmetry guaranteed between secondary windings. Cross divisional cooperation within ABB, in order to design the optimum transformers for the ACS1000 application. Vacuum cast coil transformer characteristics: Manufactured according to IEC 60076-11, IEC 60146-1-3, IEC 61378-1. Five-winding, dry type transformers to operate with a 24 pulses generator integrated in ACS 1000 drive. 24 pulses vacuum cast coil Transformer for an ACS1000i Drive © ABB Group 2009 | Slide 9

Variable speed drives VIII ACS 5000 Vacuum cast coil transformer characteristics: Manufactured according to IEC 60076-11, IEC 60146-1-3, IEC 61378-1. 2 x four windings dry type transformers, to operate with a 36 pulse generator. Electrostatic screen between primary and secondary windings. Secondary windings designed and tested with a superior insulation level. Maximum symmetry guaranteed between secondary windings. © ABB Group 2009 | Slide 10

Variable speed drives IX ACS 6000 Vacuum cast coil transformer characteristics: Manufactured according to IEC 60076-11, IEC 60146-1-3, IEC 61378-1. Options: 6-pulse: two windings dry type transformer. Casted secondary windings. 12-pulse: 2 x two windings dry type transformers. Casted secondary windings. 18-pulse: 3 x two windings serial connected dry type transformers. Casted secondary windings. Additionally transformers for the ACS6000 ARU are designed and tested with a superior insulation level. © ABB Group 2009 | Slide 11

Transformers for drives Applications These transformers for VSD are used in several applications such as: Traction Propulsion Rectification Excitation © ABB Group 2009 | Slide 12

Specialized transformers Non-standard transformers Transformers for variable speed drives, are non standard transformers due to the distortion created by harmonics: Harmonics from rectifiers. Overvoltages during transients. Due to these factors, this transformer type requires a special design. © ABB Group 2009 | Slide 13

Effects of harmonics in transformers I Harmonics are distortions of the mains supply occurring at multiples of the supply frequency. Any equipment which uses electronics to change one voltage and / or frequency to another will generate harmonic currents and consequently voltage distortion. © ABB Group 2009 | Slide 14

Effects of harmonics in transformers II Source of current harmonics Switching the line current with line frequency or its multiple by means of electronic switches. No-linear impedance. Current dependant resistances: Arc furnaces, welding machines, fluorescent lamps… Voltage dependant inductance: Transformers and core reactors. Switching on saturable inductance as induction motors or transformers. Non linear load generate harmonics © ABB Group 2009 | Slide 15

Effects of harmonics in transformers III Effects of voltage harmonics. Increase of no load losses. Increase of noise level. Generated voltage shape is not fully sinusoidal. Effects of current harmonics. Increase of load losses. Local overheating due to uneven distribution of the eddy losses. Eventually resonance over voltages. © ABB Group 2009 | Slide 16

Effects of harmonics in transformers IV Evaluation of harmonic content Total harmonic distortion factor: The quotient of the r.m.s. value of the sum of all the harmonic components up to a specific order and the r.m.s. value of the fundamental component: The limitation of THD is aimed to prevent the simultaneous presence of several harmonics components with high amplitude. å ÷ ø ö ç è æ = H h Q THD 2 1 © ABB Group 2009 | Slide 17

Effects of harmonics in transformers V Compatibility levels for voltage harmonics. According to IEC 61000-2-4 for class 3 environments: THD  10% There are also limitations for individual value: Odd order excluding multiple of three (3,9,15…). Even order. Odd order multiple of three. Inter harmonics. © ABB Group 2009 | Slide 18

Special design I Due to the flow of harmonic currents in both Low voltage and high voltage windings, there are extra losses and extra heating, thus the transformer must be over rated according to a higher equivalent power. Due to the flow of harmonic currents through the network and transformer impedance, there is a voltage distortion (voltage harmonics) on the transformer magnetic core, which could saturate. To avoid core saturation, the magnetic core must be over sized. © ABB Group 2009 | Slide 19

Special design II In order to avoid capacitate coupling between high voltage and low voltage and to protect the power electronics devices on low voltage side from over voltages in HV side, it is recommended to place an electrostatic shield between high voltage and low voltage windings. In some cases (i.e. ACS1000), due to floating systems or high du/dt, higher insulation levels on low voltage windings are needed. © ABB Group 2009 | Slide 20

Special design III In case of three or more winding transformers the following points must be considered: The low voltage winding placed at top position must be over rated because of its worse cooling (hot cooling air coming from the bottom low voltage winding). © ABB Group 2009 | Slide 21

Special design IV The number of turns of low voltage windings must be modified in order to reach the voltage ratio between these two low voltage windings. The impedance between low voltage windings must be matched by calculating and manufacturing carefully the windings dimensions. The space factor is more critical because of the insulation gap between windings, and the larger size of the transformer. In order to guarantee the correct losses and good operation, the high voltage winding is split in two or more parallel circuits with two o more tap changers instead of one circuit. © ABB Group 2009 | Slide 22

Examples ACS1000Air ACS1000Water ACS5000Air ACS5000Water © ABB Group 2009 | Slide 23

Dry type vacuum cast coil Dry type transformers serving drives for customer satisfaction. © ABB Group 2009 | Slide 24

© ABB Group 2009 | Slide 25