Measuring Kinetics of Luminescence with TDS 744 oscilloscope

Slides:



Advertisements
Similar presentations
Optical sources Lecture 5.
Advertisements

Photoelectrochemistry (ch. 18)
Measuring the Speed of Light Jack Young Rich Breazeale Ryan Phelan.
X-rays & LASERs Section 31-7 Physics 1161: Lecture 24.
Molecular Fluorescence Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Measuring the Speed of Light! Photonic partners: David Orenstein Anuta Bezryadina Nathan Burd.
Light Amplification by Stimulated
Lecture 3 Kinetics of electronically excited states
Luminescence (Miklós Nyitrai; 27 th of February, 2007)
Short pulses in optical microscopy Ivan Scheblykin, Chemical Physics, LU Outline: Introduction to traditional optical microscopy based on single photon.
EM Radiation Sources 1. Fundamentals of EM Radiation 2. Light Sources
Phys 102 – Lecture 25 The quantum mechanical model of light.
Introduction to the Oscilloscope
Some quantum properties of light Blackbody radiation to lasers.
EM Radiation Sources 1. Fundamentals of EM Radiation 2. Light Sources 3. Lasers.
Atomic Absorption Spectroscopy (AAS)
Optical Pumping Intense light source at h  (e.g. flash lamp) Excites to a metastable state to achieve population inversion With fast flashing, initial.
The Oscilloscope: Basic Features & Functions  Source –Determines which signal is compared to the trigger settings.  Level –Determines where on the edge.
Chapter 15 Molecular Luminescence Spectrometry Molecular Fluorescence  Optical emission from molecules that have been excited to higher energy levels.
Electric Curcuits and Measurements Basic Electrical components and their functions Measurements of electrical circuits characteristics - Multimeter - Oscilloscope.
Electron Paramagnetic Resonance spectrometer
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
Chem. 133 – 3/12 Lecture. Announcements I HW 2.1 problem due today Quiz 3 also today Lab – Term Project Proposal due next Thursday Sign Up (see details.
Common types of spectroscopy
Illumination and Filters Foundations of Microscopy Series Amanda Combs Advanced Instrumentation and Physics.
Atomic Emission Spectroscopy
5 Components Common to All Optical Spectrometers Source Transparent Sample Holder Wavelength Selector Radiation Detector Signal Processor and Readout.
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze: Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS Detection.
An Introduction. The first step on the road to laser was the publication of paper by Albert Einstein in 1916 –describing how atoms could interact with.
RamanRaman. Scattering Tyndall scattering – if small particles are present During Rayleigh scattering (interaction of light with relatively small molecules)
The contribution from The contribution from photoluminescence (PL) Gordon Davies, King’s College London.
Observation of Excited Biexciton States in CuCl Quantum Dots : Control of the Quantum Dot Energy by a Photon Itoh Lab. Hiroaki SAWADA Michio IKEZAWA and.
B.SC.II PAPER-B (OPTICS and LASERS)
Fluorometric determination of riboflavin
Optical Characterization methods Rayleigh scattering Raman scattering transmission photoluminescence excitation photons At a glance  Transmission: “untouched”
Fluorometric determination of riboflavin. Introduction.
Fluorometric Analysis
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 19 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS.
Chapter 15 Molecular Luminescence Spectrometry Three types of Luminescence methods are: (i) molecular fluorescence (ii) phosphorescence (iii) chemiluminescence.
Fluorescence Spectroscopy
Chapter 6 An Introduction to Spectrometric Methods Spectrometric methods are a large group of analytical methods that are based on atomic and molecular.
Photoluminescence and Photocurrent in a Blue LED Ben Stroup & Timothy Gfroerer, Davidson College, Davidson, NC Yong Zhang, University of North Carolina.
CLS 332 CLINICAL INSTRUMENTAL ANALYSIS. A VISIBLE ABSORPTION SPECTROMETER.
Optoelectronics.
Molecular Luminescence Spectroscopy
Scope TEKTRONIX TDS. Frontal View Menu and Control Buttons Multipurpose knob.
Fluorometric determination of riboflavin
Development of a Fluorescence Excitation Spectroscopy System Michael McDonnell ▪ Stephen Drucker Department of Chemistry ▪ University of Wisconsin – Eau.
Laserlaser. Laser printer Laser pointer Laser: everywhere in your life.
Molecular Fluorescence Spectroscopy
Lab1 A VISIBLE ABSORPTION SPECTROMETER
Flame Emission Spectrometry
Chem. 133 – 3/14 Lecture.
Ultrafast Spectroscopy
Transient Absorption (Courtesy of Kenneth Hanson, Florida University): The technique applied to molecular dynamics Source hn Sample Detector.
Light Amplification by Stimulated
Really Basic Optics Instrument Sample Sample Prep Instrument Out put
Well - come.
Practical Absorbance and Fluorescence Spectroscopy
Measuring the Speed of Light!
Scintillation Counter
SPECTROPHOTOMETRY Applied Chemistry.
Photon Physics ‘08/’09 Thijs Besseling
Molecular Luminescence Spectrometry
Phase shifted and cascaded long-period fiber grating written by using focused high-repetition-rate CO2 laser pulses.
TIME RESOLVED SPECTROSCOPY [T.R.S.]:
Fluorescence of Samarium Ions in Strontium Bismuth Borate Glasses
Fluorescence of Samarium Ions in Strontium Bismuth Borate Glasses
Presentation transcript:

Measuring Kinetics of Luminescence with TDS 744 oscilloscope Nex Eex Luminescence Photon E0

Disclaimer Safety –the first !!! This presentation is not manual. It is just brief set of rule to remind procedure for simple measurements. You should read manual first. Notwithstanding any language to the contrary, nothing contained herein constitutes, nor is intended to constitute, an offer, inducement, promise, or contract of any kind. The data contained herein are for informational purposes only and are not represented to be error free. Any links to non-UAB information are provided as a courtesy. They are not intended to constitute, nor do they constitute, an endorsement of the linked materials by the University of Alabama at Birmingham.

Luminescence is a process in which a excited material emits light (electromagnetic radiation) For example, the following types of luminescence caused by different excitation process could be classify : Chemoluminescence, is the emission of light as the result of a chemical reaction Light production in fireflies is due to a type of chemical reaction called bioluminescence Photoluminescence ( PL) is a process in which a material absorbs photons (electromagnetic radiation) and then re-radiates photons Banknote photoluminescence after excitation by UV light from flash lamp Electroluminescence (EL) is an process in which a material emits light in response to an electric current passed through it, or to a strong electric field. Infrared electroluminescence of photodiode in the remote stimulated by electrical current

Parameters of the Luminescence Luminescence spectra shows how intensity of the luminescence depends on wavelength Luminescence lifetime refers to the average time the molecule/ion stays in its excited state before emitting a photon (or how long luminescence could be observed) The luminescence quantum yield gives the efficiency of the luminescence. It is defined as the ratio of the number of photons emitted to the number of photons absorbed. Goal of the Lab: Measuring of the kinetics of the photoluminescence signal and luminescence lifetime

Decay kinetics of the Luminescence Energy Nex Eex Excitation Photon Luminescence Photon E0 Ion Excitation: Absorption of the excitation photon result in transition of the molecule/ion from the ground state (E0) to the excite state (Eex) and create population at higher energy state (Nex) Relaxation: Followed relaxation of the molecule/ion to the ground state could result either emission luminescence photon or energy transfer to the crystal (heating the crystal ) Intensity of the Luminescence (ILum) typically follows exponential decay law (where parameter  is excited-state lifetime)

Basic Components of the experimental setup First of all, for photoluminescence measurements we need source of the optical pulses for excitation our sample (usually it is pulse laser) 2. We need optical collimator to collect maximum of the emitted photons and to direct luminescence to the detector (usually it is single lens or lens system ) 3. Next we need optical selective system to block optical excitation pulses and measure only selective luminescence (usually it is optical selective filter or spectrometer) 4. Detector is a type of sensor capable of converting light into either current or voltage 5. Electrical signal from the detector (+amplifier) is measured by oscilloscope

Experimental setup Sample Optical Excitation source Optical collimator system Oscilloscope Optical selective system Detector + Amplifier Detected signal Triggering signal

Requirements to optical excitation First of all, a wavelength of the optical excitation pulses should be within absorption band of the studied samples Second, excitation pulse duration should be shorter than studied kinetics of luminescence. Otherwise, measurements will demonstrate excitation-pulse temporal-profile. Available commercial tunable solid-state lasers 30ps 7ns 60-100ns Typical curve of the Alexandrite laser OPO Ekspla OPO Spectra Physics

Requirements to detector Detection spectral range: Detector should be sensitive in the spectral range of the luminescence Operating Ranges for ARC detectors 2. Respond time : Detector (+Amplifier) respond time should be shorter than studied kinetics of luminescence

Oscilloscope Overview Vertical control (sensitivity, V) Horizontal control (time, sec) Select Channel On/Off Button Channel inputs

Oscilloscope triggering To measure kinetic of the Luminescence you need to trigger oscilloscope when optical pulse hit the sample. Trigger determine when the oscilloscope starts acquiring and displaying a waveform. Trigger signal could be either electrical logic signal from the pump-laser power-supply or electrical signal from the external photodiode detecting pump optical pulse .You could connect any of four oscilloscope inputs to connect trigger signal. 1. Press “Trigger Menu” and “Select #” knobs to chose channel from what you want trigger oscilloscope Connect triggering signal 2. Press “Trigger Menu ” and “Slope” knobs to chose triggering edge-slope. 3. Tune “MAIN LEVEL” knob to select trigger voltage-level

Run/Stop acquisition measurements If you need to stop after single acquisition measurements then : 1. Press switch to additional knobs menu by press “SHIFT” (blue) and “Acquire Menu” knobs 2. Select “Stop After Average” 2A. To stop after single acquisition measurements select “Single acquisition measurements” 2B. To select non-stop measurements select “ Run/Stop button only” 3. To start or stop measurements press “ “Run/Stop” knob

Averaging of the measurements 1. Press switch to additional knobs menu by press “SHIFT” (blue) and “Acquire Menu” knobs Measured signal 2. Select file format by press “Mode Average” and “Sample” for operation without averaging 3A. Select file format by press “Mode Average” and “Averaging ” for averaging operation 3B. Use scrollbar to select number of the averaging

Save measurements to file (procedure for oscilloscope TDS 744A) 1. Insert floppy disk. Select channel you want to save by press knob “Channel #” and 2. Press switch to additional knobs menu by press “Shift” (blue) and “Save/Recall” knobs Measured signal 3. Select file format by press “File Format” ant then “Spreadsheet” knobs 4.Press “Save wfm (waveform) #” and then “ To file” 5. Use scrollbar to select Tek??? for new file-name in sequence, or select already exist file to overwrite data. Then press “Save to selected file”

Experimental protocol 1- Measure and save luminance signal 2- Measure and save electrical background when luminescence is blocked 3- Measure and save setup respond time

Experimental protocol 1- Measure and save luminance signal 2- Measure and save electrical background when luminescence is blocked Do not change any experimental setting, keep all setting the same as during luminescence measurements, only block excitation pulses before samples !!!! 3- Measure and save setup respond time

Experimental protocol 1- Measure and save luminance signal 2- Measure and save electrical background when luminescence is blocked 3- Measure and save setup respond time Be careful, usually scattering of the excitation pulse much bigger than luminescence signal. Try to avoid saturation of the detector. Try to measure temporal respond time at the same level of the signal like in luminescence measurements

Troubleshooting (Long Kinetics ) AC oscilloscope coupling shows only the alternating components of an input signal. The oscilloscope does not accurately display “long kinetic” with AC coupling is selected.