Confidential Document 1 EverAccess Product Overview By Julian Garcia.

Slides:



Advertisements
Similar presentations
Improvements in EverAccess
Advertisements

Yokogawa Network Solutions Presents:
SCW9057 Key Features/Benefits
Configuring APACS & AAN Controllers
سیستم آلارم دیجیتالی مجهز به ثبات خطا
SK-ACP Installation Overview
XT30/XT50 Basic Training System Overview
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
ModCon® 75 Controller.
POC Security System High security system combining PIN-on-Card, information security, physical access, control and alarm – all in one system.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
WELCOME A Security Masterpiece. Control Panel Line-up Max Zones Basic Zones Max Zones Basic Zones n 1725EX14 6 (4 + 2) n 1728EX15 7 (5 + 2) n 1738EX16.
22 March Controller Diagnostics. 22 March Topics Covered: Diagnostics that allows you to check basic controller and reader functionality through.
GS3055-I GSM Universal Wireless Alarm Communicator
System Capacity MAP 5000 Release 1.2 Feature Overview
1 Strictly confidential | Engineering| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of.
MDR-304 Digital Video Recorder. Can do: - Reliable real time recording of vehicle interiors & surrounding road environment. - Removable recorder unit.
Alarm Mode An in-depth guide. Overview Main module for loading configuration and monitoring system – Reader Open/Close – Arm/disarm zones – Control relays.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
10 February Viewing Controller Status. 10 February Controller Status Provides a “snap shot” of the current configuration of controllers on.
Enterprise Software Solution Lab Pvt Ltd
Access Control ( Software ) June 25, 2010 Created by Castaly / Andy Chen.
SAC844 Anviz Online Training Lesson 8
BioScrypt (OVP) 4G Lite Series
IDEC AUSTRALIA PTY LTD, UNIT 17, 104 FERNTREE GULLY RD, OAKLEIGH, VIC 3166 High Performance, Compact and Economical.
Access Control Line Up Samsung Techwin Europe Ltd.
PICNIC Demo Module 2 IP-based utility outlets 陳育瑋、方煒 台大生機系.
Remote Monitoring and Management Solutions ®
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
Elliteknics AXXESS-E Access Control Solution. Introduction Elliteknics is a company that strives for cutting edge technology solutions, a well- established.
CM-707 Standalone Fingerprint Access Control System CM -707 is biometrics fingerprint recognition standalone access control system.It can store up to 800,1500.
Training.
Data Logger for Water Meter Function Continuously counts pulses from pulse output of the water meter (or other meters with pulse output) and periodically.
Copyright © 2013 FingerTec Worldwide Sdn.Bhd. All rights reserved.
ASPPRATECH.
SF-3000 Installation Manual. 2 Back of SF CON400) USB connector - User can use USB memory stick after connect USB connector of key PCB. CON500)
System Components Hardware overview for Apollo ACS.
29 July System Controller Setup. 29 July Open the Controllers Setup Window Click the Setup System tool bar button OR Select the Setup > System.
System Configuration An in-depth guide. Overview Main module for configuring system – Hardware – Access Levels – Maps – IF/THEN Functions – Operators/Permissions.
ET3100 BioFlex TimeClock. What is fingerprint scanning?  It is a pattern acquisition and recognition established on a person’s.
AXIS 2460 System Overview  AXIS ETRAX 100LX  ARTPEC-1  4 MB FLASH  32 MB RAM  Up to 4 internal IDE hard disks  Linux 2.4.
Looking for a more powerful circuit monitor?
10 February Doors Software Overview. 10 February This presentation is an overview of the basic fundamentals of the Doors software. –Host computer.
TL250-Internet Communicator. Compatibility Specifications VDC current draw 12 VDC input voltage Size: 3.25” × 5.25” (8.3 × 13.3)cm Operating.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
RSG (Remote Service Gateway). 1. Overview  Overview The LDK-RSG (LDK-Remote Services Gateway) is a remote gateway that provides a fully transparent connection.
HP900 (ESP Protocol) Analogue Addressable Control Panels
1 Product & Technology Quality Excellence Support American Global Products Product & Technology TeSysPort Ethernet Interface for TeSys June 5, 2007.
System Overview The Perfect Solution For Small ‘Entry Level’ Access Control Applications August 2014.
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
Paradox Communication Solution GPRS / GSM
2 December, 2015 New Conventional Fire Control Panel.
Copyright © 2008 FingerTec Worldwide Limited. All rights reserved
Confidential Document 1 EverAccess Product Overview By Rodney Guinto.
Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic.
Digital-watchdog.com 960H Advanced DVR Presenter’s Name Title | Product Overview.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
Serial / Ethernet Converter - IE-CS-2TX-XRS232/485
Presenting by Yogesh and Babakhan
SIMPLE & MODULAR PC BASED DOOR ACCESS CONTROL v1.00
COSEC ARC IP based Access Control Panel.
2N® Access Unit Touch Keypad
High Security and Access Systems
IP-AK2 Access Control Solution
2N® Access Unit Touch Keypad
2N® Access Unit Bluetooth
2N® Access Unit Bluetooth
Presentation transcript:

Confidential Document 1 EverAccess Product Overview By Julian Garcia

Confidential Document 2 Introduction Flex Series Controller  The basic model supports 2 readers (doors).  Expandable to 127 controllers (8 readers each) = can support up to 1016 readers per application.  Flexibility to use different model readers in same application.  Integrated keypad and LCD  Real Time Data Transfer  APB Capabilities  Retains 16,000 events in controller (exportable to MS Excel for archiving.)  Streamlined design, attractive appearance

Confidential Document 3 Controller Specs Maximum Cards (Users) Supported: 9,999 Cluster Configuration: Up to 32 Comm. Data Format: Bit Wiegand or RS232 Alarm Input: 1 fire alarm input 1 tamper input Alarm Output: 8 relay outputs, expanded to 16 Communication Port (to PC): RS232/RS485 Programmable Time: 10 intervals per day Programmable Dates: 10 kinds Groups: 256 APB:Yes Keypad: 4 x 4 Display: 2 x 16 LCD Real-Time Clock: Yes Buzzer: Built-in Power: DC 12V + 15% Backup Power connection: Yes Dimensions: 11.7” x 8.4” x 1.3” (30 x 21.6 x 3.3 cm) Power Consumption: Maximum 30 W

Confidential Document 4 Reader Specs Frequency: 125 KHz Data Format: 64 bit Read Range: 5cm-10cm (2-4”) Read Time: 200ms Output Format: Bit Wiegand or RS232 format to EverAccess controller Audio: Built-in Buzzer 2KHz Indicator: 3 LEDs Power Supply: 6.5 V~18 VDC, Max 150 mA Operating Temperature: -10°C ~ +60°C (14°F ~ 140°F) Dimensions: 4.8” x 3” x 0.8” (12.3 x 7.7 x 2.1 cm) Tamper Switch: Standard ERK-871 ERM -871 ERR-871

Confidential Document 5 System Reader (Card Enroller) ERS Connects to PC via USB and Controller via RS485 Frequency: 125 KHz Data Format: 64 bit Read Range: 5cm-10cm Read Time: 200ms Indicator: 4 LEDs Power Supply: 6.5 V~18 VDC, Max 150 mA Operating Temperature: -10°C ~ +60°C (14°F ~ 140°F) Dimensions: 3” x 4.5” x 1.1” (7.6 x 11.6 x 2.9 cm) Tamper Switch: N/A Interface: PC Interface USB or RS485

Confidential Document 6 Biometric Reader EBC Connects to PC via RS232 Fingerprint Verification Time: <3 Sec. Event Record Capacity: 40,000 Communication Format: 26 or 34 Bit Weigand Alarm inputs: 1 Fire, 4 Zones Power Supply: 10V~15 VDC Built In Keypad: 4”X4” Backlit Dimensions: 7” x 5.4” x 2.9” Power Consumption: >9W Max Current Draw: Door Control Relay: 5A Alarm Relay: 2A

Confidential Document 7 FlexPack Parts (EFLP-02-1A) One 2 Door Controller Two Mullion Readers One System Reader Flex Series Software Lock Box Enclosure Power Supply 24 Thick Proximity Cards ECD-50: 50’ Cable

Confidential Document 8 System Configurations: 1 of 3 RS232: Simple 1-to1 Direct Connection  The Controller can be connected directly to the PC via serial port RS232

Confidential Document 9 System Configurations:2 of 3 RS485 Bus System: Multiple controllers in series.  Multiple EverAccess controllers can be connected to accommodate larger access control systems. The controllers are connected via RS485.  The System Reader is a critical component of an RS485 bus based system: it allows simple card enrollment and acts as the interface between multiple controllers and the PC. RS485

Confidential Document 10 System Configurations: 3 of 3 TCP/IP Based Network System  The controller can be networked via TCP/IP in order to remotely manage the controller over internet or intranet.  The EverAccess LAN adaptor (part number EA-LAN1) is required to convert RS232 /RS485 signals to TCP/IP  Maximum: 127 Controllers per system TCP/IP WAN/LAN TCP/IP EA-LAN1 Converter Controller 1 Controller 2 RS486

Confidential Document 11 Controller Operations Operations can be performed at the Controller using the keypad and LCD. There are 10 Setting Menus: 1. System Setting 2. Card Setting 3. Reader Setting 4. Door Setting 5. Alarm Setting 6. Alarm Action Setting 7. Extended Alarm Setting 8. Alarm Time Setting 9. Armzone Setting 10. Address Setting

Confidential Document 12 Controller Operations 1. System Setting: In the System Setting Menu, the user can set basic functions:  System date and date Format  Auto Daylight savings time  Time  System Pin  System Arm Pin  Erase all events  Reset all data and setting  Passwords

Confidential Document 13 Controller Operations 2. Card Setting: In the Card Setting Menu, the user can set basic functions:  Add cards  Delete Card or delete all cards  Set cards priorities, including:  Card status setting (enable/disable card)  Access right setting  Group setting  Set card pin setting  Anti Passback (APB) setting  Card Arm Setting (enable/disable arm/disarm function)  Show card number

Confidential Document 14 Controller Operations 3. Reader Setting:  In the Reader Setting Menu, the user can set basic functions:  Keypad setting  Reader to door allocation  System reader setting

Confidential Document 15 Controller Operations 4. Door Setting:  In the Door Setting Menu, the user can set basic functions, such as:  Door setting  Open time setting  Set door hold open time  Set door behavior at fire time

Confidential Document 16 Controller Operations 5. Alarm Setting: In the Alarm Setting Menu, there are three main sub-menus: - Alarm Action Setting Menu: Configures alarm outputs of all events on the main module and the door module. - Extended Alarm Setting Menu: Configures alarm outputs of all events on alarm module. - Alarm Time Setting Menu: Configures the time period of alarm outputs.

Confidential Document 17 Controller Operations 6. Alarm Action Setting: - In the Alarm Setting Sub-Menu, alarm output configuration for all events is basically the same, for example: - The upper line indicates the card to be configured is an invalid card. - The first 8 characters of the lower line are alarm output status of this event on the door module. - The 2 characters following the minus sign are alarm output status on the Main alarm output and Auxiliary alarm output on the main module. - Y indicates there is alarm output (relay energized). - N indicates there is no alarm output (relay not energized). - R refers specifically to alarm output relay on the corresponding door module.

Confidential Document 18 Controller Operations 7. Extended Alarm Setting: - In the Extended Alarm Setting Sub-Menu, the user can set basic functions, such as: - Fire Alarm - Zone Alarm 1~8 - System, ARM and card PIN failure - ARM IN 0 - Remote Alarm - Unknown, expired and invalid card - Invalid door and time - Card anti-passback failure - Door forced or held open - Reader lost

Confidential Document 19 Controller Operations 8. Alarm Time Setting: - In the Alarm Time Setting Sub-Menu, the user can reset the alarm or set a certain period of time an alarm output remains active. - Use numeric keys to enter the desired alarm time. - Enter minutes as a 3-digit number 0~999 and seconds as a 2-digit number 0~59. - The default value of alarm time is 1 minute.

Confidential Document 20 Controller Operations 9. Armzone Setting: - In the Armzone Setting Menu, the user can set basic functions, such as: - Set active Armzone - Set Arm delay time - ARM delay time: When an arm operation is executed, all active arm zones will enter ARM enabled status only after a certain time delay. - Use numeric keys to enter the desired ARM delay time. - Enter minutes as a 3-digit number 0~999 and seconds as a 2-digit number 0~59.

Confidential Document 21 Controller Operations 10. Address Setting: - Each device connected to the same RS485 bus must have a unique address for the purpose of communications and control. When multiple controllers connect to PC via an RS485 bus, each controller must be assigned a distinct address. - In the Address Setting Menu, the user can set this address setting - Use numeric keys to enter desired address in the range 0000~9999.

Confidential Document 22 Summary Key Selling Points: - Register ANY size project with EverFocus and receive: - System design assistance. - Discount through distribution. - Post installation support. - Simple installations. - Expandable topology.

Confidential Document 23 Contact Information Julian Garcia Office: Ext 107 Fax: Mobile: Rodney Guinto Sr. Sales Engineer Office: Ext 127 Mobile: Link to download manuals: ftp:// /Product%20Manuals/Access%20Control/ftp:// /Product%20Manuals/Access%20Control/