FILTER-AG PLUS ® Automatic backwashing unit to dramatically reduce sediment and colour in rural surface water.

Slides:



Advertisements
Similar presentations
Groundwater What is it and why is it important?
Advertisements

Process Of Reverse Osmosis Plant
MANGANESE GREENSAND To reduce high levels of Iron & Manganese with associated staining and the smell of Hydrogen Sulphide.
WATER SOFTENERS A Luxury that saves you Money. Problem - Hardness Water that contains high levels of dissolved calcium or magnesium salts, or both, is.
PEDAL POWER WATER BIKE A water filter system, which will benefit millions worldwide The pedal power water bike is capable of delivering clean microbiologically.
Australian water filter.
RURAL SURFACE WATER Rivers, Creeks and stock water supplies vulnerable to heavy sediment levels and high turbidity.
RK-60The Ultimate Solution to Community Water Problems A Water Treatment Unit producing clean water at 60 Litres per minute safeguarded from worms, cysts,
ULTRA VIOLET STERILISER 10Gpm – 15Gpm. Sterilight- S8Q PA 30 – 76 litres per minute S12Q PA 42 – 110 litres per minute 99.9% inactivation of even Giardia.
IMPERIAL AQUA K CERAMIC FILTER. Filters Imperial Aqua K Ceramic Filter Comprised of two filters that can be fitted under the kitchen sink, this compact.
MANGANESE GREENSAND To reduce high levels of Iron & Manganese with associated staining and the smell of Hydrogen Sulphide.
ACTIVATED CARBON Granular Activated Carbon may be used for a variety of water treatment applications requiring the reduction of chlorine, tastes, and odours.
WATER TREATMENT SOLUTIONS. Anthony Preston Limited was founded in 1951 (Now a 2 nd generation family business ) We have been providing water treatment.
Waste Water Treatment (Sewage Treatment)
Filtration by Douglas Rittmann, Ph.D., P.E.
CE 370 Filtration.
Benjamin C. Whitehead, PE Benjamin J. Klayman, PhD, PE Case Study: Commissioning New Rapid Sand Filters at Donald K. Shine Water Treatment Plant.
CALCITE For pH Neutralising The pH in water should be between 7 and 8.5 to be compliant with the current NZ Drinking Water Standard’s Guideline Value.
DOULTON ‘ICP’ WATER FILTER Doulton Ceramic Filtration – A Proven System.
BIRM For the reduction of rusty/brown/black staining and metallic taste resulting from Iron and/or Manganese in water.
Antunes Water Filtration Technologies Introduces to You:
ULTRA VIOLET STERILISER 10Gpm – 15Gpm – 24Gpm. Sterilight – UV S12Q-PA litres per minute  99.9% inactivation of even Giardia and Cryptosporidium.
Rural Surface Water Rivers, Creeks and stock water supplies vulnerable to heavy sediment levels and high turbidity.
ETL Multi Media Grey Water Filters and Pre Reverse Osmosis Filtration.
MARKEL Reverse Osmosis Water Purifiers. Markel Unit  There are many people living in rural areas, very worried about the increasing Nitrate levels in.
SETTLING TANKS.
Surface Water Treatment Plant. Fig 4-8: Flow Diagram of conventional surface water treatment plant (“filtration plant”)
Introduction to Environmental Engineering Code No. (PE389) Lec. 5 and 6.
Sand media filtration is one of the oldest filter processes in the world. Water Tool Modular Filters have made extensive improvements to what is presently.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
STILT GROUP Water Treatment Systems & Innovations.
MARKEL Reverse Osmosis Water Purifiers. Markel Unit  There are many people living in rural areas, very worried about the increasing Nitrate levels in.
IMPROVED AND INOVATIVE RURAL WATER SUPPLY DESIGN CONCEPTS
Filtration. Filtration Single Media Rapid Sand Dual Media Rapid Sand.
Done by: Alisa Yasmin, Christabel Robert, Nuzul Nazkhatul, Ganisha, Nata, Kheng Ian & Benjamin 1E1.
Recirculating Systems
Water in the Community: From Lake Ontario to us Thursday, March 25 th.
Done by: Alisa Yasmin, Christabel Robert, Nuzul Nazkhatul, Ganisha, Nata, Kheng Ian & Benjamin 1E1.
Base Oil Recovery System-OilPure for Recovery and Reuse of oils. Pure Tech India, A-5, Trec step, Thuvakudi, Trichy Telephone: ;
Rural, Community & Onsite Wastewater & Waste Management Role of Soil in Biological Treatment.
E NVIRONMENTAL E NGINEERING 441 Lecture 5: Water Treatment (3) Sedimentation & filtration Philadelphia University Faculty of Engineering Department of.
Saving lives, changing minds. Vietnam Red Cross Society – DRT WatSan Training Nepal Red Cross Society - NDRT WatSan Training MAINTENANCE.
PERFORMANCE OF A GRANULAR ACTIVATED CARBON BIOFILTER IN LOW STRENGTH WASTEWATER TREATMENT D. S. Chaudhary, H. H. Ngo and S. Vigneswaran Environmental Engineering.
SETA Water treatment plant maintenance
IN DEEP FILTRATION WMT DEEP-BED FILTER
Water Treatment Plant Austin and Alison.
Soil and Water. SOILS Texture: % of sand, silt, and clay  Amount of water stored in soil.
By: Jim Kibby Fouling and ROI Tools (Return On Investment)
Assignment You need to draw and label each step of the water treatment process Under each label explain what is happening in that step.
 Asia’s largest environment solutions provider, with a strong international presence  Total water & environment management solutions for all sectors.
WATER MANAGEMENT.
Presentation Title Presented by Joe Blow Heat Transfer 101 & ROI.
Filtration Processes Introduction
On removing little particles with big particles
Zeosorb - The Clean Solution. AMAZING REVOLUTION!! LATEST STATE OF THE ART 3 IN 1 SOLUTIONS Zeosorb FOR YOUR WATER FILTERATION UNITS.
What Is In This Chapter? Water Treatment Overview
Safe, Clean and Drinkable
Hub 4 Water Design, build, installation and servicing of all systems
graziers, agricultural, industrial & domestic water users.
Boiler System Make-up Water Primary Secondary Pretreatment
Combined Wastewater Treatment Using a Novel Biofilm Support in an Anaerobic Up-Flow Sludge Blanket Followed By Sand Filtration By Sohair Abou-Elela*,
An-Najah National University
Pre-Engineered Water Surface Water Treatment Plants
Lecture # 11 Water treatment:.
Enhancing Rapid Sand Filtration by Backwashing with Alum
Water use and treatment
Treatment – Sediment Filters
FILTRATION I.
Start Up Procedures and Recommendations for Factory Authorized Equipment Start Up.
MAINTENANCE.
Presentation transcript:

FILTER-AG PLUS ® Automatic backwashing unit to dramatically reduce sediment and colour in rural surface water.

Filter-Ag Plus ®  Filter-Ag Plus automatic backwashing unit is designed specifically for this type of water.  Brilliantly effective in cleaning the water of particulate matter down to the 5 micron or less range (40 micron, approximately smallest visible size).  Clack Filter-Ag Plus is a unique natural ore that has many outstanding advantages over common granular filter sands and multimedia used for suspended solids reduction. Viewed under an electron scanning microscope, the granules reveal an angular shape, rough surface and microporous void spaces as small as 3 microns. This creates a surface area over 100 times greater than silica sand. The angularity of the granules and the tapered internal pore spaces allow for reduction of dirt, silt and organic matter suspended in water by bridging, straining and adhesion. The rough surface and internal porosity provide a high surface area for efficient reduction of suspended matter.

Advantages and Conditions  Deep bed filtration results in superior water quality and reduces the load on downstream equipment.  High sediment removal capacity results in longer filter runs, with a substantial savings in backwash water and time out of service.  Replacement of sand and multimedia with Filter-Ag Plus in existing installations will increase filter capacity.  Water pH: Wide range  Bed Depth: inches  Freeboard: 50% of bed depth  Backwash flow rate: gpm/sq.ft.  Backwash Bed Expansion: 30-40% of bed depth.  Service Flow rate: gpm/sq.ft. Local conditions may require lower flow rates  A gravel support bed is required Filter-Ag Plus is an all-natural,environmentally safe product.

Automatic Backwashing Control valves  Whole House Water Treatment Systems  The control valve is fitted onto a round FRP tank (either 10”x 54” high or 12” x 52” high) filled with Filter-Ag Plus media to correct the water problems associated with surface water.  The system is installed between the pump and a water storage tank or the house to deliver dramatically cleaner water, more acceptable for domestic use.

Installation Recommendations Before putting Filter-Ag Plus filter into service follow these recommended instructions or contact the original equipment supplier.  Slowly fill tank with filter valve in the backwash position until water flows to drain.  Backwash at 15 to 20 gpm/sq.ft. for 5 minutes.  Let material settle for 5 minutes.  Repeat backwash and settle steps for a total of 3 times.  Put the filter to service. Note: For best results allow Filter-Ag Plus to sit submerged in water for a minimum of 12 hours prior to following the above procedure and prior to putting the filter to service. A gravel support bed is required.

Installation Sequence

 For further information please contact:  Sue Kelly  Free phone:  Clients Comments: ‘Dear Sue, Since we have changed the media in the automatic backwashing system, the water coming into the house is so much better, much cleaner. The water in the stock race has been particularly bad – really dirty, but the new granules are getting it cleaner than before. Many thanks’. SK Ashburton ‘We have had water treatment systems installed and maintained by Sue Kelly Water Systems Ltd since Aug 2005, when we moved up from Southland. Needing to take household water from a stock water creek was a shock to us but with the units installed, the water to the house has been clean, clear and safe to drink and we continue to be very happy and would be delighted to recommend Sue to anyone with water problems’ A&K, Ashburton