Estimating Heating Energy from Utility Bills More on the “Phase 2” Adjustment Ecotope, Inc.

Slides:



Advertisements
Similar presentations
Objectives 10.1 Simple linear regression
Advertisements

SEEM Calibration: Revisited Revising the regression to use continuous heat loss variable Regional Technical Forum December 17, 2013.
A Two-Level Electricity Demand Model Hausman, Kinnucan, and Mcfadden.
New Construction Calibration Research Results and Request for Decision Regional Technical Forum March 18, 2014.
BPS - 5th Ed. Chapter 241 One-Way Analysis of Variance: Comparing Several Means.
Residential Single Family Weatherization and HVAC Measures Progress Reports: 1.Estimating Electric and Supplemental Fuels Savings 2.Estimating Value of.
Hypothesis Testing An introduction. Big picture Use a random sample to learn something about a larger population.
ERCOT Analysis of 2005 Residential Annual Validation Using the Customer Survey Results ERCOT Load Profiling Presented to PWG - October 26, 2005.
LECTURE 3 Introduction to Linear Regression and Correlation Analysis
Deeming Savings for Ductless Heat Pumps in Manufactured Homes Regional Technical Forum January 4 th, 2011.
2005 LIEE Impact Evaluation Final Report January 23, 2007 Presentation to the Low Income Oversight Board West Hill Energy and Computing, Inc. with Ridge.
© 2000 Prentice-Hall, Inc. Chap Multiple Regression Models.
Multiple Regression Models. The Multiple Regression Model The relationship between one dependent & two or more independent variables is a linear function.
© 2003 Prentice-Hall, Inc.Chap 14-1 Basic Business Statistics (9 th Edition) Chapter 14 Introduction to Multiple Regression.
1 Confidence Interval for the Population Mean. 2 What a way to start a section of notes – but anyway. Imagine you are at the ground level in front of.
NEEM Manufactured Homes Field Test Results David Baylon, Ecotope.
Electric “Grid” Savings and Non-Electric Benefits for Residential HVAC-effected UES Measures Regional Technical Forum March 20, 2013.
DHP Supplemental Fuel Screen Subcommittee Meeting Regional Technical Forum December 10, 2013.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update March 17, 2015.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update May 12, 2015.
Correlation and Linear Regression
ANCOVA Lecture 9 Andrew Ainsworth. What is ANCOVA?
Inference for regression - Simple linear regression
HAWKES LEARNING SYSTEMS math courseware specialists Copyright © 2010 by Hawkes Learning Systems/Quant Systems, Inc. All rights reserved. Chapter 14 Analysis.
Lecture 14 Multiple Regression Model
© 2002 Prentice-Hall, Inc.Chap 14-1 Introduction to Multiple Regression Model.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Creating a DHP UES Measure Ecotope, Inc. July 16, 2013.
SEEM 94 Calibration to RBSA Data Progress Report on Phase 2 (Digging a Little Deeper) Subcommittee Regional Technical Forum March 20, 2013.
DHP for Houses with Electric FAF Research Plan: Revisions Adam Hadley, Ben Hannas, Bob Davis, My Ton R&E Subcommittee February 25, 2015.
Why Normal Matters AEIC Load Research Workshop Why Normal Matters By Tim Hennessy RLW Analytics, Inc. April 12, 2005.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
Agricultural Irrigation Pump Variable Frequency Drive Provisional Standard Protocol Proposal Regional Technical Forum April 16, 2013.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Northwest Ductless Heat Pump Pilot Project Impact & Process Evaluation: Billing Analysis Ecotope, Inc. February.
SEEM Calibration: Phase-2 Adjustments for Failed VBDD Fits Regional Technical Forum August 12, 2014.
EvergreenEcon.com ESA 2011 Impact Evaluation Draft Report Public Workshop #2 August 7, 2013 Presented By: Steve Grover, President.
DHP Supplemental Fuel Screen Subcommittee Meeting Regional Technical Forum February 12, 2014.
Statistical Inference
Biostatistics Case Studies 2008 Peter D. Christenson Biostatistician Session 5: Choices for Longitudinal Data Analysis.
Path for Multi-Family (MF) Weatherization and NC Measures Christian Douglass 8/18/2015.
SEEM Calibration: Phase II Single Family Heating Energy Regional Technical Forum September 17, 2013 Presented By: Josh Rushton and Adam Hadley Subcommittee.
SEEM Calibration: Phase II Single Family Heating Energy Regional Technical Forum August 20, 2013 Presented By: Josh Rushton and Adam Hadley Subcommittee.
SEEM Calibration for Manufactured Homes Regional Technical Forum July 15, 2014.
Copyright © 2014, 2011 Pearson Education, Inc. 1 Chapter 19 Linear Patterns.
SEEM Calibration: Phase-2 Adjustments for Failed VBDD Fits RTF Calibration Subcommittee July 31, 2014.
Lecture 8 Simple Linear Regression (cont.). Section Objectives: Statistical model for linear regression Data for simple linear regression Estimation.
Inference for Regression Simple Linear Regression IPS Chapter 10.1 © 2009 W.H. Freeman and Company.
Large sample CI for μ Small sample CI for μ Large sample CI for p
Residential Duct Insulation New Deemed Measure Proposal – A Second Look Regional Technical Forum May 4 th, 2010.
McGraw-Hill/Irwin Copyright © 2007 by The McGraw-Hill Companies, Inc. All rights reserved. Chapter 8 Hypothesis Testing.
Comparison of Pooled and Household-Level Usage Impact Analysis Jackie Berger Ferit Ucar IEPEC Conference – August 14, 2013.
2009 Impact Evaluation Concerns ESAP Workshop #1 October 17, 2011.
Copyright ©2013 Pearson Education, Inc. publishing as Prentice Hall 9-1 σ σ.
NEEA DEI Study Data Analysis Plan October 28, 2005 RLW Analytics, Inc. Roger L. Wright, Chairman, and Principal Consultant.
Copyright © Cengage Learning. All rights reserved. 13 Linear Correlation and Regression Analysis.
Electric “Grid” Savings and Non-Electric Benefits for Residential HVAC-affected UES Measures Regional Technical Forum March 20, 2013.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum March 18, 2014.
Heat Pump Research Project Sponsored by the Heat Pump Working Group April 5, 2005.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
ENERGY STAR and Eco-Rated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Multifamily Homes: Calibration Update Regional Technical Forum December 8 th, 2015.
New Construction Calibration Preliminary Research and a Request for Guidance on Issues Raised in December Regional Technical Forum January 22, 2013.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
Sampling Design and Analysis MTH 494 Lecture-21 Ossam Chohan Assistant Professor CIIT Abbottabad.
Where did it go? Lost savings found in real-world data SEEM Calibration for the Northwest Power and Conservation Council’s Regional Technical Forum (RTF)
The inference and accuracy We learned how to estimate the probability that the percentage of some subjects in the sample would be in a given interval by.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum June 17, 2014.
Section 11.1 Day 3.
The simple linear regression model and parameter estimation
Chapter 9 Hypothesis Testing: Single Population
Presentation transcript:

Estimating Heating Energy from Utility Bills More on the “Phase 2” Adjustment Ecotope, Inc

BACKGROUND MATERIAL AND COMMENTS ON VBDD

What is Variable Base Degree Day Regression (VBDD)? Base Load Energy = Base Load + Heating Slope * Heating Degree Days Degree Day Base Heating Slope Sometimes it works very well (like for example this home)…

And other times it doesn’t work at all.

Site level VBDD seems to work pretty well on gas bills! It does not seem to work very well across electric bills. These are all RBSA SF sites, where “Gas n=667” refers to any site with gas bills and “Electric n=699” refers to any site without.

Let’s reiterate. Site level VBDD seems to work pretty well on gas bills! It does not seem to work very well on electric bills. Ecotope’s implementation of VBDD here performed a brute-force search over balance points 48F to 70F. Anything that hit the boundary of the search is not believable or usable.

So we were looking at all bills before – what about just bills from Josh’s spreadsheet. [These] are homes that have some form of permanently-installed electric heat (FAF, BB, or HP). These are meant to represent an electric utility's program- eligible homes with minimal screening. Shown in vertical dashed line is the cutpoint of This looks better than the previous plot for all sites, but it still does not inspire confidence in site-level VBDD with an R^2 cutpoint. BADGOOD

Similarly for the balance points, the picture is better for this smaller set of homes, but still doesn’t look good.

PRISM: An Introduction. MARGARET F. FELS Center for Energy and Environmental Studies, Princeton University, Princeton, NJ (U.S.A.) (Received January 1986) In general, the NAC estimate [Normalized Annual Consumption] provides a reliable consumption index from which energy savings and conservation trends may be accurately estimated. The small standard error of NAC for our sample house… is typical of PRISM results. On the other hand, the three parameters, α [base load], β [heating slope], and τ [balance point], which define a house’s energy signature, are less well determined. VBDD, or PRISM, typically works great on total normalized consumption, but gets a bit dicey when you try to pull out the specific parameters such as base load, heating slope, or balance point. The original PRISM people asserted as much:

Annualized kWh is the total consumption as reported by bills. Normalized Annual Consumption (NAC) is the weather adjusted total. As seen from last slide, NAC is pretty close to AC. Unlike the normalized heating estimate, NAC doesn’t do crazy things.

Back to the R^2 plot, all results from a site-level VBDD investigation must be qualified: BADGOOD Conditional on the R^2 from an unusual regression model exceeding a mostly arbitrary cutpoint of 0.45, here are the savings. What does that even mean? What does that mean for program savings?

CORRECTING FOR HOMES THAT GOT CAUGHT IN THE “BILL FILTER”

BAD GOOD BAD The Main Idea: We want to estimate heating energy from utility bills. We use the Variable Base Degree Day (VBDD) Regression model to do this. The VBDD model works great on some homes, but does not work great on all homes. To separate the two, we have a “bill filter.” The bill filter decides in a crude way whether the VBDD model was appropriate. It excludes sites with low R^2 or with balance points at the boundary of the search 48-70F. For bill streams set aside in this fashion, we cannot use the VBDD estimates for any purposes. We cannot use the heating estimates from VBDD when we acknowledge that the VBDD model has failed.

Back to this example site in which VBDD failed, VBDD cannot tell us anything about the amount of heating energy used at this home.

25% failed bill filter So what can we do? We can look at the difference in annualized energy between the homes that pass the filter and the homes that fail the filter. “Annualized” refers to a weighted average of the observed bills and not a model-based weather normalization. The homes that failed the bill filter used less total energy on average than those that passed the bill filter.

CoefficientDescriptionEstimate*Standard Errorp-val β0β0 Intercept <.001 β1β1 Floor Area (ft 2 ) <.001 β2β2 UA * HDD65 (kWh/yr) <.001 β3β3 Heat Pump (TRUE/FALSE) β4β4 Failed Filter (TRUE/FALSE) < ft 2 higher area  360 higher annualized kWh 1000 kWh higher UA * HDD65  120 kWh higher annualized kWh Presence of Heat Pump  60 kWh lower annualized kWh (not significant) Failed Bill Filter  2800 lower annualized kWh *Estimated w/ RBSA survey weighting Raw kWhAdjusted kWh Passed Filter Failed Filter Difference Adjusted Estimate: 14% less annualized energy

Started with primary electric homes Homes with gas usage removed Homes with missing data removed Homes with Tbal 48F set to failed Regression with RBSA Survey weights to adjust for house size, UA, climate, and heat pump Estimate: 14% lower annualized energy in houses that failed the bill filter (19450 vs kWh / year on average) Assuming houses on both sides of filter use the same proportion of electric use as heat Let X denote heating usage estimated from well-behaved bills Let p denote proportion of well-behaved bills Let C denote a correction factor for misbehaved bills Proposal: C = = 86%. If we take p=25%, then this would downgrade the usage of 25% of the homes by 14%, for an overall reduction of 0.25*0.14 = 3.5%. Proposed Correction Approach Recap

3.5% 8.3% 35%45% Here are the consequences of the adjustment based on annualized total. It is very sensitive to the assumption of how much heat the “mis-behaved” homes use as a fraction of their total bills. For the well-behaved homes, the heat fraction was estimated as 45%. If you assume the mis-behaved homes also use 45% heat then that leads to a 3.5% overall reduction. As an example, if you assume the mis-behaved homes use 35% heat then that leads to an 8.3% overall reduction. Example Alternate Choice

RbsaM Case Studies Summary SiteidReason FailedDiagnosisHeating Energy 10887Tbal 70F and Low R^2Malfunctioning Heat Pump (?)High 11418Tbal 48FProbably realNormal 12507Tbal 70FSpaNormal 13912Tbal 48FNo utility heatingLow 14140Tbal 70FShop (?)Normal 20020Tbal 48FSpaNormal 20230Tbal 70FPossibly realNormal 20469Tbal 48FLarge cooling loadNormal 20998Tbal 48FCooling, Spa, & Well PumpNormal 21143Tbal 48FBad ReadLow 23960Low R^2Bad ReadNormal 24203Tbal 48FProbably realNormal 24375Low R^2Vacations & SpaLow 24684Low R^2Possible Bad ReadsNormal

Final Thoughts: When using site level VBDD we must adjust for the homes that got caught in the bill filter – that didn’t show energy use linear in heating degree days. We don’t know anything about how much heating energy those homes used. We know that overall they used about 14% less total energy A crude adjustment based on the 14% less total energy is unfortunately very sensitive to small changes in the assumption of how much heat the “mis-behaved” homes used, something we know nothing about. Large changes require compelling and conclusive evidence. We do not have compelling and conclusive evidence. We recommend, for now, assuming 45% heating energy for the mis-behaved bills and applying an overall downward adjustment of.25*.14 = 3.5% to usage or savings estimates computed from site level VBDD. The 45% heating energy is equal to the fraction of heating observed from the population for which VBDD reports useable results.