AFM II Imaging Mode: don’t be at zero frequency (because of Noise)

Slides:



Advertisements
Similar presentations
AFM Basics Xinyong Chen.
Advertisements

Atomic Force Microscope (AFM)
Scanning Probe Microscopy
Scanning Probe Microscopy ( STM / AFM )
SCANNING PROBE MICROSCOPY By AJHARANI HANSDAH SR NO
Lecture 10. AFM.
Single Molecule Studies of DNA Mechanics with Optical Tweezers Mustafa Yorulmaz Koç University, Material Science and Engineering.
AFM-Raman and Tip Enhanced Raman studies of modern nanostructures Pavel Dorozhkin, Alexey Shchekin, Victor Bykov NT-MDT Co., Build. 167, Zelenograd Moscow,
Optical Tweezers F scatt F grad 1. Velocity autocorrelation function from the Langevin model kinetic property property of equilibrium fluctuations For.
EMBIO kick-off meeting – Cambridge CSDC - Università di Firenze The Florence EMBIO group: people and scientific activity Lapo Casetti Dipartimento di Fisica.
Polymers PART.2 Soft Condensed Matter Physics Dept. Phys., Tunghai Univ. C. T. Shih.
Imaging of flexural and torsional resonance modes of atomic force microscopy cantilevers using optical interferometry Michael Reinstaedtler, Ute Rabe,
Basic Imaging Modes Contact mode AFM Lateral Force Microscopy ( LFM)
Lecture 3 INFRARED SPECTROMETRY
UNIT IV LECTURE 61 LECTURE 6 Scanning Probe Microscopy (AFM)
History and Applications of Atomic Force Microscopy Gregory James PhD Candidate Department of Chemical Engineering 1.
Get to the point!. AFM - atomic force microscopy A 'new' view of structure (1986) AlGaN/GaN quantum well waveguide CD stamper polymer growth surface atoms.
Atomic Force Microscop (AFM) 3 History and Definitions in Scanning Probe Microscopy (SPM) History Scanning Tunneling Microscope (STM) Developed.
Atomic Force Microscopy
Announcements Mid-Term Test next Tuesday in class! (Oct. 7 th, 9:30-11am, Rm 136LLP) Will cover all of classes Lec 1-10 plus (qualitatively) on Lec 11–
Today’s Topic: AFM Experimental Approach via Atomic Force Microscopy Imaging Mode, Force Mode. Example: Measuring strength of Heart Muscle (Titin) Strength.
Lecture 6 Raman spectra of carbon nanotubes. Infrared (IR) spectroscopy IR 700 nm3500 nm400 nm Visible light IR IR spectra can be used to identify the.
Slide # 1 SPM Probe tips CNT attached to a Si probe tip.
Methods and Tehniques in Surface Science
Measuring DNA Flexibility (Bending & Twisting) Magnetic Traps, WLC How Mag. Traps Work Equipartion Theorem, Brownian Noise Worm Like Chain– model for extended.
TAPPINGMODE™ IMAGING APPLICATIONS AND TECHNOLOGY
Tuning Fork Scanning Probe Microscopy Mesoscopic Group Meeting November 29, 2007.
What has enabled Nanoscience? Advances in Computing Power New Generation of Scientific Instruments Scanning Probe Microscopes An incomplete list.... Very.
2.002 Tutorial Presentation Problem 1-Atomic Force Microscopy Justin Lai.
Introduction & applications Part III 1.HW assigned later today (Due next Monday, 3/8/10). 2.March 15 th, 17 th, night of 18 th : Presentations Reports.
Chapter 13 VibrationsandWaves. Hooke’s Law F s = - k x F s = - k x F s is the spring force F s is the spring force k is the spring constant k is the spring.
NANO 225 Micro/Nanofabrication Characterization: Scanning Probe Microscopy 1.
Introduction to Atomic Force Microscopy
AFM. The cantilever holder The cantilever dimensions Tip position.
Tutorial 4 Derek Wright Wednesday, February 9 th, 2005.
Simple Harmonic Motion It is actually anything but simple! Simple harmonic motion is a special case of periodic motion.
Common scanning probe modes
Sacrificial Bonds and Hidden Length:
Scanning Probe Microscopy Colin Folta Matt Hense ME381R 11/30/04.
Today –Homework #4 Due –Scanning Probe Microscopy, Optical Spectroscopy –11 am NanoLab Tour Tomorrow –Fill out project outline –Quiz #3 in regular classroom.
Atomic Force Microscopy (AFM)
Experimental Protein Folding Atomic Force Microscopy The precursor to AFM, called the Scanning Tunneling Microscope, won the Nobel Prize, Can see.
Today’s take-home lessons (i.e. what you should be able to answer at end of lecture) FRET – why it’s useful, R -6 dependence; R 0 (3-7 nm), very convenient.
Electric Force Microscopy (EFM)
Fachgebiet 3D-Nanostrukturierung, Institut für Physik Contact: Office:
PHYSICS CLASS 9 DEFORMATION Ms. UZMA AMIR Date:
Introduction and applications
AFM Images Bacteria Mosquito eye DNA molecules t&view=article&id=51&Itemid=57.
EEM. Nanotechnology and Nanoelectronics
Introduction & applications Part II 1.No HW assigned (HW assigned next Monday). 2.Quiz today 3.Bending & twisting rigidity of DNA with Magnetic Traps.
SPM Users Basic Training August 2010 Lecture VIII – AC Imaging Modes: ACAFM and MAC Imaging methods using oscillating cantilevers.
Scanning Probe Microscopy
Get to the point!.
Get to the point!.
Scanning Probe Microscopy: Atomic Force Microscope
AFM Images Bacteria DNA molecules Mosquito eye
Characterization of CNT using Electrostatic Force Microscopy
Scanning Probe Microscopy History
Modelling of Atomic Force Microscope(AFM)
Scanning Probe Microscopy History
Tapping mode AFM: simulation and experiment
Atomic Force Microscopy Samrat Dutta, Ph.D.
NANO 230 Micro/Nano characterization
Volume 109, Issue 2, Pages (July 2015)
Jen Chao Presentation November 20, 2008
Simple Harmonic Motion
Atomic Force Microscope
Atomic Force Microscopy
Probing the Energy Landscape of the Membrane Protein Bacteriorhodopsin
AFM modes 1- Contact Mode
Presentation transcript:

AFM II Imaging Mode: don’t be at zero frequency (because of Noise) Force Mode: Worm-Like Chain (WLC): very good for proteins and DNA. AFM

(Back to) AFM Imaging Mode. To minimize noise, go to a higher frequency : noise always goes like 1/f (f = frequency) Force Mode. Force Mode: Worm Like Chain model of Protein Folding (and DNA)

AFM—Imaging Mode(s) Force – one place Imaging – Scan Ionic repulsion, bends tip Imaging – Scan Muller, Biochemistry, 2008 Measure (z-axis) distance, Or Constant force (by altering distance with feedback) http://cp.literature.agilent.com/litweb/pdf/5990-3293EN.pdf http://www.home.agilent.com/agilent/editorial.jspx?cc=US&lc=eng&ckey=1774141&nid=-33986.0.02&id=1774141

Operating Modes of AFM The most commonly used modes of operation of an AFM are: 1. Contact mode AFM (aka C-AFM or CMAFM) 2. Tapping mode AFM (aka TMAFM, IC-AFM or AM-AFM) 3. Noncontact mode (aka NC-AFM, close contact AFM or FM-AFM). (Lots of different names because of patent squabbles!) Contact is often called a static mode, and Tapping and noncontact called dynamic modes, as the cantilever is oscillated in Tapping and noncontact modes. Typically this is done by adding an extra piezoelectric element that oscillates up and down at somewhere between 5-400kHz to the cantilever holder. http://www.afmhelp.com/index.php option=com_content&view=article&id=51&Itemid=57

AFM Tapping (& N.C.) Mode

The main difference between tapping mode and noncontact mode In tapping mode, the tip of the probe actually touches the sample, and moves completely away from the sample in each oscillation cycle. In NC-AFM, the cantilever stays close to the sample all the times, and has a much smaller oscillation amplitude. NC-AFM (noncontact AFM) is more sensitive to small oscillations of the cantilever, so may be operated in close contact (almost touching). Noncontact AFM, unlike the other AFM techniques can obtain true atomic resolution images. AM-AFM, typically used for Tapping mode – where the tip actually taps the sample during each oscillation. This is often the most stable mode to use in air, and so is currently more commonly used than either noncontact or contact modes for most applications. By detecting at non-zero frequency, the noise is often less! http://www.afmhelp.com/index.php?option=com_content&view=article&id=51&Itemid=57

Stay away from DC measurements (when possible) 1/f noise is ubiquitous! If you can measure at non-zero frequency, often due better! Very Common Fig: The plot of the power spectral density S(f) vs. frequency f for a full open state at . A power law , , fits the data quite well. http://www.scholarpedia.org/article/1/f_noise Stay away from DC measurements (when possible) http://iopscience.iop.org/0295-5075/73/3/457/fulltext/epl9165.html

AFM— Force Modes Force – one place http://cp.literature.agilent.com/litweb/pdf/5990-3293EN.pdf http://www.home.agilent.com/agilent/editorial.jspx?cc=US&lc=eng&ckey=1774141&nid=-33986.0.02&id=1774141

Simply Hookian Spring doesn’t fit data well F= - kx Hooke’s Law: You apply a force on something and it increases in length linearly. Proportional constant = k. Minus sign because it’s a restoring force. What does F vs. x look like for a (Hookian) Spring? There’s a lot of entropy which takes energy to straighten (zero) out. DNA is much longer than it is wide – λ DNA (virus DNA) is about 16.5 µm upon full extension, but the molecule’s diameter is only about 2 nanometers, or some four orders of magnitude smaller. Can expect some simplification where don’t need to get into details of molecular bonding. Like liquids– need to know mass density (r), viscosity (h)—forget about details. http://biocurious.com/2006/07/04/wormlike-chains

Two Models of DNA (simple) Freely Jointed Chain (FJC) 2. (more complicated) Worm-like Chain (WLC) Idealized FJC: FJC: Head in one direction for length b, then turn in any direction for length b. [b= Kuhn length = ½ P, where P= Persistence Length] At small z, gives F= -kz. It isn’t a bad fit for ssDNA, where each individual non-paired base acts as an individual segment, but it fails miserably at high forces for dsDNA. FJC: Completely straight, unstretchable. No thermal fluctuations away from straight line are allowed The polymer can only disorder at the joints between segments FJC: Can think of DNA as a random walk in 3-D.

Force vs. Extension for DNA F=-kx works well at very low force; at higher force, DNA is extended (> 50%), need FJC; or better is WLC At very low (< 100 fN) and at high forces (> 5 pN), the FJC does a good job. In between it has a problem. There you have to use WJC. You measure the Persistence length Strick, J. Stat. Physics,1998.

Two Models of DNA 1. (simple) Freely Jointed Chain (FJC) 2. (more complicated) Worm-like Chain (WLC) Realistic Chain: WLC: Have a correlation or persistence length (= Lp). The force extension curve [F(x) versus x is well described by the WLC equation Where Lp: persistence length, a measure of the chains bending rigidity = 2x Kuhn Length L = contour length z = extension

WLC Fits very well at most stretches For DNA The force extension curve [F(x) versus x is well described by the WLC equation WLC works well for DNA and Proteins

WLC for DNA beyond 20 pN What’s happening at forces > 20 pN? The above fit is good to about 10-15 pN, above which the model keeps increasing quicker than the experimental data. This is because the WLC model is an inextensible model, where the chain contour length is constant2. Further modifications to the wormlike chain have introduced an enthalpic correction for higher forces, where the applied force is no longer simply extending the molecule, but has started doing work on the structure itself, deforming it from its regular B-DNA form. This addition makes the model valid up to approximately 60 pN, at which point DNA undergoes a structural phase transition and the force-extension relation changes quite rapidly back to a more Hookean form, extending up to 1.6x its normal contour length before displaying further non-linearities. http://biocurious.com/2006/07/04/wormlike-chains

Biological Example of AFM: Muscle & Titin The striated muscle is organized in cell bundles that contain many muscle cells or “fibers”. These are highly specialized multi-nucleated cells that contain very many elements called myofibrils that contain a number of elements with a characteristic striation all in register with each other under the optical and electron microscopes. These are the contractile units of the muscle and are called sarcomeres. Each sarcomere has a well defined structure that has been described from microscope observations.

Titin: Human’s Biggest protein Silicon Nitride lever: 10’s pN – several nN’s measureable Each domain IgG Titin: 4.2MDa; Gene (on # 2) = 38,138 aa: Goes from Z-disk to Center; stretchy =I Band Cardiac (N2B &N2BA), Skeletal (N2A), Smooth all have different regions.

Reversible Unfolding by AFM Pulling on Titin Simple model: Upon reaching a certain force (peaks), the abrupt unfolding of a domain lengthens the polypeptide by 28 to 29 nm and reduces the force (troughs) to that of the value predicted by the force extension curve of the enlarged polypeptide. Gold Reversible Unfolding of Individual Titin Immunoglobulin Domains by AFM, Science, M. Reif, H. Gaub, 1997

Nontopographic modes of AFM Apart from the topographic modes that collect images, there are many modes designed to measure other properties of the sample. For example: Magnetic Force Microscopy, MFM, measures the distribution of magnetic field in the sample. Kelvin Probe Microscopy (KPM) measures contact potential difference across the sample. Force Spectroscopy can measure individual molecular interactions. Nanoindentation can measure hardness or softness of the sample. Thermal modes can measure thermal parameters, for example, thermal conductivity on the nanoscale. http://www.afmhelp.com/index.php?option=com_content&view=article&id=51&Itemid=57

Obtaining the Tip Geometry For studying the tip influence on the data we need to know tip geometry first. In general, the geometry of the SPM tip can be determined in these ways: 1. use manufacturer's specifications (tip geometry, apex radius and angle) 2. use scanning electron microscope of other independent technique to determine tip properties 3. use known tip characterizer sample (with steep edges) 4. use blind tip estimation algorithm together with tip characterizers or other suitable samples http://gwyddion.net/documentation/user-guide-en/tip-convolution-artefacts.html

The End