Summer Webinar Series Grid-Tied Battery Backup. Introduction Disclaimer ‒ AEE Solar is a distributor of goods and services used in the deployment of PV.

Slides:



Advertisements
Similar presentations
PhotoVoltaic System Sizing © ARJ This is not a How-To presentation. It is a What and Why presentation.
Advertisements

PowerPoint ® Presentation Chapter 4 System Components and Configurations Components Electricity Sources System Configurations.
AC Coupled Systems Growing market segment Can be confusing! Can be complicated! Numerous ways to go MidNite has taken most of the mystique out of the.
Siemens Building Technologies Building Technologies Variable Frequency Drives Harmonics Overview.
Variable Frequency Drives VFD Basics
1 SOLAR SYSTEMS BASICS.  National Electric Code (NFPA # 70) for Photovoltaic Systems  Mechanical Code of New York State for Thermal Systems  Plumbing.
Inverters Alex Stanton Henry Schober III Benjamin Garber Rance.
Foundations of Physics
S Explain parallel circuits, components, and safety of house wiring. S Develop a formula for power consumption and solve related problems.
Lesson 25: Solar Panels and Economics of Solar Power
Chapter 8 Inverters AC Power • Inverters • Power Conditioning Units • Inverter Features and Specifications.
Foundations of Physics
POWER SUPPILES LECTURE 20.
Photovoltaic Solar Cells and Solar Energy Systems for Home Usages Mohammad Anisuzzaman.
Solar Home UPS 850VA & 1400VA India’s first Sine wave inverter with in built Solar Charge Controller and Controlled DC Load Output. Simultaneous Charging.
During a mains supply interruption the entire protected network is dependent on the integrity of the UPS battery as a secondary source of energy. A potential.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE PV APPLICATIONS CODES AND STANDARDS EMERGENCY RESPONSE.
1. Presentation Overview  Solar Industry Overview  Intro into Solar Photovoltaics  Types of PV Systems  Solar Product Offering –Solar Combiner Boxes.
Generac Automatic Standby Generators Providing 24/7 Automatic Power Protection.
MidNite Solar’s Pre wired solutions for Off Grid, Battery based Grid tie and AC coupled. MidNite Solar
MidNite Solar’s Pre wired solutions for Off Grid, Battery based Grid tie and AC coupled. MidNite Solar
Solar Lightings Solar Module. Charge Controller. Battery. Inverter. Loads Accessories.
Solar PV Design Implementation O& M March 31- April 11, 2008 Marshall Islands 2. Solar Home Systems (SHS) 2. Solar Home Systems (SHS) Herb Wade PPA Consultant.
Off-Grid Power Using Enphase Micro-Inverters Off-grid inverter systems, using batteries, can be used to provide AC power when the grid is down. It is possible.
Sustainable Energy Systems Engineering Peter Gevorkian Ch 2: Solar Power Generation Design Brevard Community College EST1830 Bruce Hesher.
Power Grid and Your Home
Power Generation from Renewable Energy Sources Fall 2013 Instructor: Xiaodong Chu : Office Tel.:
© Planetary Power, Inc All Rights Reserved. PRODUCT INTRODUCTION.
Objectives Review electric circuits and electricity pricing - Introduce HW5 Select conductor and conduit List electrical devices.
Batteries Storing Renewable Energy “Chemical engines used to push electrons around”
Technician License Course Chapter 5 Amateur Radio Equipment Lesson Plan Module 12: Power Supplies and Batteries & RF Interference (RFI)
Designing Solar PV Systems (Rooftops ). Module 1 : Solar Technology Basics Module 2: Solar Photo Voltaic Module Technologies Module 3: Designing Solar.
Introducing… OutBack Power’s Radian Series GS8048 Inverter/Charger.
Electrical Power Systems
PV System Components Advanced Engineering The Technology Landstown High School.
1 INTRUSION ALARM TECHNOLOGY POWER SUPPLIES. 2 INTRUSION ALARM TECHNOLOGY Security systems shall have a primary power source and a secondary power source.
Charge Controllers Regulating Battery Charging.
Electrical power. Objectives Use the equation for electrical power to solve circuit problems. Understand basic concepts for home electricity usage and.
Energy Storage Applications at AEP Emeka Okafor American Electric Power Presentation to SouthWest Electric Distribution Exchange May 7, 2009.
Photovoltaic Systems – Residential Scale Part 2 April 2, 2014.
Balance of Systems (BOS)
Red Rocks Community College ENY 130 Grid-Tied PV Fall 2009 Module 2.
Station Backup Power & Solar Powering your station.
Off Grid Living Without a Generator Solar Powered AC Coupled Micro Grid © Boyd Solar corp. Didsbury, AB
We hear much about energy problems; supply shortages, pollution issues and high prices, but the solutions to these problems are here now in the form of.
Fall 2009 Module 8 Inverters. Converts the DC power produced by the solar modules into AC power used on the utility grid.
ELECTRICAL SYSTEMS. Chapter Twenty One: Electrical Systems  21.1 Series Circuits  21.2 Parallel Circuits  21.3 Electrical Power.
Introduction to Solar Photovoltaic (PV) Systems – Part 2
Electrical Power Distribution Information obtained from howstuffworks.com.
Battery Backup PV Systems Design Considerations
SERVICE ENTRANCE EQUIPMENT
PHY 202 (Blum)1 More basic electricity Non-Ideal meters, Kirchhoff’s rules, Power, Power supplies.
Powered by the Sun, Sustainable through Quality. Who is Suncolect Suncolect provides Solar electricity solutions to entrepreneurs in small, medium and.
What Will We Do If Our Oil Supply Runs Out?. What Will We Do Click here to get an answer! If Our Oil Supply Runs Out?
Unit 7, Chapter 20 CPO Science Foundations of Physics.
SP series solar Pump inverter Introduction. Application.
SEC598F16 Photovoltaic Systems Engineering Session 12 PV System Components Inverters Balance of Systems (BOS) October 04, 2016.
Photovoltaic and Battery Primer
Photovoltaic and Battery Primer
Photovoltaic Systems Engineering Session 22 Solar+Storage Systems
Energy Consumption: HOME.
Energy. Anytime. Anywhere.
Sizing Methodologies • Sizing Calculations
Photovoltaic Systems Engineering Session 16 Solar+Storage Systems
Regulating Battery Charging
Objectives Learn about Electricity Pricing Electric systems.
Objectives Learn about 3 Phase vs. 1 phase F&N vs. 1 phase F&F
Components inverters Except where otherwise noted these materials are licensed Creative Commons Attribution 4.0 (CC BY)
Presentation transcript:

Summer Webinar Series Grid-Tied Battery Backup

Introduction Disclaimer ‒ AEE Solar is a distributor of goods and services used in the deployment of PV and wind distributed power systems. We are not accountants, attorneys or code experts. The information presented here represents the equipment and best practices that we are aware of. However, local and project-specific requirements can vary widely.

Why Add Batteries? The market for grid-tied battery PV systems is expected to grow at over 70% per year through at least 2017 Battery technology has gotten cheaper and easier to use If you offer battery backup options, you don’t have to refer those customers away for a quote Energy storage reduces dependency on net metering (and the grid altogether) − Hawaii utilities likely to restrict or eliminate net metering − Net metering under attack nationally − Globally, biggest PV markets are off- grid Increasingly frequent severe storms and natural disasters are impacting aging grid infrastructure − Over 14 Million businesses and households were without power after major storms in 2012 and 2013 − About another million have been without power after storms so far this year Time-of-use (TOU) rate structures make energy management quantitatively valuable − California expected to have residential TOU rates by 2016

Battery Backup Applications Homeowners are looking for comfort and peace of mind ‒ High-end homes on the outskirts of the grid ‒ Critical medical devices Businesses are looking for opportunities ‒ Convenience stores ‒ Data centers, web hosts, etc. Local governments are looking for safety and order ‒ Schools and storm shelters ‒ Police, fire and medical services

Energy Storage & Management Solutions Homeowners want control of their energy ‒ Homes where net metering is restricted (HI) ‒ Large homes with TOU rate structures Businesses want opportunities ‒ Businesses facing demand charges and/or complicated TOU rate structures Local governments and utilities need services that overcome intermittency ‒ Demand response with energy storage ‒ Opportunistic supply or even load

Types of grid-tie battery backup systems Backup system separate from the solar grid-tied system Grid-tied solar systems with battery backup and protected loads panel ‒ Basic DC coupled grid-tie w/ Battery Backup (GTBB) ‒ GTBB using 120vAC only inverters with 120vAC loads ‒ GTBB using 120vAC only inverters and 120/240vAC loads ‒ GTBB using 120/240vAC inverters Grid-tied solar systems with battery backup for whole house backup ‒ GTBB for whole house using a 4 pole manual transfer switch ‒ GTBB for whole house using line side tap and manual transfer switch ‒ GTBB for whole house using an automatic transfer switch Grid-tied solar systems using AC coupling ‒ GTBB using AC coupling and protected loads panel

Direct grid-tied system without backup This is a simple grid-tie system without any backup power When the grid power goes out, the PV system is useless

Backup system separate from the solar grid-tied system The backup system can be separate from the solar system This could also be a generator only or have both inverter and generator

Basic DC coupled grid-tie w/ Battery Backup (GTBB) The original and most common arrangement for grid-tie with backup DC coupled with low voltage array, charge controller, and battery-based grid-tie inverter Protected loads panel for loads to be backed up

GTBB using 120vAC inverters with 120vAC loads Many grid-tie battery inverters are 120vAC single leg These inverters also have only one AC input Transfer switch needed for running with a generator Generator must have utility quality AC power output Inverter-based generator is required

GTBB using 120vAC inverters with 120/240vAC loads GTBB 120vAC system w/protected load panel and transformer for 240vAC loads Use standard US house wiring at 120/240vAC Grid connection and generator input is still only 120vAC

GTBB using 120/240vAC inverters with protected load panel Using a 120/240 split phase inverter with separate generator input is the most versatile and easy to use system A protected loads panel is still the best way to set up Grid connection and generator input are both 120/240vAC

Whole house backup issues NEC 702 5(B) requires a system that can power all loads if an automatic transfer switch is used, ‒ Exception for loads that are automatically disconnected ‒ A 200 A service would require six Radian 8 kW inverters A Manual transfer switch only requires the system to power chosen loads ‒ User must manually shut off non-critical circuits before switching ‒ Manual transfer will leave the house in the dark until someone performs the transfer If the inverter cannot power all the loads it will be overloaded and shut off, requiring a manual restart The input/grid-feed and output of the inverter must never be connected together ‒ This will irreparably damage the inverter and may cause a fire ‒ Connecting the input to the utility side of the meter is most common approach

Whole house backup with automatic transfer switch Requires a backup system capable of powering all loads, or having loads automatically disconnected per NEC 702 5(B) 200A service requires six Radian 8kW inverters unless automatic circuit disconnects are used Requires a line tie connection to the utility

Array differences from direct grid-tie systems String sizing is smaller, commonly 3 modules in series Array wiring similar but more strings Generally strings are combined on the roof or near the array A PV combiner with circuit breakers is needed Short strings reduce shading impacts

Voltage sourced o Inverter builds its own waveform Fixed low-voltage input o Inverter fed from steady 12/24/48 VDC from batteries PV array MPPT provided by charge controller o Charge controller dictates string size Modest efficiency: 75-90% Low-voltage single-phase output o 120 or 240 VAC Current sourced o Inverter uses grid waveform Actively controlled voltage input o Inverter uses MPPT and accepts wide range of voltages Inverter provides PV array MPPT o String sizing dictated by inverter High efficiency: 95-98% Range of outputs o 240 VAC or 208/277/ phase Battery-Based InvertersGrid-Tie Inverters

AC coupled GTBB system Normally uses a protected loads panel Uses both a direct grid-tie inverter and a battery-based inverter Is useful when retrofitting an existing system Is useful when a kWh production meter is needed More expensive and complex, not all equipment is compatible

PV array managed by charge controller o 3 modules/string o Separate combiners Battery inverter actively manages export power o Exports power based on battery voltage/state of charge o Automatically disconnects from grid during outage PV array managed by grid- tie inverter o modules/string o Integrated combiner Battery inverter passes export power through o Battery inverter uses GT inverter output to charge or maintain battery bank o Automatically disconnects GT inverter from grid during outage DC-Coupled SystemAC-Coupled System

AC-Coupled Systems Can make use of existing GT inverter and PV array o Good retrofit solution High-efficiency export of surplus power o Can be better for backup applications Distance between array and inverter can be greater o Higher voltage Requires 2 inverters o ~$1,200 more in equipment costs for 7kW array Less efficient battery charging o Usually worse for off-grid applications Not all GT inverters work well in AC-coupled mode o Battery inverter must have at least 25% more capacity than GT inverter o Check with GT inverter manufacturer for compatibility AdvantagesDisadvantages

Battery Options for Backup Systems Fully mature technology Flexible and standardized Low float losses Life driven by cycles o <1,000 to 2,000 New technology Works with most (but not all) traditional power electronics Environmentally Benign (no toxics) 3,000+ cycle life Valve-Regulated Lead-Acid (VRLA) Sodium-IonLithium-Ion Compact and light weight Enables high-voltage batteries Special safety considerations 3,000+ cycle life

User Data You Will Need to Collect Critical loads ‒ What loads does the user expect to run during an outage? ‒ For each load, multiply the power draw by the hours it is used per day ‒ For appliances, divide the Energy Star annual consumption kWh by Peak load (Watts) ‒ Sum of all loads that may be run simultaneously ‒ Voltage the loads require (120 vs. 240 VAC) Hours/days of backup required ‒ How many hours or days in a row will the loads need to run ‒ Are outages likely to be accompanied by long periods of inclement weather? Sun-Hours per day during darkest month (kWh/m 2 /day) ‒ This is the available solar resource ‒ Use Winter Solstice time frame rather than annual average for best results For AEE Internal Use Only.

Load analysis: talk to your customer Protected vs. non-protected loads: what do they really need? ‒ Refrigerator/freezer, lights, ventilation, TV/computer, cell phone charger, alarms Heating systems vary widely and may or may not be practical to back up ‒ Air handlers can be a very large energy load, even if the heat source is gas ‒ Electric water heaters can be a very large load How long do they really need the backup to last? ‒ Batteries drive the total system cost more than the PV or inverter ‒ The larger the loads and the longer they run, the more expensive the system will be ‒ A 100 kWh battery bank (50 kWh/day for 2 days), is likely to cost about $20,000 Can they add a generator if the backup needs to be larger or last longer? Manage the customer’s expectations! ‒ “A protected loads panel is far more convenient and cost-effective than whole- house backup” ‒ Accurate load analysis is worth the time and will result in more satisfied customers ‒ Ensure your customer understands how much energy they can expect from their backup system and the risks of overloading it

Load Analysis Load Worksheet – ‒ 2013 AEE Solar Design Guide and Catalog - page 10 For AEE Internal Use Only.

Battery Bank Sizing

PV Array sizing Sizing the PV array for GTBB systems is similar to a grid-tie system Limits to array size: ‒ 100% offset of electrical use ‒ Available space ‒ Budget At minimum, the array should power the backup loads for an extended outage Sizing for an extended outage needs to account for winter solar production unless the system will also have a generator

Charge Controllers Charge controllers for modern 60 cell modules must be MPPT type ‒ MPPT = Maximum Power Point Tracking An MPPT controller will convert the input voltage to the correct voltage for charging the battery Array voltage must be higher than the battery voltage Charge controllers are current limited ‒ A 4kW array will need one 80A change control for a 48 VDC battery, but will require two controllers for a 24 VDC battery ‒ 80 A x 48 VDC = 3,840 W, 80 A x 24 VDC = 1,920 W The PV array will rarely put out full rated power except at high altitude sites ‒ Reasonable oversizing of array vs. charge controller can minimize cost ‒ Always have overcurrent protection between array and controller

PV Array Sizing (For MPPT Charge Controllers) String operating voltage must be between battery charging voltage and controller limit (usually 150 VAC) ‒ Power will drop off dramatically if the charge point of the array falls below the battery voltage A 48 VDC battery charges at 56 VDC or more ‒ 2 modules x 26.1 VDC = 52.2 VDC ‒ 2 modules in series will typically not charge a 48 VDC battery Most 60 cell modules will exceed 150 VDC in strings of 4 A 48 VDC battery requires 3 modules in series only A 24 VDC battery can typically use either 2 or 3 modules in series

PV array combiner boxes Each parallel string of modules must have circuit protection ‒ There is no current limiting electronics device between the battery and the combiner box ‒ Almost all modules now have a 15 A circuit rating The breakers in these circuits must be rated for the maximum voltage ‒ Maximum voltage for many of these systems will be 150 VDC High-voltage charge controllers require higher voltage breakers or fuses All array circuits going to each charge controller must have a separate and isolated feeder to that charge controller Some combiner boxes have the capacity for two separate circuits ‒ Multiple combiners may be more convenient for wire management

Inverter Sizing Considerations Inverter must meet the larger of array size or load size ‒ The inverter needs to be large enough to power all of the loads that will be put on it during a power outage ‒ A grid-tied inverter also must handle entire PV array power ‒ This connection does not exist for off-grid systems Will any loads require 240 VAC power? ‒ Same as for off-grid systems Wire the protected loads panel for normal North American distribution of 120/240 VAC split phase or just 120 VAC? Will the installation use a backup generator? ‒ Will it be 120 VAC only or 240 VAC?

Balance of System: Charge Controller Circuit Protection Disconnects and circuit protection are required between the PV array, charge controller, and battery ‒ Battery string disconnects (right) can simplify maintenance and trouble shooting A circuit breaker is normally used for 150 VDC PV circuits ‒ This breaker should be rated at either the sum of the combiner breakers or the maximum input for the charge controller ‒ Wire between breaker and the combiner box must meet or exceed the current rating of the breaker used The charge controller breaker and disconnect serves as the battery breaker ‒ Must be rated for continuous duty ‒ Can simply match the charge controller output rating ‒ If the charge controller will be operated near its limit, oversize the battery breaker slightly to avoid nuisance tripping

Inverter Sizing Find maximum AC load ‒ Identify and sum all loads that may run simultaneously ‒ Sum up total Watts – this is the minimum inverter continuous power rating Identify any loads with high start-up or surge current draws ‒ Motors in compressors, fans and appliances ‒ Gauss rifles/rail guns, electromagnets and other large inductive loads ‒ Largest surge load determines minimum inverter surge rating Identify any loads that may require 240 VAC ‒ 240 VAC often requires transformer or dual inverters Be sure to consider inverter’s no-load-draw when sizing battery system and array

Power Systems Factory pre-wired power systems are available to simplify design and installation ‒ Several common sizes & configurations Most power systems include: ‒ Inverter(s) ‒ Controller and networking devices ‒ Battery monitor ‒ Integration hardware and BOS ‒ Enclosures, Breakers, GFDI, Bypass, etc. ‒ Charge controllers (optional)

System Controllers Automate battery management ‒ Float and equalization charge timing Turn on/shut off inverters and/or generators according to time of day or battery state of charge Remote monitoring/control via Internet

Battery Backup Does Add Cost Battery backup functionality adds about $2/W to equipment costs ‒ This varies with battery vs. PV array size Additional labor is required to install the batteries Depending on customer needs, household circuits may need to be rewired Many customers who would like backup will not have the cash to pay for it Financing battery backup systems has been a challenge – but it is getting easier A battery backup PV system costs twice as much as a grid- direct PV system…