“Measuring Antigen Specific T-cells using Surface and Intracellular Staining Polychromatic Flow Cytometry” 4th Annual CFAR Flow Cytometry Wet-Workshop.

Slides:



Advertisements
Similar presentations
Key Variables in ICS Assays
Advertisements

Building a Panel Select markers Select conjugates Method to build panel performance criteria.
A. a). d). c). f). b).e). g). Figure S1. NAT2 expression in lymphocytes and monocytes from a healthy volunteer. PBMC from a healthy volunteer were simple.
Design and optimization of multicolor panels Holden T. Maecker.
Steps to Success with Multicolor Flow Cytometry
Quality Control in Immunophenotyping Dr. N. Varma Prof. & Head – Hematology Post Graduate Institute of Medical Education & Research (PGIMER), Chandigarh.
Early HIV cohort: Frozen PBMC samples from all 37 HIV-1 infected subjects; (77% of subjects within 6 months of seroconversion) (HIV negative or control.
Compensation: It’s not just for pretty pictures. Fluorescence Spillover Compensation Simple in concept… Correct spillover into different parameters Straightforward.
2013 Duke CFAR Flow Cytometry Workshop Data Analysis.
Assays of Immune Function. Some Definitions BrdU: bromodeoxyuridine (incorporated into DNA during cell division) CBA: cytometric bead array DC: dendritic.
Page 1 © J.Paul Robinson, Purdue University BMS 602 LECTURE 9.PPT BMS LECTURE 10x Flow Cytometry: Theory Bindley Bioscience Center Purdue.
31 subjects with sufficient viable cells studied for T cell and MAIT cell phenotype * One subject was excluded from CD38+HLA-DR+ T cell analysis 30 subjects.
“Measuring Antigen Specific T- cells using Surface and Intracellular Staining Polychromatic Flow Cytometry” 3 rd Annual CFAR Flow Cytometry Workshop 6-10.
2014 Duke CFAR Flow Cytometry Workshop Data Standards and Annotation.
Intracellular Cytokine Staining (ICS) Flow Cytometry Assay 1 Kent J. Weinhold, Duke CFAR Director November 6th, 2013 CFAR Director’s Meeting Flow Cytometry.
Applications of flow cytometry in basic immunology Generation and characterization of DC Assays for T cell activation –Cell proliferation – Cell division.
Flow Cytometry and Reproducible Analysis Cliburn Chan Department of Biostatistics and Bioinformatics, DUMC.
2013 Duke CFAR Flow Cytometry Workshop Data Standards and Annotation.
How to evaluate the immune response and identify immunedeficit… Dr M.L. Romiti.
Detection of Immune Responses in Mucosal T-cells in Kenya Jackton Indangasi 2, Hannah Cheeseman 1, Onyango J. I. Obila 2, Simon Ogola 2, Robert Langat.
Flow cytometry to evaluate vaccine-induced T cell responses: standardized analysis of large numbers of FCS files Stephen De Rosa, M.D. HVTN Laboratory.
Flow Cytometry Performance Evaluation and Training Program (FlowPET): Mission Statement Flow Performance Evaluation and Training (FlowPET) is an open collaborative.
Laboratory QA/QC An Overview.
CDER Meeting: Surrogate Markers of Immunity Presenter: Judith A. Britz, Ph.D. October 16, 2000.
Laser Flow Cytometry Forward Scatter indicates size Forward Scatter.
Potential Applications of Flow Cytometry Cell activation statusCell activation status Cell cycle distributionCell cycle distribution Cell divisionCell.
Cytometry tutorial: The impact of adjusting PMT voltages on spillover and compensation Thomas Myles Ashhurst1,2,3, Adrian Lloyd Smith3,4 1Viral Immunopathology.
Dotplots CD3 CD4 Allow for visualizing relationship between two different parameters that is not apparent by histogram analysis.
Cytometry tutorial: The impact of adjusting PMT voltages on spillover and compensation Thomas Myles Ashhurst1,2,3, Adrian Lloyd Smith3,4 1Viral Immunopathology.
Greg Finak, Ph.D., Senior Staff Scientist Marylou Ingram ISAC Scholar
Flow Cytometry Halima Moncrieffe, University College London, UK IL-17
A. B. EXP #1: 3 donors EXP #2: 3 donors EXP #3: 6 donors EXP #4:
Forensic Flow Cytometry
Volume 66, Issue 6, Pages (June 2013)
Figure e-1A.
WT1-specific T-cell responses in high-risk multiple myeloma patients undergoing allogeneic T cell–depleted hematopoietic stem cell transplantation and.
COMPENSATION + FITC - PE - + PE - FITC - FITC detector FITC PE
Engineering Human Peripheral Blood Stem Cell Grafts that Are Depleted of Naïve T Cells and Retain Functional Pathogen-Specific Memory T Cells  Marie Bleakley,
“Analyses of Pre-therapy Peripheral Immunoscore and Response to
Selective expansion of polyfunctional pathogen-specific CD4+ T cells in HIV-1–infected patients with immune reconstitution inflammatory syndrome by Yolanda.
Reduced TH1/TH17 CD4 T-cell numbers are associated with impaired purified protein derivative–specific cytokine responses in patients with HIV-1 infection 
Human CD1c+ dendritic cells secrete high levels of IL-12 and potently prime cytotoxic T-cell responses by Giulia Nizzoli, Jana Krietsch, Anja Weick, Svenja.
Measurement of Cell Surface Receptors
by Jason M. Brenchley, Mirko Paiardini, Kenneth S. Knox, Ava I
Skin-Resident Effector Memory CD8+CD28– T Cells Exhibit a Profibrotic Phenotype in Patients with Systemic Sclerosis  Gang Li, Adriana T. Larregina, Robyn.
Type 3 innate lymphoid cells induce proliferation of CD94+ natural killer cells  Shuo Li, PhD, Hideaki Morita, MD, PhD, Beate Rückert, Sci Tec, Tadech.
by Vladia Monsurrò, Ena Wang, Yoshisha Yamano, Stephen A
Comparison of primary human cytotoxic T-cell and natural killer cell responses reveal similar molecular requirements for lytic granule exocytosis but differences.
FLT3 ligand administration after hematopoietic cell transplantation increases circulating dendritic cell precursors that can be activated by CpG oligodeoxynucleotides.
Functional leukemia-associated antigen-specific memory CD8+ T cells exist in healthy individuals and in patients with chronic myelogenous leukemia before.
Reconstitution of Natural Killer Cells in HLA-Matched HSCT after Reduced-Intensity Conditioning: Impact on Clinical Outcome  Caroline Pical-Izard, Roberto.
J. Joseph Melenhorst, Phillip Scheinberg, Ann Williams, David R
Volume 34, Issue 1, Pages (January 2011)
Lisa A. Palmer, George E. Sale, John I
The Art of Flow Cytometry
Volume 19, Issue 11, Pages (November 2011)
Dysregulation of proinflammatory versus anti-inflammatory human TH17 cell functionalities in the autoinflammatory Schnitzler syndrome  Rebecca Noster,
Flow cytometric characterization of γδ T cells in our patient demonstrates specific expansion of a homogeneous Vδ2+ T cell population. Flow cytometric.
Flow cytometry analysis of TNF-β- and IL-10-producing CD33+ cells.
Volume 11, Issue 11, Pages (June 2015)
Volume 36, Issue 1, Pages (January 2012)
Cytotoxic T Lymphocyte Antigen-4 Accumulation in the Immunological Synapse Is Regulated by TCR Signal Strength  Jackson G. Egen, James P. Allison  Immunity 
Theoretical Immunology: Aging
High-dimensional analysis of effector CD4 T cell function following γHV68 infection in B6 and IL-10KO mice. High-dimensional analysis of effector CD4 T.
IL-33, IL-25, and TSLP induce a distinct phenotypic and activation profile in human type 2 innate lymphoid cells by Ana Camelo, Guglielmo Rosignoli, Yoichiro.
by Martin Felices, Behiye Kodal, Peter Hinderlie, Michael F
1. Use the brightest fluorophores available. Brightness Expression
Intracellular TNF-α and IL-4 expression in gated CD33+ monocytes by three-color flow cytometry. Intracellular TNF-α and IL-4 expression in gated CD33+
ALT-803 stimulates proliferation and activation of human NK cells and T cells in vitro. ALT-803 stimulates proliferation and activation of human NK cells.
Surface CD4 and CD14 and intracellular TNF-α expression in PBMCs
Presentation transcript:

“Measuring Antigen Specific T-cells using Surface and Intracellular Staining Polychromatic Flow Cytometry” 4th Annual CFAR Flow Cytometry Wet-Workshop 13-17 October, 2013 Janet Staats Flow Cytometry Core Facility Center for AIDS Research Duke University Medical Center E-mail: jotti@duke.edu CYTOKINE FLOW CYTOMETRY: This presentation describes the work of a number of individuals at BD Biosciences / BD Immuno-cytometry Systems, as well as external collaborators, in optimizing and applying cytokine flow cytometry assays to the study of antigen-specific T cells.

Workshop Overview ICS Assay Instrument Qualification Reagent Qualification Titration Spillover Panel Development / Assay Qualification Operator Qualification Training Proficiency Testing Data annotation Data Analysis Compensation Gating Back-gating Uniform/Standardized Gating Bioinformatics and Statistics

Workshop Overview ICS Assay Instrument Qualification Reagent Qualification Titration Spillover Panel Development / Assay Qualification Operator Qualification Training Proficiency Testing Data annotation Data Analysis Compensation Gating Back-gating Uniform/Standardized Gating Bioinformatics and Statistics

Memory CD4 T Cell Response to Ag IL-2 IL-4 Rantes Apoptosis EVENTS IN THE PATHWAY OF CD4 T CELL ACTIVATION: Measurement of cytokine production can be done within hours of T cell stimulation, before confounding effects of proliferation and/or apoptosis. This allows cytokine flow cytometry (CFC) assays to be highly quantitative. IFNg TNFa APC-T cell interactions Cytokine/Chemokine expression Proliferation/ Death From H. Maecker Duke University Medical Center

APC CD4+ T cell T, B, or APC CD8+ CTL Ag APC CD4+ T cell Whole protein MHC II CD4 cytokines MHC I STIMULATING CD4 VERSUS CD8 CFC RESPONSES: This diagram illustrates that when whole proteins are used for stimulation in CFC assays, the preferred pathway of antigen presentation is via class II MHC. This allows prefential detection of CD4 T cell responses. Some CD8 responses can also be detected, via cross-presentation of soluble antigen on class I MHC. However, since cross-presentation is inefficient, the preferred method of detecting CD8 CFC responses is via use of peptides (or pools of peptides) that bypass the requirement for antigen presentation. peptide T, B, or APC CD8+ CTL Optimal peptide CD8 cytokines MHC I From H. Maecker Duke University Medical Center

Response to CMVpp65 Peptide Mix pp65 protein peptide mix A2 peptide CMV lysate 0.27% 0.27% 0.04% 7.41% CD4 0.19% 2.03% 1.14% 0.87% CD8 From H. Maecker

Peptide Mixes 15 a.a. 11 a.a. CMV pp65: pool of 138 peptides HIV p55: pool of 120 peptides Duke University Medical Center

Sampson Clinical Trial: 11-Color Maturation/Function Panel Basic Subset Markers: CD3 (T-cells) CD4 (T-Helper Subset) CD8 (T-Suppressor Subset) Exclusion Markers: CD14 (Monocytes) CD19 (B-cells) vAmine (Dead cell marker) Maturational Markers: CD45RO – CD45RA CD27 – CD197 (CCR7) CD57 Functional Markers: CD107 IFN- TNF IL-2 Duke University Medical Center

Overview of 11-Color Assay Thursday - Friday Monday Tuesday Wednesday 1. Thaw 2. Stimulate 3. Surface Stain 4. Lyse/Fix 5. Permeabilize 6. IC Stain 7. Acquisition 8. Analysis Brefeldin Monensin 6 h 7+g+M+ g+M+ M+ Rest 6 hrs Wash Wash Wash Wash CD107 cytokine lymphocyte erythrocyte CD8+ CM Response Costim SEB CMVpp65 Amine CD45RA CD197 CD3 CD4 CD8 IFN IL2 TNF CD107 Duke University Medical Center

Workshop Overview ICS Assay Instrument Qualification Reagent Qualification Titration Spillover Panel Development / Assay Qualification Operator Qualification Training Proficiency Testing Data annotation Data Analysis Compensation Gating Back-gating Uniform/Standardized Gating Bioinformatics and Statistics

Instrument Performance: Gel smeared on flow cell

Instrument Performance: Low Staining Index

Instrument Performance: Variance in noise

Instrument Calibration: Use of target channels

Instrument calibration vs biological variation Note: instrument fluorescence detectors are set using established target channel values, allowable range <5% variance daily

Instrument calibration vs biological variation Note: instrument fluorescence detectors are set using established target channel values, allowable range <5% variance daily 1Mar13: DP06_008 9Nov12: 009 & 010 14Nov12: DP06_013 20Nov12: DP06_014 & 017

Instrument calibration vs biological variation 3Jan13: DP06_018 6Nov12: DP06_012 16Feb13: DP06_020 23Jan13: DP06_019 1Mar13: DP06_008 9Nov12: DP06_009 14Nov12: DP06_013 20Nov12: DP06_014 9Nov12: DP06_010 20Nov12: DP06_017 Note: instrument fluorescence detectors are set using established target channel values, allowable range <5% variance daily

Batch Processing Error CD38 vs HLA-DR Staining on Ctrl 5L 28Feb08 5L CD8+ Lot 05262 04Marb08 5L CD8+ Lot 05262 06Mar08 5L CD8+ Lot 05262 11Mar08 5L CD8+ Lot 05262 Duke University Medical Center

Batch Processing Error CD38 vs HLA-DR Staining on Ctrl 5L 26Feb08 5L CD8+ Lot 05262 28Feb08 5L CD8+ Lot 05262 04Marb08 5L CD8+ Lot 05262 06Mar08 5L CD8+ Lot 05262 11Mar08 5L CD8+ Lot 05262 Duke University Medical Center

Workshop Overview ICS Assay Instrument Qualification Reagent Qualification Titration Spillover Panel Development / Assay Qualification Operator Qualification Training Proficiency Testing Data annotation Data Analysis Compensation Gating Back-gating Uniform/Standardized Gating Bioinformatics and Statistics

Titration: objective results MRA

Titration: subjective results MRA

Optimization using Spillover Assessments: Using Titration Files to Assess Spreading Error <Blue B-A> <Blue A-A> Blue Laser CD3AC (5ug/ml) Spillover assessment: After compensation CD3AC showed spilllover into Blue-B detector (FITC channel) <Violet H-A> Violet Laser <Red C-A> <Red B-A> Red A-A Red Laser <Green E-A> <Green D-A> <Green C-A> <Green B-A> <Green A-A> Green Laser Violet G- CD3 AmCyan Ottinger, et. al., Poster #28, 23rd Annual Clinical Cytometry Meeting (2008) Mahnke, et. al. Clin Lab Med. 2007 September; 27(3): 469-v. Lamoreaux, et. al., Nature Protocols 1, 1507-1516 (2006) on line 9 November 2006 Duke University Medical Center

Spillover Assessments: CD3 AmCyan (5µg/mL) Spillover into CD27 (0 Spillover Assessments: CD3 AmCyan (5µg/mL) Spillover into CD27 (0.32µg/mL) & CD57 FITC (1.8µg/mL) Spillover from CD3AC interferes with detection of dim CD27 pos cells Spillover from CD3AC does not interfere with detection of CD57 Spillover is acceptable if it does not interfere with proper classification of events mAb concentration may be varied to reduce spillover as long as frequency is unaffected 0.13 9.8e-4 Unstained Unstained 66.3 20.5 SSC CD27 FITC SSC CD57 FITC Conc may be varied to reduce spillover to acceptable limits … again, decreasing conc is ok as long as frequency is unaffected (classification remains accurate) …another way to say same thing : most important that spreading error does not interefere with classification, but ok to happen as long as no interference (certain amount acceptable) 4.58 0.047 CD3 AmCyan CD3 AmCyan Blue B Blue B Duke University Medical Center

Tandems Degrade! Ice Dark Fix Controls 6 hours Maecker, et. al. Duke University Medical Center

Ship tandems at 4ºC

Panel Development: FS Test

Workshop Overview ICS Assay Instrument Qualification Reagent Qualification Titration Spillover Panel Development / Assay Qualification Operator Qualification Training Proficiency Testing Data annotation Data Analysis Compensation Gating Back-gating Uniform/Standardized Gating Bioinformatics and Statistics

Why is Reproducibility Important? CFSE Standardization Results (13 EXPERT IM Labs): Very high inter-laboratory variability. High background in some laboratories. Responses to Gag and Nef peptide pools were detected in HIV negative (control) donors! Example Gag stimulation HIV negative donor Example CMVpp65 stimulation CMV positive donor % CD8+ CFSE low Laboratory Duke University Medical Center

Intra-Operator Comparison

ICS Proficiency Testing Results: March 2007 Duke University Medical Center

History of Flow-based Proficiency/Standardization Efforts 22 pp Duke University Medical Center

Workshop Overview ICS Assay Instrument Qualification Reagent Qualification Titration Spillover Panel Development / Assay Qualification Operator Qualification Training Proficiency Testing Data annotation Data Analysis Compensation Gating Back-gating Uniform/Standardized Gating Bioinformatics and Statistics

Improperly annotated data

Workshop Overview ICS Assay Instrument Qualification Reagent Qualification Titration Spillover Panel Development / Assay Qualification Operator Qualification Training Proficiency Testing Data annotation Data Analysis Compensation Gating Back-gating Uniform/Standardized Gating Bioinformatics and Statistics

How would you gate? Markers: CD3 CD4 CD8 IL-2+IFNg (FSC) (SSC) Duke University Medical Center

ICS Standardization Conclusions ICS assays can be performed by multiple laboratories using a common protocol with good inter-laboratory precision (<20% C.V.), that improves as the frequency of responding cells increases. Gating is a significant source of variability, and can be reduced by centralized analysis and/or use of standardized gating. Cryopreserved PBMC may yield slightly more consistent results than shipped whole blood. Use of pre-aliquoted lyophilized reagents for stimulation and staining can reduce variability. Grouping: <0.1%, 0.1-0.5%, >0.5% BMC Immunology 2005, 6:13 http://www.biomedcentral.com/1471-2172/6/13 Duke University Medical Center

Gating bias in proficiency panel results IL2+IFN PE Unstim CEF CMV pp65 0.02% 0.01% 0.16% 0.03% 0.17% 0.21% CD4 FITC Duke University Medical Center

Compensation: False Positive CD4 Response to CEF Pepmix mSA EOLm

Compensation: False Positive CD4 Response to CEF Pepmix

Backgating: Include CD3dim+ cells in gate

Backgating: Include CD8dim+ in gate

C (3.1%) B (3.4%) J (4.8%) A (6.8%) K (9.4%) D (10.2%) H (10.2%) F (10.5%) I (12.7%) E (13.4%) G (16.9%) Here labs are listed in order of their total TNFa response. It is visually apparent that, while all labs had overcompensation, it is worst in labs with the lowest cytokine responses.

C (3.1%) B (3.4%) J (4.8%) A (6.8%) K (9.4%) D (10.2%) H (10.2%) F (10.5%) I (12.7%) E (13.4%) G (16.9%) Here labs are listed in order of their total TNFa response. It is visually apparent that, while all labs had overcompensation, it is worst in labs with the lowest cytokine responses.

CIC ICS Gating Panel 110 labs participated and there were 110 different approaches to gating

CIC ICS Gating Panel McNeil et. a. Cytometry A. 2013 Aug;83(8):728-38

Reproducible analysis allows us to measure an expansion of CD4+ CM cells post vaccination with some degree of confidence N CM EM TE E Pre-Vaccination 33% 21% 27% 2% 17% Post-Vaccination 8% 48% 25% Duke University Medical Center

Would you know a positive if you saw one? 2xSD? RCV? Outside Normal Range >0.05%? “Another aspect of analysis of ICS experiments that affects reproducibility across laboratories is the question of how to define a positive response. Criteria for determining a positive response can range from simply subtracting background to twofold, threefold, or even fourfold above background to more complex statistical analyses” Roederer. Cytometry Part A, 73A:384-385 (2008) Horton et. al. J Immuno Methods, 323:39-54 (2007) Maecker et. al. Cytometry Part A, 69A:1037-1042 (2006) Comin-Anduix et. al. Clin Cancer Res, 12(1):107-116 (2006) Duke University Medical Center

Workshop Overview ICS Assay Instrument Qualification Reagent Qualification Titration Spillover Panel Development / Assay Qualification Operator Qualification Training Proficiency Testing Data annotation Data Analysis Compensation Gating Back-gating Uniform/Standardized Gating Bioinformatics and Statistics – Death-by-excel!

Assay Complexity Duke University Medical Center

Endpoints for 11-Color Maturation/Function Panel DEATH BY EXCEL …….. Basic (3) Maturation (5) Function Boolean (16) CD4+ CD8- CD4+ CD8+ CD4- CD8+ Naïve Central Memory Effector Memory Effector Terminal Effector CD107 IFN- IL-2 TNF- Basic (3) Maturation (5) Boolean (16) 240/stim X X = X 3 Stimulations/Sample (CoStim, SEB, CMVpp65) = 720 Endpoints/Sample 720 Endpoints/Sample x 200 Samples (192 Participants + 8 Controls) = 144,000 Endpoints/Trial Note 1: Frequency of parent only, reporting units of #cells/µL doubles the total EP/trial Duke University Medical Center

Data Annotation - for all 143,280 data points! Study ID Method Assay Name Batch # Operator Sample ID Visit ID Accession # % Viable (Flow) % Viable (Guava) Recovery CD4 count CD8 count Gate Name (Parameter Names) Tube Name File Name Error Code (1-11) Checking: X1 - for electronic data X3 - for manual entry Requires STRONG statistical support: Quickly exceeds limits of excel Format data for statistical analysis FJ: column (gates) vs row (file) CSV: column (identifiers) vs row (single value) Check data Manual check: 8sec/value x 143280 = 49 days!!! Duke University Medical Center

Specimen processing matters N=60 samples, stained across 5 batches Duke University Medical Center

Acknowledgements VRC Steve Perfetto Laurie Lamoureaux Mario Roederer EQAPOL Duke CFAR Kent Weinhold Jennifer Enzor Twan Weaver Cliburn Chan Scott White Duke Tisch Brain Tumor Center Gary Archer Duane Mitchell John Sampson CVC Sylvia Janetski Lisa McNeil Duke University Medical Center