Electrical Cable Aging: What does IEEE Std. 1205-2000 Recommend? Module 5 Dr. John H. Bickel Evergreen Safety & Reliability Technologies, LLC.

Slides:



Advertisements
Similar presentations
1 NRC Status and Plans for License Renewal – A Role for Consensus Standards Allen Hiser, Jr. Robert Gramm Stacie Sakai Division of License Renewal Office.
Advertisements

Electrical Cable Aging: What does IAEA Recommend? Module 2 Dr. John H. Bickel Evergreen Safety & Reliability Technologies, LLC.
Risk Assessment for Cultural Institutions: Fire Testing vs Computer Modeling Frederick W. Mowrer, Ph.D., P.E. Department of Fire Protection Engineering.
Lessons Learned from the Application of Risk Management in the Shipment of LNG.
Overview of CWA Section 316(a) Evaluations of Power Plants with Thermal Discharges in Maryland Presented at EPRI Workshop on 316(a) Issues: Technical and.
1 Component Design Basis Inspection (CDBI) Graydon Strong 6/17/14.
EQUIPMENT VALIDATION.
Seismic Considerations & Power Bushings
Outline of Presentation Introduction to Analog Interfaces, Inc. Introduction to the Indenter Polymer Aging Monitor Principle of Indenter measurements How.
TRAMPUS Consultancy Virtual Defense-in-Depth Concept in RPV Integrity Assessment P. Trampus 1st Hungarian-Ukrainian Joint.
W Reliability Centered Maintenance w Day II w Salih O. Duffuaa.
Eurocode 1: Actions on structures –
Main Requirements on Different Stages of the Licensing Process for New Nuclear Facilities Module 4.7 Commissioning Geoff Vaughan University of Central.
DITSCAP Phase 2 - Verification Pramod Jampala Christopher Swenson.
Electrical Cable Aging and Condition Monitoring Codes and Standards for Nuclear Power Plants Electrical Cable Task Group (ECTG) Co-Chairs: Dr. Stephanie.
© ABB Group August 13, 2015 | Slide 1 Power Generation Service Life Cycle Management for Power Plants Daniel Looser, Power Gen Europe in Amsterdam, June.
Energy Management Proposed At KTPS. Objectives for Energy Management Generate energy at lowest possible price Manage energy use at highest energy efficiency.
A variety of load cases, ranging from nominal to degraded or abnormal operating conditions, were studied both numerically and analytically. The reviewers.
Economic Analyses of FPL’s New Nuclear Projects: An Overview Dr. Steven Sim Senior Manager, Resource Assessment & Planning Florida Power & Light Company.
IEC Activities Related to Electrical Cable Aging Dr. John H. Bickel Evergreen Safety & Reliability Technologies, LLC.
Main Requirements on Different Stages of the Licensing Process for New Nuclear Facilities Module 4.5/2 Design Geoff Vaughan University of Central Lancashire,
Fuel Behavior in Long-term Management of Spent Light-Water Reactor Fuel International Conference on Management of Spent Fuel from Nuclear Power Reactors.
TENNESSEE VALLEY AUTHORITY WATTS BAR NUCLEAR PLANT Ed Freeman Engineering Manager 1.
Regulatory Approach to the Lifetime Management of the Nuclear Power Plants in Korea June 30, 2004 Choi, Kyung Woo Korea Institute of Nuclear Safety International.
Resource Planning Georgia Power’s Diverse Plan to Meet Georgia’s Energy Needs AWMA Fall 2010 Conference October 7, 2010 Jeff Burleson Director of Resource.
0 PUT TITLE HERE Update on Capital Programs September 2008.
Configuration Management Benchmarking Group Conference June 6 – 9, 2004 Kansas City, MO © 2004 CMBG Configuration Management Fundamentals including Margin.
Southern Taiwan University Department of Electrical engineering
Westinghouse Operational Experience and Prospects for New Build
Opting for “Long Term Operations” Technical, economic and regulatory considerations MARC Conference June 8, 2010 Sean Bushart, EPRI Sr. Program Manager.
Maintaining the Flow ! Testing of Nuclear Feedpumps (and other important pumps)
Technical Working Group on Nuclear Power Plant Instrumentation and Control Vienna, May 2009 NATIONAL REPORT ON NUCLEAR POWER PLANT INSTRUMENTATION AND.
TWG-NPPIC, May 2009, Vienna: UK status1 Current status of NPP I&C in the United Kingdom T P Smyth AMEC, Knutsford, Cheshire, UK 22 nd Meeting of the Technical.
Recent Experience on Building Collapses under Snow Loads Stewart Macartney – blyth+blyth.
Presented to: Transport Airplane Metallic and Composite Structures Working Group and Airworthiness Authorities By: Walt Sippel and Mike Gruber Date: Sept.
Electrical Cable Aging and Condition Monitoring Codes and Standards for NPPs Dr. Stephanie Watson Engineering Laboratory NIST 100 Bureau Drive, MS 8615.
Main Requirements on Different Stages of the Licensing Process for New Nuclear Facilities Module 4.5/1 Design Geoff Vaughan University of Central Lancashire,
Analytical Approaches to Evaluate Residual Cable Lifetime Module 4 Dr. John H. Bickel Evergreen Safety & Reliability Technologies, LLC.
System Monitoring at the DAEC SysMon SMART Teaming up to get the most out of System Monitoring!
Advisory Committee on Reactor Safeguards Full Committee Davis-Besse Nuclear Power Station Final & Supplemental Safety Evaluation Report November 4, 2015.
IAEA International Atomic Energy Agency Methodology and Responsibilities for Periodic Safety Review for Research Reactors William Kennedy Research Reactor.
IAEA International Atomic Energy Agency IAEA Safety Standards for Research Reactors W. Kennedy Research Reactor Safety Section Division of Nuclear Installation.
Regional Meeting on Applications of the Code of Conduct on Safety of Research Reactors Lisbon, Portugal, 2-6 November 2015 Diakov Oleksii, Institute for.
PP571.1 The Prospects for New Nuclear Construction Eugene S. Grecheck Vice President Nuclear Support Services ANS Virginia Section Meeting March 16, 2004.
Advanced Inspection Techniques for Monitoring Cable Aging Module 3 Dr. John H. Bickel Evergreen Safety & Reliability Technologies, LLC.
IAEA International Atomic Energy Agency INTRODUCTION Module 2.
IAEA International Atomic Energy Agency AGEING MANAGEMENT ASSESSMENT Module 9 Session 9 Resource document: AMAT Guidelines, Reference document for Ageing.
I & C.
1 Public Meeting with ASME to Discuss Pump Inservice Testing Issues NRC Headquarters OWFN Room 1F22 June 4, 2007.
Safety Assessment of General Design Aspects of NPPs (Part 2) IAEA Training Course on Safety Assessment of NPPs to Assist Decision Making Workshop Information.
Tacis 1.14/91 on life-time evaluation TACIS Project: R8.01/98 – TRANSLATION, EDITING AND DIFFUSION OF DOCUMENTS (Result Dissemination) Tacis R1.14/91,
Failure Modes and Effects Analysis (FMEA)
G. Sliter, EPRI N. Wilmshurst, EPRI J. Carey, EPRI F. Polaski, Exelon Corp. Nuclear Safety Symposium Seoul, Korea 1 April 2005 Status of License Renewal.
Use and Conduct of Safety Analysis IAEA Training Course on Safety Assessment of NPPs to Assist Decission Making Workshop Information IAEA Workshop Lecturer.
REACTOR PRESSURE VESSEL
Status and Prospect of Korean Korea Electric Power Research Institute
DCPP Performance Based on NRC Performance Indicators
GREENHOUSE GAS EMISSIONS INVENTORY
Mild Environment Qualification and Maintenance
South Carolina Perspective on Part 61 Proposed Revisions
Flooding Walkdown Guidance
Mitigation of Beyond Design Basis Events (MBDBE) Rule Implementation
IEEE 383 Standard for Qualifying Electric Cables and Splices for Nuclear Facilities Preview SC-2 May 12, 2014 Robert Konnik.
IEEE SC-2 International Standard Review
Complementarity of deterministic and probabilistic approaches
EQ programs at Mochovce NPP – Severe Accident Cases
INRAG Public Conference, April 13 – 14, Aachen, Germany
SAE battery safety standards committee UPDATE January 23, 2019
INRAG Public Conference, April 13 – 14, Aachen, Germany
I&C requirements and configuration management
Presentation transcript:

Electrical Cable Aging: What does IEEE Std Recommend? Module 5 Dr. John H. Bickel Evergreen Safety & Reliability Technologies, LLC

Objectives Describe origins of IEEE Std Describe origins of IEEE Std Describe requirements of standard regarding electrical cables Describe requirements of standard regarding electrical cables Describe results of recent application in the US Describe results of recent application in the US NOTE: Standard covers all electrical components. Emphasis will be on “difficult to replace” electrical cables for which justification to use as- is will be sought. Emphasis will be on “difficult to replace” electrical cables for which justification to use as- is will be sought.

Origin of IEEE Std Many US NPP licenses expiring in next 10 years. Many US NPP licenses expiring in next 10 years. N.R.C. issued License Renewal regulation permitting life extension subject to demonstration of acceptable safety N.R.C. issued License Renewal regulation permitting life extension subject to demonstration of acceptable safety Previous IEEE Std standard felt to be too “open ended” in considering “all possible aging mechanisms”. Previous IEEE Std standard felt to be too “open ended” in considering “all possible aging mechanisms”. Question: “How much is enough?” Question: “How much is enough?” IEEE standard developed as industry – regulator consensus on acceptable aging management program to demonstrate acceptable safety for electrical equipment. IEEE standard developed as industry – regulator consensus on acceptable aging management program to demonstrate acceptable safety for electrical equipment.

Basis of New IEEE Std Major NPP systems, components have been continually refurbished or replaced over their lifetimes. Major NPP systems, components have been continually refurbished or replaced over their lifetimes. - Steam Generators, RPV head - Turbine rotors - Pumps, motors, valves - I&C systems, plant computers Original power (and portions of I&C) cable not typically replaced for other reasons. Original power (and portions of I&C) cable not typically replaced for other reasons. Incorporation of new materials aging data Incorporation of new materials aging data It is desired to demonstrate safety basis for acceptability of existing cabling and connectors. It is desired to demonstrate safety basis for acceptability of existing cabling and connectors.

Objectives of IEEE Std Standard deals with all types of electrical equipment. Standard deals with all types of electrical equipment. EQ standards (IEEE Std ) deal with thermal, radiation pre-aging for purposes of conducting DBA qualification tests. EQ standards (IEEE Std ) deal with thermal, radiation pre-aging for purposes of conducting DBA qualification tests. IEEE Std credits that equipment typically operates for long periods at below pre-aging temperature, radiation levels. IEEE Std credits that equipment typically operates for long periods at below pre-aging temperature, radiation levels.

IEEE Std Process:

Aging Assessment Process

1. Define Evaluation Boundaries What is being evaluated? What is being evaluated? What support features are included? What support features are included? What are system interfaces? What are system interfaces? What are system boundaries with interfacing systems? What are system boundaries with interfacing systems? Why this is done: To demonstrate at end of job that all systems covered, no duplications, but also no omissions

2. Identify Intended Safety Function What safety function does system provide for DBA? What safety function does system provide for DBA? What other safety functions is system credited for? What other safety functions is system credited for? Why this is done: Frequently systems are credited for different roles in different scenarios.

3. Identify Plant Locations Identify specific rooms or zones of equipment. Identify specific rooms or zones of equipment. Why this is done: Routing of support features such as signal and power cables needed for determining most limiting rooms or zones.

4. Identify Service Conditions What are environmental conditions in each of the rooms or zones? What are environmental conditions in each of the rooms or zones? Temperature, radiation, moisture….. Temperature, radiation, moisture….. Which rooms or zones are most limiting? Which rooms or zones are most limiting? Why this is done: Identifies locations of likely greatest stressors for aging-related degradation.

5. Identify Equipment Materials What types of materials for this system are located in each room or zone? What types of materials for this system are located in each room or zone? Which materials in the system are most limiting? Which materials in the system are most limiting? Why this is done: A system may have both Power and Instrumentation cables in the same zone. Instrumentation cables may be more limiting.

6. Identify and Assess Aging Effects What aging effects are possible for given materials and environmental stresses? What aging effects are possible for given materials and environmental stresses? Which aging effect is most limiting? Which aging effect is most limiting? Why this is done: Identification of conditions to be monitored, bases for future calculations

Thermal and Radiation Aging Models

IEEE Std starts with standard aging models based Arrhenius type aging and radiation damage type aging. IEEE Std starts with standard aging models based Arrhenius type aging and radiation damage type aging. Allows credit for actual operating experience which may show significantly reduced aging rates. Allows credit for actual operating experience which may show significantly reduced aging rates.

Consideration of Operating Experience Cabling in areas of highest temperature and radiation levels is typically limiting. Cabling in areas of highest temperature and radiation levels is typically limiting. Typical EQ efforts conservatively assume, 40 years at 100% capacity factor. Typical EQ efforts conservatively assume, 40 years at 100% capacity factor. High capacity factors imply higher radiation doses and exposure to highest temperatures. High capacity factors imply higher radiation doses and exposure to highest temperatures. Actual operation may be less limiting and should be taken into consideration in projecting residual cable lifetime. Actual operation may be less limiting and should be taken into consideration in projecting residual cable lifetime.

Projecting Residual Cable Lifetime Based on Operating Experience Based on actual operating history conservative “envelope” on temperature or radiation can be constructed. Based on actual operating history conservative “envelope” on temperature or radiation can be constructed. “Envelope” is conservative but also more realistic. “Envelope” is conservative but also more realistic.

Construction of Effective Time at Temperature Desire is to construct effective temperature T eff for residual life calculations. Desire is to construct effective temperature T eff for residual life calculations. Assume total time t tot Assume total time t tot

Condition Monitoring

Observation, measurement, trending of condition indicators with respect to critical parameter known to cause degradation. Observation, measurement, trending of condition indicators with respect to critical parameter known to cause degradation. Example parameters: Example parameters: cumulative radiation dose cumulative time at effective temperature Monitor: degradation vs. radiation dose Monitor: degradation vs. radiation dose Monitor: degradation vs. time at T eff Monitor: degradation vs. time at T eff

Acceptable Condition Monitoring

Some Results from Applying IEEE Std

What is Max T eff for 60 Years ?

Calvert Cliffs SER Findings: Effects of Aging “The cable insulation material types include silicone rubber, ethylene propylene rubber (EPR), crosslinked polyethylene (XLPE), crosslinked polyolefin (XLPO), mineral, Kapton, polyvinyl chloride, Teflon, and other miscellaneous insulation types. The external environment is air. The applicant identified the applicable ARDMs as thermal aging, synergistic thermal and radiative aging, and insulation resistence reduction. Although the license renewal rule requires management of aging effects and does not require specific identification of ARDMs, the applicant elected to evaluate specific ARDMs. The applicant considered a comprehensive list of potential ARDMs in its evaluation. The staff finds this acceptable because the potential ARDMs of thermal/radiative aging, and insulation resistence reduction are considered to be plausible for cables. Accordingly, the staff finds the applicant's approach of identifying ARDMs acceptable because aging effects are results of ARDMs.”

Calvert Cliffs SER Findings: The operating experience information in the application indicates that the number of cable failures during normal operating conditions (all voltage classes) that have occurred throughout the industry have been extremely low. However, thermal aging resulting in embrittlement of insulation is one of the most significant aging mechanisms for low-voltage cable during normal operating conditions. The operating experience information in the application indicates that the number of cable failures during normal operating conditions (all voltage classes) that have occurred throughout the industry have been extremely low. However, thermal aging resulting in embrittlement of insulation is one of the most significant aging mechanisms for low-voltage cable during normal operating conditions.

Calvert Cliffs SER Findings: Effects of Synergistic Thermal and Radiative Aging “Group 3 cables may be subjected to synergistic radiative and thermal aging when both aging mechanisms are active and at least one may be significant. Radiation-induced and thermal-induced degradation in organic materials (cable jacket and insulation) produces changes in the organic material properties, including reduced elongation and changes in tensile strength. Visible indications of radiative/thermal aging may include embrittlement, cracking, discoloration, and swelling of the jacket and insulation. To manage the aging effects on Group 3 cables, they will be replaced before the extended period of operation if they are found to have plausible aging.”

IEEE Std Process Aging Management Process has proven to be: Aging Management Process has proven to be: Orderly Orderly Repeatable Repeatable for both NPP operators making license extension applications and for NRC in reviewing and approving. for both NPP operators making license extension applications and for NRC in reviewing and approving.

License Renewal Status in US: License Extensions Approved: Calvert Cliffs, Units 1 and 2 Oconee Nuclear Station, Units 1, 2 and 3 Arkansas Nuclear One, Unit 1 Edwin I. Hatch Nuclear Plant, Units 1 and 2 Turkey Point Nuclear Plant, Units 3 and 4 North Anna, Units 1 and 2, and Surry, Units 1 and 2 Peach Bottom, Units 2 and 3 St. Lucie, Units 1 and 2 Fort Calhoun Station, Unit 1 License Extensions Pending: McGuire, Units 1 and 2, and Catawba, Units 1 and 2 - Joint application received June 14, 2001 H.B. Robinson Nuclear Plant, Unit 2 - Application received June 17, 2002 R.E. Ginna Nuclear Power Plant, Unit 1 - Application received August 1, 2002 V.C. Summer Nuclear Station, Unit 1 - Application received August 6, 2002 Dresden, Units 2 and 3, and Quad Cities, Units 1 and 2 - Application received January 3, Farley, Units 1 and 2 - Application received September 15, Arkansas Nuclear One, Unit 2 - Application received October 15, D.C. Cook, Units 1 and 2 - Application received November 3, 2003