Gamma rays detectors 1) Comparative characteristics of detectors

Slides:



Advertisements
Similar presentations
Topic 8. Gamma Camera (II)
Advertisements

NUCP 2371 Radiation Measurements II
Neutron detectors and spectrometers 1) Complicated reactions → strong dependency of efficiency on energy 2) Small efficiency → necessity of large volumes.
Gamma-Ray Spectra _ + The photomultiplier records the (UV) light emitted during electronic recombination in the scintillator. Therefore, the spectrum collected.
X-Ray Astronomy Lab X-rays Why look for X-rays? –High temperatures –Atomic lines –Non-thermal processes X-ray detectors X-ray telescopes The Lab.
Detector systems 1) Anti-Compton spectrometers 2) Pair spectrometers 3) Crystal spheres, walls, complex set-ups of semiconductor and scintillation detectors.
Dispersive property of a G-M tube HV - + In the proportional region a G-M tube has dispersive properties tube voltage.
W. Udo Schröder, 2009 Rad. Int. with Matter: Gammas Interaction of Radiation with Matter Gamma Rays 1.
Scintillators. When radiation interacts with certain types of materials, it produces flashes of light (scintillation) Materials that respond this way.
Semiconductor Device Physics Lecture 3 Dr. Gaurav Trivedi, EEE Department, IIT Guwahati.
Light. Photons The photon is the gauge boson of the electromagnetic force. –Massless –Stable –Interacts with charged particles. Photon velocity depends.
Principles of Radiation Detection
Lesson 17 Detectors. Introduction When radiation interacts with matter, result is the production of energetic electrons. (Neutrons lead to secondary processes.
GAMMA RAY SPECTROSCOPY
Scintillators.
High Energy Detection. High Energy Spectrum High energy EM radiation:  (nm)E (eV) Soft x-rays X-rays K Soft gamma rays M Hard gamma.
Radiation Safety level 5 Frits Pleiter 02/07/2015radiation safety - level 51.
Techniques for detecting X-rays and gamma-rays Pair production Creation of elementary particle and its antiparticle from a photon. Occurs only if enough.
Main detector types Scintillation Detector Spectrum.
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Radiation Sensors Zachariadou K. | TEI of Piraeus.
Detectors of charged particles and ions 1) Gas filled detectors a) Ionization chambers b) Proportional counters c) Multiwire chambers d) Time projection.
Gamma Spectroscopy HPT TVAN Technical Training
Radiation Detection and Measurement II IRAD 2731.
Detectors The energy loss of particles in matter can be used detect and identify those particles. There are different types of “detectors”: - Gas-filled.
Scintillation Detectors
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
Gamma ray spectrum, its acquiring and analysis
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
Photon detection Visible or near-visible wavelengths
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze: Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS Detection.
History of nuclear spectroscopy
1 Scintillators  One of the most widely used particle detection techniques Ionization -> Excitation -> Photons -> Electronic conversion -> Amplification.
Radiation Detection and Measurement, JU, First Semester, (Saed Dababneh). 1 Spectrum if all energy is captured in detector. Allows identification.
EDS Energy Dispersive Spectroscopy
Techniques for determination of deep level trap parameters in irradiated silicon detectors AUTHOR: Irena Dolenc ADVISOR: prof. dr. Vladimir Cindro.
Tools for Nuclear & Particle Physics Experimental Background.
NEW COMMENTS TO ILC BEAM ENERGY MEASUREMENTS BASED ON SYNCHROTRON RADIATION FROM MAGNETIC SPECTROMETER E.Syresin, B. Zalikhanov-DLNP, JINR R. Makarov-MSU.
NEEP 541 Ionization in Semiconductors - II Fall 2002 Jake Blanchard.
22 October 2009FCAL workshop, Geneve1 Polarization effects in the radiation damaged scCVD Diamond detectors Sergej Schuwalow, DESY Zeuthen On behalf of.
GERMANIUM GAMMA -RAY DETECTORS BY BAYAN YOUSEF JARADAT Phys.641 Nuclear Physics 1 First Semester 2010/2011 PROF. NIDAL ERSHAIDAT.
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS.
Accelerator Physics, JU, First Semester, (Saed Dababneh). 1 Principles of Spectrometry.
Alpha and Beta Interactions
Ionization Detectors Basic operation
Scintillation Detectors
Introduction to semiconductor technology. Outline –4 Excitation of semiconductors Optical absorption and excitation Luminescence Recombination Diffusion.
Gamma ray interaction with matter A) Primary interactions 1) Coherent scattering (Rayleigh scattering) 2) Incoherent scattering (Compton scattering) 3)
Chapter 5 Interactions of Ionizing Radiation. Ionization The process by which a neutral atom acquires a positive or a negative charge Directly ionizing.
Title Light Detectors. Characteristics  Sensitivity  Accuracy  Spectral Relative Response(R( ))  Absolute Sensitivity(S( ))  Signal-to-noise ratio.
Determination of activity of 51 Cr source on gamma radiation measurements V.V.Gorbachev, V.N.Gavrin, T.V.Ibragimova, A.V.Kalikhov, Yu.M.Malyshkin,A.A.Shikhin.
Medical applications of particle physics General characteristics of detectors (5 th Chapter) ASLI YILDIRIM.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
1.1 What’s electromagnetic radiation
President UniversityErwin SitompulSDP 3/1 Dr.-Ing. Erwin Sitompul President University Lecture 3 Semiconductor Device Physics
Nishina School Sep/29-Oct/8/2009 Scintillator 渡邊康 Wata-nabe Yasushi.
Life always offers you a second chance. It’s called tomorrow.
Neutrinoless double beta decay (0  ) CdTe Semico nductor Band gap (eV) Electron mobility (cm 2 /V/s) Hole mobility (cm 2 /V/s) Density (g/cm 3.
Interactions of Ionizing Radiation
3/2003 Rev 1 II.3.5 – slide 1 of 23 IAEA Post Graduate Educational Course Radiation Protection and Safe Use of Radiation Sources Session II.3.5 Part IIQuantities.
Scintillators – General Characteristics
Elettra Sincrotrone Trieste
Instrument Parameters in WDXRF
Spectrometry of high energy gamma ray
Scintillation Counter
Radiation Sensors Radiation is emission if either particles or electromagnetic rays from a source. Particles are usually nuclear particles which can be.
X-ray detectors single photon detectors
PARTICLE DETECTORS I recently joined the IAEA.
Computed Tomography (C.T)
Gain measurements of Chromium GEM foils
Presentation transcript:

Gamma rays detectors 1) Comparative characteristics of detectors 2) Scintillation detectors 3) Semiconductor detectors 4) Crystal diffraction spectrometers BGO crystals from Novosibirsk Energie [keV] Počet HPGe Plastic NaI(Tl) CZT NaI(Tl) detector for satellite Fermi Comparison of natural background spectra detected by different types of detectors (taken from presentation of ORTEC company) HPGE detectors of satellite INTEGRAL

Comparative characteristics of detectors Sensitivity – capability to produce measurable signal for given type of particle and energy. Depends on: 1) cross-section of ionization reactions, photon reactions, ... 2) detector mass, its construction 3) detector noise 4) thickness and type of material surrounding sensitive detector volume Response – relation between particle energy and detector output (total charge or current amplitude of pulse). Response function F(E,E´) - spectrum S(E´) of monoenergetic beam is observed by detector as complicated function. Usually near to Gauss function with  tail to lower energies. Measured distribution of pulse amplitude P(E): E – energy at measured spectrum, E´- initial energy Time response – time of detector signal creation Pulse form – detector signal shape leading edge, declining (even more components) fast component, slow component

Death time – time needed for creation and analysis of detector signal. 1) detector is not sensitive 2) Detector is always sensitive – „pile-up“ is created – amplitude superposition Assumption: death time τ is constant: Case 1 (death time is not extended): Real number of particles: NS = mT = k + mkτ m – real count rate, T – time of measurement, k – number of registered cases Dead time and its influence Real count rate: Case 2 (death time is extended): Distribution of intervals t between signal arrival: then probability that t > τ: and relation between registration number k and real count rate m is:

Detection efficiency – ratio between number of detected particles and number of particles emitted by source – absolute efficiency. It consists of intrinsic efficiency εVNI and geometrical efficiency (acceptance) εGEO : ε = εVNI·εGEO Standard – line 1332 keV of 60Co It is determined also relatively – detector comparably to standard (NaI(Tl) with sizes 7.627.62 cm) in given geometry ( - distance 25 cm) εNaI = 0,12 % Ratio between peak and Compton background – for gamma ray detectors – ratio between maximal amplitude in peak 1332 keV and mean value in the region 1040 – 1096 keV Energy resolution – the smallest distinguishable energy difference ΔE between two near energies. Monoenergetic beam → ideally δ-function – practically peak with finite width (mostly Gauss shape). Resolution is presented in the form of full width at half maximum – FWHM). Relative resolution ΔE/E in [%] is also used. differences from Gauss shape are given by: FWTM – width in 1/10 of high FWFM – width 1/50 of high Gauss: FWTM/FWHM = 1.82 FWFM/FWHM = 2.38 Also other distributions, asymmetries, electrostatic spectrometer – Lorentz shape

FWHM – energy resolution: (It is valid for scintillation, semiconductor, gas detectors) Number of created charge carriers, photons …: where eS is mean energy needed for creation of charge carrier or photon Ionization and deexcitation – Poisson distribution → standard deviation: Relation between FWHM and σ for Gauss shape: FWHM = 2.35 ·σ Detector absorbing only part of energy: Deposited energy E freely fluctuate → Poisson distribution is valid: Detector absorbing total energy (photon detectors): Deposited energy is fixed finite value → Poisson is not valid, correction introduces Fano: where F – Fano correction Relative energy resolution:

properties of electronic …. Comparison of absolute and relative resolution for scintillation and semiconductor detectors FWHM value is influenced by another factors: absorption of charge carriers, photons properties of electronic …. In the case of independent contributions: (ΔE)2 = (ΔETN)2 + (ΔEPN)2 + (ΔEELEK)2 + … Time resolution – the smallest resolvable time difference – definition similar to energy resolution Space resolution – the smallest resolvable space difference – definition similar to previous

Tolerance to radiation damages – irradiation → damages, crystal lattice defects, bugs less sensitive – liquid and gas detectors more sensitive – scintillation and mainly semiconductor detectors Shape after irradiation Gauss shape before irradiation Illustration of downgrade of HPGE detector of INTEGRAL satellite after irradiation (A.Thevenina report) Detectors work in strong radiation field During experiments on accelerators Sometime gradual regeneration is possible, HPGe detector is possible to regenerate after warming

Scintillation detectors Scintillation detector: 1) Scintillator 2) Photomultiplier + magnetic shielding (or photodiode) 3) Base Ionization radiation passage → excitation of atoms a molecules deexcitation → energy → light production - luminescence Information: 1) Energy 2) Time – they are fast 3) Particle identification from pulse shape Fluorescency – fast energy conversion to light 10-8s Phosphorescency - delayed energy conversion to light μs – days – longer λ Properties of photomultipliers, photodiodes, avalanche photodiodes – see literature

Discharge has exponential behavior: One-component Binary: τR – fast component, τP – slow component Example of signal shape of binary scintillator Požadavky na scintilator: 1) High efficiency of excitation energy conversion to fluorescent light 2) Conversion should be linear 3) Transparency for fluorescence light (light emission should be in different range than light absorption 4) Fluorescent spectrum should be compatible with photomultipliers 5) Short decay constant 6) It should have good optical properties and easily machinable 7) Index of refraction should be near to n = 1.5 (glass) – good crossing passage of light to photomultiplier

Organic scintillators: 1) Organic crystals – anthracene, stilbene 2) Liquid organic scintillators very resistive against radiation damage, measured radioactive substance can be part of detector 3) Plastic scintillators – very fast τ ~ 2 ns, NE111: τleading edge = 0.2 ns and τ = 1.7 ns lower Z → small σ for photoeffect, Compton scattering dominates, addition of heavy element admixture (Pb) → increasing of photopeak, decreasing of light output Inorganic scintillators: are slower, higher Z → more suitable for gamma radiation, CsI(Tl), NaI(Tl) (is hygroscopic), BGO (Bi4Ge3O12), BaF2,PbWO4 BGO, BaF2, PbWO4 very useful for high energy gamma BaF2 very fast (fast component), two components ρ [g/cm3] eS [eV] τ [ns] Anthracene ~0,8 60 30 Plastic (NE111) ~1.2 100 1.7 NaI 3.67 25 230 BGO 7.13 300 300 BaF2 4.89 125 0.6 (fast c.) 600 (slow k.) Limiting theoretical resolution, without inclusion of influence of electronic and charge carrier trapping Fano coefficient is for scintillators F ~ 1

BaF2 crystals of photon spectrometer TAPS TAPS and ALICE photo materials BaF2 crystals of photon spectrometer TAPS ultraviolet components λ=220nm and λ=310 nm Crystal PbWO4 of high energy photon spectrometer of project ALICE, blue λ= 420 nm and green λ= 480-520 nm

Semiconductor detectors Very common: HPGe (earlier Ge(Li)) – need liquid nitrogen cooling Si – for low energy range Newer and up to now more special: CdTe, HgI2, CdZnTe (CZT) – up to now for lower energies, cooling is not necessary, eS ~ 4.4 eV Ge, Si – four valence electrons – electron release (its transposition from valence to conduction band) → creation of hole and free electron Impurity with 3 valence electrons – electron recipient → → hole predominance → semiconductor of p type Impurity with 5 valence electrons – electron donor → → predominance of electrons → semiconductor of n type Ge(Li) detector – 1012 impurity atoms per cm3 HPGe – 109 impurity atoms per cm3 WWW pages of W. Westmaier Prevention of thermal production of electron-hole pairs → temperature 77 K Capture and recombination on dislocations and impurities HPGe detector placed inside Shielding lead box

Basic semiconductor properties: for T=77 K Si Ge Z 14 32 Atomic mass 28.09 72.60 Density ρ [g/cm3] 2.33 5.33 Energy gap [eV] 1.1 0.7 Electron mobility μe[ 104cm2/Vs] 2.1 3.6 Hole mobility μd [104cm2/Vs] 1.1 4.2 eS [eV] 3.76 2.96 Fano coefficient F ~ 0.09 ~ 0.06 ve = μe·E vd = μd·E Voltage on detector more than 1000 V Small pulses → necessity of preamplifier: detector → premaplifier → amplifier → ADC → analyzer, computer Position sensitive HPGe segmented detectors are developed by LLNL (Californian University) its WWW Technical details – see recommended literature

Parameters for 60Co line with energy 1332 keV Relative efficiency To the standard (NaI(Tl)): 10 – 70 % (εNaI = 0.12 % εGEO ~ 0.58 % εVNI ~ 20 % ) peak/compton: 1:30 až 1:60 Resolution: FWHM 1.7 – 2.3 Peak shape: FWTM/FWHM ~2.0 (Gauss 1.82) FWFM/FWHM 2.65 – 3.00 (Gauss 2.38) ΔEΣ2 = ΔETN2 + ΔEELEK2 + ΔEPN2 ΔETN – intrinsic uncertainty (carrier creation) ΔEELEK – uncertainty given by electronic ΔEPN – uncertainty given by electron and hole recombination and capture Low energies – Si and thin HPGe detectors, beryllium window High energies - HPGe with large volume, aluminum window longer (6 μs) or shorter (2 - 4 μs) time constant of amplifier Limiting theoretical resolution, without inclusion of influence of electronic Energy measurement accuracy up to order eV Massive practical usage → many commercially produced types and models

of energy standard determination Crystal diffraction spectrometers Consist of 1) crystal lamina (quartz crystal, calcite) 2) detector of X- and gamma rays Characteristic angles influenced on line width φZ – angle of source visibility from crystal φK – angle of collimator visibility from source φC – angle of diffraction line FWHM ΘB – Bragg angle Crystal lattice Source Collimator φK φZ φC ΘB Angular FWHM φ of intensity afterwards is (for small values of all angles in radians) φ2 ≈ φZ2 + φK2 + φC2 Detector Different crystal geometries: Plane crystals Curved crystals Different configuration: with one crystal Θ = ΘB with two crystals Θ = 2ΘB R – angular resolution Example of measurement accuracy: 169Yb → 169Tm line 63 keV – E = 63.12080(16) keV Necessity to include influence of nucleus reflection during photon emission and accuracy of energy standard determination