1 Nexans Cabling Solutions Fibre solutions for fast deployment Joost Grillaert.

Slides:



Advertisements
Similar presentations
© DIAMOND Headquarters / F-3000 r & rs / / 1 WERE WELL CONNECTED F-3000 r & F-3000 rs connectors.
Advertisements

R&M Fiberliner LAN / WAN applications R&Measynet.
Industrial Segment Alternative Power Generation
Amphenol Outdoor Connectors
Cabling UTP AND FIBER CABLING. Structured Cabling Infrastructure Mounted and permanent Allows patching Comfort that infrastructure is OK Components: Information.
1 R&M FO Patch Panels Splice Version The convincing way to terminate fibers.
© DIAMOND SA / / 1 MT-RJ CONNECTOR SYSTEM Duplex SFF for FTTx applications.
Chapter 8 Optical fiber splicing Attenuation curve for silica optical fiber.
MFS, MPO 4/8/12-Fiber connectors and Fan-Out assemblies.
© DIAMOND SA / / 1 Alberino CRA Alberino fixing system for modular constructions within industrial Mennekes housing.
FibreTec ODF Solutions Ordering Guide for The Patch & Patch/Splice Tray FODF-1U-P 1.Production Description 2.Ordering Information 1.FODF-1U-P Tray 2.Splice.
Fiber Optic Construction & Termination Jeff Hite University of Oregon/NSRC This document is a result of work by the Network Startup Resource.
Start here >> Network IQ Training Manual Chapter 4 - Fibre Optic Hardware.
Copyright 2008 Kenneth M. Chipps Ph.D. How to Terminate a Corning Unicam Connector Last Update
FiberNext LLC 41 Locke Road, Concord, NH MPO Switch Exclusively by FiberNext Rev_12/30/13.
R&Mfoxs Venus-FXXL-SCM Patrick Schilter, PM Central Office & Wall boxes August 2013.
© DIAMOND SA / / 1 DMI DIAMOND Micro Interface Detachable miniature optical interface for multiple usage.
Evolis card printer Dualys Product Presentation © 2003 Evolis. All rights reserved. We reserve the right to make changes without prior notification. All.
Qualified Partner Program R&M FO patch panels for LAN applications Felice Guarna, Training Program Manager Wetzikon, January 2006.
Qualified Partner Program FO Terminal Outlets Felice Guarna, Training Program Manager Wetzikon, September 2005.
40/100 Gb/s Ethernet Over Multi-mode Optical Fiber Planning for Infrastructure Readiness.
L1 => L2 Optical Network Patch Panel Update Tim Durkin STFC RAL 03/04/2014.
111 © 2002, Cisco Systems, Inc. All rights reserved. Trim out phase steps Cutting cables to length Labeling cables Dressing cables Terminating cables Installing.
Fiber-Optic Communications
FIBER OPTIC CABLE CONSTRUCTION
Content :  Indoor fiber optic cables  The benefits of indoor Fiber Optic Cable  The features of indoor Fiber Optic Cable  Tight-Buffered Cable  Consists.
1 Fiber Optics LIGHT CRIMP TERMINATIONS USING THE PRENTIUM KIT.
Qualified Partner Program R&Mfreenet fiber - LAN F.O. installation cable Felice Guarna, Training Program Manager Wetzikon, January 2006.
1 Fiber Optics FIBER OPTIC PATCH PANELS. 2 Fiber Optics Just like our copper cable plant the fiber cable plant incorporates many of the same hardware.
Fiber Optic Connections Piotr Turowicz Poznan Supercomputing and Networking Center 9-10 October 2006.
Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006.
Fiber Optic Basics. Why fiber? – Low loss & low signal spreading means greater distances between expensive repeater stations. – Less weight means easier.
Sida 1 N3S Nexans Space Saving Solution High Density ODF system.
INSTALL THE TRANSMISSION LINE By Mohd Nasir bin Said.
© DIAMOND SA / / 1 MAS Multipurpose Adapter System.
© Fluke NetworksVisiFault L&L June 2004 VisiFault Visual Fault Locator (VFL) New tool traces fiber, verifies continuity and polarity, helps find breaks.
Fiber Optics FUSION SPLICING.
1 Fiber Optics EPOXY/POLISH TERMINATIONS. 2 Fiber Optics A WORD OF CAUTION WHEN TERMINATING FIBER. THERE ARE SPECIFIC SAFETY PROCEDURES THAT NEED TO BE.
Die Cast – Nickel Die Cast – Black Metalized Plastic Black Plastic Grey Plastic Plastic - Assorted Colors –Available only on 972 Series.
Certified Fiber Optic Training
Copper Solutions. Nexans Cabling Solutions 04 September LANmark5 EVO Based LANmark 6 EVO Based Screened & Unscreened LANmark 6A EVO Based, Screened.
1 Nexans Cabling Solutions Easy and reliable migration from fast to faster to100G.
Page 1 © 2008 IDEAL INDUSTRIES IDEAL Micro OTDR Oktober 2008 Konstantin Hüdepohl.
1 Nexans Cabling Solutions NVT Software update 2012 – NVT 3.2 Didier Willems Project Design & Support Department Manager.
© ABB Month DD, YYYY | Slide 1 MG3 Thermal transfer printer Martinez, Marketing, 17/05/2013.
© DIAMOND SA / / 1 ALBERINO Solution. © DIAMOND SA / / 2 E-2000™ ALBERINO Solutions Product description A single and robust component for.
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
Fiber Joints Fibers must be joined when
HD Flex ™ Fiber Cabling System
13 June 2013Laurent Roy Optical Fibers / Electronics Upgrade -Fibers need for Upgrade -> Installation ? -Two techniques possible for multi fibers installation.
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
Fiber connections of QIE cards in UX5 Ulrich Heintz 4/23/20151.
A for Military Ships August What is A? A is a system of: –tube assemblies –tube connectors –tube management closures –fibre bundles –fibre management.
PowerIT Air Insulated Cubicle Uniswitch
CERN EN-EL Cabling and Optical Fibre Section CERN EN-EL Cabling and Optical Fibre Section Mini Workshop, Simao Machado, EN/EL/CF.
Network infrastructure for CERN DataCenter HEPiX Fall 2015.
ANCIT WORKSHOP Torino, March 1998 Optical Network Construction in Customer Premises by Sadaaki TAKANO NTT Access Network Systems Laboratories.
V. Bobillier1 Cable installation status.
Outside Plant Fiber Optics
1 Rick Dallmann Session: DB 1.1 Designing Next-Generation SAN/Storage Optical Infrastructure Why Low Link (Budget) Loss is Critical.
Solutions – 1 – opticonx.com FOR DATA CENTERS AND STORAGE AREA NETWORKS Solutions Xtreme8™ is Opticonx’s Base-8 cabling solution for easy migration.
Optical performance measurements of various fibre connections
Optimizing the Data Centre Physical Layer in the Era of the Cloud
Introduction to Computers
Fiber Optic Connectors, Splices, and Tools
Guidelines for Fiber Optic Design and Installation
FTTH PRODUCTS INTRODUCTION
Computer Networks Topics: Twisted Pair and Fiber Optic Cable
HYC CO., LTD. 清远市亿源通光电科技有限公司 品质连接信任 11 Understanding MPO Fiber Cables and Polarity MPO stands for Multi-Fiber Push On. MPO fiber patch.
Presentation transcript:

1 Nexans Cabling Solutions Fibre solutions for fast deployment Joost Grillaert

2 Agenda  Patch panels Snap in patch panels Preloaded patch panels for datacenters  Pre-terminated assemblies  MPO concept Components Polarity  Comparison between preterm and MPO

3 Nexans Cabling Solutions Patch Panels

4 Patch Panel solutions for LC and SC adaptors  Standard offering: Unloaded LANmark-OF Snap In sliding panel Snap In Adaptors allow to save 1-2 min for each adaptor installation  LANmark-OF offering for data centres: Preloaded for fast installation in data centres. High density LANsense upgradable after installation with upgrade kit

5 Benefits Snap In Sliding Panel  Sliding mechanism  Can be populated as required  For splicing or direct termination  Up to 48 fibres in 1 HU Panel

6 Snap-in adaptors Benefits: Allows quick and easy installation without screws Saves 1-2 minutes per connector! Standard coupler Plastic Adapter Piece

7 Snap-in adaptors LC Adaptor MT-RJ Adaptor DSC Adaptor SC Adaptor Snap-in concept

8 Sliding patch panel

9 New patch panels for data centers  Preloaded with adaptors, spindles and splicing cassettes Splice protections and pigtails to be ordered seperately  Adaptors fixed between 2 metal plates  Movable front plate  Advanced fibre management with spindles  Density High density: 96 LC or 48 SC Medium density: 48 LC or 24 SC  Availability: June 2008

10 Preloaded patch panels for data centers White Black High density 96 LC 48 SC Medium density 48 LC 24 SC

11 N-number codification  N441.2W96LCMMS W: White 96 connections LC connector MM: multimode (beige) S: spindle

12 Nexans Cabling Solutions Preterm for data centres

13 Pre-Terminated Fibre assemblies overview Fanout legs Grommet Pulling eye Protection tube

14 Pulling system  Factory installed  Use cable’s internal strength members  Easy to assemble or disassembled  Applicable pulling forces 6 cores cable: 100 daN 12/24 cores cable: 140 daN

15 Product details  High quality LANmark-OF cables  Standard construction: Tight-buffer  High quality LANmark-OF fibre: SM – 62,5 – 50µ OM3  Range of cores:  Any cable length available – 1m step  High performing connectors  LC, SC, MTRJ, ST, …  Fan-out leg size: 2.0mm or 900µ

16 100% Controlled product  100% tested and documented Insertion loss Return loss  Serial number on each assembly for faster and easier traceability

17 High performing connectors  LC connector compliant with IEC specifications  SC connector compliant with IEC specifications  PC ceramic ferrule (Zirconia)  Boots: maximum length: 30mm  Color: Beige

18 Link loss improved  Better connector performances higher number of connection within the link Values for 50µm Multimode Fibre with 2000MHz.KM Bandwidth  Up to 13 connectors over 100m  Cutting edge advantage for Data centres/SAN’s

19 Benefits 100% Tailor made solution Very short manufacturing lead-time (2-3 weeks) Very fast installation times No cable preparation necessary No cable or connector scrap No installer termination errors No field termination or splicing No need of consumables and toolkits No specialised termination training required Factory quality solutions: Fully tested and documented Improved link loss budget

20 Installation of Pre-Terminated Assemblies Factory installed and tested connectorisation …… requires field installing into patch panels

21 Nexans Cabling Solutions MPO solution

22 MPO concept MPO adaptor Multiple fibre Push On 12 LC

23 Components of MPO system MPO cassette 12 LC, 24 LC or 12 SC MPO patch panelMPO round trunk cable

24 MPO cassettes N441.2M24LC3N441.2M12LC3 N441.2M12SC3N441.2MBP

25 MPO Patch Panel  4 cassettes in 1 patch panel High density: 96 LC Easier handling: 48 LC  Fibre guide for patch cords  Labelling front

26 MPO-MPO trunk round cable  Developed specifically for data centers  Easy to install  No preferential bending as opposed to ribbon cable  50% Smaller than ribbon cables Diameter of 2,3 mm  Allows easier polarity method  12 fibers

27 MPO polarity Problem description Right  Left T1  R12 R2  T11 T11  R2 R12  T1 R T LC MPO MPO Cassettes MPO LC R T Unwanted side change

28 MPO polarity NCS solution: method C Right  Left T1  R2 R2  T1 T11  R12 R12  T11 R T LC MPO MPO Cassettes MPO LC R T

29 MPO polarity Polarity method C  Method C Selected by Nexans Uses one type of MPO-cassettes Uses one type of patch cords Does not require flipping of cassette  Method C requires pair flip in trunk cable Easier to implement with round MPO trunk cable Key upKey downPair flip

30 Benefits/challenges in data centers of various methods Preterm and MPO implemented in data centers

31 Conclusions  New preloaded patch panels for data centers  Pre-terminated assemblies interesting solution for data centers  MPO products introduced