Factors affecting the X-Ray output

Slides:



Advertisements
Similar presentations
Producing an X-ray Exposure
Advertisements

Technical Aspects: the machine the image
Advanced Biomedical Imaging Lecture 3
Chapter 11 Prime Factors.
Chapter 7 Radiographic Image Formation and Exposure Factors.
{ Projection Radiography Chapter 5 (in more detail)
E XPOSURE FACTORS : Contrast, Density, Image Quality, technique math 1.
Chapter 6 Control of Secondary and Scattered Radiation.
Dental X-ray Machine 118 Radiology.
FRCR: Physics Lectures Diagnostic Radiology
ACVR Artifacts Artifacts of Diagnostic Radiology
Analyzing the Image Density. Density Overall blackening of the image.
Prime Exposure Factors II By Professor Stelmark. Primary Factors The primary exposure technique factors the radiographer selects on the control panel.
X-RAY TUBE & EXPOSURES INVERSE SQ LAW CIRCUITRY
Radiation Physics II.
Medical Imaging X-Rays I.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
ELECTROMAGNETIC RADIATION
8.1 PRODUCTION AND CHARACTERISTICS OF X-RAYS
X-Ray Production & Emission
RAD 354 Chapt 7 X-ray Production The primary purpose of an x-ray tube is to accelerate electrons across the tube and suddenly stop them in the target to.
X-Ray Production & Emission
Reference Reading Chapter 2: pp  X-rays are produced within the dental x-ray machine  The x-ray machine can be divided into 3 study areas.
Quality Control Rad T 110.
Resident Physics Lectures Christensen, Chapter 6Filters George David Associate Professor Department of Radiology Medical College of Georgia.
Week one Chapters one and two
P RIMARY E XPOSURE FACTORS : Contrast, Density, Image Quality, technique math 1.
Quality Control.
Ch. 2 – Anatomy of the X-ray Machine
HABIS X-RAY PRODUCTION AND EXPOSURE FACTORS X-RAY PRODUCTION AND EXPOSURE FACTORS PREPARED BY PREPARED BY Dr fahad albadr radiology chairman radiology.
Resident Physics Lectures
Prime Exposure Factors 1
Chapter 2 The X-ray Beam.
RAD 254 Chapter 15 Radiographic Technique 4 primary exposure factors are: kVp, mA, time, distance.
CT Instrumentation and X-ray system
Exposure Factors or Prime Factors
X-ray emission spectra
Radiation Quality Chapter 4. X-ray Intensity Intensity: the amount of energy present per unit time per unit area perpendicular to the beam direction at.
Elsevier items and derived items © 2009 by Mosby, Inc., an affiliate of Elsevier Inc. X-Ray Emission Chapter 9.
PRINCIPLES OF TECHNIQUE AND EXPOSURE
RAD 354 Chapt. 8 X-ray emission
X-rays discovered in 1895 by Wilhem Roentgen Roentgenology – Branch of medicine dealing with x-ray or gamma rays in diagnosis and treatment. Radiology.
Determining Radiation Intensity
Medical Equipment Technology Department 1 Introduction to Biomed. Imaging Systems Lecture No.5-6 Dr. Yousif Mohamed Y. Abdallah.
Image Quality and Patient Dose. X-ray tube design - basic principles Electrons generated by thermionic emission from a heated filament (cathode) Accelerating.
RTT 425 Radiation Therapy Physics Radiation Quality, Chapter 4 From Stanton and Stinson: Applied physics for Radiation Oncology.
Tube Exposure Factors Math Technique Contrast and Density
Sergeo Guilbaud School of Radiologic Sciences
Radiology Steps in radiation production Kilovoltage and voltage.
RTEC A - WEEK 4 GENERAL SCIENCE REVIEW & X-RAY PRODUCTION IN THE TUBE
X-ray tube.
 Make and type of x-ray machine  Incoming line voltage  Kilovoltage  Milliamperage and exposure time  Focal film distance/source-imagine distance.
An early x-ray by Wilhem Rontgen
Radiology. The Cathode… Provides a source of electrons and directs the electrons towards to anode. The cathode has a coiled wire filament that emits electrons.
8 November 1895, produced and detected electromagnetic radiation in a wavelength range today known as X- rays or Röntgen rays, electromagnetic radiationwavelengthX-
Radiology Milliaperage. The beam of radiation we use in dentistry may be described in two ways: 1.Quality = penetrating ability - energy of the photon.
Chapter 9 Concepts you already know!!! INTENSITY = ROENTGENS AKA EXPOSURE l mAs and mR proportional? l kVp and mRproportional? l Distance and mRproportional?
Exposure Factors or Prime Factors
Khan, The Physics of Radiation Therapy, Ch7
X-RAY PRODUCTION AND EXPOSURE FACTORS
Part No...., Module No....Lesson No
X-Radiation.
Stacy Kopso, M.Ed., RT(R)(M)
Factors Effecting the Production
Principles of Image Production
Exposure Factors Chapter 4
Resident Physics Lectures (Year 1)
Resident Physics Lectures (year 1)
CHAPTER 7 X-RAY PRODUCTION.
Resident Physics Lectures (Year 1)
Presentation transcript:

Factors affecting the X-Ray output Dr. Nahla Nagy

What is intensity? Quantity Quality Intensity: Total energy contained in the beam (product of quality and quantity of x-ray photons) per unit area per unit time Quantity is the number Quality is the energy Together = the intensity of the X-ray

X-Ray Quantity X-ray quantity: measure of the number of x-ray photons in the useful beam. AKA x-ray output, intensity, or exposure Unit Roentgen (R) Directly affected by: Miliamperage-second (mAs) Kilovoltage (kVp) Distance (d)

X-Ray Quality X-ray quality: : measurement of the penetrating ability of the x-ray beam. Describes the distance an x-ray beam travels in matter. High energy x-ray photons travel farther in matter- more penetrating Numerically represented by the Half-value layer (HVL).

Factors Affecting Intensity Factors affecting intensity of x-ray beam actually affect no. of photons or penetration power of photon in x-ray beam. Target Material X-ray Tube Current (Miliamperage- mA) Tube voltage (kVp) Exposure time (s) Filtration Collimation Source to film distance

Target Material Determines efficiency of X-ray production Higher the atomic number- greater will be the efficiency of the production of x rays

X-ray Tube Current (mA) Produced by flow of electrons from their point of origin (filament) to the anode (target) of x-ray tube A change in filament voltage of about 5% result in 20- 30% change in x-ray tube current (mA) Hotter filament emits more electrons and adds electrons to the current electrons (mA) across the x-ray tube Increased mA means increase in quantity of electrons available to hit the target -that results an increase in the quantity of x-ray photons

mA is directly proportional to quantity of x-ray beam y axis = number of X-ray photons (quantity) x axis = energy of X-ray photons (quality) Area under the curve = intensity (product of quantity and quality)

Exposure Time (s) 1) Increasing time (s) heats filament for a longer time. 2) Longer the filament is heated more electrons are produced. 3) Increase in quantity of electrons

mAs (miliamperage seconds) mA multiplied by s mA and exposure time have a direct effect on the quantity of X-ray photons produced mAs is the product of mA (current) and exposure time (seconds); determine total number of x-ray photons produced The miliamperage required for a given exposure is inversely proportional to the exposure time mAs Rule: Original mA x Original time = New mA x New time

(original mA x original time = new mA x new time) Example In an examination controls are set for 10 mA and time is 30 sec, what is the mAs? 10mA x 30s = 300 mAs If mA is increased to 15, how much time is required to produce same mAs? (original mA x original time = new mA x new time) 10mA x 30s = 15mA x Xs            X = 20 sec.

Tube Voltage (kVp) Increasing kVp increases potential difference between the cathode and anode. kVp controls the speed of the electrons, increasing kVp will increase the number of x ray photons produced per unit time Shorter wavelength and more penetrating photons of x-ray radiation are produced (i.e., increases speed) Increase in quantity and quality of x-rays. Quantity = number (speed) Quality = energy

Increasing kVp, increases both number and energy of x-rays Drastic increase in intensity (area under the graph)

Tube Voltage (kVp) Intensity is proportional to (kVp)2 In dentistry to maintain same density :rule of thumb Increase of 15 kVp requires halving the exposure time Decrease of 15 kVp requires doubling the exposure time If kvp doubled from 50 to 100-x ray intensity increases by factor of four

Filtration Filtration is the removal of low energy, less penetrating photons from x-ray beam by placing filter in the path of x- ray beam. Filters are aluminum sheets placed at the end of the tube where x-rays exit

Filtration Types of Filtration Inherent-X-ray tube and its housing Added-Sheets of metal placed in the path of the beam The patient

Filtration No. of photons decreas Mean (average) energy of photons increase Maximum energy is unchanged Effects quality and quantity of x-ray beam

Half value Layer Definition: The thickness of an absorber required to reduce the number of x-ray photons passing through it by one half of its original value In dentistry : 69 kVp/ below         HVL of 1.5mm Al 70-90 kVp               HVL of 2.5 mm Al

Collimation A collimator is a metallic barrier with an aperture in the middle used to reduce the size of the x-ray beam, thus, the volume of irradiated tissue within patient is also reduced Main Functions Protect the patient Decrease the scatter radiation

Collimation Reduces patient exposure Reduces scatter radiation Increases film quality

Round beam limiting device, 20 cm (8”) focus-film distance, 6 cm (2,36”) output field diameter.  Rectangular beam limiting device as an option to reduce patient’s exposure to radiation. www.jzimaging.com/SigmaBiomedics_Intraos_70.htm

Collimation Number of photons decreases Mean energy of photons is unchanged Maximum energy of the photons is unchanged

Source –film distance Inverse Square Law The x-rays of primary beam emerge from the protective tube housing not as parallel rays but as divergent rays Intensity of the x-ray beam decreases as the distance from the source increases Inverse Square Law The intensity of the X ray beam is inversely proportional to square of the source-film distance I1/I2 = (D2)2/(D1)2

Source –film distance Doubling the SFD distance ,exposure time will have to be increased by the factor of 4 to maintain the same density on the film

Inverse Square Law No of photons decreases Mean energy of photons is unchanged Maximum energy of the photons is unchanged

Review Factors affecting Quality kVp Factors affecting intensity Filtration Factors affecting intensity Tube voltage (kVp) Current (mA) exposure time (s) Filtration Collimation Source to film distance Factors affecting Quantity kVp mA Exposure time Filtration Collimation Distance

Thank You