Accredited Standards Committee C63® - EMC

Slides:



Advertisements
Similar presentations
Quantitative and Scientific Reasoning Standard n Students must demonstrate the math skills needed to enter the working world right out of high school or.
Advertisements

Conducted Immunity IEC
GTEM CABLE EMISSION STUDIES MEASUREMENT TECHNOLOGY LIMITED JUNE 29 TH 2010 Dr. Zaid Muhi-Eldeen Al-Daher Dr. Angela Nothofer Prof. Christos Christopoulos.
A Proposal for RF Coupling Experiments ANSI C63.19 Working Group Submitted for discussion by Stephen Julstrom February 3, 2008.
Chapter 13 Transmission Lines
A VISUAL AID TO PYROMETRY COMPLIANCE (A Guide To An Acceptable TUS Report) February 2010.
PH0101 Unit 2 Lecture 4 Wave guide Basic features
Chapter Fourteen: Transmission Lines
RTCA DO-160 Section 20 Working Group Billy M. Martin Cessna Aircraft.
1 SCHOOL OF COMPUTER & COMMUNICATIONS ENGINEERING EKT 341/4 ANTENNAS AND PROPAGATION Lecturer: En. Rosmizi bin Abd Rahim Dr. Mohd Faizal Bin Jamlos PLV:
SLIM JIM ANTENNA discussion
® 04/29/2002 CISPR 22, Amendment 1 Ferrite Clamps Ghery S. Pettit, NCE Intel Corporation Corporate Product Regulations.
Protection Values for VOR-Defined ATS Routes
Antennas Lecture 9.
CORRELATION BETWEEN RADIATED IMMUNITY AND COUPLING ATTENUATION
1 Seventh Lecture Error Analysis Instrumentation and Product Testing.
ESTeem Training Class Antenna Fundamentals. Decibels (dB) Used for all mathematical calculations in the radio world. – dB is a logarithmic number dB =10.
Radial Basis Function Networks
1 Cessna EME Lab Reverb Chamber Emissions Matthew Wills EME Lab Supervisor December 7th, 2004.
COLUMNS. COLUMNS Introduction According to ACI Code 2.1, a structural element with a ratio of height-to least lateral dimension exceeding three used.
Radio Interference Calculations
Antenna Design Tools VE3KL
Ch 8.1 Numerical Methods: The Euler or Tangent Line Method
Effect of Mutual Coupling on the Performance of Uniformly and Non-
Microwave Amplifier Design Blog by Ben (Uram) Han and Nemuel Magno Group 14 ENEL 434 – Electronics 2 Assignment
Chapter 9 Electromagnetic Waves. 9.2 ELECTROMAGNETIC WAVES.
1 Accredited Standards Committee C63 ® - EMC Subcommittee 1: Techniques and Developments Zhong Chen SC1 Chair
Fundamentals of Data Analysis Lecture 9 Management of data sets and improving the precision of measurement.
Oct. 16, 2006 Midterm Next Class Assignment #4 is Marked
Antenna Design and Link Engineering Pattern lobes Pattern lobe is a portion of the radiation pattern with a local maximum Lobes are classified as: major,
Device Noise Two figures of merit for noisy devices
Copyright 2005 International EMC Standards Activity 1 EMC International Standards Update CISPR SC A and I Activity Don Heirman Don HEIRMAN Consultants.
Lecture 16 In this lecture we will discuss comparisons between theoretical predictions of radiation and actual measurements. The experiments consider simple.
BICON / HYBRID COMPARISON Performed by members of the TCB Council ANSI C63 SC 1 April 18, 2012.
Sphere Standards and Standard Spheres Dr. Richard Young Optronic Laboratories, Inc.
Purpose This course discusses techniques for analyzing and eliminating noise in microcontroller (MCU) and microprocessor (MPU) based embedded systems.
USCEL Third Run EMI Round Robin Roland Gubisch Intertek.
A Critical Look at Standards and Specifications Colin Brench
1 Review from previous class  Error VS Uncertainty  Definitions of Measurement Errors  Measurement Statement as An Interval Estimate  How to find bias.
Electromagnetic Design of Broadband Antenna Feed Systems for the Northern Cross Radio Telescope (Bologna, Italy) Designed Broad Band Antenna Feed Systems.
Oct. 23, 2006 Midterm Marked. –Average: 73%. 6 below, 9 above –Answer Key posted: s/nten216/Tests/NTEN216_Midterm1WithAns.
FUNCTIONS AND MODELS 1. The fundamental objects that we deal with in calculus are functions.
TS9975 Konyang University 20 th July to 22 nd July 05.
© Copyright 2002 TEM Consulting, LP - All Rights Reserved Presentation To Portland & Seattle EMCS ChaptersRev – 04/25/02 - HSB Revision of ANSI C63.4 -
I.Introduction II. System Design B.E. Unks, N. A. Proite, D. D. Yavuz University of Wisconsin – Madison The above figure shows a block diagram of the apparatus.
NO ACTIVITY C SC1 - Oct 2011 PINS inactive Published 15 December 2009 (Reaffirmation of 1996 edition)
May FPGA Controlled Amplifier Module (FCAM) December 8, 2005.
Informations and comments on ECE-TRANS-WP.29-GRB e 1 Louis-Ferdinand PARDO (France) Transmitted by the expert from France Informal document GRB
Limits of space loss calculations. Near Field / Far Field Far field implies a plane wave. A plane wave is an asymptotic extrapolation of a spherical.
Doc.: t Submission September 2007 Anthony Maida, 3eTI, Inc.Slide 1 Recommendations for Comments on COAT Section Date: Authors:
4-2-2 Passive filters. Passive filters At the end of this topic you will be able to; recognise, analyse, and sketch characteristics for a low pass and.
Telecommunications JBCardenas © 1982 Com3 4Q1516 Antenna Design JBC © 198 v A2,2 Key design requirements 1.Undertake the theoretical computations of shapes.
Unit IV Ultrasonic examination of welds Foreword.
Antenna Basics.
ANTENNA THEORY : Analysis and design Third edition
DESIGN PARAMETRES AT BASE STATION Prittu Ann Thomas Roll no :14.
National Highway Institute 5-1 REV-2, JAN 2006 EQUIPMENT FACTORS AFFECTING INERTIAL PROFILER MEASUREMENTS BLOCK 5.
Establishing by the laboratory of the functional requirements for uncertainty of measurements of each examination procedure Ioannis Sitaras.
Piero Belforte, CSELT 1999: AEI_EMC_, EMC basics by Flavio Maggioni.
ANTENNA MEASUREMENTS Measurement of Radiation Pattern Gain
A Proposal for RF Coupling Experiments
International Africa University Faculty of Engineering Eight Semester
CReSIS Electromagnetic Anechoic Chamber at the University of Kansas
Accredited Standards Committee C63® - EMC
Recommendations for Comments on COAT Section
Open Rack Specification 2.1 Update
Recommendations for Comments on COAT Section
GSC: Standardization Advancing Global Communications
GSC: Standardization Advancing Global Communications
PH0101 Unit 2 Lecture 4 Wave guide Basic features
Presentation transcript:

Accredited Standards Committee C63® - EMC Draft C63.-5-201x Annex N Site-Specific Qualification Procedure for Hybrid Antennas (intended to be used for the making of ANSI C63.4-201x Final Compliance Measurements) Harry H. Hodes, NCE Principal EMC Engineer ACIL Corporation for EMC Proficiency Testing, Inc. [ACE-PT Inc.] 18 April 2012

Accredited Standards Committee C63® - EMC Summary of this Presentation Observations, Current Situation, & Problem-Requirement Statement Ground Rules for Selecting the Technical Approach Overall Technical Approach - Pre-requisites Dimensional, Frequency, and VSWR [Return Loss] Restrictions Required Equipment - Qualification Test Setup, Qualification Test Procedure, and Analysis of the Test Data Qualification Criteria (Pass/Fail Limits) Some Antennas that meet all of the Annex N Restrictions Some Antennas that do not meet all of the Annex N Restrictions.

Accredited Standards Committee C63® - EMC Observations - I EMC PT data strongly indicate that, in some cases, the use of hybrid antennas results in excellent, highly repeatable measurements. (Note: variations of +/- 5 dB or better from the “assigned value” have repeatedly occurred).

Accredited Standards Committee C63® - EMC Observations - II In contrast, EMC PT data also strongly indicate that, in some cases, the use of hybrid antennas has resulted in gross measurement errors. (Note: variations of +/- 23 dB from the “assigned value” have repeatedly occurred, in cases that were not obviously caused by test operator egregious error).

Accredited Standards Committee C63® - EMC Observations - III In contrast, EMC PT data strongly indicate that the use of biconical and LPDA antennas has resulted in much smaller gross measurement errors. (Note: variations of +/- 9 dB to +/- 12 dB from the “assigned value” have repeatedly occurred, in cases that were not obviously caused by test operator egregious error).

Accredited Standards Committee C63® - EMC Observations - IV Possible causes for these conflicting results: - Use of large or very large hybrids (especially in small semi-anechoic chambers at 3 m distances). some hybrids have an extremely high VSWR (> 500:1 or more, especially in the 30 MHz to 70 MHz range). every manufacturer of hybrid antennas uses a different BALUN design and a different arrangement of antenna elements. The coupling responses of each model of hybrid antenna will vary significantly with: test site size (i.e., 3 m, 5 m, or 10 m); test site style (e.g., non wx-protected OATS, partially wx-protected OATS, full wx- protected OATS, symmetric semi-anechoic chambers, non-symmetric semi-anechoic chambers, fully anechoic rooms); and, with varying RF Absorber floor laydown pattern and wall/ceiling treatments. Hybrid Antennas have a significantly greater calibration MU than biconicals and LPDAs (cf. CISPR 16-1-4:2010).

Accredited Standards Committee C63® - EMC Current Situation ANSI C63.4-2003: - Section 4.1.5.3 refers to ANSI C63.2-1996 for the list of acceptable antennas. ANSI C63.2-1996 contains the following broadband antennas for 30-1000 MHz (cf. Sections 15 and 15.5.4): biconical antenna, log periodic antenna, double-ridged guide horn. There is no mention of hybrid antennas. However, ANSI C63.2-1996 Section 15.5.4 further states that linearly polarized broadband antennas are allowed, with the biconical and log periodic as the recommended types. Since a hybrid is classified as a linearly polarized antenna, it is accepted provided it is calibrated using the latest edition of ANSI C63.5 or SAE-ARP- 958:1992, and, can be shown to be correlated with measurements made with a tuned dipole with an “acceptable” degree of accuracy. - Does NOT allow the use of hybrid antennas for making NSA measurements. (Note: only Roberts-type Tuned Dipoles, Biconicals, and LPDAs are allowed when making NSA measurements).

Accredited Standards Committee C63® - EMC ANSI C63.4-2009 Current Situation - I Table 1 does not include hybrid antennas. The intent of the ANSI C63.4-2009 maintenance team was to prohibit the use of hybrid antennas for making final compliance measurements. Notwithstanding this fact, ANSI C63.4-2009 states that CISPR 16-1-4:2007-02 is a normative reference. Per CISPR 16-1-4:2007-02, a broadband antenna may be used provided it meets the requirements in CISPR 16-4-2:2007-02 Clause 4.4.1.3 (30-300 MHz) and Clause 4.5.2 (300-1000 MHz). CISPR 16-4-2:2007-02 Clause 4.4.1.3 refers to the CISPR 16-4-2:2007-02 Clause 4.5.2 requirements, which are summarized as: 1) Linearly polarized antenna, 2) Main lobe and reflected lobe within 1 dB; i.e. broad beam or pointed antenna, 3) Antenna with a 2:1 SWR at receiver, 4) Antenna calibration to meet the requirements in 4.1 of CISPR 16-1-4:2007-02. The above is subject to the ANSI C63.4-2009 Clause 4.5.3 requirement that an antenna is acceptable “provided that the measurement can be correlated with that made with a tuned dipole with an acceptable degree of accuracy”.

Accredited Standards Committee C63® - EMC ANSI C63.4-2009 Current Situation - II In addition, ANSI C63.4-2009 also states that ANSI C63.2-2009 is a normative reference. ANSI C63.2-2009, in turn, specifies an undated reference to CISPR 16-1-1 as its only normative reference, and notes that the sensor specifications in Table 1, Note 2 of CISPR 16-2-1, CISPR 16-2-2, and CISPR 16-2-3 Measurement Procedures are applicable. CISPR 16-2-3 Clause 7.3.7 states that antennas need to conform to CISPR 16-1-4. In CISPR 16-1-4:2010-04 Clause 4.5.1 it is stated that: “The antenna shall be a dipole-like antenna designed to measure the E-field, and the free-space antenna factor shall be used. The antenna types include: a) tuned dipole antennas, whose element pairs are either straight rods or conical in shape; b) dipole arrays such as the log-periodic dipole array (LPDA) antennas, comprising a series of staggered sets of straight rod elements; c) and hybrid antennas.” However, CISPR 16-1-4:2010-04 Clause 4.5.3 also imposes conditions that are summarized here: - The antenna must be linearly polarized, - The antenna must meet balance test of Clause 4.5.4 for frequencies below 200 MHz, - The antenna must meet the conditions for beam width described in Clause 4.5.3(c), - The antenna must have a Return Loss of 10 dB or more, The antenna calibration factors must meet the Clause 4.1 requirements. Regardless, the use of hybrid antennas is subject to the ANSI C63.4-2009 Clause 4.5.3 requirement that an antenna is acceptable “provided that the measurement can be correlated with that made with a tuned dipole with an acceptable degree of accuracy”.

Accredited Standards Committee C63® - EMC ANSI C63.4-2009 Current Situation - III In addition, ANSI C63.4-2009 also states that ANSI C63.2-2009 is a normative reference. ANSI C63.2-2009, in turn, specifies an undated reference to CISPR 16-1-1 as its only normative reference, and notes that the sensor specifications in Table 1, Note 2 of CISPR 16-2-1, CISPR 16-2-2, and CISPR 16-2-3 Measurement Procedures are applicable. CISPR 16-2-3 Clause 7.3.7 states that antennas need to conform to CISPR 16-1-4. In CISPR 16-1-4:2010-04 Clause 4.5.1 it is stated that: “The antenna shall be a dipole-like antenna designed to measure the E-field, and the free-space antenna factor shall be used. The antenna types include: a) tuned dipole antennas, whose element pairs are either straight rods or conical in shape; b) dipole arrays such as the log-periodic dipole array (LPDA) antennas, comprising a series of staggered sets of straight rod elements; c) and hybrid antennas.” However, CISPR 16-1-4:2010-04 Clause 4.5.3 also imposes conditions that are summarized here: - The antenna must be linearly polarized, - The antenna must meet balance test of Clause 4.5.4 for frequencies below 200 MHz, - The antenna must meet the conditions for beam width described in Clause 4.5.3(c), - The antenna must have a Return Loss of 10 dB or more, The antenna calibration factors must meet the Clause 4.1 requirements. The above is subject to the ANSI C63.4-2009 Clause 4.5.3 requirement that an antenna is acceptable “provided that the measurement can be correlated with that made with a tuned dipole with an acceptable degree of accuracy”.

Accredited Standards Committee C63® - EMC ANSI C63.4-2009 Current Situation - IV - ANSI C63.4-2009 does NOT allow the use of hybrid antennas for making NSA measurements. (Note: only Roberts-type Tuned Dipoles, Biconicals, and LPDAs are allowed when making NSA measurements).  Note that CISPR 16-1-4:2010-04 specifically allows (but does not recommend) the use of hybrid antennas for making NSA measurements (cf. Clause 5.4.2.3.1 Note 2).

Accredited Standards Committee C63® - EMC ANSI C63.4-2009 Current Situation - V Unfortunately, if you are a user of hybrid antennas, and, you want to perform final compliance tests on products, none of this really is of any practical help because: - almost no one has the required data needed to show compliance with all of the requirements of CISPR 16-1-4:2010-04 Clause 4.5.3; - the CISPR 16-4-2:2007-02 Clause 4.5.2 requirement to meet the “antenna having a 2:1 SWR at the receiver” will be difficult or impossible unless a “pad” attenuator AND a pre-amplifier are used (which will create many other problems); - there is no clear statement in ANSI C63.4-2009 of what “an acceptable degree of accuracy” actually is (w.r.t. measurement correlation with those made with a tuned dipole).

Accredited Standards Committee C63® - EMC Problem-Requirement Statement What is required is a technically reasonable, practical, test-site-specific qualification test procedure that can be used to objectively determine whether or not a given hybrid antenna is acceptable (or not acceptable) for use in making final compliance measurements on products in accordance with ANSI C63.4.  “technically reasonable” means that appropriate hybrid antenna designs should be acceptable. “practical” means that the procedure can be accomplished at reasonable cost with regularly-available test equipment. “objectively determined” means that the acceptance criteria are based on the actual measurement uncertainties of the actual qualification test procedure, and not on arbitrary criteria.

Accredited Standards Committee C63® - EMC Ground Rules for Selecting the Technical Approach - I Must contain a definition of what a “hybrid antenna” is for the purpose of the Qualification Test Procedure. Achieve a reasonable balance between best technical practices and the concerns of economic operators. Qualification Test Procedure must be both test-site specific and antenna-specific. Use the “funnel approach” to minimize the lab workload. Funnels are wide at the top and narrow at the bottom. The notion was to eliminate antennas that are obviously unacceptable from consideration at the outset so as to avoid wasting time and money on futile testing.

Accredited Standards Committee C63® - EMC Ground Rules for Selecting the Technical Approach - II Acceptance Criteria must be based upon the actual measurement uncertainties of the actual Qualification Test Procedures used, not on an arbitrary (e.g., +/- 1 dB) “acceptability” criteria. Hybrid antennas are not permitted to be used for Test Site Validation measurements.  Note that CISPR 16-1-4:2010 allows, but does not prefer the use of hybrid antennas for Test Site Validation measurements.

Accredited Standards Committee C63® - EMC Overall Technical Approach - I Pre-requisites: Site must meet NSA / VSA [30 MHz – 1000 MHz] (Section N.1) Site must meet SVSWR [1 GHz – 18 GHz] (if hybrids are to be used > 1GHz) (Section N.1) Hybrid Antennas must be designed for Emissions measurements (dual use emissions/immunity hybrids can be used if the “bat-wing” or “grid” elements are removed). (Section N.3) Dimensional, Frequency and VSWR [Return Loss] Restrictions Restricts maximum Hybrid Antenna dimensions to 1.55 max length x 1.5 m width x 1.5 m height. (Section N.3) Restricts minimum nominal frequency of operation of Hybrid Antennas to 30 MHz, and the maximum nominal frequency of operation of Hybrid Antennas to 6 GHz. (Section N.3) From 30 MHz to 200 MHz, the free-space VSWR of the Hybrid Antenna must be 10:1 or better; if not 10:1 or better, an impedance matching “pad” attenuator must be installed on the antenna so as to make it 10:1 or better. (Section N.3)

Accredited Standards Committee C63® - EMC Overall Technical Approach - II Required Equipment (Section N.4.2): the Hybrid Antenna to be investigated, and if necessary, its Hybrid Impedance-Matching Pad Attenuator [HAIMP]. Free-Space Antenna Factors (obtained per ANSI C63.5) must be available for the hybrid. quantity = 2 biconical antennas, each having the same nominal balun impedance (i.e., both must have 200 Ohm baluns or both must have 50 ohm baluns). One bicon is to be designated as the transmit antenna, and the other as the “reference” (receive) bicon. Free-Space Antenna Factors (obtained per ANSI C63.5) must be available for the “reference” (receive) Bicon. quantity = 2 nominally identical LPDA antennas. One LPDA is to be designated as the transmit antenna, and the other as the “reference” (receive) LPDA. Near-Free-Space Antenna Factors (obtained per ANSI C63.5) must be available for the “reference” (receive) LPDA. quantity = 2 nominally DRG Horn antennas. One DRG Horn is to be designated as the transmit antenna, and the other as the “reference” (receive) DRG Horn. Free-Space Antenna Factors (obtained per ANSI C63.5) must be available for the “reference” (receive) DRG Horn. [Note: applicable only if the hybrid to be investigated is to be used above 1 GHz].

Accredited Standards Committee C63® - EMC Overall Technical Approach - III Required Equipment (Continued) (Section N.4.2): Test Site to be investigated (i.e., OATS or Semi-Anechoic Chamber [SAC] or Fully Anechoic Room [FAR]) Lab’s Antenna Mast and Controller, and lab’s standard coaxial range cable(s) EMI Receiver or Spectrum Analyzer-based EMI Measurement System. Tripod or Mast (or other antenna mounting system) for transmit antennas Quantity = two 10 dB impedance matching “pad” attenuators are required. One 10 dB attenuator is required to be installed on the input connector of each transmit antenna, and the other 10 dB attenuator is required to be installed on the input connector of the EMI Receiver or Spectrum Analyzer-based EMI Measurement System. Signal Generator(s) covering the frequency range from 30 MHz to the maximum frequency of the hybrid that is to be investigated (but not exceeding 6 GHz). High-quality coaxial cable(s) to connect the Signal Generator(s) to the 10 dB Pad installed on the Transmit Antennas.

Accredited Standards Committee C63® - EMC Overall Technical Approach (Section N.4.3) - IV Test Setup: a) Place the transmit biconical antenna in horizontal polarization at a height of 1 m at the center of the turntable. Install a 10 dB attenuator on the input connector of the transmit biconical antenna. b) Place the receiving biconical antenna on the antenna mast in horizontal polarization at a height of 1 m at a distance of 3 m, as measured from the reference point of the transmit biconical antenna to the reference point of the receive biconical antenna. Do NOT use an attenuator on the output connector of the receiving biconical antenna. Use a high quality coaxial cable to connect the transmit biconical antenna (with the 10 dB attenuator installed) to a signal source. Use the coaxial cable that is used for regular product testing to connect the receiving antenna to the EMI receiver or spectrum analyzer via a 10 dB attenuator that shall be installed directly onto the input port of the EMI receiver or spectrum analyzer.

Accredited Standards Committee C63® - EMC Overall Technical Approach (Section N.4.3) - V Test Setup & Test Procedure: c) Scan the receiving biconical antenna from 1 m to 4 m while simultaneously scanning or stepping the EMI Receiver or Spectrum Analyzer over the frequency range 30 MHz to 200 MHz. Use a maximum resolution bandwidth of 120 kHz. Use either linear frequency steps with maximum step-size equal to one-half of the chosen resolution bandwidth, or use a linear scan. Ensure that the received signal is at least 20 dB above the system noise floor. Record the maximum received signal levels. The results recorded are the reference values for the two biconical antennas at 3 m in horizontal polarization and are designated as S21,BB3H. Without moving the transmit biconical antenna, remove the receiving biconical antenna and replace it with the hybrid antenna to be qualified, such that the reference point on the hybrid is at the 3 m distance, as measured from the reference point of the transmit biconical antenna. d) If required in accordance with N.3 c), install the impedance matching "pad" attenuator at the output connector of the hybrid antenna. Reconnect the receiving coaxial cable, and repeat step c), making certain that the EMI Receiver or Spectrum Analyzer settings are not changed. The results are the “antenna under test” [AUT] values of the transmit biconical antenna and the receiving hybrid antenna at 3 m in horizontal polarization. These results are designated as S21,BH3H.

Accredited Standards Committee C63® - EMC Overall Technical Approach (Section N.4.3) - VI Test Data Analysis: Compute the reference and AUT horizontally polarized field strength measurement results (in dBV/m) as follows: Compute the difference between the reference and AUT horizontally polarized field strength results (in dB) as follows: Compare the E3mH results obtained with the acceptance criteria given in N.5.1 a).

Accredited Standards Committee C63® - EMC Overall Technical Approach (Section N.4.3) - VII Repeat the above procedure and computations with the biconical antennas and the hybrid antenna under test in vertical polarization at the 3 m measurement distance. Denote the reference and AUT vertically polarized field strength measurement results (in dBV/m) as follows: Compute the difference between the reference and AUT horizontally polarized field strength results (in dB) as follows: Compare the E3mV results obtained with the acceptance criteria given in N.5.1 a).

Accredited Standards Committee C63® - EMC Overall Technical Approach (Section N.4.3) - VIII Repeat the above process using LPDAs and the hybrid antenna under test at the 3 m measurement distance, as measured from the reference point of the transmit LPDA to the reference point of the receive LPDA and the reference point of the hybrid, respectively. Compute the reference and AUT horizontal and vertical polarization field strength measurement results (in dBV/m) as follows: Compute the differences between the reference and AUT horizontally and vertically polarized field strength results (in dB) as follows: Compare the E3mH and E3mV results obtained with the acceptance criteria given in N.5.1 b).

Accredited Standards Committee C63® - EMC Overall Technical Approach (Section N.4.3) - IX If necessary, repeat the above procedure using DRG horn antennas and the hybrid antenna under test at the at the 3 m measurement distance, as measured from the reference point of the transmit DRG Horn to the reference point of the receive DRG Horn and the reference point of the hybrid, respectively. Compute the reference and AUT horizontal and vertical polarization field strength measurement results (in dBV/m) as follows: Compute the differences between the reference and AUT horizontally and vertically polarized field strength results (in dB) as follows: Compare the E3mH and E3mV results obtained with the acceptance criteria given in N.5.1 c).

Accredited Standards Committee C63® - EMC Overall Technical Approach (Section N.4.3) - X If applicable, repeat the entire process using the biconicals, LPDAs, DRG horns and the hybrid antenna under test at the 10 m measurement distance. (Alter the subscript notation used in equations accordingly, perform the required computations, and compare the results with the applicable acceptance criteria given in N.5.2 a) or b) or c)

Accredited Standards Committee C63® - EMC Acceptance Criteria (Section N.5.1, 3 m distance) N.5.1 a): In the frequency range 30 MHz to 200 MHz, for a given polarization, at the 3 m measurement distance, on a specific test site, a hybrid antenna shall be deemed acceptable for use in making final compliance measurements if the difference in results of measurement performed in accordance the procedures in the previous slides at each polarization meets the following requirements: - the results of the E3mH calculations are less then or equal to  2.5 dB at all measured frequencies in the range 30 MHz to 200 MHz (inclusive); and, - the results of the E3mV calculations are less then or equal to  2.5 dB at all measured frequencies in the range 30 MHz to 200 MHz (inclusive).   NOTE: The above criteria are based upon the Expanded Uncertainty Values for a k=2 Coverage Factor that were computed for the exact measurement procedure (at the 3 m measurement distance) detailed in Section N.4.3.

Accredited Standards Committee C63® - EMC Acceptance Criteria (Section N.5.1, 3 m distance) N.5.1 b): In the frequency range 200 MHz to 1000 MHz, for a given polarization, at the 3 m measurement distance, on a specific test site, a hybrid antenna shall be deemed acceptable for use in making final compliance measurements if the difference in results of measurement performed in accordance the procedures in the previous slides at each polarization meets the following requirements: - the results of the E3mH calculations are less then or equal to  2.9 dB at all measured frequencies in the range 200 MHz to 1000 MHz (inclusive); and, - the results of the E3mV calculations are less then or equal to  2.9 dB at all measured frequencies in the range 200 MHz to 1000 MHz (inclusive).   NOTE: The above criteria are based upon the Expanded Uncertainty Values for a k=2 Coverage Factor that were computed for the exact measurement procedure (at the 3 m measurement distance) detailed in Section N.4.3 .

Accredited Standards Committee C63® - EMC Acceptance Criteria (Section N.5.1, 3 m distance) N.5.1 c): In the frequency range 1000 MHz to 6000 MHz, for a given polarization, at the 3 m measurement distance, on a specific test site, a hybrid antenna shall be deemed acceptable for use in making final compliance measurements if the difference in results of measurement performed in accordance the procedures in the previous slides at each polarization meets the following requirements: - the results of the E3mH calculations are less then or equal to  3.2 dB at all measured frequencies in the range 1000 MHz to 6000 MHz (inclusive); and, - the results of the E3mV calculations are less then or equal to  3.2 dB at all measured frequencies in the range 1000 MHz to 6000 MHz (inclusive).   NOTE 1: The above criteria are based upon the Expanded Uncertainty Values for a k=2 Coverage Factor that were computed for the exact measurement procedure (at the 3 m measurement distance) detailed in Section N.4.3. NOTE 2: A hybrid antenna that satisfies the above criteria may be used up to its maximum operating frequency or to 6000 MHz, whichever is less.

Accredited Standards Committee C63® - EMC Acceptance Criteria (Section N.5.2, 10 m distance) N.5.2 a): In the frequency range 30 MHz to 200 MHz, for a given polarization, at the 10 m measurement distance, on a specific test site, a hybrid antenna shall be deemed acceptable for use in making final compliance measurements if the difference in results of measurement performed in accordance the procedures in the previous slides at each polarization meets the following requirements: - the results of the E3mH calculations are less then or equal to  2.4 dB at all measured frequencies in the range 30 MHz to 200 MHz (inclusive); and, - the results of the E3mV calculations are less then or equal to  2.4 dB at all measured frequencies in the range 30 MHz to 200 MHz (inclusive).   NOTE: The above criteria are based upon the Expanded Uncertainty Values for a k=2 Coverage Factor that were computed for the exact measurement procedure (at the 10 m measurement distance) detailed in Section N.4.3.

Accredited Standards Committee C63® - EMC Acceptance Criteria (Section N.5.2, 10 m distance) N.5.2 b): In the frequency range 200 MHz to 1000 MHz, for a given polarization, at the 10 m measurement distance, on a specific test site, a hybrid antenna shall be deemed acceptable for use in making final compliance measurements if the difference in results of measurement performed in accordance the procedures in the previous slides at each polarization meets the following requirements: - the results of the E3mH calculations are less then or equal to  2.9 dB at all measured frequencies in the range 200 MHz to 1000 MHz (inclusive); and, - the results of the E3mV calculations are less then or equal to  2.9 dB at all measured frequencies in the range 200 MHz to 1000 MHz (inclusive).   NOTE: The above criteria are based upon the Expanded Uncertainty Values for a k=2 Coverage Factor that were computed for the exact measurement procedure (at the 10 m measurement distance) detailed in Section N.4.3 .

Accredited Standards Committee C63® - EMC Acceptance Criteria (Section N.5.2, 10 m distance) N.5.2 c): In the frequency range 1000 MHz to 6000 MHz, for a given polarization, at the 10 m measurement distance, on a specific test site, a hybrid antenna shall be deemed acceptable for use in making final compliance measurements if the difference in results of measurement performed in accordance the procedures in the previous slides at each polarization meets the following requirements: - the results of the E3mH calculations are less then or equal to  3.2 dB at all measured frequencies in the range 1000 MHz to 6000 MHz (inclusive); and, - the results of the E3mV calculations are less then or equal to  3.2 dB at all measured frequencies in the range 1000 MHz to 6000 MHz (inclusive).   NOTE 1: The above criteria are based upon the Expanded Uncertainty Values for a k=2 Coverage Factor that were computed for the exact measurement procedure (at the 10 m measurement distance) detailed in Section N.4.3. NOTE 2: A hybrid antenna that satisfies the above criteria may be used up to its maximum operating frequency or to 6000 MHz, whichever is less.

Accredited Standards Committee C63® - EMC How were the Acceptance Criteria determined? A set of Measurement Uncertainty calculations were developed specifically for the test processes specified in Section N.4. The MUC calculations were mechanized using four Microsoft Excel® 2010 workbooks, with three sheets per workbook for each of two measurement distances (i.e., 3 m and 10 m). Four spreadsheets: bicon frequency range (30-200 MHz) at 3 m & 10 m; Liberty Labs & ETS-Lindgren; Four spreadsheets: LPDA frequency range (200-1000 MHz) at 3 m & 10 m; Liberty Labs & ETS-Lindgren; Four spreadsheets for the DRG Horn frequency range (1 GHz – 6 GHz) at 3 m & 10 m; Liberty Labs & ETS-Lindgren.

Accredited Standards Committee C63® - EMC Example Spreadsheet

Accredited Standards Committee C63® - EMC Qualification Interval (Section N.6) For any given hybrid antenna used at a given measurement distance, on a specific test site, the qualification process detailed in N.4 and N.5 shall be performed when the hybrid antenna is first taken into service at the given measurement distance on the specific test site, and subsequently at intervals of not more than three years. If damage to or degradation of the antenna is known or suspected to have occurred, a re-qualification is to be performed as well.

Accredited Standards Committee C63® - EMC Some Hybrid Antennas that meet all of the Annex N Restrictions Schaffner (Chase) CBL 6116C Schaffner (Chase) CBL 6112B Teseq CBL 6112D Teseq CBL 6111D Electrometrics 6917C-1 ETS-Lindgren 3143B ETS-Lindgren 3149 Sunol JB1 Sunol JB2 Sunol JB6 Schwarzbeck VULB 9162

Accredited Standards Committee C63® - EMC Some Antennas that do NOT meet all of the Annex N Restrictions Electrometrics 6917B-1 (does not meet the minimum low frequency restriction) Schaffner CBL 9140A (does not meet the dimensional restrictions and the minimum frequency restrictions) Teseq CBL 6143A (does not meet the “Emissions only/Dual Use” restriction) EMCO 3142B (does not meet the dimensional restrictions and the minimum frequency restrictions) EMCO 3142C (does not meet the dimensional restrictions and the minimum frequency restrictions) ETS-Lindgren 3142D (does not meet the dimensional restriction) Rohde & Schwarz HL562 (does not meet the dimensional restriction) A.H. Systems SAS-521-2 (does not meet the minimum frequency restrictions)