X RAY SPECTROSCOPY.

Slides:



Advertisements
Similar presentations
24.6 Diffraction Huygen’s principle requires that the waves spread out after they pass through slits This spreading out of light from its initial line.
Advertisements

Objectives By the end of this section you should:
General Characteristics of Gas Detectors
Radiation Detection ionization chambers (dosimeters, pulse chambers, particle track chambers) scintillation detectors semiconductor detectors photographic.
Production of X-rays (1)
Instrumental Chemistry
Optical sources Lecture 5.
Saeedeh Ghaffari Nanofabrication Fall 2011 April 15 1.
Geiger-Muller detector and Ionization chamber
Experimentally, the Bragg law can be applied in two different ways:
6. Atomic and Nuclear Physics Chapter 6.4 Interactions of matter with energy.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Internal – External Order We described symmetry of crystal habit (32 point groups) We also looked at internal ordering of atoms in 3-D structure (230 space.
X-Ray Crystallography The most important technique for mineralogy The most important technique for mineralogy Direct measurement of atomic arrangement.
What disperses radiation into component wavelengths?
X-radiation. X-rays are part of the electromagnetic spectrum. X-radiation (composed of X-rays) is a form of electromagnetic radiation. X- rays have a.
Radiation Physics II.
Molecular Fluorescence Spectroscopy
Atomic Emission Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Yat Li Department of Chemistry & Biochemistry University of California, Santa Cruz CHEM 146C_Experiment #3 Identification of Crystal Structures by Powder.
Atomic X-Ray Spectroscopy Chapter 12 X-ray range  Å to 100 Å Used  0.1Å to 25 Å.
Computed Tomography RAD309
Atomic Absorption Spectroscopy (AAS)
Instrumental Chemistry Chapter 12 Atomic X-Ray Spectroscopic.
X-Ray Diffraction ME 215 Exp#1. X-Ray Diffraction X-rays is a form of electromagnetic radiation having a range of wavelength from nm (0.01x10 -9.
Lecture 11  Production of Positron Emitters, Continued  The Positron Tomograph.
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
Instruments for Radiation Detection and Measurement Lab # 3 (1)
Polarization Polarization is a characteristic of all transverse waves.
1 Components of Optical Instruments, Cont… Lecture 7.
Atomic Emission Spectroscopy
Components of Optical Instruments, Cont… Lecture 8.
Chapter 7 X-Ray diffraction. Contents Basic concepts and definitions Basic concepts and definitions Waves and X-rays Waves and X-rays Crystal structure.
Lesson 5 Conditioning the x-ray beam
Principles of instrumentation Prepared by: Ibtisam H. AlAswad Reham S. Hammad.
Photon detection Visible or near-visible wavelengths
Chapter 12 Atomic X-Ray Spectroscopy
Unknown at first, these photons from innershell transitions have played a vital role in materials analysis.
Chem X-ray Crystallography X-ray crystallography is an experimental technique that exploits the fact that X-rays are diffracted by the periodic.
Tools for Nuclear & Particle Physics Experimental Background.
Scanning Electron Microscope (SEM)
The Particlelike Properties of Electromagnetics Radiation Wei-Li Chen 10/27/2014.
Chapter 24 Wave Optics. General Physics Review – waves T=1/f period, frequency T=1/f period, frequency v = f velocity, wavelength v = f velocity, wavelength.
X-Ray Diffraction Dr. T. Ramlochan March 2010.
Last time we defined a crystal as a solid containing translational symmetry. The directions of translation can be used to from a unit cell. A primitive.
PHYS 430/603 material Laszlo Takacs UMBC Department of Physics
Interference in Thin Films, final
LIGHT and MATTER Chapters 12 and 13. Originally performed by Young (1801) to demonstrate the wave-nature of light. Has now been done with electrons, neutrons,
Spectrophotometry.
Unit 12: Part 1 Physical Optics: The Wave Nature of Light.
The electron.  An indivisible quantity of charge that orbits the nucleus of the atom.
Medical Image Analysis Interaction of Electromagnetic Radiation with Matter in Medical Imaging Figures come from the textbook: Medical Image Analysis,
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
X-ray diffraction and minerals. Is this mineral crystalline?
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
Colorimeters or photometers
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
LIGHT and MATTER Chapters 11 & 12. Originally performed by Young (1801) to demonstrate the wave-nature of light. Has now been done with electrons, neutrons,
Chapter V Radiation Detectors.
Colorimeters or photometers
Spectrophotometer Dr . S. Jayakumar.
Chapter 3. Components of Optical Instruments
Instrument Parameters in WDXRF
Radiation Detectors : Detection actually means measurement of the radiation with its energy content and other related properties. The detection system.
Scintillation Counter
Colorimeters OR photometers
SPECTROPHOTOMETRY Applied Chemistry.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Radhabai Kale Mahila Mahavidhyalaya, Ppt. name:- x-Ray techniques
Presentation transcript:

X RAY SPECTROSCOPY

Introduction X-rays are a part of electromagnetic spectrum. X-rays have a wavelength in ranges of 0.01nm to 10nm.70-200pm for (AP). Produced by the deceleration of high-energy electrons. Electronic transition of electrons in the inner orbitals of atoms.

X RAY CHARACTERSTICS ABSORBTION X rays give information about the absorbing material just. Like other regions of the electromagnetic spectrum X rays are absorbed by matter and degree of absorbtion is determined by the nature and amount of absorbing material.

FLUORESCENCE Fluorescence emission of X-rays enables to identify and measure heavy elements. It is used for quantitative and qualitative determination of heavy elements DIFFRACTION Diffraction of x rays is used in analysis of crystalline materials with high degree of accuracy and specificity.

INSTRUMENTATION FOR X-RAY SPECTROSCOPY Components for X-ray spectroscopy are : X-ray generating equipment (X-ray tube) Collimator Monochromators detectors

X-Ray Tube Determining the energy of the X-Ray 100KV! Controlling the intensity of X-Ray

(1) X-Ray Tube (2) Collimators X-rays can be generated by an X-ray tube. X-rays tube is a vacuum tube that uses a high voltage to accelerate the electrons released by a hot cathode to a high velocity. The high velocity electrons collide with a metal target, the anode, creating the X-rays. (2) Collimators A collimator is a device that narrows a beam of particles or waves. Narrow mean to cause the directions of motion to become more aligned in a specific direction (i.e., collimated or parallel). Collimation is achieved by using a series of closely spaced ,parallel metal plates or by a bundle of tubes ,0.5 or less in diameter.

Monochromator Need of Monochromator Types of Monochromator Working of Filters Filter v/s Monochromator Working of diffraction grating Advantages of monochrome X-Rays

Need of Monochromator Monochromator crystals partially polarize an unpolarized X-ray beam The main goal of a Monochromator is to separate and transmit a narrow portion of the optical signal chosen from a wider range of wavelengths available at the input. Monochromators

Types of Monochromator Metallic Filter Type Diffraction grating type

Working of Filters Filters exploit the X-ray absorption edge of the particular element. At wavelengths longer than the absorption edge (i.e. just above the edge), the absorption of the X-rays is considerably less than for wavelengths shorter than the absorption edge (i.e. just below the edge) as shown for nickel metal:

Working of Filters The absorption edge of nickel metal at 1.488 Å lies between the Kα (λ = 1.542 Å) and Kβ (λ = 1.392 Å) X-ray spectral lines of copper. Hence nickel foil of an appropriate thickness can be used to reduce the intensity of the Cu Kβ X-rays as shown:

Choice of filter metal The choice of filter material depends upon the choice of anode material in the X-ray tube as shown in the following table: Anode Cu   Co Fe Mo Cr Filter Ni Mn Zr V

Laboratory X-ray Filters The beam passes through the top filter which in this case is a nickel foil. Alternative metal foils can be set by rotation of the filter housing to the appropriate position One position on the filter housing is left open for the case when a filter is not required.

Limitations of Filter X-ray filters were used to reduce the unwanted white radiation from the X-ray source and to eliminate (as much as possible) the Kβ radiation. The drawback of filters is that the background radiation is still high and that the transmitted radiation is still not very monochromatic.

Working of diffraction grating Source (A) Entrance slit (B) Collimator(C) Grating (D) Another mirror (E) Exit slit (F)

Working of diffraction grating

Advantages of monochrome X-Rays Improved resolution Minimizing sample damage Improved signal to noise ratio Analyze of small samples Multispotting on samples Simplified data processing

X-ray Detectors Solid State Detectors Scintillation Detectors Gas-filled Detectors

Solid State Detectors X-ray

Solid State Detectors The charge carriers in semiconductor are electrons and holes. Radiation incident upon the semiconducting junction produces electron-hole pairs as it passes through it. Electrons and holes are swept away under the influence of the electric field, and the proper electronics can collect the charge in a pulse.

Scintillation Detector + - Scintillator Photo Cathode Focusing cup Dynodes HV Resistor e-

Scintillation detectors Scintillation detectors consist of a scintillator and a device, such as a PMT(Photomultiplier tubes), that converts the light into an electrical signal Consists of an evacuated glass tube containing a photocathode, typically 10 to 12 electrodes called dynodes, and an anode Electrons emitted by the photocathode are attracted to the first dynode and are accelerated to kinetic energies equal to the potential difference between the photocathode and the first dynode

Scintillation detectors When these electrons strike the first dynode, about 5 electrons are ejected from the dynode for each electron hitting it These electrons are attracted to the second dynode, and so on, finally reaching the anode Total amplification of the PMT is the product of the individual amplifications at each dynode If a PMT has ten dynodes and the amplification at each stage is 5, the total amplification will be approximately 10,000,000 Amplification can be adjusted by changing the voltage applied to the PMT

Gas-filled detectors

Gas-filled detectors A gas-filled detector consists of a volume of gas between two electrodes, with an electrical potential difference (voltage) applied between the electrodes Ionizing radiation produces ion pairs in the gas Positive ions (cat-ions) attracted to negative electrode (cathode); electrons or anions attracted to positive electrode (anode) In most detectors, cathode is the wall of the container that holds the gas and anode is a wire inside the container

Geiger Mueller Counter Battery or High Voltage Resistor (-) Cathode + - (+) Anode e-

Geiger Mueller Counter GM counters also must contain gases with specific properties Most common type of detector Electrical collection of ions When the gas amplification factor reaches 108, the size of the output pulse is a constant, independent of the initial energy deposit. In this region, the Geiger- Mueller region, the detector behaves like a spark plug with a single large discharge. Simple cheap electronics Energy dependence Large dead times, 100-300µs, result No information about the energy of the radiation is obtained or its time characteristics.

X-ray Diffractometer Diffraction is a phenomena of bending of light around the corners of an obstacle ,when the size of an obstacle is of the order of wavelength of light. Wavelength of X-rays is of the order of few angstroms (10^-10m), same as inter-atomic distance in crystalline solids. Thus, X-rays can be diffracted from minerals which are crystalline and have regularly repeating atomic structures. Every crystalline substance will scatter the X-Rays in its own unique diffraction pattern. According to Bragg's law n = 2d Sin where d= distance between similar atomic planes in mineral (inter-atomic spacing  = angle of diffraction = wavelength n= an integer – 1,2,3.. etc (order of diffraction) A diffractometer is a measuring instrument for analyzing the crystallographic structure of a material from the scattering (diffraction) pattern produced when a beam of radiation or particles (such as X-rays) interacts with it.

X-ray Diffractometer A typical diffractometer consists of a source of radiation, a monochromator to choose the wavelength, collimator to make the beam parallel, a sample and a detector. An x-ray diffractometer illuminates a sample of material with x-rays of known wavelength. A strip of X-Ray film is mounted in circular position around the sample. The undeviated central beam passes out through a hole E cut in the film strip P. Diffracted beam falls on the film at various points like d1, d2, d3 etc. Intensities of the diffraction peaks are proportional to the fraction of the material in the mixture.

X-ray Fluorescence Spectrometry Re-emission of light of different wavelength is called fluorescence. Advantage of fluorescence detection over absorption is greater sensitivity. Fluorescence is more selective then absorption due to fact that all molecule that fluoresce must absorb, but not all molecules that absorb necessarily fluoresce. XRF is capable of measuring elements from beryllium (Be) to uranium (U). XRF is a powerful tool for qualitative and quantitative determination of heavy metal.