Chapter 16 Lesson Goal After completing this lesson, the student shall be able to operate different types of fire detection, alarm, and suppression systems.
OSHA Office of Training and Education
Fire Protection Systems
State Fire Marshal Question and Answer Session with the Louisiana Automatic Fire Alarm Association March 19, 1999.
Chapter 16 Lesson Goal After completing this lesson, the student shall be able to operate various fire detection, alarm, and suppression systems and operate.
Buildings and Structures 2 Fixed Installations Aim To provide students with information to allow them to recognise the types of fixed fire protection.
Fire protection systems
Unit 3 Fire Suppression Section 1 Detection and Alarm Systems.
Wet Sprinkler Systems Identifying components of, and inspection and testing procedures.
Water Based Sprinkler Systems 2 major different types of water sprinkler systems Wet pipe system Dry pipe system.
Effectiveness of Sprinkler Systems
Fire Detection and Suppression Chapter 7 Special Extinguishing Systems.
Chapter 12 Systems and Equipment for Fire Protection.
N.F.P.A. 13R Justin Bohlmann FIR-204.
4/15/2017 7:34 AM Fire Sprinkler Systems Prepared by Thomas Bartsch Chief Fire Inspector (ret) Former Chief of Department, Valley Stream, NY © 2007.
CVFD Training – Water Supply SFFMA Training Objectives: –
Automatic Sprinkler System. Importance of Sprinklers First line of protection – small fires Enhanced protection Business protection – less interruption.
AUTOMATIC SPRINKLERS.
Spray Finishing Operations/Spray Booth March 9, 2009.
FIRE SAFETY & SUPPRESSION C ERT Unit 2. Fires at USC  Several major fires at Fraternities, some with injuries  Occasional fires in laboratories  Birnkrant.
Means of Egress and Fire Protection. 2 Objectives Understand Alarms and Warning Devices Know the location of Exits and Exit Routes Understand the RACE.
FIREFIGHTER I LESSON 15. SPRINKLER SYSTEM DESIGN AND OPERATION Series of sprinklers arranged to automatically distribute enough water to extinguish or.
Copyright © Center for Systems Security and Information Assurance Lesson Seven Physical Security.
3-1 NFIRS 3 Structure Fire Module. 3-2 ObjectivesObjectives The participants will be able to: –describe when the Structure Fire Module is to be used.
Chapter 9. Please read chapter 9.  Please review, know and understand the terms related to fire protection page 284.  Know the Classifications of.
Chapter 12 Protective Systems. Introduction Protective systems help guard lives and property Detection systems detect presence of fire and alert occupants.
Physical Security Chapter 9.
Automatic Sprinkler Systems
Intermediate SFFMA Objectives: – Hrs received.
Fire Detection, Alarm, and Suppression Systems
Chapter 12 Protective Systems. Introduction Protective systems help guard lives and property Detection systems detect presence of fire and alert occupants.
Module C Sprinkler systems (4-20)
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
EGRESS AND FIRE PROTECTION
13 Search and Rescue. 2 Objectives (1 of 2) Define search and rescue. Describe the importance of scene size- up in search and rescue. Describe search.
HVACR311 – Electrical for Refrigeration International Mechanical Code Relating to Refrigeration.
Fire Department Hydraulics
HVAC523 Basic Subsystems.
FIRE SAFETY Introduction and Unit Overview The role of CERTs in fire safety:  Put out small fires.  Prevent additional fires.  Shutoff utilities 
Means of Egress and Fire Protection
© 2008 Delmar, Cengage Learning Property Security, Emergency Response, and Fire Protection Systems Chapter 13.
CHAPTER 12 Copyright © 2007 Thomson Delmar Learning 12.1 Protective Systems.
Search and Rescue.
Means of Egress and Fire Protection. Introduction Fires and explosions kill more than 200 and injure more than 5,000 workers each year There is a long.
Fire Protection Systems Chapter 6. Fire Protection Systems Most of the time you will work with an electrical engineer or fire-protection designer to coordinate.
Fire No institution is immune from fire. Flood damage can be dried out and restored, stolen property has a chance of being recovered; damage from fire.
Exit Routes and Fire Protection
Unit 2: Fire Safety and Utility Controls
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
Presented by John Lewandowski and Mike Larabel Inspection, Testing, and Maintenance of Kitchen Hood Systems Michigan Fire Inspectors Society Winter Educational.
FIRE SAFETY & SUPPRESSION C ERT Unit 2. The Red Cross responded to 74,000 disasters last year and 93% were fires.
Hot Work Permit Osan AB Fire Emergency Services.
13 Search and Rescue.
Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
CITY OF HARARE EMERGENCY SERVICES
Fire Safety.
SERVICES, LLC 1 1.
FIRE SAFETY & SUPPRESSION
What Library Staff Should Know About Fire Safety
AUTOMATIC SPRINKLERS.
Fire Safety for MSO, Residents, Medical Students and Nursing Students
Fire Safety for MSO, Residents, Medical Students and Nursing Students
Fire Prevention Safety Department
Firefighting equipment
Fire Safety and Utility Controls
Sprinkler Systems: Review and Response Considerations
Bella Vista Fire Department Procedures on Sprinkled Buildings
Presentation transcript:

CVFD Training – Fire Protection Systems SFFMA Training Objectives: 13-01.01 – 13-01.05

Functions of Fire Detection, Alarm, Suppression Systems To notify occupants of facility to take necessary evasive action to escape dangers of hostile fire To summon organized assistance to initiate or assist fire control activities (Continued) Firefighter I

Functions of Fire Detection, Alarm, Suppression Systems To initiate automatic fire control, suppression systems, sound alarm To supervise fire control, suppression systems to ensure operational status maintained (Continued) Firefighter I

Functions of Fire Detection, Alarm, Suppression Systems To initiate wide variety of auxiliary functions involving environmental, utility, process controls (Continued) Firefighter I

Automatic Sprinkler Protection Consists of series of sprinklers arranged so system will automatically distribute sufficient quantities of water directly onto fire Water supplied to sprinklers through system of piping (Continued) Firefighter I

Automatic Sprinkler Protection Sprinklers can extend from exposed pipes or protrude through ceiling or walls from hidden pipes Sprinkler coverage; complete or partial (Continued) Firefighter I

Automatic Sprinkler Protection Standards used as guides for installing sprinkler protection in most occupancies Sprinkler system should be listed by nationally recognized testing laboratory Automatic sprinkler systems fail to operate only in rare instances Firefighter I

Effects of Sprinkler Systems on Life Safety Safety of building occupants enhanced by presence of sprinkler system because it discharges water directly onto fire while still relatively small (Continued) Firefighter I

Effects of Sprinkler Systems on Life Safety Because fire extinguished/controlled in early growth stage, combustion products limited Sprinklers also effective in other situations There are times when sprinklers alone are not as effective Firefighter I

DISCUSSION QUESTION What effect does a fire sprinkler system have on firefighter safety? Firefighter I

Control Valves Part of every sprinkler system Used to turn off water supply to system in order to replace sprinklers, perform maintenance, interrupt operations (Continued) Firefighter I

Control Valves Located between source of water supply, sprinkler system Usually located immediately under sprinkler alarm valve, dry-pipe or deluge valve, or outside building near sprinkler system it controls (Continued) Firefighter I

Control Valves Either secured in open position with chain and padlock or electronically supervised to make sure not inadvertently closed Firefighter I

Indicating Control Valves Show at glance whether open or closed Outside stem and yoke (OS&Y) valve (Continued) Firefighter I

Indicating Control Valves Post indicator valve (PIV) (Continued) Firefighter I

Indicating Control Valves Wall post indicator valve (WPIV) (Continued) Firefighter I

Indicating Control Valves Post indicator valve assembly (PIVA) Firefighter I

Operating Valves Alarm test valve Inspector’s test valve Main drain valve Firefighter I

Wet-Pipe Systems Used in locations where temperatures below 40°F (4°C) not expected Simplest type of automatic fire sprinkler system (Continued) Firefighter I

Wet-Pipe Systems Generally require little maintenance Contain water under pressure at all times Connected to public/private water supply so fused sprinkler immediately discharges water spray, actuates alarm (Continued) Firefighter I

Wet-Pipe Systems Usually equipped with alarm check valve installed in main riser adjacent to where feed main enters building Newer versions may have a backflow prevention check valve and electronic flow alarm. (Continued) Firefighter I

Wet-Pipe Systems May be equipped with retarding device as part of alarm check valve Firefighter I

Dry-Pipe Systems Used in locations where piping may be subjected to temperatures below 40°F (4°C) (Continued) Firefighter I

Dry-Pipe Systems Have pitched (sloped) pipes to help drain water in system back toward main drain Replace water in sprinkler piping with air under pressure (Continued) Firefighter I

Dry-Pipe Systems Designed so small amount of air pressure above dry-pipe valve will hold back much greater water pressure on water supply side of dry-pipe valve Equipped with electric or hydraulic alarm-signaling equipment (Continued) Firefighter I

Dry-Pipe Systems Larger systems may have several-minute delay while air expelled from system Firefighter I

Preaction Systems Dry systems that employ deluge-type valve, fire detection device, closed sprinklers Used when especially important to prevent water damage, even if pipes broken (Continued) Firefighter I

Preaction Systems Will not discharge water into sprinkler piping except in response to smoke- or heat-detection system actuation Sound alarm to give warning before opening of sprinklers Firefighter I

Deluge Systems Similar to dry-pipe system in no water in distribution piping before system activation Differ from dry-pipe systems in sprinklers have no fusible links, do not function as fire detection devices (Continued) Firefighter I

Deluge Systems Designed to quickly supply large volume of water to protected area Sometimes used to discharge foam/other extinguishing agents in occupancies containing flammable liquids, other volatile fuels Firefighter I

Residential Systems Installed in one- and two-family dwellings Designed to give occupants of dwelling chance to escape, prevent total involvement in room of origin Employ quick-response sprinklers (Continued) Firefighter I

Residential Systems Use several types of piping systems Must have pressure gauge, flow detector, means for draining and testing system Can be either connected directly to public water supply or to dwelling’s domestic water system (Continued) Firefighter I

Residential Systems Require control valve to turn off water to sprinkler system and to domestic water system if connected; if sprinkler system supplied separately from domestic water system, sprinkler control valve must be supervised in open position (Continued) Firefighter I

Residential Systems Operate in same manner as other wet-pipe/dry-pipe systems May be equipped with fire department connection (FDC); FDC may be 1½-inch (38 mm) connection Firefighter I

Important Factors in Occupancies With Activated Sprinkler Systems Early-arriving pumper should connect to FDC in accordance with preincident plan Firefighters should make every effort to supply adequate water to operating sprinkler system (Continued) Firefighter I

DISCUSSION QUESTION What is the purpose of a pumper supplying the FDC immediately? Firefighter I

Important Factors in Occupancies With Activated Sprinkler Systems Water supply may have to be conserved to supply sprinkler system Sprinkler system control valves must be open (Continued) Firefighter I

Important Factors in Occupancies With Activated Sprinkler Systems Sprinkler control valves should not be closed until fire officers convinced further operations will simply waste water, produce heavy water damage, hamper progress of final extinguishment (Continued) Firefighter I

Important Factors in Occupancies With Activated Sprinkler Systems When a sprinkler control valve closed, firefighter with portable radio should be stationed at valve in case it needs to be reopened In some departments, SOP to plug open sprinklers rather than shut entire system down (Continued) Firefighter I

Important Factors in Occupancies With Activated Sprinkler Systems Pumpers should not be disconnected from FDC until after extinguishment confirmed by thorough overhaul Sprinkler equipment should be restored to service before leaving premises (Continued) Firefighter I

Important Factors in Occupancies With Activated Sprinkler Systems Firefighters may be required to stop flow of water from single sprinkler that has been activated Firefighter I

Summary Many of the buildings to which firefighters are called for emergency operations are protected partially or fully by automatic fire detection and/or suppression systems. (Continued) Firefighter I

Summary Firefighters need to familiarize themselves with the types of systems installed in their area of responsibility. They should also learn the locations of these systems as well as the capabilities and limitations of each type of system. Firefighter I