LT-V: controlling a pressure control valve Presentation of the LT-V Data Logger (March 2014) # 1.

Slides:



Advertisements
Similar presentations
Prescient II Extinguishing Control Panels
Advertisements

Intelligent Pressure and DMA Management
Refrigeration Systems
Summary Summary This slides is for information Purposses on
HYDRAULICS & PNEUMATICS
Fluid Power Symbols.
Hydraulic fluid flow through an HWH dual cylinder (Synchronized) room extension.
“NEFTOGAZ TECH” LLC President of the Group of companies “ND” Leonid Pashkevych, 2014 Specialized presentation about the System of complex automation of.
Refrigeration Flow Control
Getting Started Product Description Setting Parameters How does it work Wiring Diagram.
Remote Monitoring and Management Solutions ®
Advanced Control Systems
Hydraulics.
Normal Operating Parameters Maintenance Schedule Common Problems Normal Operating Parameters Maintenance Schedule Common Problems ClearWater Tech, LLC.
Friday Cyo (Thu. 22h) Point 6 – After the energy scan of yesterday afternoon, we have discovered generator B2/MKBH-A (One changed during this TS) has around.
1 Week 5 SEQUENTIAL MOTION (LDR) Matakuliah: Mechatronics 2 Tahun: 2005 Versi: 1.0/0.
Pneumatic Logic Sensors and Actuators
Data Logger for Water Meter Function Continuously counts pulses from pulse output of the water meter (or other meters with pulse output) and periodically.
Chapter 8 Output Modules.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Sensors and Actuators John Errington MSc. Sensors and Actuators Sensors produce a signal in response to a change in their surroundings e.g. Thermostat.
Logic Functions OR Operation
Lease Automatic Custody Transfer
Electro-Pneumatics Module 1
MOST RELIABLE COMBINATION MASTER VALVE, WATER METER AND FLOW SENSOR
NEPTUNE Branch Unit Operations and Circuit Design Shuai Lu, Prof. El-Sharkawi EE, University of Washington March 31, 2005.
IRRInet & ICC System Concept
(University Lille1/Polytech’Lille)
Private and Confidential TraceTek iServer Concepts, Set-up, Operation.
Experts in Chem-Feed and Water Treatment An Overview of Possibilities Dulcometer Disinfection Controller ( DDC )
GEOGRAPHICAL INFORMATION SYSTEM (GIS)
PWC Preferred Instruments a division of Preferred Utilities Mfg. Corp. Plant Wide Controller (PWC) Overview.
Training Course SuperCool 1000 Level 1 Course #P0131.
Cooling of NA62 vacuum system November 11 th, 2014 E. Harrouch, EN-MEF, on behalf of the NA62 Vacuum Team.
Tier 2 Power Supply Planning Workshop Advanced AMI Benefits Overview.
Experts in Chem-Feed and Water Treatment beta Metering Pumps 1.
Communications & Computer Networks Resource Notes - Network Hardware
HYDRAULICS & PNEUMATICS
Hydraulics is defined as the study of fluid behavior, at rest and in motion Properly designed piping with sound hydraulics can: - Greatly reduce maintenance.
Service Section Technical Training December 2005.
DPCL Solid State Device Discrete Control Lecture.
New product introduction:
Hardware, 010 – Revision notes Scales use Controller board O/Ps for Feed Control (FCE’s) Flow meters use their own on board O/Ps for Feed Control (FCE’s)
LCD Wiring Diagram Presentation B / B.
COOLING BY EVAPORATION OF PERFLUOROCARBONS Why evaporate? 1. To enhance the heat transfer per unit area The heat transfer coefficient increases significantly.
Proportional and Servo Valves
Hydraulic Pressure Control
A microcontroller-based system for multi sensor monitoring and messaging via GSM network Bachelor thesis Angelakis Vaios Supervisor:Kazarlis S.
Hall B Drift Chamber Gas System Proposal. Using New Equipment Ethernet EPICS Analog In Analog Out MKS GE50 Ethernet Switch Ethernet cRIO.
Installation rules and guidelines
Controlled Rectifiers. Thyristor Thyristors have three states: Reverse blocking mode Forward blocking mode Forward conducting mode.
Preferred Instruments a division of Preferred Utilities Mfg. Corp. Plant Wide Controller (PWC) Overview.
Photo size is: Versatronic
KFA45 Hydraulic System Upgrade – “Full” Option” Controls Implications
Water Loss Audit Findings (FY 13-14)
Helium spill in LHC tunnel
INTRODUCTION TO PLC.
Aims and Objectives Wireless types Wireless Devices Standards
Electrical actuation systems
Gas Power Cycle - Internal Combustion Engine
Water Well Screens. Johnson Screens Rod Based Well Screens.
Hydraulic Pressure Control
Training Course SuperCool 1000 Level 1
BLOCK DIAGRAM: Micro controller.
Communications & Computer Networks Resource Notes - Network Hardware
Part of Module Asset Management: Operation and Maintenance
NEW ARISTON STORAGE BOILERS March, 2009.
Flow Control Valves & Pressure Relief valves
Introduction to Electro-pneumatic
Presentation transcript:

LT-V: controlling a pressure control valve Presentation of the LT-V Data Logger (March 2014) # 1

LT-V: controlling a pressure control valve LT-V Applications  Valve opening / closing Isolate sub-networks to control water circulation  Precise measurement of nighttime flow  More precise leak detection  …  Pressure variation Reduce leaks  Normal pressure during the day / reduced at night  Output objective (> 85%) Increase network longevity  Reduce excess pressure at night

LT-V: controlling a pressure control valve LT-V = LT + 1 solenoid output  Specific product: LT + 1 Latch solenoid output expansion card, 3 wires, 12 V Compatible solenoid: Bermad S-985-3W (model compatible with many different models of valve). Path 1 Path 3 Path 2: Shared LT-V

LT-V: controlling a pressure control valve  The hydraulic cabling determines the behaviour of the valve  Opening / closing  Transfer between two pressure levels pre-set by the operator Opening / closing Operating modes Solenoid Transfer Day pressure / Night pressure Solenoid Day pressure Night Pressure Closure of the valve

LT-V: controlling a pressure control valve  Timed  One time slot per day  Each day, the solenoid switches:  from path 1 to path 3 at xx:xx (day)  from path 3 to path 1 at xx:xx (night)  Remote control by WEB LS  On flow  The solenoid switches when the flow threshold is exceeded Configuration of a threshold for average flow Requires a meter or flow meter  Remote control by WEB LS  Timed and flow  Control according to time slot and flow Overrides timed control if flow is higher than configured threshold (e.g.: intervention of fire brigade at night)  Remote control by WEB LS Control modes