Direct heating system ECOFLOOR Installation guide.

Slides:



Advertisements
Similar presentations
Contents: Cover
Advertisements

P1.1.4 Heating and Insulating Buildings
YUSUF OZ FATIH BOLUKBAS HUSEYIN ANIL KARABULUT. INTRODUCTION HOW DOES A CONTAINER BECOME HOUSE? DESIGN EXAMPLES A NEW HOME IN 12 STEPS TECHNICAL SPECIFICATIONS.
Electrical Trunking Lincoln Robinson Caliphor Fagan Richard Lawrence
Under Tile Spooled cable installation instructions Ceramics: Wooden Laminate: Terracotta: Stone: Marble: Slate: Cork; Vinyl. Included in each Kit: Under.
Amorim Revestimentos, S.A. Professional Training Product Management Installing stick down floors with PVC backing INSTALLING STICK DOWN FLOORS WITH PVC.
NGfL CYMRU GCaD FLOOR COVERINGS.
RADIANT HEATING SYSTEMS ECOFILM an electric heating foil.
1. Install the heat insulation on the floor. 2. Install the power film on the heat insulation. 4. Connect the thermostat and temperature sensor with power.
Presentation for carbon heating film installation. Dear Customers, the carbon heating film is a new and advance heating technology used for wooden and.
WOOD LIGHT FRAME CONSTRUCTION
Presentation.
Snow Melting 5) Calculating the Circuit Information Divide total tubing by max. circuit length (round up)
T6. DESIGN OF REINFORCED CONCRETE BEAM Reinforced concrete framed building T6. Design of reinforced concrete beam page 1. Alaprajz Floor plan Beam: linear.
Machine Tools And Devices For Special Technologies Semiconductive component manufacturing Slovak University of Technology Faculty of Material Science and.
ONE-WAY SLAB. ONE-WAY SLAB Introduction A slab is structural element whose thickness is small compared to its own length and width. Slabs are usually.
SIS 100 – Fast ramped superconducting magnets E. Fischer, GSI Darmstadt Meeting of the Design Study Committee for the EU contract "DIRACsecondary-Beams"
ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:
Installing Cable Floor Heating Systems This presentation will give you a practical idea of how to install a floor heating system.
Heating foil ECOFILM F Installation guide. ECOFILM F - OPTION Suitable for laminate floating floors: width(mm) input (W/m 2 ) F F (48V) 530.
1 AHT's Technology Amorphous material - a solid with the internal structure of a liquid. Created by accelerated cooling process (1,500,0000°C/sec) of the.
Outcome 2 Materials used to install domestic central heating pipework Unit 208: Central heating systems.
Competency: Draw wall sections and details. Objective: Apply concepts of wood sill and floor construction.
PIPE FEA USING ANSYS.
Presentation on Installation of a Domestic Cold Water Storage Cistern
Chapter 14 Notes. Parquet – Mastic – Resilient (Flooring)– Joist – Terrazzo–
Feng Shui is trademark of Summit International Flooringwww.summit-flooring.com Feng Shui A unique opportunity! Summit International Flooring Introduces.
Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor.
IMMOBILE ACCESS FLOOR SYSTEM  The immobile access floor system is a product which is suitable for different official places. The material.
㈜ D.S.T. 자료용 1. Power film Installation 1. Install the heat insulation on the floor. 2. Install the power film on the heat insulation. 4. Connect the thermostat.
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
HASMUKH GOSWAMI COLLEGE OF ENGINEERING HASMUKH GOSWAMI COLLEGE OF ENGINEERING BRANCH :- ELECTRONICS & COMMUNICATION.
Heating foil Ecofilm C Installation guide. ECOFILM C - OPTION For ceiling heating by heating foil ECOFILM C we offer following types : width (mm) output.
Insulation Ashfield Direct Learning Tim Gregorczyk Your Photo Will go Here! Ks4 Energy.
The new technology for watertight construction joints
Finishing the Building
SARDAR PATEL INSTITUTE OF TECHNOLOGY, PILUDARA Rakholiya bhavdip : [ ] Gevariya balkrushn : [ ] Patel parth : [ ] ( Branch:
Dry type transformers Zaragoza Aluminum vs. Copper
Science Project Advice on how to reduce energy losses.
The 13 Amp PLUG Fuse Insulating Casing Live Wire Neutral Cable grip Flexible Copper conductors Earth.
9. THERMAL MASS  Thermal mass is a measure of a material's capacity to absorb heating or cooling energy. Materials such as concrete or bricks are highly.
Voltage Tester Used for testing voltage on electrical outlets, fuse clips, and circuit breakers will test voltage from 120 to 600 volts.
 Effective height of walls  The effective height of a loadbearing wall is assessed by allowing for the relative stiffness of the elements of structure.
Direct Hot Water. What Cold Water System is Pictured? What hot Water System is Pictured?
Smart heat for comfort and safety Our capabilities for the commercial construction industry.
Unit 6: Building Technology in Construction Learning Outcome Understand the techniques used in the construction of superstructures for low-rise domestic.
Basic Slide Show Under Tile Spooled Heating Installation Guide.
B.E Civil Engineering (Sem-3)
Set Mat DIY Installation instructions Beautifully warm floors for New Homes and Renovations Tiles: Granite: Marble: Parquet: Vinyl: Cork: Included in each.
Creation Clic System Nicolas PERRIN Product Manager.
Full Detailed Under Tile Fee Spooling Installation Instructions Ceramics: Wooden Laminate: Terracotta: Stone: Marble: Slate: Cork; Vinyl. Included in each.
EuroCave Cellar Conditioner CL-C. EuroCave cellar conditioners have been designed to preserve your wine in a perfect environment, guaranteeing minimum.
By Prof.Kuldeep Nayi Sub : Building Construction ( )
Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Floor System Sizes and Materials
Substrate Identification Floors. Principal Substrates T & G floorboards Flooring grade boards Concrete Screeded concrete Tile Backer Boards Under Floor/Under.
Under floor heating Designing underfloor heating (UFH) system must always comply with the system suppliers instructions.
Weber Tile Fixing.
Set Mat DIY Installation instructions
Special-Purpose Outlets— Electric Heating, Air Conditioning
UPPER FLOORS TIMBER AND CONCRETE.
High Order correctors coil manufacturing
Competency: Draw wall sections and details.
Types of Cables.
I. Bogdanov, S. Kozub, V. Pokrovsky, L. Shirshov,
ANNEX E PRESENTER WINSTON THOMAS
FBE04 BUILDING CONSTRUCTION AND MATERIALS
Instructor: Radian Belu, PhD
Pipe fitting Threads on pipe fittings are tapered and rely on the stress generated by forcing the tapered threads of the male half of the fitting.
Presentation transcript:

Direct heating system ECOFLOOR Installation guide

DIRECT HEATING SYSTEM ECOFLOOR - FOR NEW BUILDING APPLICATIONS heating mat or heating cable is placed into flexible cement (glue), on 5 cm concrete layer. power density is used from 100 W/m 2 (for habitable rooms with limited floor temperature) up to 160 W/m 2 (for bathrooms, laundries and no good heat- insulated floors) very good and easy temperature control floor heating is possible to combine with el.convectors or radiant panels

DIRECT HEATING SYSTEM ECOFLOOR - FOR RECONSTRUCTION APPLICATIONS modern floor heating with high level temperature controls heating mat or heating cable is placed into thin layer of flexible cement (glue), on concrete layer or origin tiling. power density is used according to type of room (100 W/m 2 or 160 W/m 2 )

ADVANTAGES OF DIRECT FLOOR HEATING quick reaction to the changes in the user‘s heat requirements (warming of floor up to 20 min) very good, accurate and easy temperature control suitable for renovated floors with limited construction height

ECOFLOOR INSTALLATION at first choose the right floor heating application (storage, semi-storage or direct heating ) calculate the heating loses, total heating output should be greater % then calculated heating loss According to type of room choose an appropriate heating density: - permanentaly occupied rooms up to 100 W/sqm - rooms occupied for short periods (bathrooms, - toilets) up to 160 W/sqm - laminated floors up to 80 W/sqm - wooden floors up to 60 W/sqm

INSTALLATION NOTICES minimum distance of floor heating system from walls and fixtures like bath, shower or toilet is 5 cm. the heating cable may never be shortened or cutted !!! (only the cold connection lead)

INSTALLATION NOTICES Heating cables must not be crossed and must not be intersected each other. Minimum distance between heating cables is 3 cm the connector between the cold connection and heating cable needs to be install in straight stretcht (never be installed at a bend!) the heating cable may never pass over an expansion joint

EXPANSION WHY: the floor construction expands when temperature rises and must be furnished with expansion elements to prevent the floor construction being stressed ( tiling could be damaged, base layer cracked and peeled etc.) Expansion is necessary to provide: into place around the room‘s circumference, where floor heating will be used.( The whole floor construction must be a floating construction !) expansion is necessary to provide for rooms with area  25 m 2 and for diagonal  7 m.

Expansion joints the choice of expansion joints depends on room‘s shape and structure - rooms with „L,Z,or T“ shapes should be divided into rectangular or squere sections Expansion joint must not be discontinued and for cementation process is recomended flexible cement ECOFLOOR heating cables and mats may never cross the expansion joints ! If the cold connections pass the expansion joints, they must lay freely within protective tubes

Heating mat/cable ECOFLOOR laying to the flexible cement (glue) –new building 1. On the base(1)place thermal insulation (2)– expanded polystyrene at least or extruded polystyrene of min. thickness 5 cm 2. Place the steel reinforcement (3)to harden the concrete layer. Place the concrete layer 5 cm thick(4) 3. Penetrate the concrete layer. ECOFLOOR cables/mats (6) place into flexible cement (5). 4. Measure el parameters of heating system and lay the tiles. (7)

Heating mat/cable ECOFLOOR laying to the flexible cement (glue) – floor reconstruction 1.Clean and penetrate the original tiling 2.Into flexible gluing cement place the ECOFLOOR heating cables/mats 3.Measure the parameters of heating cable/mat 4. Laying of new tiles

Other possibility of ECOFLOOR laying Wooden floor construction

Other possibility of ECOFLOOR laying Plasterboard floor construction

Other possibility of ECOFLOOR laying Construction with self-levelling cement

INSTALLATION OF ECOFLOOR HEATING CABLE CIRCUIT ADSL1P COMFORT DIRECT FLOOR HEATING UNDER TILES ADSV Heating cable circuit (double conductor with 1 connection lead „cold tail“ 1. Control measuring 2. Grooving for thermostat floor probe 3. Floor base cleaning and penetration 4. Floor probe installation 5. Fixation of el.conncector 6. Installation of Heating cable circuit 7. Control measuring8. Thin layer flexible cementing (glueing) 9. New tiling

INSTALLATION OF ECOFLOOR HEATING MAT LDTS COMFORT DIRECT FLOOR HEATING UNDER TILES LDTS Heating mat (double conductor with 1 connection lead „cold tail“ 1. Control measuring 2. Grooving for thermostat floor probe 3. Floor base cleaning and penetration 4. Floor probe installation 5. Heating mat laying 6. Mat sticking to the floor base by its self- adhesive tape 7. Control measuring8. Thin layer flexible cementing (glueing) 9. New tiling 6. Heating mat installation

FLOORING MATERIAL The most suitable for ECOFLOOR systems: ceramic tile, marble, natural stone Other suitable: Laminate floating and wooden parquet floors PVC without a rubber base Special carpets without rubber base recommended by their manufacturers for use with floor heating Unsuitable !!!: Carpets with pile more than 10 mm thick or with a rubber base PVC with a rubber

Electrical installation ECOFLOOR heating cable/mat has to be connected to the el.net just by a qualified person accordance with the manufacturer´s instructions The total take-off (Amps) of heating mat/cable must never exceed the maximum value of thermostat switched current

For floor heating are suitable following thermostats: Fenix Therm 100 Eco M/z1 Microline OCD 1999 H Eberle Instat 8 TEMPERATURE CONTROLS Fenix Therm 100

Thermostat connection (thermostat with floor probe) L – phase (el.supply) N – neutral (el.supply) L’ –phase (Ecofloor) N’ – neutral (Ecofloor)

Electrical installation directly throught the thermostat

Electrical installation throught the el.box and contactor (1 thermostat controls 2 Ecofloor units (cables/mats) through the contactor to prevent thermostat switch current overloading)

Direct heating ECOFLOOR Modern and comfort floor heating system

YOUR RIGHT PARTNER IN ELECTRIC HEATING SYSTEMS Contact us : FENIX Trading s.r.o. Slezska Jesenik, Czech Rep. Tel/Fax: /303 Web: