Free PowerPoint Backgrounds Heat Rate Improvement Conference February 5-7, 2013 Scottsdale, Arizona.

Slides:



Advertisements
Similar presentations
CONTROLS OF SUPER CRITICAL BOILERS
Advertisements

OFF DESIGN PERFORMANCE PREDICTION OF STEAM TURBINES
Copyright© 2014 Austin Analytics Group, LLC. Stand Alone System High Temperature System Hazardous Area System Universal/Remote Display System Copyright©
Power Plant Engineering
Antero Punttila Analyzing most typical energy saving measures Energy Efficiency of Steam and Condensate Systems Antero Punttila, Motiva Oy.
Energy Efficient Steam Systems
Circulating Water System
Good Steam Engineering means Proper sizing, insulation, routing and trapping High pressure distribution and reduction at the point of use Separating condensate.
Energy Efficiency and Intelligent Power Plants Rameshbabu R S 10 th May, 2006 The Center For Bits And Atoms MIT.
Summer Co-op Experience: OPG Aditi Garg. Darlington Nuclear G.S Located in Bowmanville, ON.
The Heat robbers ! 100% fuel energy 80% steam 3% distribution losses 77% Process consumption 57% 20% Unburnt Stack Blowdown (Condensate & Flash)
Superheaters.
Driving Toward Energy Efficiency Emerson Process Management Novaspect. Inc. June 22 / 23, 2010 Steam.
Power Plant Construction and QA/QC Section 2.4– Boiler Auxiliaries
Chapter 1 VAPOR AND COMBINED POWER CYCLES
Drug Delivery & Tissue Engineering Laboratory
Control and regulation of boiler operation Heat Engines & Boilers.
Walter G Bischoff Brunswick station Duke Energy
Capture of Heat Energy From Diesel Engine After Cooler Circuit (2006 Annual Report) Mark Teitzel Alaska Village Energy Corporation
“Energy Efficiency Guide for Industry in Asia”
Steam Power Plant.
ENERGY AUDIT INSTRUMENT
POWER PLANT.
Jim Chmielewski – HVAC Sales Manager Emerson Control Techniques
STEAM CONDENSERS.
This tutorial is a PowerPoint ® file which includes recorded narration. Automatic slide sequencing is coupled to the sound track. For the most effective.
Boiler efficiency Heat Engines & Boilers.
Lesson 7 Steam Power Plant.
TURBINE & COOLING SYSTEM Presented By – AVIJEET PRATAP 07ME12 IET AGRA
Steam Power Station Presented By Ashvin G. Patel Asst. Prof. (E.E.)
Lease Automatic Custody Transfer
Chem. Eng. Thermodynamics (TKK-2137) 14/15 Semester 3 Instructor: Rama Oktavian Office Hr.: M.13-15, Tu , W ,
Quantifying Cycle Isolation Losses and Integration with On Line Systems Feedwater System Reliability Users Group 2015 Meeting San Antonio Ken Porter Rich.
STUDY OF BOILER’S ACCESSORIES
Prof. D.N. Reddy Director Centre for Energy Technology University College of Engineering Osmania University.
Folie 1 Quality Management in local biomass district heating plants and grids Optimising operations based on monitoring activities biomass energy for heating.
BOILER PLANT OPERATION Presented By Mr. Sivanand Ray
Energy And Environmental Technology
Steam Turbine power plant
Lesson 8 SECOND LAW OF THERMODYNAMICS
Improved Precision Leading to Improved Energy Efficiency Edward Decker AE 790 – Intelligent Buildings June 6, 2006.
INTRODUCTION. Function of Chillers Remove Cool Control Support.
Lecture Objectives: Finish with absorption cooling Power generation Rankine cycles Connect power generation with heating and cooling –CHP –CCHP.
STEAM POWER PLANTS.
Seminar on, “ CALIBRATION TECHNIQUES FOR MAGMETERS” Presented By, Bhushan Patil Guided By, Prof. A.S. Kulkarni.
New Product Developments World Leaders in Combustion Management Solutions Mk7 Expansion PCB Mk7 Expansion PCB.
New Product Developments World Leaders in Combustion Management Solutions New Products New Products.
A Seminar On Suratgarh Super Thermal Power Station (Raj.)
THERMAL POWER PLANT. INTRODUCTION : THERMAL POWER PLANTS CONVERT THE HEAT ENERGY OF COAL INTO ELECTRICAL ENERGY. COAL IS BURNT IN A BOILER WHICH CONVERTS.
THERMAL POWER PLANT.
Training Presentation On Suratgarh Super Thermal Power Station (Raj)
Presentation on Steam Power Plants R.C.Chaturvedi
CIBSE HCNW 28 August 2014 Modular boilers. Traditional or low-tech replacement boiler installation; Multiple boilers eg 2 no 66% of load for security.
HEAT-GENERATING EQUIPMENT INTRODUCTION SELECTION EFFICIENCY FURNACES BOILERS CENTRAL HVAC SYSTEMS.
Lesson 7 Steam Power Plant.
Humidity Measurement Benefits in Power Applications
Chapter No-5 STEAM CONDENSERS AND COOLING TOWERS Marks-16
Review Questions Chapter 5
Heat Exchangers and Condensers
Kessler-Ellis Products
Thermodynamics Cycles.
Humidity Measurement Benefits in Power Plant Applications
Thermodynamics Processes.
Power Plant Technology Combined Cycle and Renewable Energy Power Systems (Assignment 1) by Mohamad Firdaus Basrawi, Dr. (Eng) Mechanical Engineering Faculty.
POWER PLANT THERMAL POWER STATION.
PRODUCTS (POWER PLANT)
Power Plant Engineering. Boilers Boilers Boiler is an apparatus to produce steam. Thermal energy released by combustion of fuel is used to make steam.
STEAM CONDENSERS AND COOLING TOWERS Marks-16
Condenser in Power Plants
Presentation transcript:

Free PowerPoint Backgrounds Heat Rate Improvement Conference February 5-7, 2013 Scottsdale, Arizona

Free PowerPoint Backgrounds Presented by: Richard Kadim MSc (Hons) MIET Lead Performance Engineer Aberthaw Power Station 3 x 535MW Coal Fired RWE npower South Wales United Kingdom Maintaining Condenser Performance Speaker’s Notes : Richard Kadim is Lead Performance Engineer at RWE npower Aberthaw Power Station in South Wales, U.K. The station is coal fired, began full operation in 1971 and is opted in under the Large Combustion Plant Directive.

Free PowerPoint Backgrounds Background For Turbine Heat Rate, the greatest amount of heat rejected occurs in the condensing steam, so that maintaining condenser performance is a key parameter for overall plant efficiency. A typical condenser exhaust pressure deviation of 1 mbar can reduce thermal efficiency by approximately 0.1%. The efficiency losses for this are:- Increased fuel burn Increased works power The commercial losses are generation imbalances on grid demand profiles Speaker’s Notes : The steam condenser is critical in optimising the performance of the plant, and the potential financial losses of poor condenser performance are well understood.

Free PowerPoint Backgrounds Condenser High Exhaust Pressure This is mainly due to:- Higher cooling water inlet temperatures, which are seasonal and tidal or poor cooling tower performance Low or restricted cooling water flow due to tides, river levels, debris in strainers or valve position errors Water box priming problems Condenser water box tube plate fouling due to algae or debris Speaker’s Notes : Elevated condenser pressure and the resulting high turbine back pressure cause large inefficiencies, so their causes should be understood and investigated.

Free PowerPoint Backgrounds Condenser High Exhaust Pressure (continued) This is mainly due to:- Steam space fouling or scaling of condenser tubes due to contamination Air ingress levels into the condenser Poor air extraction plant performance

Free PowerPoint Backgrounds Indentifying Poor Condenser Performance Cooling water temperatures & flows are monitored continuously by specific instruments, CW inlet & outlet temperatures & CW Condenser flow meters Air ingress, tube fouling & air extraction plant performance is not so easy to monitor continuously and regular manual plant performance tests are required Multiple business demands limit the resources to carry out regular monitoring Speaker’s Notes : Although overall plant efficiency is a major priority other responsibilities limit the time that engineers have available for testing, real time automated monitoring is essential.

Free PowerPoint Backgrounds Improved Monitoring with fast response Instruments Fitting an Air ingress Monitor provides constant, online condition monitoring and therefore immediate identification of poor condenser performance due to Air ingress, tube fouling or Extraction plant inefficiency In our many years' experience of Air Ingress Monitors, we have output data to trend air ingress levels, provide temperature indication on tube fouling & absolute pressure on deteriorating pump performance Speaker’s Notes : Although the Chell Instruments air ingress monitor’s primary function is to quantify in real time the air being removed from the condenser (and therefore the quantity that has leaked in), its additional absolute pressure and temperature outputs are also useful in detecting other problems.

Free PowerPoint Backgrounds Improved Monitoring with fast response Instruments This trend data allows developing problems to be identified and addressed with scheduled maintenance before they become critical and trip the condenser Speaker’s Notes : Outputs from the air ingress monitor, as individual 4-20 mA signals and/or via the serial interface are integrated into the plant operating software. Trends in individual parameters can be easily seen and alarms can be assigned to predetermined points. Data can also be logged and compared to historical records for further analysis..

Free PowerPoint Backgrounds AIM Functionality 5 x 4-20mA outputs RS232/485 RTD Temperature Probe Duct Temperature Air Content Differential Pressure Absolute Pressure Heated Differential Capacitance Manometer Absolute Capacitance Manometer Averaging Pitot Tube Steam/Air Mixture from Condenser

Free PowerPoint Backgrounds AIM Functionality Speaker’s Notes : It is essential that the air ingress monitor is accurate, repeatable and reliable. The Chell system uses an, averaging stainless steel Pitot tube that has a platinum resistance thermometer down the centre, fitted in the condenser air extraction pipe. They have no moving parts and do not expose any electronics to the media, so are very reliable. A single PRT cable and two impulse lines connect the Pitot tube to the measurement electronics, which include a differential pressure transducer (pressure differential across the Pitot is proportional to the square of the flow rate), absolute pressure transducer and the signal processing electronics. The basic theory of operation is that the measured temperature is used to calculate the absolute pressure of saturated steam, which is deducted from the measured total absolute pressure to give the partial pressure of air. The measured and calculated parameters, together with the pipe cross sectional area are then used to calculate the air / steam ratio and the mass flow rate..

Free PowerPoint Backgrounds Condenser Fouling Speaker’s Notes : The Aberthaw plant does not suffer with a high level of condenser steam space fouling or scaling..

Free PowerPoint Backgrounds Monitoring Condenser Air Ingress Speaker’s Notes : Monitoring of condenser air ingress and absolute pressure against plant load.

Free PowerPoint Backgrounds The Risks of High Air Ingress Pipework corrosion and leaks Speaker’s Notes : After more than 40 years of operation corrosion is a continuing problem, causing leaks that are often hidden under insulation or in hard to access areas. These leaks in turn cause further corrosion due to increased levels of dissolved oxygen in the boiler feed water.

Free PowerPoint Backgrounds Continuous Monitoring of Air Ingress Speaker’s Notes : Chell air ingress monitors have been used for many years as can be seen by the age of the units above. Apart from their longevity the fact that the latest model is still backward compatible with the original allows them to be swapped for maintenance or calibration.

Free PowerPoint Backgrounds Conclusions Air Ingress Monitors - Provide constant, online condition monitoring and therefore immediate identification of poor condenser performance due to air ingress, tube fouling or extraction plant inefficiency Output real-time engineering units data to trend air ingress levels Output Absolute pressure on deteriorating pump performance Output real-time Temperature data on tube fouling

Free PowerPoint Backgrounds Conclusions (continued) Air Ingress Monitors - Data trending allows progressing problems to be identified and addressed with scheduled maintenance before they become critical and trip the condenser Correctly set up, minimum maintenance & annual calibration of AIMs provides instant, continuous on- line condenser performance monitoring

Free PowerPoint Backgrounds Thank you for your attention Richard Kadim