1 The University Centre in Svalbard (UNIS), N-9171 Longyearbyen, Norway 2 The Norwegian Polar Institute, Ny-Ålesund, Norway 3 Norwegian Institute of Fisheries.

Slides:



Advertisements
Similar presentations
Good Practices of Fluorescence Spectroscopy
Advertisements

1 ATST Imager and Slit Viewer Optics Ming Liang. 2 Optical layout of the telescope, relay optics, beam reducer and imager. Optical Layouts.
OL 750 Diffuse Spectral Reflectance Measurement System
A Guide to Spectroradiometry
Spectral Resolution and Spectrometers
990901EIS_Opt.1 The Instrument: Optical Design Dr. John T. Mariska Data Coordination Scientist Naval Research Laboratory
Hyperspectral imaging of aurora and airglow at KHO Fred Sigernes 1,*, Yuriy Ivanov 2, Sergey Chernouss 3, Trond Trondsen 4, Alexey Roldugin 3, Yury Fedorenko.
Motivation Spectroscopy is most important analysis tool in all natural sciences Astrophysics, chemical/material sciences, biomedicine, geophysics,… Industry.
Optical Astronomy Imaging Chain: Telescopes & CCDs.
Spectral Resolution and Spectrometers A Brief Guide to Understanding and Obtaining the Proper Resolution of the 785 Raman System.
7. Beer’s Law and It’s Implications for Instrument Construction.
ABRF meeting 09 Light Microscopy Research Group. Why are there no standards? Imaging was largely an ultrastructure tool Digital imaging only common in.
Characterization of primed state of CVD diamond by light and alpha particles C. Manfredotti Experimental Physics Department University of Torino INFN-
1 Estimate on SOT light level in flight with throughput measurements in SOT sun tests T. Shimizu 1, T. Tarbell 2, Y. Suematsu 3, M. Kubo 1, K. Ichimoto.
S. Bricola, A. Menegolli, M. Prata, M.C. Prata, G.L. Raselli, M. Rossella, C. Vignoli INFN and University of Pavia - Via Bassi, 6 – Pavia – Italy.
OL 750 Measurement Systems
SCIFER2 UV Emissions Allison Jaynes, UNH Dartmouth CASCADES2 Meeting 10/30/09 Allison Jaynes, UNH Dartmouth CASCADES2 Meeting 10/30/09 (Images, movie and.
Spectrophotometer Jan 28, 2002 Deryck Hong Suryadi Gunawan.
Digital Cameras (Basics) CCD (charge coupled device): image sensor Resolution: amount of detail the camera can capture Capturing Color: filters go on.
CCD testing Enver Alagoz 12 April CCD testing goals CCD testing is to learn how to – do dark noise characterization – do gain measurements – determine.
1 The University Centre in Svalbard (UNIS), N-9171 Longyearbyen, Norway 2 Magnetosphere Ionosphere Research Lab, University of New Hampshire, USA 3 Keo.
Optical characteristics of the EUV spectrometer for the normal-incidence region L. Poletto, G. Tondello Istituto Nazionale per la Fisica della Materia.
Grazing-incidence design and others L. Poletto Istituto Nazionale per la Fisica della Materia (INFM) Department of Electronics and Informatics - Padova.
Astronomical Instrumentation Often, astronomers use additional optics between the telescope optics and their detectors. This is called the instrumentation.
5 Components Common to All Optical Spectrometers Source Transparent Sample Holder Wavelength Selector Radiation Detector Signal Processor and Readout.
SPECTROSCOPIC DIAGNOSTIC COMPLEX FOR STUDYING PULSED TOKAMAK PLASMA Yu. Golubovskii, Yu. Ionikh, A. Mestchanov, V. Milenin, I. Porokhova, N. Timofeev Saint-Petersburg.
The Mid-Infrared Instrument (MIRI) Medium Resolution Spectrometer for JWST Martyn Wells MIRI EC & UKATC.
HSX Thomson Scattering Experiment K. Zhai, F.S.B. Anderson, and D.T. Anderson HSX Plasma Laboratory University of Wisconsin-Madison, The HSX Thomson Scattering.
14 October Observational Astronomy SPECTROSCOPY and spectrometers Kitchin, pp
Spectroscopic Observations (Massey & Hanson 2011, arXiv v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration.
High Resolution Echelle Spectrograph for Chinese Weihai 1m Telescope. Leiwang, Yongtian Zhu, Zhongwen Hu Nanjing institute of Astronomical Optics Technology.
First results of the tests campaign in VISIBLE in VISIBLE for the demonstrator 12 October 2007 SNAP Collaboration Meeting Paris Marie-Hélène Aumeunier.
18 October Observational Astronomy SPECTROSCOPY and spectrometers Kitchin, pp
Optical Aeronomy Calibration Facility CEDAR WORKSHOP JUNE, 2007 Jeff Baumgardner, Center for Space Physics Boston University.
Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric Measurement System Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric.
1 SNAP Calibration Hardware Contributors: Chuck Bower Nick Mostek Stuart Mufson Mike Sholl.
DECam Daily Flatfield Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University.
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
OL 750 Measurement Systems OL 750 Measurement Systems Optronic Laboratories, Inc.
Optical characteristics of the EUV spectrometer for the grazing-incidence region L. Poletto, G. Tondello Istituto Nazionale per la Fisica della Materia.
Sensitivity Calibration of Narrow Field of View Optical Instruments F. Sigernes 1, T. Svenøe 2, J. Holmes 1, M. Dyrland 1, D.A. Lorentzen 1, J. Moen 3,
14 January Observational Astronomy SPECTROSCOPIC data reduction Piskunov & Valenti 2002, A&A 385, 1095.
Charge-Coupled Devices Astrophysics Lesson 5. Learning Objectives Describe and explain the structure and operation of the charge coupled device State.
IFS prototype – PM3 LAM, 13/06/2003 Prototype testing at CRAL Tests at room temperature in the visible.
Laser Spectroscopy/SJX Chap. 4 Components of Spectroscopic Instruments 1 In this chapter we discuss basic spectroscopic instruments and techniques employed.
1 Progress of the Thomson Scattering Experiment on HSX K. Zhai, F.S.B. Anderson, D.T. Anderson HSX Plasma Laboratory, UW-Madison Bill Mason PSL, UW-Madison,
Transmission Measurement Basic Outline. Transmission Curve Describes the percentage of a signal that is transmitted through an object (filter) over a.
Performance and sensitivity of Low Resolution Spectrographs for LAMOST Zhu Yongtian, Hou Yonghui, Hu Zhongwen Wang Lei, Wang Jianing.
ISUAL Design Concept S. Mende. SDR 7 Jun NCKU UCB Tohoku ISUAL Design Concept S. Mende Sprite Example Sprite Image obtained by Berkeley/NCKU 1999.
First Thomson Scattering Results on HSX K. Zhai, F.S.B. Anderson, and D.T. Anderson HSX Plasma Laboratory, U. of Wisconsin, Madison 1. Abstract 5. Summary.
GS-1150 HANDHELD SPECTROPHOTOMETER. ABOUT GAMMA SCIENTIFIC With over 50 years of experience in developing commercial light measurement instruments, Gamma.
Digital Light Sources First introduced in 2001.
Optical Non-Invasive Approaches to Diagnosis of Skin Diseases
Relative Spectral Response and Flat Fields with Internal Calibration Lamps Luisa M. Lara IAA-CSIC Granada (SPAIN)
Single Object & Time Series Spectroscopy with JWST NIRCam
THE LHIRES-III SPECTROGRAPH
Intra-pixel Sensitivity Testing Preliminary Design Review
BASIC HYPER SPECTRAL IMAGING
Instrumentation for Colliding Beam Physics 2017
What Is Spectral Imaging? An Introduction
BASIC HYPER SPECTRAL IMAGING
4. Telescopes Light gathering power and resolution
Volume 84, Issue 6, Pages (June 2003)
Detective Quantum Efficiency Preliminary Design Review
Optical Non-Invasive Approaches to Diagnosis of Skin Diseases
BASIC HYPER SPECTRAL IMAGING
BASIC HYPER SPECTRAL IMAGING
OL 750 Measurement Systems
OL 750 Spectroradiometer & Linear Spectral Transmission Measurements
Spectroscopic Observations (Massey & Hanson 2011, arXiv v2
Presentation transcript:

1 The University Centre in Svalbard (UNIS), N-9171 Longyearbyen, Norway 2 The Norwegian Polar Institute, Ny-Ålesund, Norway 3 Norwegian Institute of Fisheries and Aquaculture, Tromsø, Norway 4 Polar Geophysical Institute, Murmansk Region, Apatity, Russia 5 Geophysical Institute, University of Alaska, Fairbanks, USA 6 Communication Systems, Lancaster University, Lancaster LA1 4WA, UK The absolute sensitivity of digital colour cameras Fred Sigernes 1, Margit Dyrland 1, Nial Peters 1, Dag Arne Lorentzen 1, Trond Svenøe 2, Karsten Heia 3, Sergey Chernouss 4, Charles Sterling Deehr 5 and Mike Kosch 6

CONTENT 1.MOTIVATION 2.EXPERIMENTAL SETUP 3.SPECTRAL RESPONSITIVITY & QUANTUM EFFICENCY 4.RESULTS 5.CONCLUSION F. Sigernes et al., The absolute sensitivity of digital colour cameras, 36 AM

MOTIVATION 1.The cameras are low cost mass products 2.High spatial resolution (stars, satellites...) 3.Sensitivity (< ISO) 4.Simple optical design 5.The main auroral emissions (4278, 5577 &6300) are well colour channel separated 6.Colour classification of sky conditions (clouds, snow, light pollution & aurora) 7.Can operate in all types of light conditions including periods of full moon. 8.It is relatively easy to flat field calibrate and find mapping functions of lenses by the use of stars. 9.Useful in public presentations 10.The cameras are not intensity calibrated! F. Sigernes et al., The absolute sensitivity of digital colour cameras, 36 AM Starlight Xpress Fujinon F/1.4 Nikon D80 ISO 1600 F/2.8 20s Watec 120N+ Fujinon F/1.4 2s SXVF-H9C & KHO

EXPERIMENTAL SETUP Experimental setup: (1) fiber bundle from lamp located in neighboring room, (2) mount / stand for integrating sphere, (3) order sorting filter wheel in front of entrance slit, (4) Jobin Yvon HR320 monochromator, (5) table, (6) exit slit plane, (7) Edmund Scientific integrating sphere, (8) laboratory lift table, (9) fiber bundle holder, (10) camera table, (11) fiber bundle used as input to spectrograph, (12) Oriel FICS 7743 spectrograph, (13) optical mount rail, and (14) DSLR camera with normal 50 mm f/1.4 objective. Canon 40DNikon D300

OPTICAL DIAGRAM Optical elements: [A] Leica 150W fiber illuminator: (1) mirror, (2) Tungsten filament, (3) heat filter, (4) blocking wall, and (5) fiber bundle. [B] Jobin Yvon HR320 Monochromator: (6) f-matching lens, (7) order sorting filter, (8) entrance slit, (9) collimator mirror, (10) plane reflective grating, (11) focusing mirror, (12) flat surface folding mirror, and (13) exit slit. [C] Edmund Scientific General purpose 6 inch diameter integrating sphere: (14) sphere, and (15) transmitting diffuser (Teflon). [D] DSLR camera: (16) 50 mm normal f/1.4 objective, and (17) CMOS / CCD detector. [E] Oriel FICS 7743 spectrograph: (18) order sorting filter, (19) fiber bundle, (20) entrance slit, (21) folding mirror, (22) concave grating, and (23) CCD detector. DSLR Cameras ISO sec exposures f/1.4 F= 50 mm HR320 w x h= 0.5 x 8 mm FWHM ~ 12 Å Grating: 68 x 68 mm grooves / mm F = 320 mm FICS 16 x 250 um fibers FWHM ~ 96 Å Grating: Concave 230 grooves / mm f/2.1 SPHERE 6 inch diameter Spectralon FIBER LAMP 150W Tungsten

DATA HANDLING

THE SPECTRAL RESPONSITIVITY Equation (1) in vector form A set of observations may now be formed The camera detects in color channel (k) [CTS s -1 ] (1) (2) (3) can now be solved by SVD (Singular Value Decomposition in IDL) [R/Å]

THE QUANTUM EFFICIENCY The camera Quantum Efficiency (QE) is defined as [%] (4)  t - Exposure time in seconds g - Conversion factor between number of photo electrons and raw counts per pixel. Known as the Gain of the detector.  A - Pixel area in units of cm 2 At ISO 1600 the gain is and electrons per 12-bit data count for the Canon 40D and the Nikon D300, respectively.

CALIBRATED SPECTRAL LIBRARY FICS FWHM ~ 10 nm VIS / NIR NA = 0.22 Sphere source functions. C i ( ) is the set of observations that consists of 31 spectra from the monochromator (HR320) illuminating the 6 inch diameter integrating sphere from Edmund Optics.

RAW DATA NIKON D300 Settings: ISO sec exposure F= 50 f/1.4 Counts per second [12 bit] FICS

Processed camera data: Panel (A): Solid lines are the spectral responsivity of the Nikon D300 camera for each color channel (Red, Green and Blue). The dotted lines are for the Canon 40D camera. Panel (B) shows the corresponding calculated quantum efficiency (QE). Both cameras were operated with identical settings using normal objective lenses (50mm f/1.4) at ISO 1600.

LENS EFFECTS? Canon EF 50mm f/1.4 USM Nikon 50mm f/1.4 AF-D

CONCLUSION F. Sigernes et al., The absolute sensitivity of digital colour cameras, 36 AM The principal results obtained by this study can be summarized as follows: 1.A fiber optical lamp is connected to the input of a monochromator which is tunable in wavelength in the visible part of the electromagnetic spectrum (4000 – 7000 Å). The output of the monochromator illuminates an integrating sphere with a bandpass of ~12Å. 2.The brightness of the sphere is monitored by an intensity calibrated spectrograph. A library of source functions consisting of 31 monochromatic lines is obtained in the visible part of the electromagnetic spectrum. The intensities range from ~500 to 3300 R/Å. 3.The intensity of the sphere is sufficiently uniform to obtain the average pixel response for each colour channel of a digital colour camera. As a result, it is possible to retrieve the spectral responsivity and the quantum efficiency of each pixel as a function of wavelength. 4.Two semi-professional DSLR cameras, the Nikon D300 and Canon 40D, have been calibrated. The sensitivities based on calculations of spectral responsivity and quantum efficiency, are found to be higher in the blue compared to the green and red channels. The Nikon D300 has a peak quantum efficiency of 50% at 4600 Å, 48% at 5300Å and 35% at 5900 Å. The corresponding spectral responsivity is found to be 4.3x10 -3, 3.9x10 -3 and 2.8x10 -3 in units of counts s -1 R -1. The D300 is slightly more sensitive than the 40D in the blue and green channels. The main difference is found in the red channel. The 40D is up to 50% less red sensitive than the D The ability of a DSLR camera to measure intensity of light in terms of absolute physical units opens up new possibilities. A standard measure such as the quantum efficiency or spectral responsivity could be part of a certificate provided by the manufacturer in the future.