Mist Generator Kelly Toy Jon Cappel Joe Bothwell Abdikarim Mahamud Advisor – John Webster Client – Jack Jiang, MD, PhD tents/06.00/06.00.0609.asp.

Slides:



Advertisements
Similar presentations
DELIVERY OF AEROSOLIZED DRUGS THROUGH CONTINUOUS POSITIVE AIRWAY PRESSURE (CPAP) Team Patrick Kurkiewicz Annie Loevinger Joe Decker Steve Welch Client.
Advertisements

FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Simulation and Analysis of Equally Distributed Flow for Use in Ultrasonic Atomization Lindsay Rogers University of Wisconsin, Platteville Mechanical Engineering.
Public Health Issues Related to Mutually Conforming Labeling: CDRH Perspective Miriam C. Provost, Ph.D. Office of Device Evaluation Center for Devices.
Data Acquisition Risanuri Hidayat.
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
 Using Hydraulic Systems. NEXT GENERATION / COMMON CORE STANDARDS ADDRESSED! CCSS.ELA Literacy RST Cite specific textual evidence to support analysis.
Flow Measurement.
LASERS - PARTICLE SIZE ANALYSIS
Pressure Sensors.
It is the amount of water vapour present in the atmosphere and is subdivided into two types: Absolute humidity: - The total mass of water vapour present.
Level Sensors.
ENERGY AUDIT INSTRUMENT
1 Syafruddin Hasan. 2 Systems Concepts Automated systems that control flow rates or volume employ the following components: Automated systems that control.
1 Syafruddin Hasan. 2 Systems Concepts Automated systems that control flow rates or volume employ the following components: Automated systems that control.
Pressure Measurements Techniques to measure pressure.
Ultrasonic Testing This technique is used for the detection of internal surface (particularly distant surface) defects in sound conducting.
CBE 150A – Transport Spring Semester 2014 Flow Measurement and Control.
Sensors and Actuators John Errington MSc. Sensors and Actuators Sensors produce a signal in response to a change in their surroundings e.g. Thermostat.
Peak Inspiratory and Expiratory Flow Meter Team: Andrew Eley, Sarah Offutt, Darshan Patel, Eric Bader BME 200/300 December 2, 2005.
By : Afaf Hithnawi Dr: Mohammad Sabbah Spray drying 1.
Machining is processes in which we get a desired final shape and size from of raw material. 1.Conventional / Traditional Machining 2.Non Conventional.
EKT314/4 Electronic Instrumentation
Lesson 5 What devices do we use to measure radon?.
Temperature Measurement
Team Members: Joe Bothwell BWIG IT Ryan Fischer Communicator Brant Kochsiek Team Leader Brian Schwartz BWIG David Ugai BSAC Dan Carlson BSAC.
Atomic Emission Spectroscopy
CHAPTER 9 Control System Instrumentation
Team Members: Joe Bothwell Communicator Kelly ToyTeam Leader Jon Cappel BWIG Karim Mahamud BSAC.
Flow Measurement and Control. Orifice Meter The orifice meter consists of an accurately machined and drilled plate concentrically mounted between two.
Mosby items and derived items © 2008, 2002 by Mosby, Inc., an affiliate of Elsevier Inc. Chapter 3 Administration of Aerosolized Agents.
1 Atomic Emission Spectroscopy Lecture Advantages of Plasma Sources 1.No oxide formation as a result of two factors including Very high temperature.
International symposium on innovations in intelligent systems and application, p.p , June 2011 Microcontroller based jet nebulizer design with.
Control System Instrumentation
Flow Measurement and Control
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
Inhalation Devices Heba Abd El-fattah Sabry Pharm D.
Ultrasonic Welding Presented by: Ryan Alexander Chris Baker Jon Stempka.
Pendulum, Medical, Industrial
Using Hydraulic Systems
CHAPTER 9 Control System Instrumentation
Device to Improve Yield of Fine Needle Aspiration TEAM MEMBERS: Kristen Seashore Tu Hoang Anh Mai Chris Goplen Jason Tham CLIENT: Frederick Kelcz, M.D.
3M Drug Delivery Systems 3 Chris Blatchford & Gemma Nixon, 3M Drug Delivery Systems, Morley St, Loughborough, UK. Graham Hargrave, Tim Justham & Edward.
Gas Pressure Meter (Engineering World Health) Advisor: Prof. Ken Gentry Client: Prof. John Webster, Engineering World Health Engineering World Health Team.
Team Members: Allison McArton Angwei Law Jonathan Meyer Grant Smith Padraic Casserly Advisor: Dr. John G. Webster, Ph.D. Client: Engineering World Health.
Team Members: Sara Karle Ashley Matsick Michele Lorenz Emily Maslonkowski Client: Dr. Mihai Teodorescu Advisor: Prof. Mitch Tyler.
Taper DPI FeatureImpact Efficacy Safety Compliance Cost High Efficiency  Equivalent lung dose achieved in- vitro with approximately 50% lower delivered.
Problem Statement Background Final Design Future Work References Acknowledgements Joe Decker Patrick Kurkiewicz Annie Loevinger Steve Welch Client: Dr.
Electric Pressure Transducer
GCSE Revision (Section B) - Manufacturing Methods.
Components of Mechatronic Systems AUE 425 Week 2 Kerem ALTUN October 3, 2016.
PRESENTATION ON MEASUREMENT OF FLUID VELOCITY Submitted by:  Prativa Giri (072bme628)  Sutishna Pokharel(072bme646)
Author: Nurul Azyyati Sabri
Endotracheal Tube Cuff
Control System Instrumentation
Engineering World Health: Aspirator
LAL: Choice of Test Method
Intracranial Pressure Monitor
Engineering World Health: Aspirator
Introduction What is a transducer? A device which converts energy in one form to another. Transducer Active Passive Generates its own electrical voltage.
Peak Inspiratory and Expiratory Flow Meter
Analysis of Iron Experiments 3, 19 & 20.
Measuring Neonatal Lung Volume
Particle Size Analysis
Instrumented Hand Exerciser
Control System Instrumentation
Chapter 3 Administration of Aerosolized Agents
SMBE 4323 GROUP 4 NEBULIZER PRESENTED BY: 1. MUHAMAD REZA NAZRIN BIN A RAHMAN 2. LAILA FADHILLAH BINTI ULTA DELESTRI 3.GOH VOON HUEH.
Aerosol Drug Therapy Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc.
Unconventional Machining
Presentation transcript:

Mist Generator Kelly Toy Jon Cappel Joe Bothwell Abdikarim Mahamud Advisor – John Webster Client – Jack Jiang, MD, PhD tents/06.00/ asp. tents/06.00/ asp.

Overview Problem Statement Background Material Summary of product design specifications Design Alternatives considered Future Work

Problem Statement Research being conducted on the larynx can be benefited by the specific targeting of medication in the respiratory system Specific targeting of medication is difficult to complete accurately The process of atomizing particles is complex

Client Requirement -Product is needed that can: Generate a mist of different densities Generate particle sizes in the range of microns Adaptable as inhaler Generate mist such that different areas of the respiratory system can be targeted

Background Different ways to generate mist: –Ultrasonic Nebulizer –Micropumps –Pressure activated devices Particle measurement techniques

Ultrasonic Nebulizer Converts electricity into ultrasonic waves Transducer vibrates at frequency of waves (1-3 MHz) Higher the frequency, smaller droplets Transducer generates ultrasonic fountain of liquid Aerosol delivered by fan or inspiration Creates particles ~1-6 microns Dennis J, Hendrick D

Ultrasonic Nebulizer Advantages/Disadvantages Advantages Stable particle size Small dead volume High aerosol output Quiet Fast drug delivery Disadvantages Aerosol solution can become heated Expensive Short cycle life ( uses) t/ Open/

Micropumps OnQ is one of the micropumps used in the market for nebulizers. contains over a thousand precision-formed tapered holes, surrounded by a vibrational element. plate vibrates over 100,000 times per second. It draws liquid through the holes to form consistently sized droplets. Problems How to adjust the frequency.

Pressure Activated Devices Devices that create mist by using pressure – –Inhalers use a similar principle hand-held portable devices that deliver medication directly to the lungs Uses pressurized canister with chemical propellant onditions/metered_dose_inhalers.stm

Pressure Activated Devices Devices similar to hairspray bottles –Use pressure to compress liquid –Liquid is compressed through tiny opening creating mist

Pressure Activated Devices Advantages –Inexpensive –Simple Disadvantages –Comparatively, very large mist particles –Different nozzles needed for different densities

Particle measurement techniques Laser Diffraction –Method is absolute, no need to calibrate instruments –Wide range microns –Flexibility, paint nozzle sprays to dry powder –Can measure circulating liquid particles. –Requires expensive equipment –Engine research lab has a Malvern laser diffraction instrument Microscopy –Relies on microscope, and precision measuring devices. –Somewhat prone to error due to the judgment of the operator.

Particle measurement techniques Cascade impactor –Progressively filters out smaller particles through a series of tubes. –Particles accumulate according to their size, and the concentrations are analyzed after the experiment –Can take a relatively long time to complete Electrozone sensing –Changes in capacitance are measured as a charged particle flows through a small opening. –Extremely difficult/near impossible to measure sprays.

Design Alternatives 1.Modify a Nebulizer –Adjust pressure input –Adjust vibration frequency –Apply a charge to solution –Adjust opening size –Particle size selector –Requires monetary investment

Design Alternatives 2.Create our own simple device –Use the most simple aspects of fluid mechanics –Obtain an actuator, and force liquid through it at different pressures. 3.Purchase existing components –May require slight modifications –Extremely expensive

Design/Decision Matrix Nebulizer Our Device PurchaseAccuracy569 Complexity (ease of use) 583 Price571 Life span 667 Total252620

Final Design Choice Create our own simple device. –We will force liquid through different sized actuators, and experimentally determine what size and pressures will obtain the required particle size. Easy to modify if needed Relies only on pressure and actuator opening

Future Work Obtain different sized actuators Develop a method for subjecting liquid to specific pressure levels. Develop a prototype Perform experiments Analyze results.

References Basic principals of particle size measurement, Dr. Alan Rawle, Malvern Instruments limited Hess D. Nebulizers: Principles and Performance. Respiratory Care. 2 March 2004 Dennis J, Hendrick D. Design of drug nebulizers. Journal of Aerosol Science. 2000;Sep:S787-s789. this one is for picture American Academy of Asthma and Allergy Immunity m 2004 Aerogen,