EFY Design Engineers Conference 2012 Heatsink Design A practical Approach Sridevi Iyengar Global Application Engineer Sapa Profiles.

Slides:



Advertisements
Similar presentations
Conduction Conceptests
Advertisements

HVAC523 Heat Sources.
Electronics Cooling MPE 635 Mechanical Power Engineering Dept.
Electronics Cooling MPE 635
Basic Refrigeration Cycle
Using Copper Water Loop Heat Pipes to Efficiently Cool CPUs and GPUs Stephen Fried President Passive Thermal Technology, Inc.
Thermal Interface Materials Thermal Management of Electronics San José State University Mechanical Engineering Department.
Extended Surfaces Chapter Three Section 3.6.
Extended Surface Heat Transfer
TopDrive: RP3 Thermal Management of Battery Module Unit of Electronics Integration and Reliability Department of Electronics.
CHE/ME 109 Heat Transfer in Electronics LECTURE 22 – ELECTRONICS COOLING MECHANISMS.
Paul Rose European Electronics AE Manager LuxLive 2013 How to use Thermal Design Software.
Heat Transfer Overview
1 Aerospace Thermal Analysis Overview G. Nacouzi ME 155B.
Electronics Cooling Mechanical Power Engineering Dept.
Part-C Main topics B1- Electronics cooling methods in industry Heat sinks and cold plates for electronic cooling "Heat sinks" Heat pipes in electronic.
CHE/ME 109 Heat Transfer in Electronics LECTURE 7 – EXAMPLES OF CONDUCTION MODELS.
P M V Subbarao Professor Mechanical Engineering Department I I T Delhi
Modes of Heat and Mass Transfer P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi Just as Intelligent as an Human Being....
Modes of Heat Transfer P M V Subbarao Professor Mechanical Engineering Department Accounting of Natural Happenings …..
Optimal Fin Shapes & Profiles P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi Geometrical Optimization is the Basic Goal.
Lesson 15 Heat Exchangers DESCRIBE the difference in the temperature profiles for counter-flow and parallel flow heat exchangers. DESCRIBE the differences.
Solar thermal energy Eng. Elamir Ahmed. Definition of solar thermal energy  Solar thermal energy is a renewable energy source.  Solar thermal uses technology.
CPO Science Foundations of Physics
Dr Song Lin – 30. May 2012Copyright © 2012 FrigoDynamics®1 The Future of Lighting Fixture Design LED Thermal Management Cavendish Conference Centre, London.
Heat Sink Selection Thermal Management of Electronics
Design of Heat Sinks P M V Subbarao Mechanical Engineering Department IIT Delhi Success Based on Cooling Challenges …….
© 2011 Autodesk Freely licensed for use by educational institutions. Reuse and changes require a note indicating that content has been modified from the.
CHAPTER 6 Fundamentals of Thermal Management. 6.1 WHAT IS THERMAL MANAGEMENT? Resistance of electrical flow Absence of cooling Contact of Device Cooling.
STEADY HEAT TRANSFER AND THERMAL RESISTANCE NETWORKS
HEAT EXCHANGER.
INTRODUCTION Definition:
Internal Energy: The sum of all energy in a substance, potential And kinetic. This energy changes constantly in an internal Combustion engine because.
1 Denis Grondin / Julien Giraud – 01 December 2008 SLAB COOLING Denis Grondin Julien Giraud
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Heating Systems.
© International Rectifier DirectFET  MOSFETs Double Current Density In High Current DC-DC Converters With Double Sided Cooling.
Submerged PC Cooling By: Patrick Hague Geoffrey Clark Christopher Fitzgerald Group 11.
What are common results of heat transfer? Case #1, no phase transition or work done. How much does the temperature vary? Heat is energy in transit! Positive,
Heat Transfer Carlos Silva December 9 th Energy transference Energy can be transferred between a system and its surroundings Work Heat Mass flow.
By: Narendra Babu N M110247ME THERMAL ANALYSIS OF MICROPROCESSOR.
NOVEMBER 12, 2015 RIGHT NOW: GET 6.2 NOTES AGENDA: 6.2 NOTES SKILLS SHEET/HOMEWORK OBJECTIVE: DETERMINE HOW THE SUN DRIVES ATMOSPHERIC CONVECTION.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Using Thermal Energy Mrs. Nell 8 th Grade Physical Science Chapter 6 Review.
STEADY HEAT CONDUCTION IN PLANE WALLS, Ch.3
September, Modeling of LHP Temperature Control in EcosimPro F.Romera, R.Pérez, C.Gregori, E.Turrion, D.Mishkinis, A. Torres.
Genesis Technology USA, Inc. Heatsink Technologies November 2,
AFE BABALOLA UNIVERSITY
Thermally managing high power devices using heat pipe assemblies
Thermag VII, Turin, Italy
Unit 42: Heat Transfer and Combustion
Thermo-electric refrigeration.
Heat Energy.
ECE Engineering Design Thermal Considerations
Extended Surface Heat Transfer
ME390 Automotive Mechanics
UNIT - 4 HEAT TRANSFER.
Thermal analysis Friction brakes are required to transform large amounts of kinetic energy into heat over very short time periods and in the process they.
Effect of Using 2 TE units on Same Heat Sink
Dr John Fletcher Thermal Management Dr John Fletcher
FREE CONVECTION – FIXED POWER TD1005
CAPRI Cables Private Limited
THERMODYNAMIC IN ELECTRONICS
What is Fin? Fin is an extended surface, added onto a surface of a structure to enhance the rate of heat transfer from the structure. Example: The fins.
THERMODYNAMIC IN ELECTRONICS
P M V Subbarao Professor Mechanical Engineering Department I I T Delhi
Cooling System In I.C.E.
How to design the size of heatsink
Presentation transcript:

EFY Design Engineers Conference 2012 Heatsink Design A practical Approach Sridevi Iyengar Global Application Engineer Sapa Profiles

EFY Design Engineers Conference 2012 Agenda  Introduction  Heat sinks and Heat Transfer mechanisms  Why use a heatsink  Some facts you (N)ever wanted to know about heatsink  Thermal Interface materials  Liquid coolers  Friction Stir Welding

EFY Design Engineers Conference 2012 About Me – Sridevi ( Sri ) Joined Sapa in 2010 Have 10+ years of experience in electronics cooling and thermal design. Worked mostly at telecom/networking companies or consulted for projects in these areas. Thermal Analysis, thermal testing – some of my key strengths, area of expertise Icepak, Flotherm, and currently Flow Simulation are the tools I have used extensively for thermal simulations Education –B.S – Chemical Engineering – NITK Suratkal ( Karnataka Regional Engg College) –M.S - Computational fluid Dynamics – University of California San diego Passionate about South Indian Classical Music. I learn, teach and perform regularly

EFY Design Engineers Conference 2012 What is a heatsink  Heatsinks are devices that enhance heat dissipation from a component to a cooler ambient – usually air, but sometimes to other fluids as well.  The primary purpose of a heatsink is to maintain the temperature of the device being cooled within acceptable limits as specified by the component manufacturer.  Keeping the component temperature under the specified limits ensures proper operation of the device, and improves reliability and life of component.

EFY Design Engineers Conference 2012 Factors to be considered while designing heatsinks  Power that needs to be dissipated  Maximum allowable component temperature  Available space/volume for heatsink  Power density  Air Flow parameters  Pressure Drop  Bypass effects  Manufacturability  Costs

EFY Design Engineers Conference 2012 Heat sinks for air cooling Aluminium alloys are the dominating materials for air-cooled heat sinks

EFY Design Engineers Conference 2012 Thermal conductivity of Al- alloys Copper (pure): 395 W/mK

EFY Design Engineers Conference 2012 Principles of heat transfer  Heat transfer is “the science which seeks to predict the energy transfer which may take place between material bodies as a result of temperature difference  The three modes:  Conduction: Energy transfer within solids  Convection: Transfer from a surface to a moving fluid  Radiation: transfer by electromagnetic radiation

EFY Design Engineers Conference 2012 Convection Cooling Convection cooling achieved by two ways Forced Convection  Air is forced over the components with a fan or blower  The velocity of air depends on the fan and the local conditions Natural Convection or free  The buoyancy effect forces hot air to flow to the top and cold air to come to the bottom.  Typical velocity – 0.2 m/sec

EFY Design Engineers Conference 2012 Conduction

EFY Design Engineers Conference 2012 Convection

EFY Design Engineers Conference 2012 Radiation

EFY Design Engineers Conference 2012 Technical terms  Q = Total power that is dissipated by the device (s) being cooled – (W)  T j = Junction temperature of the device  T c = Case temperature of the device  T s = Heatsink temperature - Maximum temperature of the heatsink at a location closest to the device  T a = Ambient temperature

EFY Design Engineers Conference 2012 The basic equation The governing equation which correlates the total power, temperature difference and the thermal resistance can be expressed as The thermal resistance is analogous to the electrical resistance used in Ohm’s law.

EFY Design Engineers Conference 2012 Thermal Resistance Rj-c is the Junction to case thermal resistance. Usually a parameter that is published by the component manufacturer Rc-s is the thermal resistance across the thermal interface material between the heatsink and the component. Rs-a is the thermal resistance of the heatsink. = = Junction to Ambient is the sum of the resistances

EFY Design Engineers Conference 2012 Heatsink Selection Tj, Rjc and Q will be provided by the component manufacturer. Rcs – Thermal resistance of the interface material Ta – Ambient temperature Ta and Rcs are parameters that we can control to a certain extent Rsa is the number that will help us identify a heatsink that will meet our criteria.

EFY Design Engineers Conference 2012 Heatsink Design parameters  A heatsink can be optimised for performance by varying the different dimensions shown.  Of course, the optimised design should consider manufacturability.

EFY Design Engineers Conference 2012 Air-cooled heat sinks forced convection - fan curve Characteristic curve of the fan Optimal operating region High pressure-drop Low pressure-drop Air flow ∝ n (rpm) Pressure drop ∝ n 2 Noise ∝ n 3 Fan law:

EFY Design Engineers Conference 2012 Fin efficiency Apparent cooling area vs. effective cooling area Heat flow Low efficiency T_fin => T_air q = h·A ·(T hs -T air )

EFY Design Engineers Conference 2012 Bypass Effects in Forced Convection When there is a significant gap between the heatsink and the top surface of the enclosure air will bypass the heatsink. This reduces the performance of the heatsink. Bypass effect is more pronounced in heatsinks with closely packed fins. Here the air is forced to go through the heatsink and in this case the performance of the heatsink is optimised. H Heatsink Base H Heatsink Fin

EFY Design Engineers Conference 2012 α Conical fins vs. rectangular fins Heat source Conical fins seems have some advantages when only heat flow is considered Die casting always need a relief angle !

EFY Design Engineers Conference 2012 Air flow in a conical channel When both air flow and heat flow are considered, rectangular fins are better

EFY Design Engineers Conference 2012 Cooling at Altitude

EFY Design Engineers Conference 2012 Heat sink orientation natural convection gravity  The buoyancy effects of air forces hot air to move up and cold air to come down.  Orient the heatsink keeping in mind the direction of gravity  Fin thickness and fin pitch are important factors to consider while optimising the heatsink.

EFY Design Engineers Conference 2012 Comments on heat sinks used for natural convection  Optimise the fin spacing according to temperature and height.  Proper orientation of the heatsink with respect to gravity is important.  Radiation heat transfer must be considered.  Proper surface treatment is often needed as this increases the emissivity.

EFY Design Engineers Conference 2012 Heatsink Orientation Forced convection  Fluid is forced to flow over the surface by external help (Fan)  Orient the heatsink in the direction of the Airflow.  Sometimes when the flow is erratic, can use pin fin heatsinks.  In general, extruded plane fin heatsinks work better and have lesser pressure drop across the Heatsink.

EFY Design Engineers Conference 2012 Comments on Heatsinks used for forced convection  Design must take the fan curve (and by-pass flow) into account when appropriate.  Check the fin efficiency when the fin is fairly tall.  Avoid using conical fins.  Optimise the base thickness, fin thickness and fin spacing based on the expected air velocity through the channels.  Always remember that when you have more than one heatsink in the system, the airflow to the downstream heatsink will be affected by the upstream heatsinks and components.

EFY Design Engineers Conference 2012 Conduction, contact surface Heat sink Heat source Actual contact area < 2% of apparent contact area  Perfect contact can never be ensured between the heatsink and the package.  This could lead to potential problems since trapped air acts as an insulator.  The performance of the heatsink can be much lower than estimated leading to high component temperatures.  To combat this problem, it is necessary to use a thermal interface material.

EFY Design Engineers Conference 2012 Thermal interface materials – Different types  Double sided PSA  Pressure sensitive adhesive is used to adhere the heatsink to the heat source  Easy to assemble with protective liner tabs  The component package type will determine the kind of tape to use – acrylic based or silicone based  The thermal conductivity of these tapes are moderate and depends on their thermal performance depends on the contact area that can be achieved between the bonding surfaces  Typically “ thick  Not recommended when the heatsink fins are oriented vertically – i.e along the direction of gravity  Single sided PSA  Provides adhesion only to the heatsink.  Mechanical fastening of the heatsink to the component is needed.  Typically 0.05 – 0.01” thick

EFY Design Engineers Conference 2012 Thermal interface materials – Different types  Phase Change Material  Available as peel and stick pads at room temperature  When heated the material reflows to fill all the interface voids  Very good performance – high thermal conductivity  Conforms to minimize thermal path thickness  Mechanical fastening of heatsink is required  Could be messy during re-work  Gap Filler  Soft, thermally conductive silicone elastomers. Used in places where a large and variant gap exists between the components and heatsink  Typically used in places where a common heatsink is used for multiple components  Mechanical fastening of heatsink required  0.5mm – 5 mm thickness

EFY Design Engineers Conference 2012 Thermal interface materials – Different types  Epoxy  Room temperature vulcanizing materials which function both as thermal pathway and mechanical attachment  Not favored by assemblers due to the possible prep work and inability to rework  Grease  Excellent thermal conductivity and void filling capability  Mechanical attachment of heatsink to component required  Can be messy and not favored by assemblers  Can be as thin as 0.01”

EFY Design Engineers Conference 2012 What Next  At some point one reaches the limit of Air cooling.  You may enhance the performance of the heatsinks with different techniques like, serrated fins, bonded fins, Skived fins.  Heatpipe heatsinks, Vapor chamber and Liquid cooled heatsinks are the next generation of thermal management products when Air cooled heatsinks just will not do the job for you.

EFY Design Engineers Conference 2012 Heat pipe Heat out Condense returning (by capillary) Heat in wick Vapour flow

EFY Design Engineers Conference 2012 Heat pipes

EFY Design Engineers Conference 2012 What is “liquid cooling”?  Conventional definition in automotive analogy  Circulating fluid driven by pump  Heat absorbed at source by “cold plate! Or “water block”  Heat rejected to ambient by “heat exchanger” or “radiator”  Multiple heat sources possible in series or parallel  May also include two phase flow, evaporating at heat source, e.g.  Heat pipe  Thermsyphon

EFY Design Engineers Conference 2012 Liquid cooling: Channel design is important. Heat source 30 Heat source

EFY Design Engineers Conference 2012 Liquid cooling: temperature & flow Sapa’s channel“Star channel”

EFY Design Engineers Conference 2012 Disadvantages of liquid cooling: System becomes more complex  Add significant complexity: more parts and more units being involved  Pump reliability  Low heat flux parts still need cooling with heatsinks/Fans  Investment required for testing and verifying system performance  Still need to remove heat from liquid system to ambient air (or other liquid)  In general, liquid cooling units will require more real estate.

EFY Design Engineers Conference 2012 Some comments on liquid cooling  Channel design is important.  Contact thermal resistance between component and heat sink may becomes significant.  The choices of liquid (coolant) depends on single phase or two phase.

EFY Design Engineers Conference 2012 Friction stir welding A rotating tool is plunged into the joint line and moved along the joint. Neither flux nor filler material are used. Friction Stir welding method of joining is based on the fact that the metal is subjected to heavy plastic deformation at high temperatures, but lower than the melting point. When the rotating tool is plunged into the metal, friction heat is generated. The tool produces severe plastic deformation under high pressure, during which the weld interfaces are stirred together and a homogenous structure is formed. Process results in completely pore-free,tight joints with a high strength Minimum heat influence on the material Good mechanical properties

EFY Design Engineers Conference 2012 Friction Stir Welding

EFY Design Engineers Conference 2012 Final Thoughts  Global market for Electronic Thermal management is forecasted to reach $8.6 billion by  Miniaturization of products along with increase in features is leading to higher power dissipations and more importantly power density  Upfront, well thought out thermal design will eliminate thermal related problems at later stages. At this time there might be no recourse or if there is one, it might be an expensive one.  Working closely with your thermal solutions provider will ensure you have a solid thermal solution for your electronic product.

EFY Design Engineers Conference 2012 Sapa’s offer to you...

EFY Design Engineers Conference 2012 Thank You Feel free to contact me if you think I can be of any help. 91 – Some websites that I visit for information on thermal design – –