Mehran University College Of Engineering & Technology, Khairpur Mir’s

Slides:



Advertisements
Similar presentations
Chapter 4 Transformer Connections
Advertisements

ECE Electric Drives Topic 6: Voltage-Fed Converters Spring 2004.
Announcements Be reading Chapters 8 and 9
ENERGY CONVERSION ONE (Course 25741)
ARRDEKTA INSTITUTE OF TECHNOLOGY ♦ GUIDED BY ♦ Prof. D.R.PATE Asst.prof in electrical Department PREPARED BY PREPARED BY RATHOD VISHANU. RATHOD VISHANU.
BASIC ELECTRICAL TECHNOLOGY Chapter 3 - Three Phase System
Review of 1- AC Circuit Fundamentals
ECE 4411 Introduction to Three-Phase Power. ECE 4412 Typical Transformer Yard.
1 EE 306 TRANSFORMERS Instructor: Dr. Mahamed Shwehdi Done By: Ahmad Saleh Al-Owied.
Balanced Three-Phase Circuits
Universal College of Engineering & Technology
electronics fundamentals
Chapter 12 Three Phase Circuits
Unit 27 Three-Phase Circuits
EET 103 Chapter 3 (Lecture 1) Three Phase System.
บทที่ 7 Three-phase Transformers
Mehran University College Of Engineering & Technology, Khairpur Mir’s ENGR. AHSANULLAH MEMON LECTURER DEPARTMENT OF ELECTRICAL ENGINEERING MUCET KHAIRPUR.
Transformer with open secondary.
Unit 29 Three-Phase Transformers. Objectives: Discuss the construction of three-phase transformers. Discuss the formation of a three-phase transformer.
Transformers.
Balanced Three-Phase Circuits and Ideal Transformers ELEC 308 Elements of Electrical Engineering Dr. Ron Hayne Images Courtesy of Allan Hambley and Prentice-Hall.
EQUIVALENT CIRCUIT AND POWER EQUATION OF SYNCHRONOUS MOTOR
Mehran University Of Engineering & Technology, SZAB Khairpur Mirs Campus ENGR. AHSANULLAH MEMON LECTURER DEPARTMENT OF ELECTRICAL ENGINEERING MUCET KHAIRPUR.
Department of Electrical and Computer Engineering
Universal college of engineering and technology  C.P.D. SUBJECT:- DC Machine & Transformer ELECTRICAL ENGG. DEPARTMENT.
1.6 Real Single-Phase Transformer.
1 © ABB AB, Application of Unit Protection Schemes for Auto-Transformers Zoran Gajić ABB AB Vasteras, Sweden Authors: Z. Gajić, ABB Sweden.
1 ELECTRICAL CIRCUIT ET 201  Become familiar with the operation of a three phase generator and the magnitude and phase relationship.  Be able to calculate.
Power System Fundamentals EE 317 Lecture 7 20 October 2010.
Elec467 Power Machines & Transformers
Transformer Protection Over-current protection in the form of fuses may be the only protection provided to a small 100 kVA, 11 kV/440 V distribution transformer.
Chapter 2 Transformers Edit by Chi-Shan Yu Electric Machinery.
THREE PHASE POWER Generation Transportation Consumption.
Lecture 11Electro Mechanical System1 Delta-Delta Connection  Three single-phase transformers connected delta-delta  H 1 terminal of each transformer.
General power system. objective Review general energy and power system Application of fundamental knowledge of principal machines, transformer and other.
Lecture II Objective: Representation of sequence components
Mehran University Of Engineering & Technology, SZAB Khairpur Mirs Campus ENGR. AHSANULLAH MEMON LECTURER DEPARTMENT OF ELECTRICAL ENGINEERING MUCET KHAIRPUR.
SMJE 2103 Electrical Power System 3- Ph Power Apparatus.
D.C. Machine & Transformer Topic: Instrument Transformer Electrical:-1 presented by: Jill Chauhan ( ) Chirag Agarawal ( )
1 :. Introduction These are special type of transformers used for the measurement of voltage, current, power and energy. As the name suggests, these transformers.
Determining Transformer Phase Angle Displacement.
Gandhinagar Institute of Technology
PREPARED BY, ENROLLMENT NO: CLASS: 3 RD E&C Transformer 1 3-Ø Transformer Hansaba College of Engineering & Technology, Sidhpur.
Mehran University Of Engineering & Technology, SZAB Khairpur Mirs Campus ENGR. AHSANULLAH MEMON LECTURER DEPARTMENT OF ELECTRICAL ENGINEERING MUCET KHAIRPUR.
Transformers. Single Phase Transformers Principles of Operation – Single Phase.
1. 2 Magnetization Current in a Real transformer Although the output of the transformer is open circuit, there will still be current flow in the primary.
ET 332b Ac Motors, Generators and Power Systems 1 Lesson 11_et332b.pptx.
THREE-PHASE TRANSFORMER
CHAPTER 6 SPECIAL TRANSFORMERS Electrical Machines.
By Mr. S. SURESH KUMAR (09A91A0241) Mr. P. SAI SANDEEP (09A91A0237) Mr
DC MACHINE AND tRANSFORMER
3-Phase Transformer Construction, Principal, Working, Operation Advantages Over 1-Phase Transformer Introduction Advatages Construction Principal Working.
Principle of Operation
Ahmedabad Institute of Technology
Lesson 4: Three Phase Sources and Loads
ELECTRONICS & COMMUNICATION 3-SEM SHANTILAL DHOLIYA ( )
Electrical Machine-I EE 2107 Dr. Md. Sherajul Islam
Transformers. Transformer An A.C. device used to change high voltage low current A.C. into low voltage high current A.C. and vice-versa without changing.
Energy Conversion and Transport George G. Karady & Keith Holbert
Three Phase Transformers
PARALLEL OPERATION OF SINGLE PHASE TRANSFORMER
Lesson 11: Transformer Name Plate Data and Connections
3-Phase Transformer Construction, Principal, Working, Operation Advantages Over 1-Phase Transformer Introduction Advatages Construction Principal Working.
Electrical Engineering Principle DNT 235/3
TRANSFORMERS.
Principle of Operation
Three-Phase Transformers
Three Phase Transformers
BALANCE THREE PHASE SYSTEM
Unit-1 Transformer.
Presentation transcript:

Mehran University College Of Engineering & Technology, Khairpur Mir’s THREE PHASE TRANSFORMERS AND VECTOR GROUPS ENGR. AHSANULLAH MEMON LECTURER DEPARTMENT OF ELECTRICAL ENGINEERING MUCET KHAIRPUR MIRS

THREE PHASE TRANSFORMERS A three phase transformer has three sets of primary and secondary windings. Depending upon how these sets of windings are interconnected, determines whether the connection is a star or delta configuration. The available voltage which are each displaced from the other by 120 electrical degrees H.W:- Advantages and disadvantages of core type construction and shell type construction

CONNECTIONS OF THREE PHASE TRANSFORMERS A three-phase transformer is made of three sets of primary and secondary windings. Those sets of primary and secondary windings will be connected in either Δ or Y configurations to form a complete unit. Y connections provide the opportunity for multiple voltages, while Δ connections enjoy a higher level of reliability (if one winding fails open, the other two can still maintain full line voltages to the load). Primary - Secondary     Y       -           Y     Y       -           Δ     Δ       -           Y   Δ       -           Δ

Having both primary and secondary winding sets connected in “Y” formations allows for the use of neutral conductors (N1 and N2) in each power system.

Such a configuration would allow for the provision of multiple voltages (line-to-line or line-to-neutral)

When there is no need for a neutral conductor in the secondary power system, Δ-Δ connection schemes are preferred because of the inherent reliability of the Δ configuration. Considering that a Δ configuration can operate satisfactorily missing one winding, some power system designers choose to create a three-phase transformer bank with only two transformers, representing a Δ-Δ configuration with a missing winding in both the primary and secondary sides:

Vector Group of Transformer The three phase transformer windings can be connected several ways. Based on the windings’ connection, the vector group of the transformer is determined. The transformer vector group is indicated on the Name Plate of transformer by the manufacturer. The vector group provides a simple way of indicating how the internal connections of a transformer are arranged. The vector group indicates the phase difference between the primary and secondary sides, introduced due to that particular configuration of transformer windings connection. The Determination of vector group of transformers is very important before connecting two or more transformers in parallel. If two transformers of different vector groups are connected in parallel then phase difference exist between the secondary of the transformers and large circulating current flows between the two transformers which is very detrimental.

The vector group is indicated by a code consisting of two or three letters, followed by one or two numeric digits. The letters indicate the winding configuration as follows: D or d: Delta winding, also called a mesh winding. Y or y: Wye winding, (also called a star). Z or z: Zigzag winding, or interconnected star winding. Similar to a wye winding, but two windings form each phase are arranged so that the three legs are "bent" when the phase diagram is drawn. Zigzag-wound transformers have special characteristics and are not commonly used where these characteristics are not needed.

ZIGZAG CONNECTION OF TRANSFORMER The zigzag connection of tranformer is also called the interconnected star connection.  This connection has some of the features of the Y and the ∆ connections, combining the advantages of both. The zigzag transformer contains six coils on three cores. Its applications are for the deviation of a neutral connection from an ungrounded 3-phase system and the grounding of that neutral to an earth reference point and harmonics mitigation. It can cancel triplet (3rd, 9th, 15th, 21st, etc.) harmonic currents.

The digits (0, 1, 11 etc) relate to the phase displacement between the HV and LV windings using a clock face notation. The phasor representing the HV winding is taken as reference and set at 12 o’clock. Phase rotation is always anti-clockwise. (International adopted). Use the hour indicator as the indicating phase displacement angle. Because there are 12 hours on a clock, and a circle consists out of 360°, each hour represents 30°. Thus 1 = 30°, 2 = 60°, 3 = 90°, 6 = 180° and 12 = 0° or 360°. Example: Digit 0 =0° that the LV phasor is in phase with the HV phasor Digit 1 =30° lagging (LV lags HV with 30°) Digit 11 = 330° lagging or 30° leading (LV leads HV with 30°) Digit 5 = 150° lagging (LV lags HV with 150°) Digit 6 = 180° lagging (LV lags HV with 180°)