TRAINING COURSE on radiation dosimetry:

Slides:



Advertisements
Similar presentations
Chapter 4 Radiation Dosimeters
Advertisements

NUCP 2371 Radiation Measurements II
General Characteristics of Gas Detectors
Radiation Detection ionization chambers (dosimeters, pulse chambers, particle track chambers) scintillation detectors semiconductor detectors photographic.
Beam Composition for Biology
GM COUNTER.
Ion Beam Analysis techniques:
Geiger-Muller detector and Ionization chamber
Radiation Detectors / Particle Detectors
Radiation Units & Quantities
Charged Particle Radiation
10-1 CHEM 312 Lecture 10: Part 1 Radiation Reactions: Dosimetry and Hot Atom Chemistry Readings: §Reading: Modern Nuclear Chemistry, Chap. 17; Nuclear.
Radiation Exposure, Dose and Relative Biological Effectiveness in Medicine Background Image:
Neutral Particles. Neutrons Neutrons are like neutral protons. –Mass is 1% larger –Interacts strongly Neutral charge complicates detection Neutron lifetime.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
Particle Interactions
Quantities and Measurements - 2 Dosimetric Quantities
Techniques for detecting X-rays and gamma-rays Pair production Creation of elementary particle and its antiparticle from a photon. Occurs only if enough.
Radiation Dosimetry Dose Calculations D, LET & H can frequently be obtained reliably by calculations: Alpha & low – Energy Beta Emitters Distributed in.
Alexander Brandl ERHS 630 Exposure and Dose Environmental and Radiological Health Sciences.
TRAINING COURSE ON RADIATION DOSIMETRY: Instrumentation 1 – Gas detectors / Part 1 Anthony WAKER, University of Ontario Instutute of Technology Wed. 21/11/2012,
4/2003 Rev 2 II.3.1 – slide 1 of 30 Part IIQuantities and Measurements Module 3Principles of Radiation Detection and Measurement Session 1Ionization Chambers.
Radiology is concerned with the application of radiation to the human body for diagnostically and therapeutically purposes. This requires an understanding.
Detectors The energy loss of particles in matter can be used detect and identify those particles. There are different types of “detectors”: - Gas-filled.
Photon and Energy Fluence
3/2003 Rev 1 II.2.9b – slide 1 of 40 IAEA Post Graduate Educational Course Radiation Protection and Safe Use of Radiation Sources Part IIQuantities and.
Instruments for Radiation Detection and Measurement Lab # 3 (1)
2 nd ANNUAL ARDENT WORKSHOP Quality assessment of hadrontherapy fields with TEPCs Paolo Colautti, INFN 2 nd Annual ARDENT Workshop, Milano, October.
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
Dose Distribution and Scatter Analysis
Stopping Power The linear stopping power S for charged particles in a given absorber is simply defined as the differential energy loss for that particle.
Type of Material: Instrumentation Review
SOI detector Geant4-based studies to characterise the tissue-equivalence of SOI and diamond microdosimeteric detectors, under development at CMRP S. Dowdell,
FISICA AMBIENTALE 1 Radioattività: misure 1 Lezioni Marie Curie.
Tools for Nuclear & Particle Physics Experimental Background.
Space Instrumentation. Definition How do we measure these particles? h p+p+ e-e- Device Signal Source.
Mass Spectroscopy 1 Mass Spectroscopy (Mass Spec) Applying Atomic Structure Knowledge to Chemical Analysis.
Instrumentation Review. Direct and Indirect Ionization Direct - Charge particles that strip away electrons from atoms Indirect - uncharged that have to.
ARDENT Advanced Radiation Dosimetry European Network Training initiative WP1: Gas Detectors S. Rollet.
2. RUTHERFORD BACKSCATTERING SPECTROMETRY Basic Principles.
Ionization Detectors Basic operation
TUDelft-IRI-ST A new Tissue-Equivalent Proportional Counter design M. Farahmand, A.J.J. Bos, J. Huizenga and C.W.E. van Eijk Radiation Technology Group,
3/2003 Rev 1 II.1.2 – slide 1 of 32 IAEA Post Graduate Educational Course Radiation Protection and Safe Use of Radiation Sources Session II.1.2 Part IIQuantities.
Chapter 5 Interactions of Ionizing Radiation. Ionization The process by which a neutral atom acquires a positive or a negative charge Directly ionizing.
Determining Radiation Intensity
Nuclear Physics Nuclei atomic number Z = protons
PHYSICS 225, 2 ND YEAR LAB NUCLEAR RADIATION DETECTORS G.F. West Thurs, Jan. 19.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
3/2003 Rev 1 II.2.9a – slide 1 of 25 IAEA Post Graduate Educational Course Radiation Protection and Safe Use of Radiation Sources Part IIQuantities and.
INTERACTIONS OF RADIATION WITH MATTER. twCshttp:// twCs
Chapter V Radiation Detectors.
Geiger-Mueller Counters Darwin L. Boyd Kent State University School of Technology.
1 A protocol for the determination of absorbed dose from high energy photon and electron beams AAPM TG-21 Protocol (Med Phys 10: , 1983) 和信治癌中心醫院.
Chapter 2 Radiation Interactions with Matter East China Institute of Technology School of Nuclear Engineering and Technology LIU Yi-Bao Wang Ling.
Linear Energy Transfer and Relative Biological Effectiveness
From Microdosimetry to Nanodosimetry
INTERACTION OF PARTICLES WITH MATTER
Dr: Mohamed Afifi By Lecturer Radiological Science
Gas Detectors for Neutron Dosimetry and Monitoring
Interactions of Radiation With Matter
Arghya Chattaraj, T. Palani Selvam, D. Datta
Witold Matysiak (University of Florida Proton Therapy Institute)
Ionization detectors ∆
核子醫學技術學實驗 Radioactivity measurement, Dose Calibrator
1. Introduction Secondary Heavy charged particle (fragment) production
Chapter 8 (Part 1) Measurement of Absorbed Dose
Ch6 Measurement of Ionizing Radiation
PHYS 3446, Spring 2012 Andrew Brandt
Presentation transcript:

TRAINING COURSE on radiation dosimetry: Gas Detectors for Microdosimetry A.J. Waker, UOIT 20 November, 2012

Fundamentals of Gas-Filled Detectors One of the oldest and most widely used radiation detector types Gas-filled detectors respond to the direct ionization created by charged particles set in motion by the interaction of the radiation field with the chamber gas Ion Chambers Proportional Counters Geiger-Mueller Counters

Fundamentals - Ionization in Gases To create an ion pair, a minimum energy equal to the ionization energy of the gas molecule must be transferred Ionization energy between 10 to 25 eV for least tightly bound electron shells for gases of interest in radiation detection Competing mechanisms such as excitation leads to incident particle energy loss without the creation of ion pair W-value: average energy lost by incident particle per ion pair formed b/c incident particle also loses energy by other mechanisms, ex. excitation Typical W-values are in the range of 25 – 35 eV/ion pair

Fundamentals - Basic Components Basic elements of I.C. - enclosed volume of gas in region where E-field is applied by an external voltage. Basic process – radiation interacts with gas molecules generating e-ion pairs. E-field separates positive and negative (e) ions and are collected at the electrodes. Measuring the current generated by these pairs – IONIZATION CURRENT due to radiation interaction with sensitive gas volume. Common Fill Gases: Ar, He, H2, N2, Air, O2, CH4, TE

Fundamentals – What is Measured? 𝐷 𝑚𝑎𝑡𝑡𝑒𝑟 = 𝐷 𝑐𝑎𝑣𝑖𝑡𝑦 . 𝑆 𝜌 𝑚𝑎𝑡𝑡𝑒𝑟 𝑐𝑎𝑣𝑖𝑡𝑦 The charge generated in a gas-filled detector depends on: The gas used The material surrounding the gas The characteristics of the radiation field

Ionization Chambers in Experimental Microdosimetry Ionization chambers have played an important niche role in experimental microdosimetry particularly for situations where nanometric site-sizes have been of interest or where high dose-rates have excluded the pulse-height measurement technique Variance Methods Single chamber (variance) Twin chambers (variance – covariance) Based on the repeated measurement of charged collected in a given time interval and the relationship between the dose mean specific energy for single events, the relative variance for multiple events and the mean specific energy per time interval 𝑍 𝐷 =𝑉 𝑧 . 𝑍 Kellerer and Rossi: RADIATION RESEARCH 97, 237-245 (1984) Lillhok, Grindborg, Lindborg et. al. Phys. Med. Biol. 52, 4953-4966, (2007) Recombination Chambers High pressure ionization chambers Based on the difference of ionization current measured at two different collection voltages and the degree of columnar recombination in individual particle tracks. Makrigiorgos and Waker: Phys. Med. Biol. 31, No 5, 543-554 (1986) Golnik: Radiat. Prot. Dosim. No 1-4, 211-214 (1997)

Proportional Counters in Experimental Microdosimetry Operating Principle Tissue Equivalent (TEPC) Other Counter Types Multi-element Wall-Less Heterogeneous Saad Al Bayati; MASc. Thesis, UOIT, 2012

Proportional Counters – Operating Principle A proportional counter is a gas-ionization device consisting of a cathode, thin anode wire and fill-gas. Charge produced by ionization in the fill gas is multiplied providing an amplified signal proportional to the original ionization. Multiplication (gas-gain) depends on the fill-gas, applied voltage and detector geometry With sufficient gas-gain the energy deposited by individual charged particle tracks can be recorded as a pulse-height single-event spectrum Propane TE Gas 6.5 torr

Proportional Counters – Tissue Equivalent Walls 𝐷 𝑚𝑎𝑡𝑡𝑒𝑟 = 𝐷 𝑐𝑎𝑣𝑖𝑡𝑦 . 𝑆 𝜌 𝑚𝑎𝑡𝑡𝑒𝑟 𝑐𝑎𝑣𝑖𝑡𝑦 For tissue equivalent walls and gas (homogeneous counters) the stopping power ratio is unity and absorbed dose in wall is given by the absorbed dose to the gas cavity A150 TE-plastic atomic composition by % weight H C N O muscle (10.2) (12.3) (3.5) (72.9) 10.1 77.6 3.5 5.2

Proportional Counters – Tissue Equivalent Gases Methane based CH4 (64.4% partial pressure) CO2 (32.4% partial pressure) N2 (3.2% partial pressure) By %weight: H (10.2); C (45.6); N (3.5); O (40.7) Propane based C3H8 (55% partial pressure) CO2 (39.6% partial pressure) N2 (5.4% partial pressure) By %weight: H (10.3); C (56.9); N (3.5); O (29.3) H C N O 10.2 12.3 3.5 72.9 ICRU Tissue (Muscle) atomic composition by % weight

Proportional Counters – Microscopic Site-Size Simulation Et Eg The density of the gas in the cavity is adjusted to equal the ratio of the tissue site diameter to the gas cavity diameter Density of Gas Diameter of Gas Cavity Density of Tissue Site (1000 kg.m-3) Diameter of Tissue Site

Proportional Counters – TEPC Applications TEPC - Measurable Quantities Absorbed dose Mean Quality factor Dose equivalent Microdosimetric averages TEPC - LET Spectrometry Radiation Field Analysis Charge Particle Identification TEPC - Differential Dosimetry Measurement of Kerma Factors Boron Neutron Capture Dose

TEPC Measureable Quantities – Absorbed Dose Fraction of dose per log interval of Lineal Energy yf(y) vs d(logy) yd(y) Saad Al Bayati; MASc. Thesis, UOIT, 2012

TEPC Measureable Quantities – Absorbed Dose The absorbed dose to the counter gas cavity is derived from the measured yd(y) event-size spectrum: 𝐷= 𝑒𝑛𝑒𝑟𝑔𝑦 𝑑𝑒𝑝𝑜𝑠𝑖𝑡𝑒𝑑 [𝐽] 𝑚𝑎𝑠𝑠 𝑜𝑓 𝑔𝑎𝑠 𝑘𝑔 𝐷= 𝑖 𝑦 𝑖 𝑑 𝑦 𝑘𝑒𝑉/µ𝑚 𝑥 𝑙 [𝑘𝑒𝑉/µ𝑚] 𝜌 𝑔 𝑥 𝑉 1.602 E−16 [𝐽/𝑘𝑒𝑉]

Measureable Quantities – Quality Factors From ICRP 60

Measureable Quantities – Dose Equivalent 𝐻=𝐷. 𝑄 Dose to the gas cavity calculated directly from the measured event-size spectrum Determined from the shape of the event-size spectrum and assuming Q(y) = Q(L)

Measureable Quantities – Dose Equivalent Response For neutron s the measured quantity, dose-equivalent to the gas-cavity is often compared to the operational quantity Ambient Dose Equivalent H*(10). The dose equivalent response of the TEPC, defined as H/H*(10), is a function of neutron energy and is found to be close to unity for neutron fields greater than 1 MeV and for thermal neutrons, but significantly less than 1.0 for neutrons of a few hundred keV and below.

Measureable Quantities – Dose Equivalent Response Nunes and Waker, Radiat. Prot. Dosim. 59, No 4, 279-284, 1995

Measureable Quantities – Microdosimetric Averages Microdosimetric averages such as the frequency mean and dose mean lineal energy are important measures of radiation quality for characterising radiation fields and therapy beams in terms of their potential biological effect. These quantities are directly derivable from measured event-size spectra using TEPCs

Measureable Quantities – Microdosimetric Averages

TEPC – LET Spectrometry Recognizable features of an event-size spectrum enable us to identify and analyse radiation fields

LET Spectrometry– Radiation Field Analysis The position of ‘peaks’ and ‘edges’ can tell us something about the energy of the radiation and gives us fixed event-sizes for calibration Saad Al Bayati; MASc. Thesis, UOIT, 2012

LET Spectrometry – Radiation Field Analysis Similarly, photon fields can be identified by the position of ‘peaks’ and ‘edges’ in the event-size spectrum.

LET Spectrometry – Charged Particle Identification Mixed field neutron -gamma dosimetry can be carried out by the identification of ‘low LET’ electrons and ‘high LET’ protons Saad Al Bayati; MASc. Thesis, UOIT, 2012

Differential Dosimetry - Kerma Factors Differences between microdosimetric spectra obtained with counters with wall-materials different in one element can provide information on the kerma per unit fluence for that element DeLuca et al. Radiat. Prot. Dosim. 23 Nos 1-4, 27-30, 1988

Differential Dosimetry - BNCT Differences between microdosimetric spectra obtained with counters with wall-materials having different boron concentrations can provide information on the dosimetric impact of boron capture in a given neutron field Waker , Burmeister et al, Radiat. Prot. Dosim., 99, No 1-4, 311-316, 2002

Other Counter Types – Multi-Element To increase the sensitivity of a TEPC we need to increase the surface area of the wall either by: Increasing the diameter of the counter Constructing a multi-element device

Other Counter Types – Multi-Element Counters Waker, Aslam and Lori; Radiat. Prot. Dosim, 2010

Other Counter Types – Multi-Element Using coincidence techniques to distinguish between energetic charged particles and neutrons in high energy ion beams or Space radiation environment Matysiak , Hanu and Waker, PTCOG51, 2012

Other Counter Types– Wall-Less Measurement of dose mean specific energy avoiding the distortions introduced by ‘wall-effects’ due to the difference in density between the solid TE wall and the TE gas cavity Topics in Radiation Dosimetry – Supplement 1. F. Attix, Academic Press, 1972

Other Counter Types– Wall-Less Tsuda et. al. Phys. Med. Biol., 55, 5089-5101, 2010

Other Counter Types – Heterogeneous Graphite counter used in mixed field dosimetry Saad Al Bayati; MASc. Thesis, UOIT, 2012

Future Needs and Challenges Size and sensitivity Calibration Signal Processing

Acknowledgements Many thanks to the following: Saad Al-Bayati The Natural Sciences and Engineering Research Council of Canada (NSERC) University Network of Excellence in Nuclear Engineering (UNENE)