Hydrostatic Level Systems at Fermilab and SURF J Volk V Shiltsev Fermilab A Chupyra M Kondaurov S Singatulin Budker Institute of Nuclear Physics D Fratta, A Meulemans, C Potier, H Wang University of Wisconsin Madison
Systems NameLocationSensor typeNumber of sensors separation MINOS-2MINOS hall Fermilab SAS-E1010 m LaFargeNorth Aurora Ill SAS530 m Array CSURF Lead South Dakota SAS-E630 m NMLNML Fermilab SAS4Varies MP7MP7 FermilabULSE320 m Stability testMP8 FermilabSAS12 MT ULSEMP8 FermilabULSE121 m Sept 13, 2012IWAA 20122
MINOS layout Sept 13, 2012IWAA MINOS Detector Nova Cavern under construction
MINOS-2 Sept 13, 2012IWAA 20124
Typical MINOS data August 2012 Sept 13, 2012IWAA 20125
Sept 13, 2012IWAA 20126
MINSO Data Feb 12 to Aug 31 Sept 13, 2012IWAA 20127
Array C layout Sept 13, 2012IWAA 20128
HLS at 2000 ft level on rock bolt shelf Rock bolt Sensor Air line Water line Sept 13, 2012IWAA 20129
Difference in two sensors 2000 ft level SURF Sept 13, 2012IWAA
Difference in two sensors 60 meters apart SURF 2000 foot level Sept 13, 2012IWAA
LaFarge Mine Sept 13, 2012IWAA
LBNE beam line Sept 13, 2012IWAA