A Proposal of Standard Calibration Laboratory for RICs Yizhuo Sha (National Centre for Meteorological Metrology, Atmospheric Observation Technology Centre,

Slides:



Advertisements
Similar presentations
Meteorological Observatory Lindenberg – Richard Assmann Observatory The GCOS Reference Upper Air Network.
Advertisements

Copyright Alan Rowley Associates Steps to an Accurate Result Select a method and validate it as suitable for the purpose envisaged. Establish that.
Twinning Project RO2006/IB/EN/09 1 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest Wolfgang Garche Saxony-Anhalt.
Radiative Atmospheric Divergence using ARM Mobile Facility, GERB data and AMMA stations A proposal led by Tony Slingo to deploy the new ARM Mobile Facility.
1 Forecasting the Weather. Weather Weather: The daily conditions of a particular area: temp, rain, pressure, wind, etc.Weather: The daily conditions of.
Selection of measuring instruments
Thermometers Thermometers measure air temperature. Thermometers work because matter expands when heated. Most thermometers are closed glass tubes containing.
Weather Instruments.
AOSC 200 Lesson 5. Observing the Atmosphere There are several instruments that are used to measure the basic atmospheric variables/ Temperature – Thermometer.
Short Course on Introduction to Meteorological Instrumentation and Observations Techniques QA and QC Procedures Short Course on Introduction to Meteorological.
Classification of Instruments :
Miruna DOBRE – SMD (Belgium) Stephanie BELL – NPL (United Kingdom) Dolores del CAMPO – CEM (Spain) Martti HEINONEN - MIKES (Finland)
© NMISA 2010 INTERNATIONAL ACTIVITIES AT THE NMISA HUMIDITY LABORATORY DURING 2009/2010 Deona Jonker.
By ANJIT ANJAN Meteorologist India Meteorological Department India TECO-2008.
 How do weather conditions affect your daily life? For some people, it's not just a matter of getting through traffic, but surviving.  meteorology,
Weather Instrumentation 7 th Grade Science Mr. Bombick.
CENTRE OF EXCELLENCE (CHEMICAL SECTOR)
Weather Tools & Measurements Weather Administration.
Ensuring of Traceability
REGIONAL INSTRUMENT CENTRE: REVIEW AND STRENGTHENING Dr Jérôme DUVERNOY
KINGDOM OF MOROCCO National Meteorological Service of Morocco MOROCCAN WIGOS DEMONSTRATION PROJECT 1 STANDARDIZATION AND TRACEABILITY OF THE MOROCCAN METEOROLOGICAL.
A FIRST REVIEW OF CALIBRATION DEVICES ACCEPTABLE FOR METROLOGY LABORATORY Mr Drago GROSELJ Dr Jérôme DUVERNOY Dr John GORMAN
Weather Variables.
European Metrology Research Program (EMRP) MeteoMet Project (October 2011) WP3. Traceable measurements methods and protocols for ground based meteorological.
Meteorological Observatory Lindenberg – Richard Assmann Observatory The GCOS Reference Upper Air Network.
Section 12.3 Gathering Weather Data
Chapter 2, Lesson 3.  A weather forecast is a prediction of weather conditions over the next 3 to 5 days.  A meteorologist is a person who observes.
Weather Instruments. The weather forecast that helped you plan activities for this week was probably made by a meteorologist. A meteorologist is a person.
Weather Instruments. Thermometer What does it do? What does it do? It measures the air temperature It measures the air temperature.
Documentation of surface observation. Classification for siting and performance characteristics Michel Leroy, Météo-France.
MEASUREMENT OF VOLUME. OVERVIEW First some general principles Then, more detail about micropipettes.
Tools for Predicting Weather Predicting Weather  Observation: process of watching and noting what occurs.  Prediction: proposed explanation based on.
How Do Forests, Agriculture and Residential Neighborhoods Interact with Climate? Andrew Ouimette, Lucie Lepine, Mary Martin, Scott Ollinger Earth Systems.
Lecture 3 Mechanical Measurement and Instrumentation MECN 4600 Department of Mechanical Engineering Inter American University of Puerto Rico Bayamon Campus.
Ping Zhu, AHC5 234, Office Hours: M/W/F 10AM - 12 PM, or by appointment M/W/F,
What are they? What do they do?
How Do Forests, Agriculture and Residential Neighborhoods Interact with Climate? Andrew Ouimette, Lucie Lepine, Mary Martin, Scott Ollinger Earth Systems.
Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM.
INTERCOMPARISON BETWEEN RA VI ( France, ) AND RA II (Australia) REGIONAL INSTRUMENT CENTRES ENVIRONMENTAL AGENGY OF THE REPUBLIC OF SLOVENIA Slovakia,
Meteorological Observatory Lindenberg Results of the Measurement Strategy of the GCOS Reference Upper Air Network (GRUAN) Holger Vömel, GRUAN.
Arctic Circle 2015, October 16-18, Reykjavík - Iceland MeteoMet Project: Metrology Activities in Ny-Ålesund (Svalbard) Chiara Musacchio Istituto Nazionale.
Weather and Climate. Introduction Before the end of June 2011, the National Oceanic and Atmospheric Administration (NOAA) officially declared the year.
Chapter 5 Predicting Weather.
Chapter 11 Heating the Atmosphere. Weather versus Climate  Weather  Atmospheric conditions over a short period of time  Constantly changing  Climate.
The Measurement of Temperature
Weather Instruments.
Metrology within Meteorology. METROLOGY PYRAMID METROLOGY LABORATORIES MANUFACTURERS / PUBLIC NATIONAL LABORATORY BIPM.
Temperature Rainfall Wind WEATHER AND CLIMATE. Relevance of Weather.
Aneroid Barometer  Advantages: l No liquid l Easily portable l Low weight l Adaptable to recording  Disadvantages: l Less precise or accurate as a mercury.
Instrument Characteristics  Scientific Instrument: l A device for making a measurement.  Measurement: l An action intended to assign a number as the.
Forecasting the Weather 6/8/16. Weather Forecast  Prediction of weather conditions over the next 3 to 5 days  Meteorologist: person who observes and.
Establishing by the laboratory of the functional requirements for uncertainty of measurements of each examination procedure Ioannis Sitaras.
National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce Power Loading Effects in Precision 1  Resistors.
Weather Tools & Measurements
Weather Instruments.
AMEK 2013 SCIENTIFIC CONFERENCE & EXHIBITION
What are they? What do they do?
What are they? What do they do?
Weather.
A.Liudchik, V.Pakatashkin, S.Umreika, S.Barodka
Weather Instruments.
Weather Instruments.
Weather Instruments.
Meteorological Instruments
VISUAL AIDS for instruction in VACUUM TECHNOLOGY AND APPLICATIONS
Section 3: Gathering Weather Data
Weather.
Weather Instruments.
Unit 2: “Earth and Space Science”
Weather Instruments.
Presentation transcript:

A Proposal of Standard Calibration Laboratory for RICs Yizhuo Sha (National Centre for Meteorological Metrology, Atmospheric Observation Technology Centre, CMA, Beijing, )

Abstracts According to WMO, considered the need for regular calibration and maintenance of meteorological instruments to meet the increasing needs for high quality meteorological and hydrological data, the requirements of Members for standardization of meteorological instruments, the need for international instrument comparisons and evaluations, it was recommended to establish Regional Instrument Centers.

RICs are designated to carry out the following main functions: (a) To keep a set of meteorological standard instruments linked with recognized international or national standards and to log their performance and elements of comparison; (b) To assist Members of the Region in calibrating their national standard meteorological instruments or in comparing them with the standard instruments mentioned in (a) above and to keep the Members of the Region and the WMO Secretariat informed on the available standard instruments;

(c) To be prepared to certify the instruments’ conformity with the standards, with reference to WMO recommendations; (d) To organize instrument evaluations and comparisons, following standard methods; (e) To advise Members of the Region concerned on their enquiries regarding instrument performance and the availability of relevant guidance material; But up to now, there are no detail proposals for establishing a standard calibration laboratory. This paper will give three proposals to establish a standard meteorological metrology calibration laboratory for RICs.

1. General requirements for standard calibration instruments The achievable uncertainties can be obtained with good instrument systems that are properly operated. The most important requirements for meteorological instruments are: (a) Uncertainty (according to the stated requirement for the particular variable); (b) Reliability and stability; With regard to the above two requirements, it is important that an instrument should be able to maintain a known uncertainty over a long period.

In order to control effectively the standardization of meteorological instruments on a national and international scale, a system of national and regional standards has been adopted by WMO. In general, regional standards are designated by the Regional Associations and national standards by the individual Members. Unless otherwise specified, instruments designated as regional and national standards should be compared by means of travelling standards at least once every five years. Similarly, the instruments in operational use in a Service should be periodically compared directly or indirectly with the national standards.

The ability of individual sensors or observing systems to meet the stated requirements is changing constantly as instrumentation and observing technology advance. For some of the quantities, these uncertainties are achievable only with the highest quality equipment and procedures.

1.1 Temperature LABORATORY STANDARDS Primary standard thermometers will be held and maintained at national standards laboratories. A national meteorological or other accredited calibration laboratory will have, as a working standard, a high-grade platinum resistance thermometer, traceable to the national standard. The uncertainty of this thermometer may be checked periodically in a water triple-point cell. The triple-point of water is exactly defined and can be reproduced in a triple-point cell with an uncertainty of 1·10 -4 K.

Laboratory calibrations of thermometers should be carried out by national testing institutions or accredited calibration laboratories. For liquid-in-glass thermometers, a liquid bath should be employed, within which it should be possible to maintain the temperature at any desired values within the required range. The rate of temperature change within the liquid should not exceed the recommended limits and the calibration apparatus should be provided with a means of stirring the liquid. The reference thermometers and thermometers under test should be suspended independently of the container, fully immersed, and should not touch the sides. Sufficient measurements should be made to ensure that the corrections to be applied represent the performance of the thermometer under normal conditions with errors due to interpolation at any intermediate point not exceeding the non-systematic errors.

1.2 Air Pressure Analysed pressure fields are a fundamental requirement of the science of meteorology. It is imperative that these pressure fields be accurately defined as they form the basis for all subsequent predictions of the state of the atmosphere. Pressure measurements must be as accurate as technology will allow, within realistic financial constraints, and there must be uniformity in the measurement and calibration procedures across national boundaries. In view of the importance of accurate pressure observations, especially for aeronautical and synoptic purposes, and in view of the various possible errors to which mercury barometers are subject, all station barometers should be checked regularly by an inspector.

PRIMARY STANDARD BAROMETER One possible primary standard for atmospheric pressure consists of a precision dead weight tester that produces a calibrated pressure related to the precision weights used and the local gravity field. This type of barometer is relatively simple and does not suffer from the problem of excessive drift of mercury barometers in a polluted environment.

The primary standard barometer may well be a high-quality mercury barometer specially designed for that purpose. The primary standard mercury barometer must have a high vacuum, contain very pure mercury with a well-known density maintained at a constant temperature, and be located in an environment where pollution effects are prevented. The barometer also needs a calibrated measure (scale) and an optical read-out facility. These types of barometers measure absolute pressure with high absolute accuracy, while dead weight testers are gauge pressure measuring instruments.

1.3 Humidity Humidity measurements at the Earth’s surface are required for meteorological analysis and forecasting, for climate studies, and for many special applications in hydrology, agriculture, aeronautical services and environmental studies, in general. They are particularly important for their relevance to the changes of state of water in the atmosphere.

Principles involved in the calibration of hygrometers Precision in the calibration of humidity sensors entails special problems, to a great extent owing to the relatively small quantity of water vapor which can exist in an air sample at normal temperatures, but also due to the general difficulty of isolating and containing gases and, more particularly, vapor. An ordered hierarchy of international traceability in humidity standards is only presently emerging.

An absolute standard for humidity (i.e. a realization of the physical definition for the quantity of humidity) can be achieved by gravimetric hygrometry. The reference psychrometer (within its limited range) is also a form of primary standard, in that its performance is calculable. The calibration of secondary, reference, and working standards involves several steps.

1.4 Solar Radiation The various fluxes of radiation to and from the Earth’s surface are amongst the most important variables in the heat economy of the Earth as a whole and either at any individual place at the Earth’s surface or in the atmosphere. Radiation measurements are used for the following purposes: (a) Study of the transformation of energy within the Earth-atmosphere system and of its variation in time and space; (b) Analysis of the properties and distribution of the atmosphere with regard to its constituents, such as aerosols, water vapor, ozone, etc.;

(c) Study of the distribution and the variations of incoming, outgoing, and net radiation; (d) Satisfaction of the needs of biological, medical, agricultural, architectural and industrial activities with respect to radiation; (e) Verification of satellite radiation measurements and algorithms.

Such applications require a widely distributed regular series of records of solar and terrestrial surface radiation components, and the derivation of representative measures of the net radiation. In addition to the publication of serial values for individual observing stations, an essential object must be the production of comprehensive radiation climatologies, whereby the daily and seasonal variations of the various radiation constituents of the general thermal budget may be more precisely evaluated and their relationships with other meteorological elements better understood.

An RIC should satisfy the following conditions: (a) It should possess and maintain a standard group of radiometers, which consists, of either three standard radiometers of the Ångström, silver-disk or absolute radiometer type or of two absolute radiometers; (b) One of the standard radiometers should be compared at least once every five years against the World Standard Group;

(c) The standard radiometers should be intercompared at least once a year to check the stability of the individual instruments. If the ratio has changed by more than 0.2 per cent and if the erroneous instrument cannot be identified, then a recalibration at one of the World Radiation Centres has to be performed prior to further use as standard; (d) It should have the necessary facilities and laboratory equipment for checking and maintaining the accuracy of the auxiliary measuring equipment; (e) It should provide the necessary outdoor facilities for simultaneous comparison of national standard radiometers from the Region;

1.5 Wind Wind observations or measurements are required for weather monitoring and forecasting, for wind load climatology, for probability of wind damage and estimation of wind energy, and as part of the estimation of surface fluxes, e.g. evaporation, for air pollution dispersion and for agricultural applications. An accuracy for horizontal speed of 0.5 m s -1 below 5 m s -1 and better than 10 per cent above 5 m s -1 is usually sufficient. Wind direction should be measured with an accuracy of 5°.

A fully reliable calibration of cup, propeller, and vane anemometers is possible only in a wind tunnel; Wind-tunnel tests are useful for special projects or for type-testing new models.

2. Standard Configuration of Calibration Instruments The configuration proposals are based on the two factors. One is the economic conditions of the RIC Member country, the other is upon the technology level of the present time.

2.1 Basic Level of Standard Instruments The basic configuration proposal laboratory is designed to carry out the basic international comparison in RIC. Table 1 The Basic Configuration Proposal For RIC ’ s Laboratory Elements ClassTypeRangeUncertainty Temperaturesecondary Mercury-40°C to +50°C Platinum-50°C to +50°C0.025 °C HumiditysecondaryPsychrometer-50°C to +80°C Pressuresecondary Mercury hPa Quartz hPa p Solar Radiation secondaryPyranometer nm20W/m 2 WindsecondaryPitot Tube0-30m/s1m/s rainfallsecondaryBottle

2.2 Moderate Level of Standard Instruments The moderate configuration proposal laboratory is designed to carry out the basic international comparison in RIC and among the RICs. Table 2 The Moderate Configuration Proposal For RIC ’ s Laboratory Elements ClassTypeRangeUncertainty Temperature PrimaryPlatinum-80°C to +50°C0.025 °C Humidity Primary Chilled Mirror Dew Point 10%RH-99%RH1%RH Pressure PrimaryPiston hPa0.035hPa Solar Radiation Secondary Pyrheliome ter nm20W/m 2 WindSecondary Hot Wire Anemometer 0-30m/s1% or 0.5m/s rainfallSecondaryMass set25-500mm/h

2.3 The higher Level of Standard Instruments A higher configuration proposal of standard laboratory should consider more elements to be calibrated with much more higher uncertainty. Table 3 A Higher Configuration Proposal For RIC ’ s Laboratory Elements ClassTypeRangeUncertainty TemperaturePrimary Standard platinum resistance thermometer -80 – 156 o C0.002 °C HumidityPrimary Chilled mirror Dewpoint, Two-pressure humidity generator 1% RH to 99%RH (-50 to50°C) 1% of measured value PressurePrimary Digital piston manometer 500 hPa to1200hPa 6 Pa

Solar Radiation Primary Absolute radiometer Pyrgeometer 5.3% Pyrheliometer 1.5 % Pyranometer 3 % WindPrimary Pitot Tube and Differential Pressure Gauge, Hot wire Anemometer 0-75 m/s0.1 m/s RainfallSecondaryFlow bench mm/h 1% Ozone Photometric O 3 analyzer 2 ppb Spectrophotometer1% VisibilitysecondaryFD 12 10m-50 km 10%

Standard Solar Radiation Calibration Instrument 太阳辐射国家最高标准

TU Chamber and Humidity Calibration Instruments

Circle Type Wind Tunnel

Straight Type Wind Tunnel

Pressure Calibration Laboratory

Temperature and Humidity Calibration Laboratory

RI Calibration

THANK YOU!