“Magnetic Measurements for Particle Accelerators” International Master in Hadronteraphy, Pavia, 10 May 2013 Page.

Slides:



Advertisements
Similar presentations
Introduction to RF for Accelerators
Advertisements

It is very difficult to measure the small change in volume of the mercury. If the mercury had the shape of a sphere, the change in diameter would be very.
Lecture Notes Part 4 ET 483b Sequential Control and Data Acquisition
1 Sixth Lecture Types of Transducers and Their Applications Instrumentation and Product Testing.
BROOKHAVEN SCIENCE ASSOCIATES Abstract Vibrating Wire R&D for Magnet Alignment Animesh Jain, NSLS-II Project The alignment tolerance for a string of magnets.
Alignment of DB and MB quadrupoles Hélène MAINAUD DURAND 17/11/2011 With a lot of input from Sylvain GRIFFET.
SENSORS AND TRANSDUCERS
Classification of Instruments :
Enhancement of Single Stretched Wire Measurements of LHC Short Straight Sections Guy Deferne, Nikolay Smirnov, CERN Joe DiMarco, FNAL 14th International.
Physics 121 Practice Problem Solutions 11 Faraday’s Law of Induction
PCB Coil and stretched wire systems for high- precision quadrupole alignment J. DiMarco 16April2015 Abstract – In the measurement of magnetic fields of.
Coil Manufacture, Assembly and Magnetic Calibration Facility for Warm and Cold Magnetic Measurements of LHC Superconducting Magnets CERN AT-MTM 1 / 21.
April 12, 2006 J. Garcia Workshop on Test Facilities and measurement equipment needed for the LHC exploitation Resistive magnet measurements & coils, manufacture.
Topic 1 different attributes that characterize sensors ETEC 6405.
19 Nov 08,ILC08Cherrill Spencer Rotating Coil System Description 1 Short description of the SLAC rotating coil system used to measure the CIEMAT-made prototype.
1 / 19 M. Gateau CERN – Geneva – CH 14th International Magnetic Measurement Workshop September 2005, Geneva, Switzerland.
Rotating Coils - Giordana Severino – Rotating Coils PACMAN meeting Printed Circuit Coils – Future developments.
WP2 ESR 2.2 WP2 ESR2.2 Giordana Severino PACMAN WORKSHOP - CERN PCB technology for small diameter field sensing.
S. Russenschuck, CLIC-Workshop, WP2-Pacman, R&D projects on rotating coil probe and stretched wire techniques for CLIC / PACMAN Stephan Russenschuck.
ELECTRICAL CIRCUIT ET 201 Define and explain characteristics of sinusoidal wave, phase relationships and phase shifting.
Introduction to PACMAN Work Package 2 Magnetic Measurements
Power Lines The power transmission line is one of the major components of an electric power system. Its major function is to transport electric energy,
Iron Loss Calculation in a Claw-pole Structure
Vector Control of Induction Machines
General electric flux definition
LASER AND ADVANCES IN METROLOGY
1 LHC IR Quadrupole Alignment Experience at Fermilab T. Beale, J. DiMarco, J. Nogiec, P. Schlabach, C. Sylvester, J. Tompkins, G. Velev 28 September 2005.
Ultra-Compact Electrical Machines for Wind Energy DE-FOA : Demo Machine C. L. Goodzeit and M. J. Ball May 1, 2014 Part 1: Design and Construction.
Options for Final Focusing Quadrupoles Michele Modena CERN TE-MSC Many thanks for the contributions of: J. Garcia Perez, H. Gerwig, C. Lopez, C. Petrone,
Instrumentation for Magnetic Measurements” Review of Superconductors and Magnet Laboratories, May 2009 Page 1/7 Superconducting.
Capacitive transducer. We know that : C=kЄ° (A/d) Where : K=dielectric constant Є° =8.854 *10^-12 D=distance between the plates A=the area over lapping.
1 J.DiMarco 16Nov2010 LQS01b Magnetic Measurements Results ( preliminary ) J. DiMarco 16Nov2010.
“Magnetic measurement challenges for compact & low-consumption magnets” Workshop on Compact and Low Consumption Magnet Design, November.
1 Magnetic measurements proposal of the FAIR magnets Magnetic Measurements of Super-FRS dipoles: budgets 1 Budget for dipoles ( ) document FAIR-SFRS-magnetic_measurement_EVM.xls.
CLIC Beam Physics Working Group CLIC pre-alignment simulations Thomas Touzé BE/ABP-SU Update on the simulations of the CLIC pre-alignment.
Magnetic Metrology of SOLEIL Synchrotron S.R. Multipoles IMMW 14, A. Madur Magnetic Metrology of SOLEIL Synchrotron Storage Ring Multipoles A. Dael, P.
16 T Dipole Design Options: Input Parameters and Evaluation Criteria F. Toral - CIEMAT CIEMAT-VC, Sept. 4th, 2015.
BME 353 – BIOMEDICAL MEASUREMENTS AND INSTRUMENTATION MEASUREMENT PRINCIPLES.
CLIC Stabilisation Day’08 18 th March 2008 Thomas Zickler AT/MCS/MNC/tz 1 CLIC Quadrupoles Th. Zickler CERN.
Magnetic Field Stability Measurements Joe DiMarco 23Oct07.
PACMAN Error Inventory OUTLINE The PACMAN task The Inventory of contributors The Evaluation Method Critical Areas Outcome 08/10/2015 by Iordan Doytchinov.
Presentation 7/05/2015 Giordana Severino ESR2.2, WP2 CERN Supervisors Marco Buzio Academic supervisor Prof. Pasquale Arpaia.
ROBOTICS 01PEEQW Basilio Bona DAUIN – Politecnico di Torino.
Physics Requirements Sensitivity to Manufacturing Imperfections Strategy  where to map field  measure deviation from ideal model  fit to error tables.
Measurement of LHC Superconducting Dipole and Quadrupole Magnets in Ramp Rate Conditions G.Deferne, CERN Aknowledgements: M. Di Castro, S. Sanfilippo,
1 Magnetic measurements of the Super-FRS magnets 1 Overview: - Measurement systems for dipoles - requirements - Measurement systems review - Open points.
PACMAN : technical objectives Hélène Mainaud Durand.
CERN –GSI/CEA MM preparation meeting, Magnetic Measurements WP.
Midterm Review 28-29/05/2015 Progress on wire-based accelerating structure alignment Natalia Galindo Munoz RF-structure development meeting 13/04/2016.
Rotating Coil Measurement Errors* Animesh Jain Superconducting Magnet Division Brookhaven National Laboratory, Upton, NY 11973, USA 2 nd Workshop on Beam.
BRAINSTORMING ON LASER BASED SOLUTIONS FOR CLIC PRE-ALIGNMENT INTRODUCTION Hélène MAINAUD DURAND, BE/ABP/SU, 09/02/2010 Status of the study CLIC pre-alignment.
1 / 1 IMMW August 2007, Fermilab, Batavia, IL, USA CNAO R. Chritin CERN - Geneva Curved fluxmeter for static and dynamic characterization of pulsed.
Superconducting Cryogen Free Splittable Quadrupole for Linear Accelerators Progress Report V. Kashikhin for the FNAL Superconducting Magnet Team (presented.
Electric Pressure Transducer
MECH 373 Instrumentation and Measurements
MECH 373 Instrumentation and Measurements
Tutorial On Fiducialization Of Accelerator Magnets And Undulators
MECH 373 Instrumentation and Measurement
MECH 373 Instrumentation and Measurements
Advanced Photon Source Upgrade Project:
POWER TRANSMISSION with BELTS & CHAINS
Need for Alignment Position of off-momentum proton w.r.t. beam
Background With new accelerators delivering beams always smaller and more energetic, requirements for very precise beam alignment become more and more.
Outlines : Introduction . Construction . Control .
Brookhaven National Laboratory Upton, New York , USA
Yingshun Zhu Accelerator Center, Magnet Group
Prepared by Dr. Mohamed Ahmed Awad
FNAL Superconducting Quadrupole Test
MECH 373 Instrumentation and Measurements
Breakout Session SC3 – Undulator
Presentation transcript:

“Magnetic Measurements for Particle Accelerators” International Master in Hadronteraphy, Pavia, 10 May 2013 Page 1/65 Contents 1 – Rotating coils 2 – Stretched wire Magnetic Measurements for PACMAN Marco Buzio, TE/MSC/MM

“Magnetic Measurements for Particle Accelerators” International Master in Hadronteraphy, Pavia, 10 May 2013 Page 2/65 Main PACMAN WP 2.2 goal Development of a rotating coil system (single scanning coil and/or coil train) integrated on the PACMAN test stand in bldg. 169 and aimed at field quality (strength, harmonics, direction) measurements of CLIC quadrupoles. Magnetic measurement of the axis: if possible absolute, otherwise in relative (fixed-coil) mode with ultra-high bandwidth and resolution. This implies, within the 3-years span: a dedicated FAME system with an optimized PCB coil(s), FDI, FFMM script etc…. Metrological qualification, cross-checks with other instruments, with documented calibration and test procedures

“Magnetic Measurements for Particle Accelerators” International Master in Hadronteraphy, Pavia, 10 May 2013 Page 3/65 Workhorse of CERN instrumentation park: most accurate and cost-effective method Size, effective surface, number of turns, resistance, assemblies … must be adapted to the specific requirements of each magnet  no commercial solution, in-house R&D Main parameter: total area exposed to flux change Ac, which determines the peak induced voltage (limited by electronics, typically  5 or  10 V) Search coils Faraday’s law (total derivative) fixed-coil, time-varying field coil rotating, translating or deforming (wire) Fixed coil in a time-varying field Coil rotating at angular speed  in stationary, uniform field Coil translating at speed v in stationary field with gradient  B

“Magnetic Measurements for Particle Accelerators” International Master in Hadronteraphy, Pavia, 10 May 2013 Page 4/65 2D ideal rectangular rotating coil geometry integration constant: lost with fixed coil measurements, irrelevant (unphysical) for rotating coils integration bounds set by precise angular encoder  rotation speed fluctuations have negligible effects Rotating coils Rotating coils: yield simultaneously field strength, quality (harmonics), direction and center measured flux depends on both the field and coil geometry Discrete sampling of flux → Fourier components → field harmonics

“Magnetic Measurements for Particle Accelerators” International Master in Hadronteraphy, Pavia, 10 May 2013 Page 5/65 Rotating coil types Tangential coils: higher signal for the same area (on the boundary of the convergence circle) blind spot, difficult to align precisely Radial coils easier to build and to calibrate sensitive to all harmonics

“Magnetic Measurements for Particle Accelerators” International Master in Hadronteraphy, Pavia, 10 May 2013 Page 6/65 Coil sensitivity factors All coefficients can be calculated from coil length L, width w and radius R 0 All coefficients proportional to total coil area A c =N T Lw All coefficents increase like radius R 0 n-1 NB: calibration coefficients can be used at any field level – inherently linear sensor However: S/N at calibration gets better at high field NB: calibration coefficients can be used at any field level – inherently linear sensor However: S/N at calibration gets better at high field

“Magnetic measurements of the Linac4 diagnostic line dipole – first results” Page 7/7 Why is it difficult to measure small-aperture magnets ? general problem: static and dynamic deformations, vibrations, alignment, temperature drifts are more difficult to controlgeneral problem: static and dynamic deformations, vibrations, alignment, temperature drifts are more difficult to control Mechanical manufacturing tolerances are fixed=f(tooling) → coil sensitivity coefficient uncertainty  1/r (r=outer rotation radius)Mechanical manufacturing tolerances are fixed=f(tooling) → coil sensitivity coefficient uncertainty  1/r (r=outer rotation radius) the number of turns available for coils ( → signal level)  r 2the number of turns available for coils ( → signal level)  r 2 Signal level grow with linked flux variation →  r n-1 (e.g. radial coil), r n (stretched wire) (field/gradient strength, rotation/translation speed, length, etc. being equal)Signal level grow with linked flux variation →  r n-1 (e.g. radial coil), r n (stretched wire) (field/gradient strength, rotation/translation speed, length, etc. being equal) S/N ratio for quadrupole measurement may vary with r 3  r 4 …. BUT: small magnets are easier to flip around … e.g.: radial coil, n>1

“Magnetic Measurements for Particle Accelerators” International Master in Hadronteraphy, Pavia, 10 May 2013 Page 8/65 Coil bucking The accuracy of higher harmonics measured by individual coils may be affected by geometry errors Solution = coil bucking (or compensation): suitable linear combinations of coil signals cancel out the sensitivity to the main (and lower) harmonics  robustness to mechanical imperfections Example: in a perfect quadrupole, average gravity-induced sag  on a radial coil  flux error including mainly B 1 and B 3 components. A four-coil series/anti-series combination cancels out B 2 sensitivity  error-free harmonic measurement A B C D ideal geometry (no sag) sag-induced vertical eccentricity flux error  ( ) (zoomed)  ( ) B C D A  Arbitrary static coil imperfections cause no concern (effective sensitivities can be calibrated) Position- or time-dependent transversal imperfections  errors  harmonic n=main order Position- or time-dependent torsional imperfections  errors  harmonic n=main order -1 Coil design objective:  main =  main-1 =0, maximize |  n | with n>main order Additional benefit: common mode rejection, improved S/N (requires separate amplification)

“Magnetic Measurements for Particle Accelerators” International Master in Hadronteraphy, Pavia, 10 May 2013 Page 9/65 Effective coil width The flux corresponding to a given coil position can be obtained in various ways (flipping or rotating the coil, pulsing the field from zero) L can be considered as known from mechanical measurements General case: unless B(s) or w(s) are constant and can be taken out of the integral sign, the flux cannot be obtained from average width and average field: Define: effective width (N T gets lumped in for convenience) = average of width weighted with the field considerations made here for a dipole field hold true for other components as well

“Magnetic Measurements for Particle Accelerators” International Master in Hadronteraphy, Pavia, 10 May 2013 Page 10/65 Linac4 harmonic coil test bench Developed for small-aperture Linac4 permanent-magnet and fast-pulsed quads  19 mm, 200~400 mm long quadrupole-bucked coils (difficult measurement: S/N   aperture 3 !) Harmonic measurements in DC (continuously rotating coil) or fast-pulsed (stepwise rotating) mode. small size  flipping the magnet around allows elimination of many systematic errors in-situ calibration technique to improve accuracy despite geometrical coil imperfections

“Magnetic Measurements for Particle Accelerators” International Master in Hadronteraphy, Pavia, 10 May 2013 Page 11/65 Innovative miniature coils for CLIC quadrupoles CLIC QD0 prototype 64-layer PCB stack 3-coil dipole- and quadrupole- bucked array can be chained to measure long magnets at once

“Magnetic measurements of the Linac4 diagnostic line dipole – first results” Page 12/7 PCB coil-related R&D themes 1.general improvement of multi-layer PCB coils: track density (currently only ~1/3 of conventional coils), layer referencing and alignment (currently ~0.1 mm) 2.optimization of track layout to minimize sensitivity to production errors 3.improvement of the existing  8 mm rotating PCB coil shaft: mechanical stiffness of the assembly (materials, geometry, resins …), alignment and stability of ball bearings, scaling above and below  8 mm (e.g. is it possible  4 mm for CLIC,  20 mm for Linac magnets, or even more ?) 4.development (as suggested by Stephan) of a more compact Mini Rotating Unit MRU-II, i.e. about contacts instead of the current 76, better adapted to small coils, with less angular vibrations 5.PCB-based quench antennas (with compensation) 6.micro PCB connectors for multi-strand wire coils (as suggested by Olaf, to replace the existing micro-soldered connectors that only Lucette knows how to make) 7.large scale PCB fluxmeters: upper limits of current printing, pressing and assembly techniques + new possibilities offered by ELTOS; alternative architectures e.g. multiple mass-produced short boards + suitable inter-board connections 8.quality assurance of PCB fluxmeters: AC measurement of coil width, R/L measurement, calibration of magnetic equivalent coil area and coil distance inside reference magnets 9.micron-level precision coils for high order analog bucking (e.g. integrated circuit - scale fluxmeters) 10.Joe di Marco-style, polyvalent PCB sandwich coil shaft (flexible design, may be very practical for very large diameter rotating systems). Advanced materials (foams, honeycombs etc … for higher stiffness-to-weight ratio) 11.electronic acquisition systems: correction of side effects of high resistance load coils (input impedances, automatic resistance measurement and off-line correction, noise and offsets) 12.software tool to facilitate the design of new PCB coils, bypassing traditional CAD: from geometry specifications (e.g. straight/arc/straight or more realistic continuously varying curve)  layer design  Gerber format file 13.other techniques alternative to PCB: circuits printed on flexible rolls, inkjet circuit printers

“Magnetic measurements of the Linac4 diagnostic line dipole – first results” Page 13/7 Single Stretched Wire B stage Reference quadrupole A stage

“Magnetic measurements of the Linac4 diagnostic line dipole – first results” Page 14/7 Classical Single Stretched Wire DC operation: nominal field levelDC operation: nominal field level AC operation : enhanced sensitivity at very low field levels (e.g. 1 A in LHC cryomagnets), elimination of DC offset (stray fields, remanent …)AC operation : enhanced sensitivity at very low field levels (e.g. 1 A in LHC cryomagnets), elimination of DC offset (stray fields, remanent …) iterative axis finding  G x dy,  G y dx field direction (roll) field harmonics S 0, pitch, yaw

“Magnetic Measurements for Particle Accelerators” International Master in Hadronteraphy, Pavia, 10 May 2013 Page 15/ As tension measurement is affected by friction problems and gauge accuracy, the SSW system measures the fundamental frequency of the wire, which depends uponh its mechanical properties B stage A stage

“Magnetic measurements of the Linac4 diagnostic line dipole – first results” Page 16/7 Wire selection

“Magnetic Measurements for Particle Accelerators” International Master in Hadronteraphy, Pavia, 10 May 2013 Page 17/ IMMW1417 Integrated Strength (Gdl) (5) Magnetic properties of the wire Four different wires have been tested: 1.  0.1mm CuBe wire from California Fine Wire Co, USA 2.  0.1mm Mg wire from California Fine Wire Co, USA 3.  0.13mm CuBe wire from Goodfellow Co, UK 4.Carbon fiber strand from Toho Tenaz Europe gmbh, type HTA5241 (5). (  0.078mm silicon carbide, type SCS-9A from Speciality Materials Co, USA) (Note: type 5. could not be magnetically tested because of its high rigidity) Wire 0.76kA5kA11.85kAχ CuBe 0.1mm >0 Mg 0.1mm >0 CuBe 0.13mm <0 Multi filament Carbon strand --380<0 Slopes of strength for different types of wire in [T/s 2 ] CuBe Carbon fiber HTA5241 SCS-6 Silicon Carbide Different type of tested wire Note: if strength rises when tension increases, wire is diamagnetic If strength falls when tension increases, wire is paramagnetic

“Magnetic measurements of the Linac4 diagnostic line dipole – first results” Page 18/7 Single Stretched Wire