IET Code of Practice for in-service inspection and testing of electrical equipment 4 th Edition Amy Lyons – Product Manager Seaward Group.

Slides:



Advertisements
Similar presentations
Risk Assessment. Objectives By the end of this presentation you will know: What risk assessment is; Where the need for risk assessment comes from; and.
Advertisements

Nick Higginson Risk Assessment In The Workplace. Objectives By the end of this presentation you will know: What risk assessment is; Where the need for.
Managing the Health and Safety of Contractors
Engineering in business and the environment Lesson 6: Health and safety legislation.
An Introduction to Risk Assessment
OHS Induction Training
OH&S IN THE MUSIC INDUSTRY – WK 2, SEMESTER Why do we need it? Due to injuries within the workplace, and the increase of litigation and responsibilities.
Inspection & Test Overview suite412.
Risk Assessment.
Understanding the management of risks to health and safety on the premises of a retail business Unit 352.
AN INTRODUCTION TO THE FIRE SAFETY ORDER PHIL THOMPSON MIFireE FIRE SAFETY ADVISOR UNIVERSITY OF BRIGHTON.
Electrical Safety Training
By Danielle.  The provision and use of work equipment regulations was first introduced in 1992 but was replaced by a more update version in The.
Potential Electrical Problems Tennant replaces lighting fittings on their own Tennant adds lighting point Tennant adds socket outlet point Tennant removes.
Health and safety at work
Control of Substances Hazardous to Health Regulations 2002 (COSHH)
Fire Safety Jonathan Harrison Fire Protection Inspector West Yorkshire Fire & Rescue Authority.
SHE Code 4: Safety and Safe Use of Work Equipment
A Guide to Fire Alarm Service and Maintenance Requirements.
Testing and tagging. WorkSafe’s Goal Western Australian workplaces are free from death, injury and disease.
CDM 2015 How relevant is CDM 2015 to a Facilities Manager? A Discussion Paper Prepared by Henry Penn April 2015.
Safety and Loss Control
Health & Safety Risk Assessments.
W504 - Management of asbestos containing materials.
OH&S Management System
Risk Assessments By Shenika Dillon. What is a risk assessment and why are they carried out ? A risk assessment is a systematic method in which a employer.
Occupational health and safety
Health and Safety. The Health and Safety at Work Act 1974 An Act to make further provision for securing the health, safety and welfare of persons at work,
Hazard Identification
Introduction Definition Advantages for employees and employers
Work Health and Safety (National Uniform Legislation) Act and Regulations NT WorkSafe Anna McGill.
Imperial Ship Management AB “2.0”
Safety Induction to the Lift & Escalator Industry
What you will learn in this session 1.Sources of information about health & safety, including national legislation or guidance and local policies 2.Work.
A guide to… Maintenance Safety. Aim There is a legal requirement for regular and effective maintenance, inspection and testing of work equipment. This.
Unit 201: Health and safety in building services engineering
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Inspection Part II.
Merchant Shipping (Code of Safe Working Practices) Regulations Statutory Instrument 1998 No
ELECTRICITY AT WORK REGULATIONS THE REGULATIONS DICTATE THAT ALL PORTABLE EQUIPMENT MUST BE INSPECTED REGULARLY AND TESTED TO ENSURE THAT IT IS.
Ergonomics Regulatory Requirements Bawan Saravanabawan, Labour Program, HRSDC February 4, 2008.
Two of the most important pieces of the health and safety legislation affecting educational establishments across the UK are the Health and Safety at.
A European campaign on Risk Assessment Common errors in Risk Assessment.
Hansen – Managing Safely 1 Risk Assessment for Responsible Managers and Lead Assessors Mark Mallen Health and Safety Manager Fenlock Hansen Ltd.
Health and Safety Executive Health and Safety Executive CDM 2007 Training Package Competence & training Version: September 2007.
Electricity at Work Regulations Course Brian McRae June 2006.
PORTABLE & TRANSPORTABLE ELECTRICAL EQUIPMENT. Legal Requirement and References Abu Dhabi RSB Electrical Regulations - makes reference to the need to.
Managing Fire Safety In Common Parts of Flats and Mixed Use Buildings Simon Gibbins Merseyside Fire and Rescue Service.
A Health and safety law training programme for employers This programme has been set up to guide employers on some of the basic H&S legislation in the.
Nuneaton National Landlord Association Ian Halton 9 th March 2016.
Engineering Environment Awareness
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
The Repairing Standard ELECTRICAL INSTALLATIONS AND APPLIANCES.
Process Safety Management Soft Skills Programme Nexus Alliance Ltd.
Health & Safety for School Governors Presented by Phil West Health and Safety Advisor RBWM.
Every employer must ensure, as far as is reasonable practicable, the health, safety and welfare of all his employees More specifically, employers must.
SHE Requirements Clarification Meeting Date:17 November 2014 Compiled: Nompumelelo Kaule.
What you will learn in this session 1.Sources of information about health & safety, including national legislation or guidance and local policies 2.Work.
Mauritius Standards Bureau
OH&S Management System
Starter Activity What kind of tasks or situations is an employer legally required to perform a risk assessment for? Use of any work equipment. Management.
Cross Connection Survey Training
What Makes a Good Fire Risk Assessment?
Fire Risk Assessment in Community Halls and Licensed Premises
Testing and tagging.
OH&S Management System
The Electricity at Work Regulations 1989
OHS Staff Introduction Training
Click to buy Frequency of Inspection/Test Low risk: Offices, Shops, Hotels, Nursing Homes Type Class I Class II insp. test insp. test Stationary 24.
Definitions Hazard- the potential of a substance, activity or process to cause harm. They can take many forms such as chemicals, electricity or the use.
Presentation transcript:

IET Code of Practice for in-service inspection and testing of electrical equipment 4 th Edition Amy Lyons – Product Manager Seaward Group

Recent health & safety trends Government pressure to reduce the burden of over compliance HSE asked to review regulations / amend if necessary Recent health & safety trends

Löfstedt changes status quo

The Law As may be necessary to prevent danger, all systems shall be maintained, so as to prevent, so far as is reasonably practicable, such danger. Electricity at Work Regulations (1989)

Every employer shall make a suitable and sufficient assessment of the risks to the health and safety of his employees to which they are exposed whilst they are at work. Where the employer employs five or more employees, he shall record the significant findings of the assessment. The Law Management of Health and Safety at Work Regulations (1999)

Risk Based Approach

In-service inspection and testing reduces the risk of electric shock or fire in the workplace Maintenance regime should be proportionate to the risk Risk assessments are the responsibility of the duty holder Duty holder may enlist the services of a competent person Risk assessments should be reviewed regularly Risk based approach

‘A systematic process of evaluating the potential risks that may be involved in a projected activity or undertaking, considering what could go wrong and deciding on suitable control measures to prevent loss, damage or injury in the workplace. An assessment should include any controls required to reduce, minimize or eliminate any risk.’ Risk assessment

Performing a Risk Assessment 1. Potential hazards are recorded 2. Probability of an event is estimated by the assessor 3. Severity of harm is estimated by the assessor 4. Risk is calculated 5. Action is determined

What does this mean? Table 7.1 provides only guidance on initial frequencies of inspection and testing The duty holder: should determine the frequency of inspection and testing from risk assessment may take advice from person doing inspection and testing should determine the date for the next inspection and/or tests on a risk assessment basis

Changes to Table 7.1 4th Edition3rd Edition Environm ent Equipment Type Constructio n class Formal Visual Inspectio n and Test Formal Visual Inspectio n and Test IndustrialStationaryClass Inone24none12 IndustrialITClass Inone24none12 IndustrialMoveableClass I6121 IndustrialPortableClass I61216 IndustrialHand heldClass I61216 IndustrialFixedClass I1224

Changes to Table 7.1 4th Edition3rd Edition Environm ent Equipmen t Type Constructio n class Formal Visual Inspectio n and Test Formal Visual Inspectio n and Test IndustrialStationaryClass IInone24none12 IndustrialITClass IInone24none12 IndustrialMoveableClass II IndustrialPortableClass II61236 IndustrialHand heldClass II61236 IndustrialFixedClass II1248

Changes to Table 7.1 4th Edition3rd Edition Environ ment Equipment Type Constructio n class Formal Visual Inspectio n and Test Formal Visual Inspectio n and Test HotelsStationaryClass I HotelsITClass I HotelsMoveableClass I HotelsPortableClass I HotelsHand heldClass I HotelsFixedClass I2448

Changes to Table 7.1 4th Edition3rd Edition Environment Equipme nt Type Constructi on class Formal Visual Inspecti on and Test Formal Visual Inspecti on and Test Offices and shops StationaryClass I Offices and shops ITClass I Offices and shops MoveableClass I Offices and shops PortableClass I Offices and shops Hand heldClass I Offices and shops FixedClass I2448

Influencing factors The environment The users The equipment construction The type of equipment The frequency of use Type of installation methods Previous records

Example risk assessment

Generic risk assessment

Risk assessment reports

Test Operative Competency

Identification of equipment and appliance types to determine the test procedures Awareness of the risk assessment process for determining the frequency of inspection and testing Familiarity with the test instruments and their limitations and restrictions Able to fill in records and sign to take responsibility for the work. An understanding of how electrical, mechanical or thermal damage can occur to electrical equipment, flexes and plugs and connections Training Requirements

Industry qualifications for in-service inspection and testing of electrical equipment, alone, do not necessarily demonstrate competency. Must have an understanding of basic electrical and electronic principles, safe isolation procedures and safe systems of work, which, in some cases, may only be derived from previous knowledge, training and/or experience Training Requirements

Experience and technical knowledge to perform the inspection and testing without putting him/herself or others at risk Technical knowledge or experience may consist of adequate knowledge of electricity and adequate experience of electrical work An adequate understanding of the equipment to be worked on and practical experience of that system Experience Test operative should have:

Be aware of the hazards that may arise and the precautions that need to be taken Be able to recognize at all times whether it is safe for work to continue Be prepared to advise on suitability of equipment for the particular location and should be replaced with a more rugged item Be prepared to advise on a cost-effective maintenance regime Experience Test operative should:

Fixed Equipment

Fixed equipment. Equipment designed to be fastened to a support or otherwise secured in a specific location. Can movable or portable equipment, when connected to the fixed installation for security purposes Equipment types are numerous e.g. kettles, standard lamps, mini bar fridges, hair dryers, clock radios, coffee makers etc. Fixed Equipment

Fixed equipment or appliances are more difficult to inspect & test This does not mean that only visual inspections are required for these types of equipment They should receive a full combined inspection and test at relevant intervals Frequencies of these inspections and tests should be determined by a risk assessment Fixed equipment is now included in Table 7.1 Fixed Equipment

Testing can be undertaken during periodic inspection and testing of the fixed installation where the frequencies of any combined inspection and testing are similar to those for the fixed installation Additional formal inspections may be required for equipment that could be subjected to higher use or have a greater potential for being damaged, e.g. hand dryers, fixed hairdryers etc Fixed Equipment

Testing must be carried out by a competent person must be competent to carry out safe isolation procedures must be competent to carry out this more complex arrangement of work ensure safe systems of work are observed at all times ensure all inspections and tests are relevant to the equipment Competency Requirements

Testing fixed equipment

Earth continuity testing

Insulation resistance

Labelling

Current safety status e.g. passed or failed Date of inspection/test Date for retesting should not be marked on label Labelling

Hired Equipment

Requirements for Hire Companies is not within the scope Hired equipment is within the scope: –Short term hire (< 1 week) may not require testing but should be inspected before use –Extended hire (> 1 week) should be added to equipment register and included in inspection and test regime Hired equipment

Landlords

Landlords and property management companies in control of HMOs Houses in Multiple Occupancy (HMO). House in multiple occupation: - a property, rented to tenants, which fulfills one or all of the following: having multiple households, with shared toilet, bathroom or kitchen facilities, or utilizing a converted building which does not entirely incorporate self-contained flats (whether or not there is also a sharing, or lack, of amenities), or which is comprised entirely of converted self-contained flats and where the standard of conversion does not meet the minimum that is required, in England and Wales, by the 1991 Building Regulations or in Scotland the Building (Scotland) Regulations 2004 and more than one third of the flats are occupied under short term tenancies Who has responsibilities?

Surge protected devices

Surge protective devices (SPDs) help to prevent damage to equipment from voltage spikes or surges May give values of insulation resistance below normally accepted levels, by design. Reduce the test voltage to 250 V d.c. The inspector must exercise caution and record when this type of reduced test is carried out A protective conductor current test (Class I devices) and a touch current test (Class I and Class II devices) are recommended in addition to the insulation test Surge protected devices

Microwaves

The Code of Practice relates to electrical safety Microwave leakage testing is not an electrical safety test Visual inspection is already covered elsewhere in the document Section has been completely removed Microwave ovens

What do the changes mean for duty holders? Reduced cost of compliance? Need to take greater ownership Need for better understanding of EAWR Equipped to conduct range of risk assessments

What do the changes mean for contractors? Potentially reduced frequency of PAT testing Opportunities to provide additional services Raised standards of professionalism in the PAT industry Moving from cost-driven service to a value-added service

How can Seaward help? New instruments for all the requirements of the 4 th Edition Risk assessment training courses Image capture for fully traceable visual inspection and risk assessment Fire alarm and emergency lighting reporting & certification Comprehensive record management software for complete traceability

Thanks for your time Any questions?