Medical Laboratory Instrumentation 2010-2011 Third Year Dr Fadhl Alakwa www.Fadhl-alakwa.weebly.com UST-Yemen Biomedical Department.

Slides:



Advertisements
Similar presentations
Pulse Oximetry Karim Rafaat, MD.
Advertisements

Project ABLADE “Advanced Bladder cancer LAser Diagnostics and thErapy” University of Dundee, Nethergate, Dundee, DD1 4HN, Scotland, UK SPE “LAZMA”, Techpark.
Frequency modulation and circuits
Diodes and diode equation
Pulse Oximetry Dr.C.N.Chandra Sekhar M.D. Oxygenation Oxygen tension Oxygen content Oxygen saturation.
Sponsored by: Dept. of Veterans Affairs Group #5 Samuel Rodriguez Daniel Thompson Chadrick Williams Giselle Borrero.
Lecture 10. The time-dependent transport equation Spatial photon gradient Photons scattered to direction ŝ' Absorbed photons Photons scattered into direction.
© 2008 Masimo Corporation Includes a review on Carbon Monoxide Poisoning For Emergency Responders V.8 1 May 2011 Monitoring CO Poisoning with the Rad-57.
Pulse Detector Ramiro Duarte, Clayton Greenbaum Prof. Betty Lise Anderson.
Alex Bode Emmanuel Cordova Mikel Dualos Christa Hamilton Medical Instrumentation Spring 2011.
Pulse Oximetry Optional, AEMT.
South Taiwan University Institute of Mechanical Engineering How to Read SpO 2 and yoga breath’s Reference Prof. :Yi-Chu Hsu Name :Ruei-Cheng Liu Student.
14-May-15Najwa subuh- MSN in Pediatric1. 14-May-15Najwa subuh- MSN in Pediatric2 A pulse-oximeter is a device that measures the amount of saturated hemoglobin.
Raymond Chang Cornell University ECE 5030 FA2009.
Dr. Jeffrey Elliot Field HBSc, D.D.S., Diplomat of the National dental Board of Anesthesia, Fellow of The American Dental Society of Anesthesia.
Chapter 5 Part Three Blood Pressure and flow by Ibrhim AlMohimeed BMTS /3/2013.
Digital Tachometer ENGR 4803 Electromechanical Systems & Mechatronics.
1 Chapter 5 Sensors and Detectors A detector is typically the first stage of a communication system. Noise in this stage may have significant effects on.
Pulse Oximeter Measuring Oxygen Saturation Levels Final Presentation May 14, 2008 Tony Succar & Mustapha Okaddi.
1 Using PPG Morphology to Detect Blood Sequestration Stephen Linder Suzanne Wendelken Susan McGrath.
Improving Uncertainties of Non-Contact Thermometry Measurements Mark Finch Fluke Calibration.
 Distortion – the alteration of the original shape of a waveform.  Function of distortion analyzer: measuring the extent of distortion (the o/p differs.
BASIC ELECTRONICS.
Pulse oximetry is the noninvasive measurement of arterial blood oxygen saturation and heart rate. The Pulse Ox use a spectrophotometric probe. The pulse.
ONTARIO BASE HOSPITAL GROUP ADVANCED ASSESSMENT Principles Of Oximetry QUIT 2007 Ontario Base Hospital Group.
Jonathan Meyer Bogdan Dzyubak Matt Parlato Joe Helfenberger.
Lecture 3: Bridge Circuits
1 Radiometer Medical ApS, Åkandevej 21, DK-2700 Brønshøj, Tel: , Transcutaneous measuring principles – tc and saturation.
Optical Heart Monitor/Jump Drive Sponsor: Calit2 Mentor: Paul Blair Ph.D. Team: Matt Chandrangsu, Jeffrey Chi, Kari Nip ECE 191 – Group 6 Fall 2008.
Chapter 6 Photodetectors.
Topic 28: Direct Sensing 28.1 Sensing devices
Project: Pulse meter Idea: Use noninvasive infrared light to probe blood pressure and pulse rate in a finger tip. Uses: A variant of this device is used.
TA: Chris Reilly Group 5: Benjamin, Ramie, Zachary, Dinal.
© 2008 Masimo Corporation RAD-57 EMS Carry Case Lightweight: 13 oz. Small: 6.2” x 3.0” x 1.4” Portable: operates on 4 “AA” batteries Supplied with high-visibility,
Non-Invasive Oxygen Monitoring Pulse Oximetry & Conjunctival Oxygen Monitoring.
RITRIT Biomedical Engineering Department of Chemical and Biomedical Engineering Kate Gleason College of Engineering Rochester Institute of Technology.
Diode: Application Half-Wave Rectifier
EE 4BD4 Lecture 19 Pulse Oximeter 1. Utility Replace direct observation of blood oxygenation (pallor, cyanosis) or frequent arterial blood analysis Based.
Capacitive transducer. We know that : C=kЄ° (A/d) Where : K=dielectric constant Є° =8.854 *10^-12 D=distance between the plates A=the area over lapping.
South Taiwan University Institute of Mechanical Engineering
DESIGN OF ELECTRONIC SYSTEMS
Chapter 4 Bipolar Junction Transistors
Carbon Dioxide Monitoring
The Redesigning of a Pulse Oximeter
Optoelectronics.
Signal Analyzers. Introduction In the first 14 chapters we discussed measurement techniques in the time domain, that is, measurement of parameters that.
Project: Pulse meter Idea: Use noninvasive infrared light to probe blood pressure and pulse rate in a finger tip. Uses: A variant of this device is used.
Infrared IR Sensor Circuit Diagram and Working Principle.
A Cost Effective Centralized Single parameter Patient Monitoring System Abstract Lack of Medical monitoring equipment's in rural areas of underdeveloped.
Pulse Oximetry. What is a Pulse Oximeter? A device that provides a non-invasive (does not break the patient ’ s skin or body openings) method of allowing.
Monitoring in Anesthesia Dr.Arkan Jaafar, M.D. Anesthesiologist,Medical college of Mosul.
Signal conditioning Noisy. Key Functions of Signal Conditioning: Amplification Filter  Attenuation  Isolation  Linearization.
Objective To develop a durable, low-cost pulse oximeter probe to interface with the MedeCal, for use in developing countries. The MedeCal The MedeCal is.
PRESENTATION CSE 341 MICROPROCESSOR Presented By Nabid Kaisar
Pulse Oximetry Optional, AEMT.
BME 312 BIOMEDICAL INSTRUMENTATION II LECTURER: ALİ IŞIN
O2 and CO2 levels in blood.
Electronics & Communication Engineering
Special-Purpose Diodes
TEAM 2 – FALL 2006 PRESENTATION 1 LPM: Ahmad Omari.
Hemodialysis Lecture 3.
Pulse Detector Ramiro Duarte, Clayton Greenbaum Frank Paynter
Harmonic Distortion Analyzer, Wave Analyzer and Function Generator
Physiologic signals Lecture 5.
Photodetectors.
PIN DIODE.
OXYGEN RESERVE INDEX: UTILITY AS EARLY WARNING FOR DESATURATION IN MORBIDLY OBESE PATIENTS Sebastian Ayala, BS, Amrik Singh, MD, Richard Applegate II,
Optical Receivers 1. Photo Detectors
Recall-Lecture 5 DC Analysis Representation of diode into three models
Presentation transcript:

Medical Laboratory Instrumentation Third Year Dr Fadhl Alakwa UST-Yemen Biomedical Department

Spectrophotometer Is optical device that measure light absorption at various wavelengths for a given liquid sample.

Absorption Spectra Absorption Spectra Plot of Absorbance vs. wavelength called absorption spectrum.

Emission Spectra Emission Spectra Plot of emission intensity vs. wavelength called emission spectrum.

Spectrophotometer Example: Oxygen Saturation Using Pulse Oximetry

Spectrophotometer Example: Oxygen Saturation Using Pulse Oximetry Why Red was absorb more by Hb? Why Red was absorbed less by Hbo2? % Saturation = (HbO2/HbO2 + Hb) X 100

Photodetector senses only light of alternating intensity

Sao2 & Spo2 Pulse oximetry is a noninvasive monitoring technique used to estimate the measurement of arterial oxygen saturation (Sao2) of hemoglobin. Oxygen saturation is an indicator of the percentage of hemoglobin saturated with oxygen at the time of the measurement. Oxygen saturation values obtained from pulse oximetry (Spo2)

AC and DC

Pulse Oximetry ctures/med_elec/downloads.html#lecture ctures/med_elec/downloads.html#lecture

Pulse Oximetry: The story so far Oxygen is carried in the blood by haemoglobin which has two forms: Hb and HbO two forms: Hb and HbO2. These two forms have different absorptions at different wavelengths in the red to infra−red frequency band. By measuring the absorption of two different wavelengths and taking appropriate ratios it is possible, in theory, to evaluate the percentage of haemoglobin carrying oxygen.

Pulse Oximter Block Diagram

Pulse Oximetry instrumentation Looking at them one at a time (a) Shine light through the finger or ear lobe. (b) Control the pulsing of that light. (c) Receive the transmitted light. (d) Retain the received signal. (e) Control the amplitude of the transmitted light. (f) Filter, store and interpret the information.

Pulse Oximetry instrumentation Looking at them one at a time (a) Shine light through the finger or ear lobe. (b) Control the pulsing of that light. (c) Receive the transmitted light. (d) Retain the received signal. (e) Control the amplitude of the transmitted light. (f) Filter, store and interpret the information.

Illuminating Light Emitting Diodes (LEDs) are therefore, in principle, appropriate. However, standard LEDs are not sufficiently powerful. Special purpose LEDs have been designed Internal lensing to give a high intensity output. Pulsed LEDs so that peak peak power is increased.

Illuminating The LEDs need to be driven. Constant current through the LED (when on) ensures constant light output. How might this be achieved?

Illuminating

Pulse Oximetry instrumentation Looking at them one at a time (a) Shine light through the finger or ear lobe. (b) Control the pulsing of that light. (c) Receive the transmitted light. (d) Retain the received signal. (e) Control the amplitude of the transmitted light. (f) Filter, store and interpret the information.

Timing The LEDs should be pulsed for two reasons: Increased peak power for same average power. Careful timing of the ’on’ time for each LED allows a single photo−detector to be used for both LEDs.

Timing

Pulse Oximetry instrumentation Looking at them one at a time (a) Shine light through the finger or ear lobe. (b) Control the pulsing of that light. (c) Receive the transmitted light. (d) Retain the received signal. (e) Control the amplitude of the transmitted light. (f) Filter, store and interpret the information.

Detecting Photodiodes are the simplest solid−state optical detectors. When light falls on the junction p−n junction region an electron−hole pair is created. The hole and the electron are swept in opposite directions. The resulting light current is seen as a large increase in the reverse current. This current needs to be turned into a voltage.

Detecting

Pulse Oximetry instrumentation Looking at them one at a time (a) Shine light through the finger or ear lobe. (b) Control the pulsing of that light. (c) Receive the transmitted light. (d) Retain the received signal. (e) Control the amplitude of the transmitted light. (f) Filter, store and interpret the information.

Retaining A single photodetector is being used to provide two pieces of information. Therefore, it is important to know when it is giving information about absorption of the red and the NIR wavelengths respectively. Some form of sample−and−hold circuitry is therefore necessary.

Retaining

Pulse Oximetry instrumentation Looking at them one at a time (a) Shine light through the finger or ear lobe. (b) Control the pulsing of that light. (c) Receive the transmitted light. (d) Retain the received signal. (e) Control the amplitude of the transmitted light. (f) Filter, store and interpret the information.

Automatic Gain Control Automatic Gain Control (AGC) is when an attribute of a received signal is used to control the amplitude of the received signal. Commonly used in A.M. Radios.

Automatic Gain Control Three reasons why an AGC circuit is used in pulse oximetry It allows the frequency response of the photodiode to be ’corrected’. It keeps the a.c. signal (which varies between 0.1% and 2% of the total signal) within a pre−defined range. It allows the d.c. level of both the NIR and the red signals to be kept at the same level (say 2V).

Pulse Oximetry instrumentation Looking at them one at a time (a) Shine light through the finger or ear lobe. (b) Control the pulsing of that light. (c) Receive the transmitted light. (d) Retain the received signal. (e) Control the amplitude of the transmitted light. (f) Filter, store and interpret the information.

Programming Finally, a CPU of some description will be used to process the data. It will: Do any necessary noise final reduction (possibly using averaging). Calculate R. Infer the SaO2 using a look−up table.

35 The Ration R and Oxygen Saturation Attenuation not only by the arterial, venous and capillary blood but also by the skin (pigmentation causes absorption varies from person to person). Calibration uses look-up tables derived from studies on large numbers of healthy volunteers.

Pulse oximeter Test Index 2 Pulse Oximeter Simulator optical “finger” Please contact Dr Fadhl to use this material Simulators or performance analyzer? F Version FE Version

Verified Oximeter Makes The following makes of oximeters have been verified as working properly, both electronically and with their probes, and are pre-programmed into Index 2XL: BCI® (3101) Criticare® (504) Datascope® (Passport) Datex® (CardioCap, Ultima, Satellite Trans, AS/3, 251) HP® (Merlin) Nellcor® (N-100, 200) Nihon-Kohden® (Lifescope) Novametrix® Ohmeda® (3700) and Nova Respironics® Philips Medical Systems (PMS M1190) Nonin

Index 2 features Simulate saturated peripheral oxygen (SPO2) simulations with saturation levels between 35% and 100%. Variable heart rate settings from 30 beats per minute to 250

Challenge the pulse oximeter The Index 2XL preset feature combines SpO2 levels, heart rates, signal strength, motion, and pulse amplitude into seven preset conditions, which simulate a broad range of normal and abnormal patient conditions. The intent of this feature is to challenge the pulse oximeter under test with a variety of patient conditions to show operation over a complete range.

Preset simulations reproduce several patient conditions

Setting the Light Artifact You can set a light artifact with Index 2XL to test oximeters under different simulated ambient (surrounding) light conditions.

Transmission Level Control Up until the advent of Transmission Level Control (TLC), Index 2XL SpO2 simulations were based on a fixed finger-thickness uniquely defined for each pulse oximeter make. Since the implementation of TLC, pulse oximeters and probe performance can be more thoroughly tested over a range of simulated finger thicknesses. In simple terms, TLC is a variable attenuation of the RDC and IRDC terms, selectable over the entire range of counts for each make of the pulse oximeter.

Testing the Pulse Oximeter Limits Alarm tests for response time, recovery time, and pulse amplitude. O2, BPM, Amplitude If the O2 setting is outside the oximeter's alarm limit, the alarm will sound on the pulse oximeter being tested after a period of time. Press STOP immediately. This stops the timer, and Index 2XL display the “elapsed time to alarm” for the specified simulation level.

Simulating Pulse Amplitude The peak-to-peak amplitude of the blood pressure wave simulated by Index 2XL can be increased or decreased. Decreasing amplitude corresponds to a weakening pulse. You can decrease amplitude to find where the oximeter fails to find the pulse.

Simulating Asystole or No Pulse In a clinical setting, a no-pulse condition is life threatening. Most pulse oximeters sound alarms in response to this condition. Index 2XL can measure the response time of these alarms.

Electrical Probe Test BCI®  (3101) Criticare® (504) Datascope® (Passport) Nellcor® (N-100) Nihon-Kohden® (Lifescope) Novametrix® Ohmeda® (3700) Respironics® probe and electronics assembly testing either optically or electrically. Tests include: LED and photodiode electrical test Photodiode detector optical test pin-to-pin resistance

LED Testing Index 2XL applies 1.0 mA current AC signal source to the red and infrared LEDs. Index 2XL performs the electrical test separately on each diode to confirm they are functioning properly. The voltage drop across each lement is measured and displayed. Values can range from 0.0 to 2.0: 0.0 Volts = LED shorted 1.4 +/- Volts = LED OK

LED Testing The LEDS test should return a PHTO reading of approximately 0.6 volts if electrically good. Use

Photodiode Test This test looks at the probe as a functioning entity. Numbers close to zero support a faulty probe diagnosis. The red LED lights up and Index 2XL measures the resulting photodiode output. The red LED then goes out and again Index 2XL measures the output. The difference indicates the response to a 1 mA LED illuminating current. The same test measures the infrared LED. During the photodiode test, the finger probe being tested should not be attached to the Index 2XL finger.

Photodiode Test Both tests are repeated multiple times to average out ambient light, with the results displayed as a pair of numbers; one for red, and one for infrared, on a fixed scale giving an indication of photodiode response to each color. A higher number yields more response. Numbers can range from 0- 20,000 or more. It is a nominal value only.

Resistance Testing A resistance where none should exist indicates a faulty probe. Results must be interpreted in context of the probe schematic; some probes contain resistors, some do not.

Motivation  Oxygen –basis for human survival  Level of oxygen that a particular organ receives is very importance as it determines proper functioning of the body parts (organs)  For example: DM patients suffer from some form of lower extremity problem(neuropathy, vascular complication) are due to oxygen level changes(reduced blood flow) and decreased perfusion.

Importance of tissue oxygen level in any organ Tissue oxygenation and hemoglobin concentration are sensitive indicators of tissue status (Ferrari, et al., 1992 ) A sudden dip in the tissue oxygenation can be a direct indication of many harmful conditions like tissue degeneration, microbial infection etc. Non-invasive, real time, local measurement of tissue O 2 and HbT is not commercially available Deficiency of oxygen in tissue Tissue oxygenation - relative conc. of oxyhemoglobin & myoglobin, depends on the balance between oxygen delivery, as reflected by the product of blood flow and oxygen content and consumption.

Currently available Diagnostics methods Palpable pulse, Ankle brachial Index(ABI) by Doppler Blood flow or perfusion by Laser Doppler Imaging(LDI) Oxygen consumption and partial pressure by Transcutaneous oximetry. Altered blood flow status and arterial oxygen saturation by Photo Plethysmography(PPG) and pulse oximetry

Limitations Use of two wavelengths of light to derive fractional concentration of HBO2 is based on assumption that other forms of haemoglobin (metHb) and (COHb) have negligible contributions to total haemoglobin. In most situations, < 5% of haemoglobin is present as COHb and metHb. Increase in COHb or metHb leads to falsely high estimates of HbO2.

Accuracy of Pulse Oximetry Recording

Determine the Accuracy of Pulse Oximetry Compare and monitor the actual heart rate with the pulse rate value from the oximeter to determine accuracy of values. (The two numeric heart rate values should correlate closely. A difference in heart rate values may indicate excessive movement or a loss of pulsatile flow detection.

The accuracy of Spo2 The accuracy of Spo2 measurements requires consideration of many physiologic variables. Patient variables include the following 1- Hemoglobin level, 2- Arterial blood flow to vascular bed, 3- Temperature of digit or the area where the oximetry sensor is located, 4- Patient oxygenation ability, 5- Fraction of inspired oxygen (percentage of inspired oxygen), 6- Evidence of ventilation perfusion mismatch, 7- Amount of ambient light seen by the sensor, 8- Venous return at the sensor location.