Doña Ana Community College Addition Group B: Eric Navarro Jose Nunez Miguel Torres Angel Morales Luis Elias
Doña Ana Community College Each year the enrollment increases so in order to meet this demand they need to expand the facilities.
The objective of this project is to create an addition for the Doña Ana Community college in the border community. The Project
Job Site Location: 1700 East O'Hara Rd. (Anthony Gap)
Job Site The addition will take place here: 3 Classrooms Computer lab 3 Offices 2 Bathrooms 2 Storages
Design
Fabrication of tilt-up building walls Concrete Tilt-Up Panels
Tilt-up can be consider as a simple supported beam. Pw= 20 psf. H= 16 ft. H Total = 19 ft. Length will vary.
Metal Studs
Components
Stud Connections
Partitions
Openings
Insulation
Plasterboard We used: 720 ft metal tracks. 270 Pc Metal studs (10 ft) 180Pc Plasterboard (4’ x 10’) 3600 ft^2 Insulation
Tilt-Up Construction
Design of a Beam Required moment M u = k-ft The Beam in dimensions 12 x 16 with 4#9 bars The Nominal moment Capacity M n = k-ft The Strain of the Steel Deflection= 0.21in. Maximum Deflection =1.03in. Deflection = 5wL 4 384EI M u =W u L 2 8 ØR n =M u __ Øbd 2
Concrete Tilt Top Panel and Open Web Steel Joists Design Distributed load of w u =337.7 lb/ft Open Web Steel Joists, 22K6 w n = 347 lb/ft Deflection=0.58in. Maximum Deflection=1.03in. Concrete Tilt Top Panel
Description Pressure (psf) lb/ft Metal Deck, 18 gage 3 Insulation Roof Boards 1.5 Steel Joists, 31 ft 9.2 Mechanical Ducts 4 Skylight, Metal Frame, (3/8") 8 Gypsum Board, (5/8") 2.75 Water Proofing Membranes, 0.7 Single Ply Sheet Acoustical Fiber Tile 1 Suspended Channel System 2 Assumed Beam Weight 40 Total Roof Dead Load lb/ft 2 Live Load 20 lb/ft 2 Roof –Dead Loads Analysis
Column Analysis 12” 16” Dimensions 12 x 16 Area of Steel 8#9 bars Column Ties #3 13” Slenderness ratio Moment magnification= 1.07 Nominal Force on column : ΦP n =Φ.80[(.85)(f’c)(Ag-As)+(fy)(As)] KL < ( M 1 ) r M 2
SUSTAINABLE BUILT DESIGN Insulated windows Insulation boards (WALLS) Insulation boards (ROOF) Water storage tank
Insulated Windows Low-E windows Reduce energy Cost 25% to 50% Increase confort levels. Eliminate hot and cold spots Reduce noise up to 70%
Insulation Boards (WALLS) Energy Saver Insulates any part of the building Good thermal resistance Reduces heat conduction R19
Insulation Roof Boards Heat insulation, waterproof, fireproof Less smoke and harmful gas Chemical resistance Wide temperature limit R30
Water Storage Tank Advantages: Independent water system Gather water for recycling Irrigation purposes