Current Sensors. 2 Introduction Honeywell is proud to introduce its new line of current sensors and switches. - Current sensors and switches detect whether.

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

SITOP select Automation and Drives SITOP select Electronic Diagnosis Module Fault diagnosis – rapid and reliable.
MEGATRON. Privately owned shares company founded at The company is engaged in manufacturing Measu- rement, Monitoring and Control equipment. Megatron's.
QUALITY AND TECHNOLOGY
AC-SSC-1 Installation and operation manual
1/43 New Thyristor Unit Range TO INCREASE MARKET SHARE AND PROFIT A NEW, UNIQUE AND CONSISTENT RANGE.
Variable Frequency Drives VFD Basics
GS3055-I GSM Universal Wireless Alarm Communicator
PYRO-X De-Ice control devices Technical presentation 2013.
© Emotron AB Protection against damage and downtime Emotron M20 Shaft Power Monitor.
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
EUT 1040 Lecture 10: Programmable Logic Controllers.
Vibration Sensors for Cooling Towers Challenges Cooling towers offer the vibration analyst many challenges in sensor selection, mounting and environmental.
Smaller Simpler Better
Sales Training Outline 2006 Klaus Tum Product Manager NEW Circuit Breakers 35 Royal Road Flemington, NJ
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
PYROCON12 De-Ice controller User Operation Presentation 2013.
One solution, many application Integrated Electronic Solution PowerSupply Flex.
Advantys® STB High Density Discrete I/O Modules. AGP - English 2 Advantys® STB Advantys STB delivers customer value in distributed I/O Smart Built-in.
Ultima® X Series Gas Monitors
Make the most of your energy December 2008 PowerLogic Enercept Submetering ….when space is at a premium PowerLogic® Enercept Meter.
Chapter 7 SYSTEM PROTECTION
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
Vibration & Temperature Sensor. Contents ■ Why monitor vibration? ■ Monitor a wide range of machines ■ Vibration measurements ■ Set alarm levels ■ Mounting.
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 16 and above)
Overview of the 1.
BEX100 – Basic Electricity
MonoDrive & XT Constant Pressure Controller
The complete flow monitoring solution Measure – Display – Switch – Transmit.
TL70 The Choice is Yours: You choose how to order and build the TL70 with the flexibility to customize the tower light as needed and change positions in.
1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult.
COMPACT Variable Frequency Drives. Honeywell Proprietary Honeywell.com  Buildings Consume Massive Amounts of Energy Commercial Buildings consume massive.
Motor-driven pumps  Sigma/ 1  Sigma/ 2  Sigma/ 3.
Current Sensor Application Notes
Electrical Switches 1 st SEM Information Technology UNIVERSAL COLLEGE OF ENGINEERING & TECHNOLOGY SUBJECT: ELEMENTS OF ELECTRICAL ENGINEERING( )
: G10 Sensor – Market Launch Presentation Jim Gilbert DIV01 July 2014.
Water Detectors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design.
Pressure Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Vibration Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Esbe Rotary Motorized valves The ESBE Rotary Motorized valves (mixing valves and actuators) are used to control heating and cooling in buildings. We offer.
The complete flow monitoring solution Measure – Display – Switch – Transmit.
Series 28. Compatibility series 28 and many others… series 28 IFM OGP280 Banner QS18, DS18, MiniBeam Allen Bradley RightSight, MiniSight, VisiSight P&F.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
PRO-H Power Supplies. PRO-H Series  P owerful R eliable O ptimized - H azardous Areas  Complete family of Power Supplies 1-phase 3.8A up to 25A  Output.
Series 5. Compatibility series 5 and many others… series 5 Sick W100, W8, G6, W140, W160, W170 Omron E3Z P&F ML100 Allen Bradley VisiSight Keyence PZ-G.
Signal conditioning Noisy. Key Functions of Signal Conditioning: Amplification Filter  Attenuation  Isolation  Linearization.
ESX10-T Electronic Circuit Protectors with Hazardous Area approvals.
USER GUIDE TEMPERATURE CONTROLLER TR-2006 Hot runner temperature controller ShenZhen TanRex Electronic Co.ltd.
SOLID STATE RELAYS are used to produce reliable signal and to avoid expensive relay replacement.
INSTApower Compact Power Supplies. INSTA POWER INSTA POWER – Primary switch-mode power supplies The trend in the range of power supplies goes more and.
M20 Shaft Power Monitor PRODUCT TRAINING. Topics 1.What is an M20 Shaft Power Monitor 2.How does it measure Shaft HP 3.Benefits of Shaft Power measurement.
1-Port Ultra PoE to 4-Port 802.3af/at Gigabit PoE Extender
Electronic Control Systems Week 3 – Switches and Sensors
Training on Power Monitoring and Management Solution
System Network Structure
GROUND-FAULT GROUND-CHECK MONITOR
HVI HIPOT TEST SET Pft sERIES.
De-Ice control devices
Vibration Monitoring System M14
Module 1 – Power Supply AMC APS-PBC-60
Comparator Circuits AIM:
Copier Jam Detector Design Problem
Energy wise 2012 The new beginning Mike Dietz,
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
724 Temperature Calibrator
TR20 Series Wireless Training Slides
Presentation transcript:

Current Sensors

2 Introduction Honeywell is proud to introduce its new line of current sensors and switches. - Current sensors and switches detect whether current is flowing through electrical equipment, such as pumps and motors.  Detects when equipment is turned on or off.  Transmits the status to a building management system, DDC or PLC controller. - The wires are threaded through a hole in the current sensor which measures the current going through the wire. - Current sensors and transmitters can be used to detect a motor failure, belt loss or slippage, or a mechanical failure.

3 Key Features Higher operating range (250A) and very low trip points- down to 0.12 Amps Integral DIN rail mount Solid core and split core models Quick signal allows for service actions to be taken immediately to prevent damage and reduce downtime Current sensors are rated at 250 amps, allowing you to meet high-amp situations without needing transformer UL rated 5-year warranty

4 Key Features UL rated DIN Rail integrally mounted TRANSMITTER SWITCH Jumper Selectable Current Range Split core Solid core

5 Installation Easy to install and service Built-in DIN rail mounting flange simplifies installation Red and green LEDs – on adjustable switches. Red indicates over the trip point, green indicates below.

6 Current Switches CSS solid and CSP split core fixed and adjustable trip points - Monitor fans, pumps, motors, compressors, or other electrical equipment. - Change in current can trip the sensor to indicate equipment status or alarm condition. - Up to 250 Amps. - Do not need to be externally powered, since the power for the - switch is induced from the conductor being monitored. - Red LED – Indicates above the trip point on fixed models. - Red and Green Status LEDs – indicate above or below trip point on adjustable models.

7 Current Sensors (Transmitters) CTS solid and CTP split core 4-20mA, 0-5 and 0- 10Vdc - Solid core excellent choice for new installations - Split core ideal for retrofit or existing installations - Linear proportional output signal, can be monitored by your Building Management, DDC or PLC controller. - Available in either an Average or True RMS (for VFDs) output version. - Jumper selectable input ranges except for the 0 to 5 Amp input range. - Current sensors can be used in load trending (current monitoring) type applications. - Sensors are fast acting, reliable and extremely easy to install. - No additional DIN rail mounting clips are necessary, due to the unique design of the integral din rail mounting flange. - All of the CTS20 and CTP20 series current sensors are factory calibrated using a NIST Traceable standard - The CTS20 and CTP20 must be externally powered using a 12 to 35 Vdc power supply.

8 Current Switch Description Current Switches Part NumberDescriptionCore TypeNormally Open or Normally ClosedTrip PointOutput Switch Rating CSS-O-F5-001"Go/No Go" Current SwitchSolidN/O0.5A0.3A at 200Vac/Vdc CSS-O-F1-001"Go/No Go" Current SwitchSolidN/O0.1A0.3A at 200Vac/Vdc CSS-C-F5-001"Go/No Go" Current SwitchSolidN/C0.5A0.15A at 300Vac/Vdc CSS-C-F1-001"Go/No Go" Current SwitchSolidN/C0.1A0.15A at 300Vac/Vdc CSS-O-A Adjustable Current SwitchSolidN/O0.8A to 250A0.4A at 200Vac/Vdc CSS-O-A Adjustable Current SwitchSolidN/O0.35A to 250A0.4A at 200Vac/Vdc CSP-O-F15-001"Go/No Go" Current SwitchSplitN/O1.5A0.3A at 200Vac/Vdc CSP-O-F10-001"Go/No Go" Current SwitchSplitN/O1.0A0.3A at 200Vac/Vdc CSP-O-A Adjustable Current SwitchSplitN/O2.0A to 250A0.4A at 200Vac/Vdc CSP-O-A Adjustable Current SwitchSplitN/O1.7A to 250A0.4A at 200Vac/Vdc CSP-C-A Adjustable Current SwitchSplitN/C1.7A to 250A0.15A at 300Vac/Vdc

9 Current Transmitter Description Current Transmitters Part NumberCore TypeOutputCurrent RangeTypeTrue RMS or average CTS AVG-001Solid4-20mA0-100, 0-200, 0-250AadjustableAverage CTS VFD-001Solid4-20mA0-100, 0-200, 0-250AadjustableTrue RMS CTP AVG-001Split 4-20mA 0-100, 0-150, 0-200Aadjustable Average CTP VFD-001Split4-20mA0-10, 0-20, 0-50AadjustableTrue RMS CTS VDC-001Solid0-5Vdc0-10, 0-20, 0-50AadjustableAverage CTS VDC-001Solid0-10Vdc0-100, 0-200, 0-250AadjustableAverage

10 Feature summary FEATUREBENEFIT Very low operating current trip pointFewer wire loops required (if any), saving installation time LED status indication (red light current is above set point, green light current is below set point) Reduces set-up time and troubleshooting Integral DIN Rail mounting clipsNo accessory mounting clips needed 5-year warrantyProduct satisfaction Wide operating frequency rangeSmall sensor to operate in larger applications Accepts inputs up to 250 AmpsSmaller sensor to measure higher current, more cost effective solution Induced power supplyPower induced from monitored conductor, no separate power supply required Wide operating temperature rangeSwitches can be used in applications up to 150°F Split core designInstaller does not have to power down the unit or disconnect wires to install switches Large Hole Size (0.75 inches)Will fit up to 350 MCM cable

11 Literature Technical Literature Product Data Vdc Output Current Sensors Product Data 4-20mA Output Current Sensors Product Data Adjustable Switches Product Data Fixed Switches Installation Vdc Output Current Sensors Installation 4-20mA Output Current Sensors Installation Adjustable Switches Installation Fixed Switches Sales Literature Current Sensor Brochure Sensors Product Overview

12