GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate.

Slides:



Advertisements
Similar presentations
Introducing Florida Tech Laszlo Baksay Marcus Hohlmann High Energy Physics Group Dept. of Physics & Space Sciences.
Advertisements

Update on SBS Back Tracker UVa K. Gnanvo, N. Liyanage, V Nelyubin, K. Saenboonruang, Seth Saher Cross Talk issues with APV25 Electronics Uniformity.
Prototype of a Muon Tomography Station with GEM Detectors for Detection of Shielded Nuclear Contraband Michael Staib1 V. Bhopatkar1, W. Bittner1, K. Gnanvo1,2,
Nilanga Liyanage University of Virginia UVa GEM Team Dr. Kondo Gnanvo, Dr. Vladimir Nelyubin, Kiadtisak Saenboonruang, Chao Gu, Xinzhan Bai, Jie Liu, Seth.
Cosmic Ray Muon Detection Department of Physics and Space Sciences Florida Institute of Technology Georgia Karagiorgi Julie Slanker Advisor: Dr. M. Hohlmann.
Design and Construction of a First Prototype Muon Tomography System with GEM Detectors for the Detection of Nuclear Contraband M. Hohlmann 1, K. Gnanvo.
We have no control on the slow and sparse incoming muon flux Visualizing sufficient scattered POCA points in target volume satisfactorily takes long time.
A First Application for the Scalable Readout System: Muon Tomography with GEM Detectors RD51 Collaboration Meeting WG5 - May 25, 2010 Marcus Hohlmann with.
Gain measurements of Triple Gas Electron Multiplier (GEM) detector with zigzag readout strips V. BHOPATKAR, E. ESPOSITO, E. HANSEN, J. TWIGGER M. HOHLMANN.
2012 IEEE Nuclear Science Symposium Anaheim, California S. Colafranceschi (CERN) and M. Hohlmann (Florida Institute of Technology) (for the CMS GEM Collaboration)
Experience with medium-size SRS for muon tomography Michael Staib Florida Institute of Technology.
Energy Conservation Lab. Purpose To determine which type of light bulb is the most energy efficient.
Precision Drift Chambers for the ATLAS Muon Spectrometer Susanne Mohrdieck Max-Planck-Institut f. Physik, Munich for the ATLAS Muon Collaboration Abstracts:
Lead Tungsten Uranium Tin Iron Tantalum Abstract Muon tomography aims at detecting and 3D-imaging well-shielded high-Z material, e.g. nuclear contraband.
Readout Board Design for Gas Electron Multiplier Detectors for Use in a Proposed Upgrade of the CMS Hadron Calorimeter Elizabeth Starling Marcus Hohlmann.
Online Monitoring and Analysis for Muon Tomography Readout System M. Phipps, M. Staib, C. Zelenka, M. Hohlmann Florida Institute of Technology Department.
Prototypes For Particle Detectors Employing Gas Electron Multiplier
Performance Expectations for a Tomography System Using Cosmic Ray Muons and Micro Pattern Gas Detectors for the Detection of Nuclear Contraband Kondo Gnanvo,
Large-area Gas Electron Multiplier Detectors for a Muon Tomography Station and its Application for Shielded Nuclear Contraband Detection K. Gnanvo 1, L.
Strip No Detection and Imaging of High-Z Materials with a Muon Tomography Station using GEM Detectors K. Gnanvo 1, W. Bittner 1, B. Benson 1, F. Costa.
Monte Carlo simulations of a first prototype micropattern gas detector system used for muon tomography J. B. Locke, K. Gnanvo, M. Hohlmann Department of.
Simulation of an MPGD application for Homeland Security Muon Tomography for detection of Nuclear contraband Kondo Gnanvo, M. Hohlmann, P. Ford, J. Helsby,
Construction and first commissioning of the self-stretched gas electron multiplier (GEM) detector J. Twigger, V. Bhopatkar, J. Wortman, M. Hohlmann 77th.
75 th Annual Meeting March 2011 Imaging with, spatial resolution of, and plans for upgrading a minimal prototype muon tomography station J. LOCKE, W. BITTNER,
Statement of Interest in CMS MPGD High-  Muon Upgrade Florida Tech CMS Muon Group Marcus Hohlmann Florida Institute of Technology, Melbourne, FL, USA.
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger,
J.Slanker, D. Dickey, K. Dehmelt, M. Hohlmann, L. Caraway
GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito, Erik Maki Faculty Advisor: Dr. Marcus Hohlmann, Dept. of Physics and Space.
News on GEM Readout with the SRS, DATE & AMORE
Update on the Triple GEM Detectors for Muon Tomography K. Gnanvo, M. Hohlmann, L. Grasso, A. Quintero Florida Institute of Technology, Melbourne, FL.
GEM Detector R&D at Florida Tech – “Get to know each other” –
2009 Florida Academy of Sciences at Saint Leo University, Saint Leo, Florida Performance comparison of the triple gas electron multiplier (GEM) and the.
M. Staib, M. Abercrombie, B. Benson, K. Gnanvo, M. Hohlmann Department of Physics and Space Sciences Florida Institute of Technology.
Live Event Display and Monitoring Program for a Muon Tomography Station Michael Phipps, Judson Locke, Michael Staib; Adviser: Dr. Marcus Hohlmann Department.
 The zigzag readout board is divided into eight η-sectors; each sector has a length of ~12 cm and comprises 128 zigzag strips; zigzag strips run in radial.
Large-Area GEM Detector Development at CMS, RD51, and Fl. Tech – A brief overview – Marcus Hohlmann Florida Institute of Technology, Melbourne, FL PHENIX.
Cost Reduction for Gas Electron Multiplier Detector Readout Boards Using Zigzag Strips Elizabeth Starling Marcus Hohlmann Kimberley Walton, Aiwu Zhang.
Abstract Beam Test of a Large-area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger,
Beam Test of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger, A.
Construction and beam test analysis of GE1/1 prototype III gaseous electron multiplier (GEM) detector V. BHOPATKAR, E. HANSEN, M. HOHLMANN, M. PHIPPS,
Construction and Characterization of a GEM G.Bencivenni, LNF-INFN The lesson is divided in two main parts: 1 - construction of a GEM detector (Marco Pistilli)
SpaceGEM A Novel Electric Ion Thruster for Space Vehicles Section 1: In-space systems Dr. S. Colafranceschi & Dr. M. Hohlmann Dept. of Physics & Space.
Abstract Muon tomography for homeland security aims at detecting well-shielded nuclear contraband in cargo and imaging it in 3D. The technique exploits.
Detecting shielded nuclear contraband using muon tomography Judson Locke, William Bittner, Leonard Grasso, Dr. Kondo Gnanvo; Adviser: Dr. Marcus Hohlmann.
Abstract Muon tomography for homeland security aims at detecting well- shielded nuclear contraband in cargo and imaging it in 3D. The technique exploits.
Gas Electron Multiplier
Eija Tuominen, coordinatorHIP/UH Detector Laboratory, October 2010 DETECTOR DEVELOPMENT at HELSINKI DETECTOR LABORATORY Detector Laboratory is a joint.
T2 GEM Production in Helsinki Kari Kurvinen TOTEM T2 EDR meeting Radiation Detector Laboratory of Helsinki Institute of Physics (HIP) and Department.
Solar Oven Investigation How different linings affect oven performance.
A High Eta Forward Muon Trigger & Tracking detector for CMS A High Eta Forward Muon Trigger & Tracking detector for CMS Archana Sharma For CMS High Eta.
J. Helsby, P. Ford, R. Hoch, K. Gnanvo, R. Pena, M. Hohlmann, D. Mitra
(On Behalf of CMS Muon Group)
Dept. of Physics and Space Sciences, Florida Institute of Technology
A. Zhang, S. Colafranceschi, M. Hohlmann
Matthew Bomberger1, Francisco Izquierdo1, Aiwu Zhang2
Large CMS GEM with APV & SRS electronics
Nathan Mertins, Michael Staib, William Bittner
Development of GEM Detectors for Muon Tomography
Development of Gas Electron Multiplier Detectors for Muon Tomography
EIC Tracking Meeting, March 26, 2012
J. Twigger, V. Bhopatkar, E. Hansen, M. Hohlmann, J.B. Locke, M. Staib
Event Monitor and Display for Muon Tomography Station
A. Zhang, S. Colafranceschi, M. Hohlmann
(On Behalf of CMS Muon Group)
Alfred Menendez, Michael Abercrombie, Amilkar Quintero, Kondo Gnanvo
Production of a 3D-Printed THGEM Board
Background Concept Results Conclusions
Micro Resistive Well Detector for Large Area Tracking
Alejandro Busto, Devkumar Roy, Liam Shaw, Joseph Weatherwax
Construction and Test of a Modular GEM for EIC
Presentation transcript:

GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate Research Florida Institute of Technology, HEP Lab A FAS Annual Conference, March 2012

Overview Purpose / Background Previous work Improvements to previous work Results Conclusions Future plans

Purpose Design a cost-effective, readily- implemented method of stretching GEM (gas electron multiplier) foils, improving upon previous designs. 100cm x 50cm GEM foils stretched with this method will be used to upgrade the muon tomography station of Florida Institute of Technology’s High Energy Physics Lab A.

Why Stretch GEM Foils? GEM foils are a crucial component of detectors such as the triple GEM detector on the left. In order to be useable, they must be uniform. This uniformity is obtained through stretching, usually in a clean room oven.

Muon Tomography Station (MTS) Two 30cm x 30cm GEM detectors were built for Florida Tech’s muon tomography station using the following method. Below: Imaging area seen with two blocks of high-Z material. [GEM Detectors]

Previous Work Designed to stretch 100cm x 50cm GEM foils – scaled-up from 30cm x 30cm design – as cost-efficiently as possible using locally-sourced materials. Aluminum frame supports eight/sixteen 250W infrared heat lamps. Used to stretch foils at 45°C - 50°C.

Why 35°C? The above GEM foil was stretched at 50°C. Note the ridging of the spacer ribs! Lower temperatures minimize / eliminate this! (CERN stretches at 37°C).

Current Design Credit: Elizabeth Esposito, ”-diameter aluminum rods support the frame – allows for greater versatility and mobility. Several stations can easily be set up on the same optical table. Sixteen 125W heat lamps were used in place of the previous 250W bulbs. Used to stretch foils at 35°C.

Results Number of temperature measurements per bin Mean: 35.12°C RMS:

Top: Current results, 125 W bulbs RMS: Bottom: Previous results, 250 W bulbs RMS: Number of temperature measurements per bin

Results Long-Term Temperature Variation Stable plateau reached at ~3 hours Optical Table [Location key]

Top: Unstretched 100 x 50cm …….GEM foil at ~25°C. Bottom: Stretched 100 x 50 cm GEM foil at 35°C. Note the reflection of the light bulbs in the foil!

Conclusions 125 W light bulbs provided a very uniform temperature of ~35°C. Temperature variations were minimal and did not affect the operation of the array. Current results: RMS: compared w/ previous results: RMS: Foils stretched using this method appeared to be uniformly stretched.

Future Plans Improve the methods of temperature control. Build multiple arrays for more efficient detector construction. Use the array to stretch 100cm x 50cm GEM foils for use in upgrading Florida Institute of Technology’s muon tomography station.

Acknowledgements Research advisor: Dr. Marcus Hohlmann Previous work: Michael Staib Bryant Benson Kondo Gnanvo