Maurizio Conti, Siemens Molecular Imaging, Knoxville, Tennessee, USA

Slides:



Advertisements
Similar presentations
What are PET basics?.
Advertisements

Presented by Scott Lichtor Introduction to Tomography.
1 Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration Joonki Noh, Jeffrey A. Fessler EECS Department, The University.
Direct Fourier Reconstruction
Mark Mirotznik, Ph.D. Associate Professor The University of Delaware
Image reconstruction and analysis for X-ray computed microtomography Lucia Mancini 1, Francesco Montanari 2, Diego Dreossi 3 1 Elettra - Trieste 2 A.R.P.A.
Image Reconstruction T , Biomedical Image Analysis Seminar Presentation Seppo Mattila & Mika Pollari.
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
Completion of a Truncated Attenuation Image from the Attenuated PET Emission Data Johan Nuyts, Christian Michel, Matthias Fenchel, Girish Bal, Charles.
Patch-based Image Deconvolution via Joint Modeling of Sparse Priors Chao Jia and Brian L. Evans The University of Texas at Austin 12 Sep
IMAGE, RADON, AND FOURIER SPACE
Statistical image reconstruction
Department of Computer Science
BMME 560 & BME 590I Medical Imaging: X-ray, CT, and Nuclear Methods Tomography Part 2.
BMME 560 & BME 590I Medical Imaging: X-ray, CT, and Nuclear Methods Tomography Part 3.
BMME 560 & BME 590I Medical Imaging: X-ray, CT, and Nuclear Methods Tomography Part 4.
Imaging PET Course Layout Class + ContentDateClass Physical Principles of PET I Physical principles of MRI II Imaging applications III.
Project Overview Reconstruction in Diffracted Ultrasound Tomography Tali Meiri & Tali Saul Supervised by: Dr. Michael Zibulevsky Dr. Haim Azhari Alexander.
Algebraic and Statistic Reconstruction Algorithms Liran Levy Advanced Topics in Sampling (049029), Winter 2008/9.
RELAXED ORDERED-SUBSETS ALGORITHM FOR IMAGE RESTORATION OF CONFOCAL MICROSCOPY Saowapak Sotthivirat and Jeffrey A. Fessler University of Michigan, Ann.
Media Cybernetics Deconvolution Approaches and Challenges Jonathan Girroir
tomos = slice, graphein = to write
Back Projection Reconstruction for CT, MRI and Nuclear Medicine
Introduction to Longitudinal Phase Space Tomography Duncan Scott.
Application of Digital Signal Processing in Computed tomography (CT)
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
Medical Image Analysis Dr. Mohammad Dawood Department of Computer Science University of Münster Germany.
Medical Imaging Dr. Mohammad Dawood Department of Computer Science University of Münster Germany.
Supplementary Material Emission Computed Tomography
Design and simulation of micro-SPECT: A small animal imaging system Freek Beekman and Brendan Vastenhouw Section tomographic reconstruction and instrumentation.
These slides based almost entirely on a set provided by Prof. Eric Miller Imaging from Projections Eric Miller With minor modifications by Dana Brooks.
Innovation is in our genes. 1 Siemens Medical Solutions Molecular Imaging What are SPECT basics?
Seeram Chapter 7: Image Reconstruction
Filtered Backprojection. Radon Transformation Radon transform in 2-D. Named after the Austrian mathematician Johann Radon RT is the integral transform.
Medical Image Analysis Image Reconstruction Figures come from the textbook: Medical Image Analysis, by Atam P. Dhawan, IEEE Press, 2003.
Flow Chart of FBP.. BME 525 HW 1: Programming assignment The Filtered Back-projection Image reconstruction using Shepp-Logan filter You can use any programming.
Image Reconstruction from Projections Antti Tuomas Jalava Jaime Garrido Ceca.
Bayesian Estimation for Angle Recovery: Event Classification and Reconstruction in Positron Emission Tomography A.M.K. Foudray, C.S. Levin Department.
GPU-based Image Processing Methods in Higher Dimensions and their Application to Tomography Reconstruction Szirmay-Kalos, László Budapest Uni of Tech Sapporo,
Single Photon Emission Computed Tomography
Professor Brian F Hutton Institute of Nuclear Medicine University College London Emission Tomography Principles and Reconstruction.
Compartment model based analytical PET simulator for PVELab L. Balkay, I. Valastyán, M. Emri, L. Trón UDMHSC, PET Center, Debrecen, Hungary.
Ultrasound, Positron Emission Tomography, and Single Photon Emission Tomography Allen T. Newton, Ph.D. PAVE 2014.
Computed Tomography Diego Dreossi Silvia Pani University of Trieste and INFN, Trieste section.
IMAGE RECONSTRUCTION. ALGORITHM-A SET OF RULES OR DIRECTIONS FOR GETTING SPECIFIC OUTPUT FROM SPECIFIC INPUT.
Li HAN and Neal H. Clinthorne University of Michigan, Ann Arbor, MI, USA Performance comparison and system modeling of a Compton medical imaging system.
Nuclear Medicine: Tomographic Imaging – SPECT, SPECT-CT and PET-CT Katrina Cockburn Nuclear Medicine Physicist.
1 Reconstruction Technique. 2 Parallel Projection.
Single-Slice Rebinning Method for Helical Cone-Beam CT
Introduction In positron emission tomography (PET), each line of response (LOR) has a different sensitivity due to the scanner's geometry and detector.
Ultrasound Computed Tomography 何祚明 陳彥甫 2002/06/12.
Impact of Axial Compression for the mMR Simultaneous PET-MR Scanner Martin A Belzunce, Jim O’Doherty and Andrew J Reader King's College London, Division.
Introduction In Positron Emission Tomography (PET), each line of response (LOR) has a different sensitivity due to the scanner's geometry and the detector's.
Statistical Methods for Image Reconstruction
Ultrasound Computed Tomography
CSCI 631 – Foundations of Computer Vision March 15, 2016 Ashwini Imran Image Stitching.
Chapter-4 Single-Photon emission computed tomography (SPECT)
Theory of Reconstruction Schematic Representation o f the Scanning Geometry of a CT System What are inside the gantry?
PET Imaging Positron Emission Tomography
Nuclear Medicine Physics
Chapter-4 Single-Photon emission computed tomography (SPECT)
P.E.T. Positron Emission Tomography
Stencil-based Discrete Gradient Transform Using
Degradation/Restoration Model
Single Photon Emission Tomography
Tianfang Li Quantitative Reconstruction for Brain SPECT with Fan-Beam Collimators Nov. 24th, 2003 SPECT system: * Non-uniform attenuation Detector.
Prepared by Nuhu Abdulhaqq Isa
Volume 11, Issue 2, Pages (April 2016)
Filtering Removing components from an image is know as “image filtering”. If we remove the high frequency components, we tend to remove the noise. This.
Computed Tomography.
Presentation transcript:

Maurizio Conti, Siemens Molecular Imaging, Knoxville, Tennessee, USA Introduction to PET reconstruction Maurizio Conti, Siemens Molecular Imaging, Knoxville, Tennessee, USA

Summary Emission data corrections Analytical methods (FBP) Iterative methods (MLEM, OSEM) Point Spread Function (PSF) Time-of-Flight (TOF)

Emission Sinogram 0° 45° 90°

Need to correct the data B Attenuation A B C D Normalization D Scatter A B C D

Emission Sinogram m-map Normalization Scatter simulation Scatter correction Attenuation correction

E X = N N x E recon X = A x (N x E) A recon = _ A x (NxE) - S S recon

Reconstruction Analytical: “exact” solution to a system of equations. For example: Filtered Back Projection, in image or Fourier space. Iteratives: iterative process in which an intermediate image converges toward the “true” image. For example: - Maximum Likelihood Expectation Maximization (MLEM), - Ordered Subsets Expectation Maximization (OSEM), - Row Action Maximum Likelihood Algorithm (RAMLA) .

Reconstruction from projections Radon (1917): xr p(xr, ) p(xr, ) = dyr f(x,y) = R {f(x,y)}  f(x,y) = R -1{p(xr, )} = d b(xr, )  Backprojection operator

Back projection in image space

Filtered back projection in image space Apply a filter function to the projections before back projection

Filtered back projection in Fourier space Central slice (or central section) theorem

Filtered back projection in Fourier space Fourier transform (1D) of a projection filter the projection in frequency space repeat for all angles j Interpolate on the rectangular grid Inverse Fourier transform (2D)

Filtered back projection in Fourier space : filters Ramp filter Additional filter The ramp filter is used to eliminate the star artifact and improve spatial resolution, but it also amplifies the noise (high frequencies). To compensate for these effects, low-pass smoothing filters are applied to cutoff frequencies higher than a certain limit.

Filtered back projection in Fourier space

Iterative methods The Maximum Likelihood Expectation Maximization (MLEM) is based on the maximization of the logarithm of a Poisson-likelihood probability function. It updates the image during each iteration by using a multiplicative factor assessed as the ratio between the original acquired projections and the newly estimated ones. Advantages of this iterative method are low noise, good spatial resolution, and the fact that all reconstructed values will be positive because a nonnegativity condition is imposed on the original data. The main disadvantage is the large number of iterations required to converge to an optimal solution. To overcome the problem of slow convergence rate, the ordered-subsets expectation maximization (OSEM) algorithm was proposed in 1994. The OSEM is a modified version of MLEM with the main difference being that projections are grouped into subsets of angles. Within each iteration the image is updated as many times as the number of subsets, proportionally accelerating convergence.

MLEM and OSEM Yj li MLEM Which l maximizes the L(l) ? OSEM

MLEM and OSEM, references MLEM: L.A.Shepp, Y.Vardi, Maximum Likelihood reconstruction for emission tomography (maximum likelihood expectation maximization) IEEE Trans.Med. Imaging, vol. 1, no.2, 1982, 113-122. MLEM: K.Lange, R.Carson, EM reconstruction algorithms for emission and transmission tomography, Journal of Computer Assisted Tomography, vol.8, no.2, 1984, 306-316. OSEM: H.Malcolm and R.Larkin, Accelerated Image reconstruction using Ordered Subsets of projection data (ordered subsets expectation maximization) IEEE Trans. Nucl. Sci., vol. 13, no.8, 1994, 601-609.

MLEM, with physics corrections BackProjector ForwardProjector scatter correction normalization correction randoms correction attenuation correction

2D or 3D reconstruction 2D reconstruction is faster Rebinning techniques move 3D data into 2D data New fast algorithms and computer make rebinning less necessary!

Recent reconstruction improvements Iterative algorithm (OSEM) : rebin 3D2D + OSEM2D OSEM3D OSEM3D + Point Spread Function (PSF) OSEM3D + Point Spread Function + Time-of-Flight (TOF) OSEM-3D + PSF + TOF OSEM-3D + PSF OSEM-3D rebin 3D2D + OSEM-2D

Point Spread Function (PSF) When a photon strikes a crystal, it travels a certain distance before its energy is converted into light. If the photon comes from the center of the field of view (FOV), the line of response (LOR) is likely to be correctly localized in the crystal in which the photon entered. The further away from the center of the FOV, the less likely the LOR will be calculated correctly because the photon will hit the crystal on an angle and continue traveling to another crystal before it lights up.

Point Spread Function (PSF) A Point Spread Function (PSF) describes the response of an imaging system to a point source or point object. A system that knows the response of a point source from everywhere in its field of view can use this information to recover the original shape and form of imaged objects. PSFs are used in precision imaging instruments, such as microscopy, ophthalmology, and astronomy (e.g. the Hubble telescope) to make geometric corrections to the final image.

Time-of-Flight (TOF) Conventional PET detects coincidence photons and records individual lines of response (LOR) between the crystals. The actual location where the annihilation occurred along the LOR is not measured. Siemens ultraHD•PET with Time of Flight (TOF) measures the actual time difference between the detection of each coincidence photon. This timing information is used to better localize the event along each LOR.

x Time-of-Flight (TOF) s c = speed of light Time of Flight (TOF) systems measure the time between each coincidence photon to determine the event location along the line of response. The event location accuracy can be measured proportionally to the system’s time resolution. TOF systems are able to record segments of response instead of lines of response. The time resolution defines the size of the segment of response (“time bin”). Conventional line of response Segments of response (“time bins”) s s => directly proportional to the system’s time resolution T2 x T1 c = speed of light

Future: faster implementations of the reconstruction algorithms other algorithms development (other than ML based) listmode instead of sinogram based dynamic or 4D reconstructions application oriented reconstruction methods (oncology, brain functions, cardiac,..)