Yury Gavrikov 25/03/2009 1. 2  I met with two very nice g…oniometers 3 Because we decided to adapt their for a new experiment.

Slides:



Advertisements
Similar presentations
Particle vs. Rigid-Body Mechanics
Advertisements

BARTOSZEK ENGINEERING 1 The Design of the Booster Collimators Larry Bartoszek BARTOSZEK ENGINEERING 3/10/03.
Bent Crystal Results to Date Feb 26, 2007 D. Still.
Ray Schroeder ET 494 Senior Design II Advisor: Dr. Cris Koutsougeras Fall Semester /5/2014.
Development of a mover having one nanometer precision and 4mm moving range Y. Morita, S. Yamashita ICEPP, University of Tokyo Y. Higashi, M. Masuzawa,
Yury CHESNOKOV Crystal Collimation workshop, March 7, 2005 CALIBRATION of CMS CALORIMETERS with LHC PROTON BEAM DEFLECTED BY CRYSTAL CALIBRATION of CMS.
1 Long-term Variation of the Magnet Alignment In SPring-8 Storage Ring Main events of magnet alignment Long-term monitoring Variation of magnet alignment.
X-Ray Survey of The ATLAS SCT. The ATLAS Semi-Conductor Tracker.
POWER TRANSMISSION with BELTS & CHAINS
Use of a commercial laser tracker for optical alignment James H. Burge, Peng Su, Chunyu Zhao, Tom Zobrist College of Optical Sciences Steward Observatory.
Isaac Vasserman Magnetic Measurements and Tuning 10/14/ I. Vasserman LCLS Magnetic Measurements and Tuning.
MICE Collaboration Meeting March 29 - April 1, CERN MICE alignment, tolerances and supports Tuesday March 30 Room Edgar Black/IIT March17-
X-Ray Survey of The ATLAS SCT. The ATLAS Semi-Conductor Tracker.
MICE Alignment and Support Structure Tony Jones and Yury Ivanyushenkov Engineering Department RAL.
How to support a shaft? The motor just turns the shaft. It doesn’t provide any support.
Procedure I  Set Up Level the experiment using the threaded feet, making sure that the mirror is hanging freely in the center of the case, and center.
Capstone Team  Andre Nylund  Chris Grewell  Craig Lechtenberg  Fadel Al Jutail  Matt Melius  Mufeed Yacoub Team Advisor  Dr. Raul Bayoán Cal Customer.
T-980 Crystal Collimation Recent Results T-980 Collaboration: FNAL, SLAC, BNL, CERN, PNPI, IHEP, INFN D. Still CM14 April 27, 2010.
Support and alignment of PXL box with MSC, operation steps
MARS 2 Design Review-Optomechanical Review 07 Nov 2002 GLW1 MARS 2 Mechanical Design Review.
NEW COMMENTS TO ILC BEAM ENERGY MEASUREMENTS BASED ON SYNCHROTRON RADIATION FROM MAGNETIC SPECTROMETER E.Syresin, B. Zalikhanov-DLNP, JINR R. Makarov-MSU.
Servo Motor Control. EML 2023 Department of Mechanical and Aerospace Engineering Design Problem You are to design an automated goalie for an air hockey.
Disturbance Rejection: Final Presentation Group 2: Nick Fronzo Phil Gaudet Sean Senical Justin Turnier.
HPS Collaboration Meeting JLAB, May Tracker Design Status M.Oriunno, SLAC.
Mechanical Structure „Pi of the Sky” robotic telescope mgr inż. Robert Pietrzak mgr inż. Piotr Wawer mgr inż. Roman Wawrzaszek –
D. Missiaen Summaries of the discussion. 2 H. Mainaud Durand The iris diaphragm laser alignment system for Spring 8 storage ring magnets Align multipoes.
Magnet Measurement Device for MICE F. Garnier, P-A. Giudici, F.Bergsma CERN MICE Collaboration Meeting No. 29 RAL technical drawings by O.Jamet.
LIGO-G D LIGO II1 AUX OPTICS SUPPORT Michael Smith, 6/11/03 STRAY LIGHT CONTROL ACTIVE OPTICS COMPENSATION OUTPUT MODE CLEANER PO MIRROR AND PO.
A Double Crystal Monochromator of Sagittal Focusing at SSRF J.H. He, S.J. Xia, Z.C. Hou, J.L. Gong, X.M. Jiang and Y. Zhao SSRF Project Team Shanghai Institute.
RUDE Vivien With the help of Hélène MAINAUD-DURAND And Mateusz SOSIN BE/ABP/SU CLIC MODULE September 19, 2011 Présentation REPORT OF THE CURRENT TESTS.
Engineering Division 1 M321/M331 Mirror Switchyard Design Review Tom Miller
GONIOMETER FOR TEST BEAM MEASUREMENTS Yury Gavrikov (PNPI, Gatchina, Russia) UA9 Collaboration meeting
Oct 17, 2001SALT PFIS Preliminary Design Review1 Southern African Large Telescope Prime Focus Imaging Spectrograph Mechanical Mechanism Design Michael.
A. Bertarelli CERN TS – MME Group 1 CERN European Organization for Nuclear Research Actuating system of the LHC Collimators (Phase 1) Main Features.
SPS UA9 data taking run with LHC-type Goniometer 31/07/2015 – Collimation Upgrade Specification Meeting #60 Roberto Rossi Daniele Mirarchi, Stefano Redaelli,
HiRadMat box relative to beam position and vertical lift table.
Integration with LDC & Push-pull impact on LumiCal Wojciech Wierba Institute of Nuclear Physics PAN Cracow, Poland FCAL Workshop, LAL Orsay,
LHC Crystal MD 22/09/2015 – LSWG #7 R. Rossi for the LHC Collimation team and the UA9 Collaboration.
Calibration and production of PRAXIAL (*) sensors for the ATLAS muon spectrometer Optical Metrology - SPIE Optical Measurement Systems for Industrial Inspection.
Contents: 1. Introduction 2. Gyroscope specifications 3. Drift rate compensation 4. Orientation error correction 5. Results 6. Gyroscope and odometers.
SPS movable table Joanna Swieszek, Kurt Artoos (EN-MME) 14/04/2016.
EE 495 Modern Navigation Systems
Design for a New Optical Table of the Shintake Monitor Takashi Yamanaka The University of Tokyo ATF2 weekly meeting 2007/9/26.
Accuracy of the orbit measurement by KEKB BPM system for the study of ILC damping ring H. Fukuma (KEK) Requirement for the accuracy of BPM data.
The Alignment of DTL in CSNS Institute of High Energy Physics, CAS KE Zhiyong
Angular Kinematics of Human Movement Biomechanics and ergonomics.
Automatic DCDT Calibration Device Chas Bolton
T980 STATUS AND CHANGES FOR
First clues on ET payload sensing and control
Liquid LVs propellant consumption control terminal system
Mechanical Design Review February 25, 2008 Université de Montréal
10th stabilization meeting
VIRGO–KAGRA Meeting about bottom filter damping
Proposal of Piezo Goniometer for LHC Channeling experiment
ROTATIONAL MOTION Rotation axis: rotation occurs about an axis that does not move: fixed axis.
Review on collimator movement with stepping motors
TATVA INSTITUTE OF TECHNOLOGICAL STUDIES, MODASA (GTU)
JINR: J. Budagov, M. Lyablin., G. Shirkov.
LumiCal mechanical design, integration with LDC and laser alignment
POWER TRANSMISSION with BELTS & CHAINS
Interferometric measurements on mirrors
Motion Stage for Optical Coherence Tomography
Review on collimator movement with stepping motors
A movement of a figure in a plane.
Multi Stage Engineering
IENG 475: Computer-Controlled Manufacturing Systems
P09045: Membrane Characteristic Test Stand
Motion Control on ESS Test Beam Line
IENG 475: Computer-Controlled Manufacturing Systems
Undulator Physics Issues Heinz-Dieter Nuhn, SLAC / LCLS July 11, 2007
Presentation transcript:

Yury Gavrikov 25/03/2009 1

2

 I met with two very nice g…oniometers 3 Because we decided to adapt their for a new experiment

Gear box Belt drive + “virtual” screw Engine DC-servo motor Carriage slides on the 2 guides 4

Inside of beam Outside of beam 5

 Angular movement 1mm Angule ~15mrad ~63mm Axis PusherPusher Angle Stepper motor & Belt drive Microscrew 6

Unificated solution for angular & linear motion: Stepper motor for driving LVDT for position measurement Common Control system for all devices It was needed the mashining of original parts 7

After modernization during last month before installation : - 4 revisions and full disassembling - A lot of motion tests and measurements - Fixing of sources of the problems 8

9

 Digital Autocollimator specially designed for the experiment Range: ~ 8000  rad (horizontal) ~ 6500  rad (vertical) Resolution:< 0.5  rad 10

 The general Idea of angle measurement Mirror 11

 The Idea of crystal angle calibration Reference mirror Crystal 12

 Angle vs. LVDT position Goniometer 2Goniometer 1 13

Periodical structure corresponds to the motor revolution Nonlinearity : about +/- 50  rad 14

15 The goniometers are very SENSITIVE to any mechanical disturbance The design is SOFT. “Don’t touch” should be placed everywhere We can move it only in work direction to avoid all gaps  Mechanical stability

16  Stability of LVDT during 14 hours looks quite good (*) Gonio2, LVDT 3-5  rad (*) with averaging to reduce the noise

 Preliminary estimation for angular motion 17

18

19 Crystal 1 Crystal 2 Ref. mirror

Digital autocollimator Reference mirror Laser 20 Penta prizm Viewport

Initial orientation of the alignment rail to the tank geometry +/- 350  rad Nonlinearity of goniometers +/- 50  rad 21

We can use this goniometers with some magic gestures right now BUT To reach better results in the future we have to develop a new goniometer 22