TETRA Data Applications for Gas and Oil Dubai, September 2013 Funk-Electronic Piciorgros GmbH Michael D. Piciorgros (CEO)

Slides:



Advertisements
Similar presentations
Integrating Opengear console servers into Zenoss monitoring.
Advertisements

Ethernet Switch Features Important to EtherNet/IP
Welcome to the Radionet Monitoring Secure-Com Presentation.
Wireless Controllers. Building block for remote control & alarming Functions Local control Measurement SMS alarming Remote control via SMS Data transmission.
Arctic IEC-104 Gateway Jari Lahti, CTO.
POC Security System High security system combining PIN-on-Card, information security, physical access, control and alarm – all in one system.
Multi-Loop PID Controllers All Watlow® multi-loop time/temperature controllers offer auto-tuning which automatically sets PID control parameter for optimum.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Poseidon 4002 Rack monitoring 1. Poseidon: Monitor & Control 2.
Niobrara R&D Corp Compact PLC Upgrades With the CERI.
ATiM Spécialiste en étude et développement de produits de radiocommunication
Supervisory Control & Data Acquisition Communication Technology Modbus Protocol.
Remote Monitoring and Management Solutions ®
12-Port IP Power Manager IPM  Product Overview  Product Features  Applications  Comparison Presentation Outline 2 / 15.
PLC Based Residential Alarm System John Hiddema University of Idaho - ECE Spring 2012.
OVERVIEW TBOX The best of 3 worlds.... TBOX The best of 3 worlds...  best of Automation  best of Internet  best of Telemetry.
Finding That Elusive Pot of Gold or Networking Your Shelter Rebecca Peltzer & Jennifer Bradley, Polk County – Air Quality Steve Drevik, Agilaire.
Presentation on behalf of the TETRA + Critical Communications Association TCCA SCADA, Smart Grid and Telemetry Group January Member’s products,
ADAM-4572 Ethernet To Modbus Solution Ethernet to Modbus Data Gateway
Applying Wireless in Legacy Systems
Opportunities for TETRA In the Oil & Gas Industry Robin Davis - Group Director Technology 2 nd Middle East Conference, Dubai 18 th May 2004.
Annarita Giani, UC Berkeley Bruno Sinopoli & Aakash Shah, Carnegie Mellon University Gabor Karsai & Jon Wiley, Vanderbilt University TRUST 2008 Autumn.
Slide 1 / 20 Industrial Automation - Custumer View - Services PhW - Modbus_en 06/ 2002 Modbus training.
Make the most of your energy June 2008 Power Meter 800 PowerLogic ® Power Meter 8ECC.
ADAM-5000/TCP- Distributed Ethernet I/O
eAutomation Enabler – Advantech Industrial NETworking
FAQs and Overview on SCADA, Telemetry and Telecontrol using TETRA-Infrastructure Funk-Electronic Piciorgros GmbH Michael D. Piciorgros (CEO)
TETRA-RTU and TETRA-Modem TMO-100
G4 Control and Management Solution for Data- Centers and Computer Rooms.
1 © Red Lion Controls Inc. Introducing the RAM 9000.
IRRInet & ICC System Concept
SCADA FOR WATER DISTRIBUTION IC DEPT. GECGn SEC28.
A BRIEF INTRODUCTION TO FIELDBUS 4 hf NETLOGIC PLC TRADITIONAL CABLING SYSTEM TERMINAL BOARD.
A modern NM registration system capable of sending data to the NMDB Helen Mavromichalaki - Christos Sarlanis NKUA TEAM National & Kapodistrian University.
Operator Panel and Programmable Logic Controller.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate.
DVI-100 Digital Voice Interface for TETRA-Infrastructure September 2013 Funk-Electronic Piciorgros GmbH Dipl.-Ing. Michael D. Piciorgros (CEO)
April 2011 November 2010.
1 Monitor System Reliability alarm on demand, sag/surge, and etc. Perform Advanced Power Quality Analysis provide real-time trending. Centralized.
Optimization of DATA Transmission for Transport Sector User case, TMB David Lumbreras Project Area Manager.
Make the most of your energy December 2008 PM8ECC Need improved Network capabilities out of your meter? PowerLogic ® PM8ECC.
TETRA ARCHITECTURE AND INTERFACES
Unit 5 CONTROL CENTERS AND POWER SYSTEM SECURITY.
FMUX01-A Copyright (c) 2003, 2004, CTC Union. All rights reserved.
1 Weblite Product Introduction. 2 Control Equipment via the Internet 8 Universal Inputs 8 Universal Outputs software selectable as analog or digital signals.
M340 Modbus Plus Proxy Link legacy systems to Ethernet
TGW-100 Interfacing SCADA Applications to TETRA infrastructure
New product introduction:
TETRA Modem TMO-100 Change and Upgrade Information for Version V3 May 2015 Funk-Electronic Piciorgros GmbH.
1 Who (what) is SAM?. 2 WORLD’S FIRST SAM.
11111 Apollo Internet Monitoring Tutorial Apollo Solar, Inc. 23 F. J. Clarke Circle Bethel, CT (203)
InDTU Intelligent Cellular Modem InHand Networks Monthly Webinar - European Session June 2013.
Remote monitoring solutions to protect mission critical infrastructures Remote monitoring and control solutions to guard your mission-critical IT equipment.
Artificial Intelligence In Power System Author Doshi Pratik H.Darakh Bharat P.
ESTeem 195 Narrowband Series
TETRA-RTU and TETRA-Modem TMO-100
MDC-700 Series Modbus Data Concentrator [2016,05,26]
SCADA for Remote Industrial Plant
Distributed Control for drives
DT80 range Modbus capability
SCADA and Telemetry Solutions via DMR DMM-100 / DGW-100
NT24k® & 1000 PoE+ Offerings October 2016.
DVI-100 Digital Voice Interface for TETRA-Infrastructure
Integrated gateway-server
DVI-100 Digital Voice Interface for TETRA-Infrastructure
Presentation transcript:

TETRA Data Applications for Gas and Oil Dubai, September 2013 Funk-Electronic Piciorgros GmbH Michael D. Piciorgros (CEO)

Piciorgros GmbH * Germany Why and not …. P25 DMR WiMAX WiFi GSM, Edge, 2G, 3G, (4G) Other digital Wireless Systems

Piciorgros GmbH * Germany … because ? Try to compare all technical and commercial aspects of the following presentation with the optional technologies and the decision will be easy!

Piciorgros GmbH * Germany Requirements for Gas and Oil Applications

Piciorgros GmbH * Germany Typical Requirements for Gas and Oil Remote measurement of physical values at the Wellheads: Temperature Pressure Flow Rate Alarms Measurement for Cathodic Corrosion Protection (CP): Voltage Current Alarms Siren Alarming at Plants Action in Control Direction (from Control Room) Leak Detection (and other) Alarms Action in Alarm Direction (to Control Room)

Piciorgros GmbH * Germany SCADA Requirements Different PLC (RTU) Vendors: Siemens Emerson General Electric Schneider Electric Different Protocols that are used for different Oil Fields: DNP3, Modbus RTU, Modbus ASCII Sinaut, IEC Modbus ASCII ROC, BSAP,... and more Number of PLC (RTU) per Application Can differ from 2-3 up to several hundred per Oil Field

Piciorgros GmbH * Germany CP (Cathodic Protection) Requirements Low Polling speed: Polling can be one per hour or even less Direct Access of Voltage and Current from Gas or Oil Pipeline: Low data volume and low data speed application Embedded I/O Requirement from TETRA device

Piciorgros GmbH * Germany Additional Requirements: Secured Communication: Authentication Encryption On Shore and Off Shore Applications (Oil Platforms) Parallel use of Voice and Data Wide Temperature operating range Mixed IP and non IP based Data Communication Over The Air (OTA) Software Upgrade Remote Configuration Access to Outstations via WEB Browser

Piciorgros GmbH * Germany How many Gas and Oil sites can be polled with TETRA? Typically a complete polling cycle for Gas and Oil Application should not last more than 5 minutes. Assuming that a polling cycle with the Modbus RTU or DNP3 protocol over TETRA with SDS lasts one Second, 60 sites could be polled per one minute and 5 * 60 sites = 300 sites in 5 minutes on one (of the four) TETRA time slots When using a TETRA Data Gateway like the TGW-100, multiple polling nodes can use the same TETRA time slot in parallel without reducing the polling rate. And in case that 4 polling nodes will be used, the total number of sites that can be polled in 5 minutes will be: Number of Polling Cycles in 5 minutes = 300 * 4 = 1200 Remark: The 1200 pollings use only one of the four TETRA time slots. Using all time slots would result in 1200 * 4 = 5000 poll cycles within 5 Minutes!

Piciorgros GmbH * Germany TETRA Modem Design

Piciorgros GmbH * Germany TETRA Modem for DIN Rail mounting with two serial Ports, one Ethernet Port and an Audio (voice) Port

Piciorgros GmbH * Germany TETRA Modem as before with additional embedded analog and digital I/O

Piciorgros GmbH * Germany TETRA Data Network Structure Radio-to-Radio Communication

Piciorgros GmbH * Germany SCADA using based Radio-to-Radio Communication SDS SCADA Control Room Tetra Switch PLC / RTU Command and Control Device Public Lighting Serial Communication TMO-100 SDS TMO-100 Serial Interface I/O

Piciorgros GmbH * Germany TETRA Data Network Structures using a Data Gateway for SDS and Packet Data (IP)

Piciorgros GmbH * Germany Highly Redundant TETRA Packet Data and SDS Gateway for SCADA Critical Operation

Piciorgros GmbH * Germany Highly Redundant TETRA Packet Data Gateway for SCADA Critical Operation Supported Protocols: MODBUS-RTU IEC DNP3 ROC BSAP PakBus Siemens SINAUT any customer specific or proprietary protocols

Piciorgros GmbH * Germany Redundant TETRA Packet Data Gateway for SCADA Critical Operation Features: COM Port: RS-232 or RS-485/422 AUX Port: RS-232 or RS-485 Ethernet Port: One (TGW-100) or two (TGW-100R) Ethernet interface: RJ-45, 10/100 MBPS Power Supply: Dual Power Supplies – hot swappable

Piciorgros GmbH * Germany Analog and Digital I/O SCADA – using a TETRA Gateway Tetra Switch PLC / RTU Command and Control Line Device TGW-100 SDS Gateway Two Serial Interfaces IP Communication TMO-100 SDS I/O … or Serial Interface Serial Interface SCADA Control Room SDS

Piciorgros GmbH * Germany Performance Test with SDS-Gateway on ONE SCCH/MCCH: Infrastructure: TETRA with one carrier TETRA Data Link: One SCCH Data Compression: OFF Data nodes: One or more polling nodes, each polling 10 TMO-100 Protocol: Modbus RTU Polling Target: Polling different numbers of bytes from inside the TMO- 100 One NodeTwo NodesThree NodesFour NodesEight Nodes SDS: 20 Bytes SDS: 100 Bytes 285 SDS: 200 Bytes 265 Table showing polls per minute

Piciorgros GmbH * Germany Performance Test with SDS-Gateway on FOUR SCCH/MCCH: Infrastructure: TETRA with one carrier TETRA Data Link: MCCH plus three SCCH Data Compression: OFF Data nodes: One or more polling nodes, each polling 10 TMO-100 Protocol: Modbus RTU Polling Target: Polling different numbers of bytes from inside the TMO- 100 One Node (on each TS) Two Nodes (on each TS) Three Nodes (on each TS) Four Nodes (on each TS) 16 Nodes (on each TS) SDS: 20 Bytes SDS: 100 Bytes SDS: 200 Bytes Table showing total polls (on all time slots) per minute (values rounded)

Piciorgros GmbH * Germany Analog and Digital I/O SCADA – using a Gateway Tetra Switch PLC / RTU Command and Control Line Device, CP Interface TGW-100 SDS Gateway Two Serial Interfaces IP Communication TMO-100 PD I/O … or Serial Interface Serial Interface SCADA Control Room Packet Data

Piciorgros GmbH * Germany SCADA – using direct Communication Tetra Switch AMR, PLC or RTU CP, Command and Control Line Device Direct IP Communication to TETRA SwMi TMO-100 IP PD I/O SCADA Control Room

Piciorgros GmbH * Germany TMO-100 TETRA Data Modem Feature List

Piciorgros GmbH * Germany Embedded Web-Browser

Piciorgros GmbH * Germany Embedded IP and TETRA Router

Piciorgros GmbH * Germany Embedded mySCAD Micro SCADA

Piciorgros GmbH * Germany Embedded mySCAD Micro SCADA

Piciorgros GmbH * Germany PLE - Powerful Java Graphic Editor

Piciorgros GmbH * Germany No Cryptic Formulas for Logic design

Piciorgros GmbH * Germany Powerful embedded Micro PLC

Piciorgros GmbH * Germany TMO-100 TETRA Data Modem Features

Piciorgros GmbH * Germany TMO TETRA related Features SDS can be up to 255 bytes (2047 Bit) long. Type TL and TL 4 Packet Switched Data (IP) supported Single and Multi Slot Packet Data supported Secondary Control Channel supported Automatic PPP Link set up to the TETRA Switch Router Function with Port Forwarding and NAT Up to 3 Watt RF Output Power Authentication, Encryption Voice feature even with active Packet Data Link Build in Tetra Monitor (local and remote) via embedded Web Server Field Strength Indicator on the Front Panel Short Data or SDS can be sent as alarms (low field strength...) 350 MHz, 380 MHz, 410 MHz 450 MHz and 800 MHz available

Piciorgros GmbH * Germany TMO-100 – Protocol and I/O related Features All digital and analog I/O isolated Serial Port COM / AUX available as RS-232 or RS-485/(422) Level 1 Protocol: Timeout or 3964R Device Protocol to access internal Registers: Modbus RTU, Modbus IP, IEC Serial Protocols supported: Modbus RTU, DNP3, IEC , PakBus, BSAP, ROC, … user Defined … Ethernet 10/100 MBit IP-Port for Local Network UDP and TCP over TETRA supported and TFTP supported Embedded Web Server as Configuration Tool Modbus/IP, IEC , DNP3/IP, … others … Low Power Consumption: <3 Watt

Piciorgros GmbH * Germany PicoLogo ™ – User Application Interface Easy to use graphical user interface Optimized for Tetra Infrastructure Basic Logic Functions (and, or, exor, … ) Complex Logic Functions (delay on, delay off, flip flop, …) Analog Functions (analog compare, … ) Timer and Clock Functions (time, date, Dynamic Text Message generation for Alarms and Status GPS Functions (position, … ) Modbus RTU Slave (set and read register, coil, … ) Modbus RTU Master (set and read register, coil, … ) send (sending text and alarm messages by ) SNMP Trap (automated machine messaging) … more …

Piciorgros GmbH * Germany TMO-100 – Embedded Web Server Web Server to be used local or over TETRA as … Configuration Tool for the Device, Protocols and IP Parameter, Configuration Tool for TETRA Network Parameter, Configuration for the Voice Option TETRA Monitor Device Monitor Error Log Web Server can be accessed locally using the IP Port and remotely over the TETRA Infrastructure Easy to be used with any Web Browser (Firefox, Internet Explorer, … )

Piciorgros GmbH * Germany TMO-100 – Voice Option Standard 8 Pin Connector for Mic. Speaker handset One Group Number (GISSI) to be programmed Eight individual Numbers (ISSI) to be programmed ISSI and GISSI to be programmed locally or remotely using the embedded Web Server Select ISSI / GISSI by Voice Handset Automatic PPP disconnect when pressing PTT Automatic PPP re connect after Voice timeout or reject

Piciorgros GmbH * Germany Different SCADA Applications

Piciorgros GmbH * Germany ME, Gas and Oil

Piciorgros GmbH * Germany Open Pit Mining (Water Level Control)

Piciorgros GmbH * Germany Turkey, Mining Application – TETRA DMO Mode

Piciorgros GmbH * Germany Asia, Utility (Energy Companies) Pole Mounted Switches

Piciorgros GmbH * Germany Waste Water Treatment Plant (Germany)

Piciorgros GmbH * Germany

Funk - Electronic Piciorgros GmbH Claudiastr Köln-Porz Germany Thank you very much for your interest in our Products