Alternative Toroidal Transformer Designs and Measurements September 2, 2003 N. Kitamura University of Wisconsin-Madison / SSEC.

Slides:



Advertisements
Similar presentations
TYPES & CONSTRUCTION OF TRANSFORMERS POWER IN AN IDEAL TRANSFORMER
Advertisements

How they work How they are made
Chapter 13 Transmission Lines
Inductors and Chokes In Switch mode Supplies
Power e Lab PowerELab Limitedwww.powerelab.com 1 An Active EMI reduction IC WT6001 POWERELAB LIMITED A Power Converter Technology Provider.
Energy Storage Devices
1 New high permeability materials for EMI suppression February 2011 February 2011.
Physics 12 Mr. Jean May 6 th, The plan: Video clip of the day AC/DC power generation AC/DC electric engines.
Switching Power Supply Component Selection 7.2a Inductor Selection – Terminology.
ENERGY CONVERSION ONE (Course 25741)
12: Electromagnetic Induction 12.2 Alternating Current.
Power I, VI, V I max  V max  I, VI, V I max AC Circuits use a similar definition of power as DC circuits. The one detail that need to be included.
Transformer Voltage Regulation Fact: As the load current is increased, the voltage (usually) drops. Transformer voltage regulation is defined as:
WINDING LOSSES IN HIGH FREQUENCY TRANSFORMERS
Transformers and Coupled Circuits
How Electricity enters in our houses Electricity supplied to us at our home is 220 volt and A.C.. This main line power and the wires carrying it are called.
Electrical Machine-I EE 2107 Dr. Md. Sherajul Islam
Transformers Test Friday 3/30/12. Electromagnetic Induction Induction is the process of producing (inducing) a voltage by passing a wire through a magnetic.
BASIC CONSIDERATIONS IN DESIGN  The aim of the design is to completely obtain the dimensions of all the parts of the machine to furnish the data to the.
Transmission Lines …….. Conductor Material
4. Transformers allow generated voltage to be either increased or decreased before it is used.
CHAPTER 6: TRANSFORMER BAKISS HIYANA ABU BAKAR
Chapter 2 Transformers.
Transformers Mechanical and Electrical Systems SKAA 2032
Transmission lines.
Preliminary Design Review May 20, 2003 PMT HV Base Board Engineering Requirements Nobuyoshi Kitamura SSEC / UW-Madison.
BENE 1113 PRINCIPLES OF ELECTRICAL AND ELECTRONICS
Lecture 2 Most basic facts from Electricity needed for understanding telecommunications Local transmission lines in the telephone system Decibels Signals.
Power Lines The power transmission line is one of the major components of an electric power system. Its major function is to transport electric energy,
Electromagnetism Topic 12.2 Alternating Current. Rotating Coils Most of our electricity comes from huge generators in power stations. Most of our electricity.
Physics 12 Mr. Jean December 10 th, The plan: Video Clip of the day – PIhttp://
ELECTRICAL BASICS (Chapter 8) Electrical terms Electricity & magnetism Electricity Circuits Magnetism Electrical units Electric potential or eletromotive.
PRESENTATION ON TRANSFORMER PREPARED BY: VRUNDA RANA( ) KRIMA PATEL( ) NIKITA THAKKAR( ) ELEMENTS OF ELECTRICAL ENGINEERING.
Transformers. ► Electric Generators- the main function of an electric generator is to convert mechanical energy to electrical energy. ► Electric motors-
Section 3.1: Wires, Cables, and Connectors Scott Glogovsky and Jonathon Sturm Scott Glogovsky and Jonathon Sturm.
Intro to AC. AC Alternating Current Flows in two directions. It can reverse many times per second. Intro to AC.
Generator and Transformer. Moving Conductor If a straight conductor is moved in a path perpendicular to a magnetic field, a current is induced in the.
Chapter 29 Electromagnetic Induction and Faraday’s Law
EKT 451/4 SEM 2 Chapter 6 SENSOR & TRANSDUCER SHAIFUL NIZAM MOHYAR
Production and Control of High Voltage
DIELECTRIC HEATING KUMAR CHATURVEDULA. DIELECTRIC HEATING KUMAR CHATURVEDULA Dielectric heating, also known as electronic heating, RF heating, high-frequency.
PMT HV Base Prototypes Evaluation Instrumentation Workshop LBNL July 23-24, 2003 Nobuyoshi Kitamura University of Wisconsin-Madison SSEC.
Displacement and Motion Measurement
FUNDAMENTALS OF ELECTRICAL ENGINEERING [ ENT 163 ] LECTURE #10 ELECTRICAL MACHINES HASIMAH ALI Programme of Mechatronics, School of Mechatronics Engineering,
Transformer The working principle of a transformer
Balun/Unun Construction
AC Current An AC circuit consists of a combination of circuit elements and an AC generator or source The output of an AC generator is sinusoidal and varies.
EEK260 -Electrical Machines By Dr. Mohamad Kamarol Mohd Jamil Room: 2.32 Ext: 6064.
CCM Power Factor Correction Inductor Design with Powder Core
1 Transducers EKT 451 CHAPTER 6. 2 Definition of a Transducers   Transducer is any device that converts energy in one form to energy in another.  
True-False Questions. A magnetic core material may exhibit hysteresis or saturation but not both.
SWEEP FREQUENCY RESPONSE ANALYSIS AS A DIANOSTIC TOOL TO DETECT TRANSFORMER MECHANICAL INTEGRITY by:Luwendran Moodley Brian de Klerk ETHEKWINI ELECTRICITY.
{ PRESENTATION ON TRANSFORMER. 1. INTRODUCTION: - TRANSFORMER : A static device- Utilized for raising or lowering the voltages. Transfers electrical energy.
TRANSFORMERS  A power station produces an AC pd of ~25 kV  This AC pd is stepped up to ~132 kV so that it can transport through cables without losing.
Electromagnetism Notes-3
TRANSFORMER A transformer is a static device.
TRANSFORMERS.
True-False Questions.
Małgorzata Godlewska, Krzysztof Górecki
PExprt Modeling Procedure
Electric Machine Transformers
Wireless charging FACULTY OF ENGINEERING AND INFORMATION TECHNOLOGY
High-Voltage Supply Requirements Review
University of Wisconsin-Madison / SSEC
IEEE 383 Standard for Qualifying Electric Cables and Splices for Nuclear Facilities Preview SC-2 May 12, 2014 Robert Konnik.
CONSTRUCTION of TRANSFORMERS
Amateur Extra Q & A Study Pool
Applied Electricity and Magnetism
Chapter 14.
CST 450 Flare Stack Cable High Temperature, Fire resistant, High Voltage Single Conductor.
Presentation transcript:

Alternative Toroidal Transformer Designs and Measurements September 2, 2003 N. Kitamura University of Wisconsin-Madison / SSEC

9/2/2003 N. KITAMURA Background Notes The PMT pulse-coupling transformer in the current design employs the RG174 coaxial cable as a winding material (ERD ). The voltage rating of the RG174 cable has come into question (PDR-4), and a justification for the use of RG174 is being sought. The present study investigates the pulse transmission characteristics of a more conventional transformer design, employing a pair of hook-up wires, rather than a single strand of coaxial cable. A typical Teflon hook-up wire has a voltage rating of 600V over –60 to +200C, regardless of the wire gauge size. Apparently, no Teflon-insulated wires have a rating exceeding 2000VDC. So called test-lead wires are rated at sufficiently high voltage for our purpose, but the operating temperature does not go down very low. Since there will be no flexing, that would not be a problem. Braidless-silicone-rubber-insulated wires from Harbour Industries (e.g., Cat # BSR ) are rated at 10 to 50kVDC with a maximum temperature of 150°C.

Table 1 Physical and Electrical Characteristics of the M17/93-RG178 Cable (Source: Center Conductor PTFE Dielectric Diameter Overall diameter Minimum recommend- ed bend radius Operating Temperature ImpedanceCapacitanceMax Operating Voltage ”0.033”0.71”0.4” °C 50 ± 2  29.4 pF/ft1000 Vrms

Extreme temperature applications, -180ºF to 600ºF (-118ºC to 316ºC) Inert, odorless, tasteless, stainless -- ideal for medial and food applications High resistance to weathering and oxidation Excellent electrical qualities -- many superior dielectric and insulation characteristics in special compounds Superior resistance to many chemicals High resistance to ozone and corona Very good thermal resistance -- special flame retardant compounds are available Superior water resistance -- low water absorption. Why Use Silicone Rubber* *Source:Silicone Rubber Right Products, Inc., webpage:

Conclusion The pulse response very similar to that of the RG178 coaxial transformer is obtained from a transformer employing a pair of stranded hook-up wire as the winding material. Silicone-rubber-insulated stranded wire rated at 10-50kV (UL 3239) is readily available in gauge sizes suitable for the transformer winding.  The pulse-coupling transformer with satisfactory pulse-response characteristics and a sufficient operating voltage margin can be constructed without difficulty based on the finding of this study. Proposed specification: Toroidal coreMagnetics Cat. # ZH TC Winding materialHarbor Industries 3239, 22 AWG 7/30, 10kV, 150°C Number of turnsTBD

9/2/2003 N. KITAMURA Samples Sample A: RG174 wound on a toroidal core (18 turns)  Current specification Sample B: Solid 24 gauge wires twisted into a pair and wound on a toroidal core (15 turns). Sample C: Stranded 18 gauge wires wound side-by-side on a toroidal core (10 turns). Two ferrite cores were used: They are similar in dimensions Core #1 was found in the Physics Lab Core #2 is from Magnetics TM as specified in the current design. (Cat # ZH TC)

9/2/2003 N. KITAMURA SAMPLE A SAMPLE C SAMPLE B

Measurement Setup CH3  Input pulse Trace “A” = (CH1 – CH2)  Output pulse The output pulse was measured in a differential mode 9/2/2003 N. KITAMURA CH3 (50  ) DUT 50  100  CH1 (50  ) CH2 (50  ) Mini Circuit splitter HP 8004A Pulse Generator

9/2/2003 N. KITAMURA Sample A (RG174 on core #2)

9/2/2003 N. KITAMURA Sample B (24 AWG twisted pair on core #1)

9/2/2003 N. KITAMURA Sample B’ (24 AWG twisted pair on core #2)

9/2/2003 N. KITAMURA Sample C (18 AWG on core #1)

The output of Sample A is being compared with the output of Sample B and Sample B’. The output of Sample A is superior to that of Sample B and Sample B’. The pulse response does not seem to depend on the choice between Core #1 and Core #2. This is consistent with the understanding that the high- frequency response of the transformer is largely determined by the capacitive coupling between the primary and the secondary, rather than the magnetic coupling. 9/2/2003 N. KITAMURA Comparison between Core #1 and Core #2 Core #1 Core #2

The output of Sample C is practically identical to the output of Sample A. 9/2/2003 N. KITAMURA Comparison between Sample A and Sample C

The Toroidal Ferrite Core Facts ZH – – TC Color = Gray Material type “H” Ferrite Diameter [mm] Height [mm] Material Characteristics* Initial permeability  i = ± 30 % Curie temperature Tc > 250 °C Max. usable frequency< 150 kHz The permeability decreases by a factor of two and the loss factor increases by a factor of two as the temperture is varied from RT to –25 °C. *Source: For detailed data see: ferrite_h_material.pdfferrite_h_material.pdf 9/5/2003 N. KITAMURA

The magnetic permeability of the toroidal ferrite core has a high-frequency cut-off (50%) of about 150kHz, which means that the predominant coupling mechanism for the PMT pulses is capacitive, rather than magnetic. This is demonstrated by the next scope shot that shows a pulse transfer characteristic of a bare RG178 cable with the connections similar to Sample A. It is seen that the bare RG178 cable has a good ac response--the rise-time and the fall-time are comparable to Sample A. The bare RG178, however, has a very poor low-frequency response. 9/5/2003 N. KITAMURA Experiment with a Bare Coaxial Cable

9/5/2003 N. KITAMURA Bare RG178 Cable