There are three distinct types of isolation in a UPS system: the galvanic isolation between input and output, the input isolation between mains and battery,

Slides:



Advertisements
Similar presentations
Grid Connect Inverters NUER 19
Advertisements

Electricity in the Home
CL100D series DSP controlled Uninterruptible power supplies.
B757 Review Questions.
Basic electrical circuitry & applications
An Electronic System Power Supply Example
Submitted by: Name:Rajendra Kumar Choudhury Branch:Electrical Engg.
G.E. UPS Productline.
Surrey Fire & Rescue Service provides a 24/7 '999' call centre available to all residents and visitors to their county as well as supporting cover to neighbouring.
Uninterruptible Power Supply (UPS)
Tesco PLC has awarded the contract to maintain its uninterruptible power supplies (UPS) at its nationwide distribution centres to Uninterruptible Power.
The battery plays a key role in the overall reliability and availability of a power protection system. It supplies the energy required by the critical.
LP33 Series UPS kVA 400Vac/CE
1 Presentation Protect ph ~ / 3 ph ~ transformerless 3 ph ~ / 1 ph ~ 3 ph ~ / 3 ph ~ PROTECT PROTECT PROTECT PROTECT
High availability is one of the most important issues in computing today. Understanding how to achieve the highest possible availability of systems has.
LHC UPS Systems and Configurations: Changes during the LS1 V. Chareyre / EN-EL LHC Beam Operation Committee 11 February 2014 EDMS No /02/2014.
AC Power Supplies Applications –Standby source for “critical” loads (computer) –Primary source when normal ac not available Uninterrupted Power Supply.
Chapter 4 DC to AC Converters ( Inverters )
Delta Confidential DES UPS introduction UPS training June 2006 Markus Schwab.
Instrumentation & Power Electronics
Data centres are dynamic computer environments. In recent years the increasing mix of old and new computer technologies is causing the overall power factor.
POWER SUPPILES LECTURE 20.
During a mains supply interruption the entire protected network is dependent on the integrity of the UPS battery as a secondary source of energy. A potential.
UPS series PROTECT 1.M Scalable UPS in n+x technology Modularity with double conversion UPS modules True sine wave - output.
The primary objective in the implementation of a UPS system is to improve power reliability to the limits of technical capability, the ultimate aim being.
LECTURE 28 AC Voltage Controllers Dr. Rostamkolai
THE ELECTRIC SUB STATION
SitePro UPS 400Vac / CE GE Consumer & Industrial August 2004.
Lesson 9: Electrical Components
Uninterruptible Power Systems
MarsⅡ On-Line UPS Series
Power Conditioners and Uninterruptible Power Supplies
Whenever the public are involved, safety is always a primary concern. Theatres are no exception and require total reliability from their emergency applications.
LP Series U Technical presentation ISO 9001 UL CUL FCC Class A CE.
LECTURE 25 Controlled Rectifiers Dr. Rostamkolai
Chapter 6 Voltage Regulators By En. Rosemizi Bin Abd Rahim EMT212 – Analog Electronic II.
Grid connection of distributed generation
Power Protection Stowe Australia Welcomes QESTnet Data Centre Construction Workshop Seminar Stowe Australia Welcomes QESTnet Data Centre Construction Workshop.
EMT212 – Analog Electronic II
Diode Rectifier Circuits Section 4.5. In this Lecture, we will:  Determine the operation and characteristics of diode rectifier circuits, which is the.
LP Series 400V CE GE Consumer & Industrial September 2004.
Diode rectifiers (uncontrolled rectifiers)
TECHNICAL PAPER ON SIMULTANEOUS AC-DC POWER TRANSMISSION
Rectifier A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which.
Bridge Rectifier Circuit with Working Operation and Their Types.
CLOSED LOOP SPEED CONTROL OF DC MOTOR WITH PWM TECHNIQUE
A DSP based on on-line UPS R.Padamaja G.Mamatha Reddy EEE EEE S.V.C.E S.V.C.E BY.
C.K.PITHAWALLA COLLEGE OF ENGINEERING & TECHNOLOGY.-SURAT Prepared By: Brijesh Patel Viresh Dadia Fazal Ghanchi Vahora
Chapter 6: Voltage Regulator
Presented by Under the esteemed guidance of D.GANGADHAR REDDY, M. Tech. Asst. Prof., EEE Department UNIVERSAL COLLEGE OF ENGINEERING & TECHNOLOGY AUTO.
SMPS.
AHMEDABAD INSTITUTE OF TECHNOLOGY
Uninterruptible Power Supply (UPS)
Rectifiers, Filters and Regulator
Auxiliary power supply (APS) Hossein Harimi 2014
Rectifiers, Inverters & Motor Drives
AUTOMATIC STREET LIGHT CONTROL USING LDR
Chapter 27 Power Supplies.
Visit for more Learning Resources
Fault detection Lecture (3).
LECTURE 1 (Ch. 1) INTRODUCTION
ECE 442 Power Electronics Text:
Power Semiconductor Systems II
Robicon Perfect Harmony.
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Why AVRs fail to protect Power-sensitive Equipment!
P2 - Physics Mains Electricity.
Power Conditioners and Uninterruptible Power Supplies
Why AVRs fail to protect Power-sensitive Equipment!
Presentation transcript:

There are three distinct types of isolation in a UPS system: the galvanic isolation between input and output, the input isolation between mains and battery, and the isolation between the dc circuit and the UPS output. It is important to understand the distinction between these types of isolation in order to avoid misinterpretation of specifications. Galvanic isolation input/output In transformer-based UPS systems the transformer is used to step up the voltage at the output of the inverter to a voltage compatible with the utility or generator supply voltage. A common misconception is that the transformer is also used to provide galvanic isolation, which is not the case. In transformer- based UPS systems, the neutral line passes through the bypass line and therefore no galvanic isolation between UPS input and output is provided. If a true and total galvanic isolation is required in transformer-based or transformerless UPS, an additional transformer is necessary at the output of the UPS, so that a galvanic isolation from the load is provided for both the inverter and bypass. Input isolation between mains and battery In the early 60s, when only open lead-acid batteries were available, galvanic isolation was required for safety reasons. Since the late 80s, when the maintenance-free lead-acid or nickel-cadmium batteries came into use, input galvanic isolation was abandoned. Today this isolation is very rare. DC-component output isolation Transformer-based technology As mentioned above, in transformer-based UPS systems the transformer is used to step up the voltage at the output of the inverter to a voltage compatible with the utility or generator supply voltage. Furthermore, the transformer isolates DC components, and therefore the inverter transformer isolates the DC circuit from the output load. Figure 1 shows a block diagram of a transformer-based, double- conversion UPS system. It can be seen that the transformer is on the output of the inverter and not on the output of the UPS. White paper: Isolation in UPS systems In PowerWAVE UPS, the addition of an EDCP system provides effective protection from the DC component Figure 1 Transformer-based UPS There are two possibilities for the DC component to pass from the UPS to the load – when there is an inverter IGBT fault or a bypass thyristor fault. UPS

In the event of an inverter IGBT fault – if, for example, IGBT 2 of the inverter does not conduct – a DC component will be generated, and in the transformer-based UPS the output inverter transformer will isolate the inverter DC component from the load (Figure 2). Figure 2 The effect of an IGBT fault in a transformer-based UPS Figure 3 The effect of a bypass thyristor fault in a transformer-based UPS In the event of a bypass thyristor fault – if, for example, one of the thyristors does not conduct – a considerable DC component will feed the load as the transformer does not isolate the bypass. The transformer-based UPS does not control this DC component (Figure 3). Transformerless technology As transformerless UPS technology (Figure 4) does not provide an inverter output transformer, the DC- component issue must be handled differently. The DC component is blocked at the output by hardware and software regulation and control so that it cannot be fed to the load. The transformerless UPS behaves as follows in the two cases. Figure 4 Transformerless UPS In the case of an inverter IGBT fault – if, for example, IGBT 2 of the inverter does not conduct – a DC component will be generated. Transformerless UPS technology handles the DC component by means of a fully-redundant EDCP (electronic dc protection) system, so that the probability of a DC component appearing at the inverter output is practically zero (Figure 5). How does the EDCP system in PowerWAVE transformerless UPSs work? UPS

Figure 5 The effect of an inverter IGBT fault in a transformerless UPS The PowerWAVE UPS is provided with a fully-redundant EDCP system on the inverter side consisting of three parts. Firstly, redundant DC-component regulation continuously detects (double, redundant detection) and regulates (double, redundant regulation) the DC component within a tolerance of ±10mV. Note that a normal mains supply to which all non-protected equipment is exposed has a DC-component tolerance of ±300mV. Secondly, redundant DC-component control continuously detects (double, redundant detection) the DC component, and if it is higher than 4V the DC-component control circuit (double, redundant control) will automatically and instantly transfer the load to bypass. The inverter, rectifier and booster will be switched off, and the battery will be disconnected. The alarm DC-COMPONENT FAULT will appear. To make sure the DC component does not appear on the load side, the EDCP system operates at all times, even if the UPS is in LOAD-OFF mode. Bearing in mind that the DC-component detection, regulation and control circuits are redundant, this makes the EDCP system very safe and secure. Thirdly, a DC component may appear on the output if one IGBT fuse blows and the other IGBT continues to conduct. The PowerWAVE inverter bridges are designed in such a way that if one of two vertical fuses (F1 or F2) blows the other fuse will also automatically blow, preventing the DC component flowing to the load. Using advanced electronic technology, the EDCP system is extremely reliable. The probability of a DC component passing through a transformerless EDCP system is no higher than the probability of a transformer going short circuit (and allowing the DC component to pass). Furthermore over 6000 PowerWAVE three-phase transformerless UPS systems are operating and being protected by the EDCP system, without a single case of a DC component appearing on the load. Figure 6 The effect of a bypass thyristor fault in a transformerless UPS In the case of a bypass thyristor fault, PowerWAVE UPS are provided with an additional EDCP system on the bypass side, which detects if one of the static bypass SCRs is not conducting. In this event, the load will be automatically transferred to inverter within 2 to 5ms in order to avoid a DC component on the load side. UPS

Contact Uninterruptible Power Supplies Ltd Bacchus House Calleva Park Aldermaston Berkshire RG7 8EN Phone: Web: UPS High reliability In the PowerWAVE transformerless UPS, the addition of the EDCP system on the bypass side provides more effective overall protection from the DC component than simply having a transformer on the inverter side.