3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 1 3.2.2 Performing DOT Cylinder Evacuation and Vapor Flaring Operations Before DOT cylinder.

Slides:



Advertisements
Similar presentations
Compressed Gases Slide Show Notes
Advertisements

Using Gas Welding Equipment
Installing & Testing Regulators
3.4.5 Student Book © 2004 Propane Education & Research CouncilPage Maintaining Bulk Plant Pumps, Strainers and Bypass Systems Knowing how to maintain.
Student Book © 2004 Propane Education & Research CouncilPage Placing Appliances into Initial Operation Knowing the proper techniques and.
3.1.9 Student Book © 2004 Propane Education & Research CouncilPage Replacing Valves and Fittings in ASME Tanks Replacing ASME tank valves and fittings.
3.3.3 Student Book © 2004 Propane Education & Research CouncilPage Operating a Dispenser to Fill DOT Cylinders Operating a dispenser to fill DOT.
4.2 Student Book © 2004 Propane Education & Research Council Preparing and Installing Vapor Distribution System Components 4.2.
SAFE PROPANE TORCH USAGE
3.7.6 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Conducting Container Vapor Flaring Operations Before.
Student Book © 2004 Propane Education & Research CouncilPage Installing Vapor Meters Vapor meters are precision measuring devices that.
L. P. Gas Changing Tanks. Introduction L.P. gases belong to a family of chemical compounds known as hydrocarbons. This means they are made up of hydrogen.
3.7.4 Student Book © 2004 Propane Education & Research CouncilPage Identifying Testing Procedures for Anhydrous Ammonia (NH3) Contamination Because.
3.4.6 Student Book © 2004 Propane Education & Research CouncilPage Maintaining Bulk Plant Compressors Knowledge of the processes involved in maintaining.
2.3.9 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Purging Containers & Injecting Methanol Prior to.
3.6.2 Student Book © 2004 Propane Education & Research CouncilPage 1 Many propane marketers receive railcar bulk propane shipments. Well-trained personnel.
7.3.2 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Components and Operating Characteristics of Electronic Ignition.
MODULE 3 Sources and Physical Properties of Propane.
1.1.2 Student Book © 2004 Propane Education & Research CouncilPage 1 A basic knowledge and understanding of propane’s physical properties and characteristics.
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
2.3.6 Student Book © 2004 Propane Education & Research CouncilPage Performing a Walk-Around Inspection of the Transport After Loading Performing.
Student Book © 2004 Propane Education & Research CouncilPage Installing Manifold Cylinders or Tanks When installing manifold DOT cylinders.
4.1.7 Student Book © 2004 Propane Education & Research CouncilPage Selecting Regulators for Vapor Distribution Systems Regulators are mechanical.
4.1.6 Student Book © 2004 Propane Education & Research CouncilPage Designing Underground ASME Tank Installations A very important decision in designing.
3.1.5 Identifying Procedures for Evacuating ASME Tanks at Bulk Plants or at Customer Locations A full understanding of the operation of the liquid evacuation.
Student Book © 2004 Propane Education & Research CouncilPage 1 To provide safe and efficient transporting of bulk containers, such as ASME tanks.
MODULE 7 Unload a Cargo Tank Motor Vehicle (CTMV).
2.5.6 Student Book © 2004 Propane Education & Research CouncilPage Operating a Propane Dispenser to Fill Vehicle-Mounted ASME Tanks To safely and.
5.1.2 Student Book © 2005 Propane Education & Research CouncilPage 1 NFPA 58, LP-Gas Code, sets out the minimum valve and fitting requirements for propane.
3.4.2 Student Book © 2004 Propane Education & Research CouncilPage Types and Functions of Valves and Fittings Used in Bulk Plant Containers and.
3.6 Student Book © 2004 Propane Education & Research Council 3.6 Performing Railcar Product Transfers.
Student Book © 2004 Propane Education & Research CouncilPage Applying Protective Coatings to Storage Containers ASME tanks require proper.
3.7.5 Student Book © 2004 Propane Education & Research CouncilPage 1 A full understanding of the operation of the liquid evacuation process if essential.
5.1.5 Student Book © 2005 Propane Education & Research CouncilPage 1 Specific measures are required by the LP-Gas Code for the prevention of dispenser.
3.5.7 Student Book © 2004 Propane Education & Research CouncilPage 1 Following the proper procedures for filling bobtails is essential to a safe and efficient.
In this module you will learn to identify:
In this module you will learn to:
2.5.3 Student Book © 2004 Propane Education & Research CouncilPage Verifying Proper ASME Tank Condition Prior to Loading For the safe and efficient.
Left side compressor behind Left control box Right side compressor behind Right control box.
Designing and Installing Exterior Vapor Distribution Systems
Placing Vapor Distribution Systems and Appliances into Operation MODULE 8 System Tests.
Student Book © 2004 Propane Education & Research CouncilPage Purging Vapor Distribution Lines & Appliances Purging is the controlled displacement.
4.2.8 Student Book © 2004 Propane Education & Research CouncilPage Installing Aboveground ASME Tanks Installing aboveground tanks is an important.
3.4.7 Student Book © 2004 Propane Education & Research CouncilPage Examining Bulk Plant Electrical Systems Prevention of gas ignition in transfer.
7.3.5 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Function and Characteristics of Draft Fans & Controls High efficiency.
3.7.3 Student Book © 2004 Propane Education & Research CouncilPage Identifying Safe Handling Practices for Flammable and Combustible Liquids Injecting.
5.1.9 Student Book © 2005 Propane Education & Research CouncilPage Installing Propane Dispensers Successful propane dispenser installations are.
7.3.4 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Components and Operating Characteristics of Limit and Fan Controls.
MODULE 6 Vehicle Parking, Servicing, and Security.
Student Book © 2004 Propane Education & Research CouncilPage Reducing Cargo Tank Vapor Pressure Using a Plant Compressor In order to use.
3.4.3 Student Book © 2004 Propane Education & Research CouncilPage Bulk Plant Emergency Shutdown Equipment and Periodic Examination Methods One.
7.4.3 Student Book © 2005 Propane Education & Research CouncilPage Identifying Systematic Troubleshooting Techniques and Guidelines for Gas Operated.
5.1.6 Student Book © 2005 Propane Education & Research CouncilPage 1 Selection of proper dispenser transfer hoses, end valves and adapters relies on a.
3.5.9 Student Book © 2004 Propane Education & Research CouncilPage 1 Although unloading a bobtail cargo tank in metered delivery service at the bulk plant.
Student Book © 2004 Propane Education & Research CouncilPage Performing Gas Distribution System Leak Checks Requirements for vapor distribution.
3.7.7 Student Book © 2004 Propane Education & Research CouncilPage 1 Replacing DOT IM tank valves and fittings requires careful application of precautions.
MODULE 3 Bobtail Equipment and Systems.
3.3.4 Student Book © 2004 Propane Education & Research CouncilPage Operating a Dispenser to Fill DOT Cylinders by Volume DOT cylinders are designed.
4.1.2 Student Book © 2004 Propane Education & Research CouncilPage Determining System Load and Customer Demand Profile Designing a satisfactory.
Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Converting ASME Tanks in Ammonia Service to Propane.
3.5.6 Student Book © 2004 Propane Education & Research CouncilPage Verifying the Presence of Propane Odorant Drivers and plant unloading personnel.
Copyright © 2010 Delmar, Cengage Learning. ALL RIGHTS RESERVED. Unit 23 Using Gas Welding Equipment.
MODULE 2 Operate the Propane Liquid Supply System.
3.1.8 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Conducting Container Vapor Flaring Operations Before.
3.6.3 Student Book © 2004 Propane Education & Research CouncilPage 1 Personnel who perform tank car unloading operations must comply with company operating.
Fire Fighter Safety SCBA CHANGE/REFILL
Installing DOT/ICC Exchange or Stationary Cylinders
Designing DOT Exchange and Stationary Cylinder Installations
Information to the Customer
Presentation transcript:

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage Performing DOT Cylinder Evacuation and Vapor Flaring Operations Before DOT cylinder maintenance tasks can be done—such as replacing valve or fitting or checking the tare weight of the cylinder—it may be necessary to evacuate propane liquid and flare the propane vapor. In this module, you will learn to identify: (1)procedures for evacuating liquid propane from cylinders (2)procedures for conducting vapor flaring operations

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 1 Evacuating Liquid Propane from Cylinders Evacuation by Gravity Transfer – Propane liquid can be removed from portable and exchange DOT cylinders by gravity transfer. Figure 1. Evacuation of DOT Cylinder by Gravity Transfer

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 2 Evacuating Liquid Propane from Cylinders Evacuation by Gravity Transfer Figure 2. Stationary Cylinder Inverter

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 2 Evacuating Liquid Propane from Cylinders Evacuation Using a Compressor Figure 3. Evacuation of Receiving Tank Using a Portable Vapor Compressor

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 3 Evacuating Liquid Propane from Cylinders Evacuation Using a Compressor Compressor & Scavenging Tank Many bulk plant operators use some type of compressor system for evacuating cylinders. One of the most common methods used is the scavenging system.

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 4 Evacuating Liquid Propane from Cylinders Evacuation Using a Portable Compressor Figure 4. Evacuating Vapor Service Cylinder Inverting cylinders by hand is neither easy to do nor safe.

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 4 Evacuating Liquid Propane from Cylinders Evacuation Using a Portable Compressor If the cylinder is evacuated of liquid propane for the purpose of comparing its weight to the manufacturer’s stamped tare weight as part of requalification, draining it of liquid is all that is required. It can remain pressurized with vapor for the purposes of tare weight comparison and requalification. If however, the cylinder must be de-pressurized in preparation for valve or fitting replacement, the vapor must be reduced to near atmospheric pressure. That process may require the flaring of vapor.

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 4 Conducting Vapor Flaring Operations Flaring is the process of burning LP-gas removed from storage containers in a controlled and safe manner of NFPA 58 requires that LP-gas be burned at least 25 feet from combustibles edition NFPA 58

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 5 Conducting Vapor Flaring Operations Figure 5 Figure 6. Figure 7.

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 6 Conducting Vapor Flaring Operations Figure 8a. Electronic Ignition Flare Tower Figure 8b. Top of Flare Tower Burning Propane from Cylinder

3.2.2 Student Book © 2004 Propane Education & Research CouncilPages Conducting Vapor Flaring Operations Step 1:Evacuate as much propane from the container as possible. Step 2:Select the proper site for flaring the remaining propane in the container. Step 3:Select the necessary equipment for flaring the remaining propane in the container. Step 4:Assemble and connect all necessary hoses, fittings, burner, etc., to flare the remaining propane in the container. Step 5:Pressure test the flaring assembly.

3.2.2 Student Book © 2004 Propane Education & Research CouncilPages Conducting Vapor Flaring Operations Step 6:Flare the remaining propane in the container. Step 7:Bleed down and disconnect the flaring equipment.

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 7 Conducting Vapor Flaring Operations Figure 9. Recommended Site for Flaring Containers (At Bulk Plant) Although the flaring operation is simple, it does involve an open flame. As a result, certain safety precautions should be followed when selecting a site for flaring the container. These safety precautions will limit the danger of an accidental fire while the flaring burner is operating.

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 7 Conducting Vapor Flaring Operations NOTE: The flaring burner should be located at least 25 feet away from the container being flared, any transfer area or important building.

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 7 Conducting Vapor Flaring Operations Flaring equipment should have these features: 1.An orifice or other gas flow controlling device 2.A built-in shutoff valve 3.Designed for vapor service 4.An approximate input rating of 500,000 BTU/hr. or less 5.Should incorporate a regulator

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 8 Conducting Vapor Flaring Operations It is important to select a burner with both a built-in shutoff and a regulator. This allows for adjustment of the output of the burner and prevents any excessive withdrawal from the cylinder or tank being flared. Remember, excessive withdrawal could easily cause the tank or cylinder to temporarily stop vaporizing enough gas to supply the burner. This condition may be noticed when a frost line appears on the container, yet sufficient liquid may remain to re- pressurize the container when it regains heat from surrounding air.

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 8 Conducting Vapor Flaring Operations Figure 10. Supply Hose for Flaring Burner

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 8 Conducting Vapor Flaring Operations Figure 11. Flaring Burner Support

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 10 Conducting Vapor Flaring Operations Figure 11. Flaring Burner Support

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 12 Conducting Vapor Flaring Operations During Step 6, observe the pressure gauge on the service valve (or purging adaptor). When the pressure drops below 15 psig, temporarily shut down the burner and allow the pressures in the tank or cylinder to increase. (Because of the high demand of the burner, the container may refrigerate during the flaring operation. If a frost line develops on the cylinder, temporarily shut down the burner and allow the pressure in the container to increase.) When the vapor pressure no longer increases above 15 psig, flare the remaining vapor until the burner extinguishes.

3.2.2 Student Book © 2004 Propane Education & Research CouncilPage 13 Conducting Vapor Flaring Operations Flaring operations should incorporate the following safety practices and recommendations: 1.Flaring operations should never be left unattended and qualified personnel should continuously monitor flaring equipment and conditions. 2.If qualified personnel must leave the flaring operation for any reason, the operation should be shut down and the valve(s) on the container being flared should be closed. Check with your supervisor or any company- specific procedures that may apply to flaring operations.

3.2.2 Student Book © 2004 Propane Education & Research CouncilPages Time to See If You Got the Key Points of This Module… Complete the Review on pages 14 & 15. See if you are ready for the Certification Exam by checking off the performance criteria on page 16.